Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 345
Filtrar
1.
Semin Thromb Hemost ; 50(2): 275-283, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37327884

RESUMEN

Platelets are central elements of hemostasis and also play a pivotal role in the pathogenesis of thrombosis in coronavirus disease 2019. This study was planned to investigate the effects of different severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) recombinant spike protein variants on platelet morphology and activation. Citrated whole blood collected from ostensibly healthy subjects was challenged with saline (control sample) and with 2 and 20 ng/mL final concentration of SARS-CoV-2 recombinant spike protein of Ancestral, Alpha, Delta, and Omicron variants. Platelet count was found to be decreased with all SARS-CoV-2 recombinant spike protein variants and concentrations tested, achieving the lowest values with 20 ng/mL Delta recombinant spike protein. The mean platelet volume increased in all samples irrespective of SARS-CoV-2 recombinant spike protein variants and concentrations tested, but especially using Delta and Alpha recombinant spike proteins. The values of both platelet function analyzer-200 collagen-adenosine diphosphate and collagen-epinephrine increased in all samples irrespective of SARS-CoV-2 recombinant spike protein variants and concentrations tested, and thus reflecting platelet exhaustion, and displaying again higher increases with Delta and Alpha recombinant spike proteins. Most samples where SARS-CoV-2 recombinant spike proteins were added were flagged as containing platelet clumps. Morphological analysis revealed the presence of a considerable number of activated platelets, platelet clumps, platelet-monocyte, and platelet-neutrophils aggregates, especially in samples spiked with Alpha and Delta recombinant spike proteins at 20 ng/mL. These results provide support to the evidence that SARS-CoV-2 is capable of activating platelets through its spike protein, though such effect varies depending on different spike protein variants.


Asunto(s)
COVID-19 , Glicoproteína de la Espiga del Coronavirus , Humanos , SARS-CoV-2 , Colágeno
2.
Clin Chem Lab Med ; 62(7): 1433-1437, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38176023

RESUMEN

OBJECTIVES: The current study was designed to evaluate the analytical performance of the new Mindray highly sensitive cardiac troponin I (hs-cTnI) chemiluminescent immunoassay on Mindray CL-1200i, as a thorough validation of novel hs-cTnI methods is required before introduction into clinical practice. METHODS: The evaluation of the analytical performance of this hs-cTnI immunoassay encompassed the calculation of the limit of blank (LOB), limit of detection (LOD), functional sensitivity, imprecision, linearity, 99th percentile upper reference limit (URL) and concordance with another previously validated hs-cTnI chemiluminescent immunoassay. RESULTS: The LOB and LOD were 0.32 and 0.35 ng/L, whilst the functional sensitivity (expressed as cTnI value with <10 % imprecision), was 0.35 ng/L. The linearity was excellent throughout a wide range of clinically measurable values (r=1.00 between 0.8 and 9,726.9 ng/mL). The intra-assay, inter-assay and total imprecision were 1.1-1.3 %, 5.5-8.1 % and 5.6-8.2 %, respectively. The 99th percentile URL calculated using residual plasma from 246 ostensibly healthy blood donors was 9.2 ng/L (4.3 ng/L in women vs. 12.3 ng/L in men). The Spearman's correlation between Mindray hs-cTnI and Access hs-TnI was 0.97, with mean bias of 7.2 % (95 % CI, 2.6-11.9 %). CONCLUSIONS: Although we failed to confirm the very optimistic analytical characteristics previously reported for this method, our evaluation of the novel Mindray hs-cTnI immunoassay on CL-1200i demonstrated that the overall performance is comparable to that of other commercially available hs-cTnI techniques, making it a viable alternative to other methods.


Asunto(s)
Límite de Detección , Troponina I , Humanos , Troponina I/sangre , Troponina I/análisis , Inmunoensayo/métodos , Inmunoensayo/normas , Femenino , Masculino , Adulto , Persona de Mediana Edad , Mediciones Luminiscentes/métodos , Mediciones Luminiscentes/normas , Anciano , Reproducibilidad de los Resultados , Valores de Referencia
3.
Clin Chem Lab Med ; 61(8): 1506-1510, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-36883744

RESUMEN

OBJECTIVES: Given that SARS-CoV-2 antigen tests will represent a pillar for supporting or surrogating molecular testing in the endemic period, we report here the clinical performance of the new SNIBE Maglumi SARS-CoV-2 antigen fully-automated chemiluminescent immunoassay (MAG-CLIA SARS-CoV-2 Ag). METHODS: The study population consisted of 181 subjects (mean age 61 ± 21 years; 92 females) undergoing coronavirus disease 2019 (COVID-19) testing at the local diagnostic facility, from December 2022 to February 2023. Routine diagnostic practice involved the collection of a double nostril nasopharyngeal swab, analyzed in duplicate with SARS-CoV-2 antigen (MAG-CLIA SARS-CoV-2 Ag) and molecular (Altona Diagnostics RealStar SARS-CoV-2 RT-PCR Kit) tests. RESULTS: A significant Spearman's correlation was found between MAG-CLIA SARS-CoV-2 Ag and mean Ct values of SARS-CoV-2 E and S genes (r=-0.95; p<0.001). In all nasopharyngeal samples, the area under the curve (AUC) of MAG-CLIA SARS-CoV-2 Ag was 0.86 (95% CI, 0.81-0.90), with 0.71 sensitivity and 1.00 specificity at 7 ng/L cut-off, increasing to 0.98 (95% CI, 0.96-1.00) AUC and 0.96 sensitivity (with 0.97 specificity) in high viral load samples. When SARS-CoV-2 N protein concentration was replaced with raw instrumental readings (i.e., relative light units [RLU]), the AUC in all samples increased to 0.94. A RLU value of 945 was associated with 88.4% accuracy, 0.85 sensitivity, 0.95 specificity, 0.77 negative predictive value (NPV) and 0.97 positive predictive value (PPV), respectively. CONCLUSIONS: We found satisfactory analytical performance of MAG-CLIA SARS-CoV-2 Ag, which could be used as surrogate of molecular testing for identifying high viral load samples. Broadening the reportable range of values may generate even better performance.


Asunto(s)
COVID-19 , SARS-CoV-2 , Femenino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , COVID-19/diagnóstico , Pruebas Inmunológicas , Área Bajo la Curva , Inmunoensayo , Sensibilidad y Especificidad
4.
Clin Chem Lab Med ; 61(2): 316-322, 2023 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-36315978

RESUMEN

OBJECTIVES: This proof of concept study was aimed to validate the hypothesis that the time of positivization of SARS-CoV-2 self-performed rapid diagnostic tests (RDTs) may reflect the actual viral load in the specimen. METHODS: A SARS-CoV-2 positive sample with high viral load was diluted and concomitantly assayed with molecular assay (Xpert Xpress SARS-CoV-2) and RDT (COVID-VIRO ALL IN RDT). The (mean cycle threshold; Ct) values and RDT positivization times of these dilutions were plotted and interpolated by calculating the best fit. The parameters of this equation were then used for converting the positivization times into RDT-estimated SARS-CoV-2 Ct values in routine patient samples. RESULTS: The best fit between measured and RDT-estimated Ct values could be achieved with a 2-degree polynomial curve. The RDT-estimated Ct values exhibited high correlation (r=0.996) and excellent Deming fit (y=1.01 × x - 0.18) with measured Ct values. In 30 consecutive patients with positive RDT test, the correlation between RDT positivization time and measured Ct value was r=0.522 (p=0.003). The correlation of RDT-estimated and measured Ct values slightly improved to 0.577 (Deming fit: y=0.44 × x + 11.08), displaying a negligible bias (1.0; 95% CI, -0.2 to 2.2; p=0.105). Concordance of RDT-estimated and measured Ct values at the <20 cut-off was 80%, with 0.84 sensitivity and 0.73 specificity. CONCLUSIONS: This proof of concept study demonstrates the potential feasibility of using RDTs for garnering information on viral load in patients with acute SARS-CoV-2 infection.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Carga Viral , Autoevaluación , Pruebas Inmunológicas , Sensibilidad y Especificidad
5.
Clin Chem Lab Med ; 61(7): 1343-1348, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-36722026

RESUMEN

OBJECTIVES: This study investigated the feasibility and clinical value of using a novel, automated and high-throughput SARS-CoV-2 Interferon Gamma Release Assay (IGRA), combined with total anti-SARS-CoV-2 antibodies assessment, for evaluating the immune response after bivalent BNT162b2 vaccination. METHODS: A cohort of healthcare workers, who already underwent primary vaccination and boosting with monovalent BNT162b2 vaccine, received a booster dose of the new BNT162b2 bivalent formulation. Blood samples were taken immediately before vaccination (T0) and 1 month afterwards (T1). Humoral and cellular immunity were assayed with Roche Elecsys Anti-SARS-CoV-2 and Roche Elecsys IGRA SARS-CoV-2, respectively. RESULTS: The study population consisted of 51 subjects (median age: 43 years; 51% females). Total anti-SARS-CoV-2 antibodies and IGRA SARS-CoV-2 values increased at T1 from 9,050 to 25,000 BAU/mL (p<0.001), and from 0.44 to 0.78 IU/mL (p=0.385), accounting for median increase of 2.0 and 1.6 folds, respectively. Increased T1 values of total anti-SARS-CoV-2 antibodies and IGRA SARS-CoV-2 were recorded in 100% and 68.6% subjects, respectively. In those with baseline values below the median, post-vaccine levels displayed larger increases of 3.3 and 5.1 folds for anti-SARS-CoV-2 total antibodies and IGRA SARS-CoV-2, respectively. The variation of total anti-SARS-CoV-2 antibodies was inversely associated with their T0 values (r=-0.97; p<0.001), whilst that of IGRA SARS-CoV-2 was inversely associated with its T0 value (r=-0.58; p<0.001). No other signifcant associations were found with demographical or clinical variables, including side effects. CONCLUSIONS: The bivalent BNT162b2 vaccine booster enhances humoral and cellular immunity against SARS-CoV-2, especially in recipients with lower baseline biological protection.


Asunto(s)
Vacuna BNT162 , COVID-19 , Femenino , Humanos , Adulto , Masculino , COVID-19/prevención & control , SARS-CoV-2 , Vacunación , Inmunidad Celular , Anticuerpos Antivirales
6.
Int J Mol Sci ; 24(11)2023 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-37298324

RESUMEN

This study investigated the biological effects on circulating monocytes after challenge with SARS-CoV-2 recombinant spike protein. Whole blood collected from seven ostensibly healthy healthcare workers was incubated for 15 min with 2 and 20 ng/mL final concentration of recombinant spike protein of Ancestral, Alpha, Delta, and Omicron variants. Samples were analyzed with Sysmex XN and DI-60 analyzers. Cellular complexity (i.e., the presence of granules, vacuoles and other cytoplasmic inclusions) increased in all samples challenged with the recombinant spike protein of the Ancestral, Alpha, and Delta variants, but not in those containing Omicron. The cellular content of nucleic acids was constantly decreased in most samples, achieving statistical significance in those containing 20 ng/mL of Alpha and Delta recombinant spike proteins. The heterogeneity of monocyte volumes significantly increased in all samples, achieving statistical significance in those containing 20 ng/mL of recombinant spike protein of the Ancestral, Alpha and Delta variants. The monocyte morphological abnormalities after spike protein challenge included dysmorphia, granulation, intense vacuolization, platelet phagocytosis, development of aberrant nuclei, and cytoplasmic extrusions. The SARS-CoV-2 spike protein triggers important monocyte morphological abnormalities, more evident in cells challenged with recombinant spike protein of the more clinically severe Alpha and Delta variants.


Asunto(s)
COVID-19 , Monocitos , Humanos , Glicoproteína de la Espiga del Coronavirus/genética , SARS-CoV-2
7.
Int J Mol Sci ; 24(16)2023 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-37628976

RESUMEN

Studies investigating the potential role of circulating bile acids (BAs) as diagnostic biomarkers for cholangiocarcinoma (CCA) are sparse and existing data do not adjust for confounding variables. Furthermore, the mechanism by which BAs affect the expression of the oncogenic mucin 5AC (MUC5AC) has never been investigated. We performed a case-control study to characterise the profile of circulating BAs in patients with CCA (n = 68) and benign biliary disease (BBD, n = 48) with a validated liquid chromatography-tandem mass spectrometry technique. Odd ratios (OR) for CCA associations were calculated with multivariable logistic regression models based on a directed acyclic graph structure learning algorithm. The most promising BAs were then tested in an in vitro study to investigate their interplay in modulating MUC5AC expression. The total concentration of BAs was markedly higher in patients with CCA compared with BBD controls and accompanied by a shift in BAs profile toward a higher proportion of primary conjugated BAs (OR = 1.50, CI: 1.14 to 1.96, p = 0.003), especially taurochenodeoxycholic acid (TCDCA, OR = 42.29, CI: 3.54 to 504.63, p = 0.003) after multiple adjustments. Western blot analysis of secreted MUC5AC in human primary cholangiocytes treated with primary conjugated BAs or with TCDCA alone allowed us to identify a novel 230 kDa isoform, possibly representing a post-translationally modified MUC5AC specie.


Asunto(s)
Neoplasias de los Conductos Biliares , Colangiocarcinoma , Humanos , Ácidos y Sales Biliares , Mucina 5AC , Estudios de Casos y Controles , Conductos Biliares Intrahepáticos
8.
Crit Rev Clin Lab Sci ; 59(6): 373-390, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35220860

RESUMEN

With the advent of the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) pandemic, several vaccines have been developed to mitigate its spread and prevent adverse consequences of the Coronavirus Disease 2019 (COVID-19). The mRNA technology is an unprecedented vaccine, usually given in two doses to prevent SARS-CoV-2 infections. Despite effectiveness and safety, inter-individual immune response heterogeneity has been observed in recipients of mRNA-based vaccines. As a novel disease, the specific immune response mechanism responsible for warding off COVID-19 remains unclear at this point. However, significant evidence suggests that humoral response plays a crucial role in affording immunoprotection and preventing debilitating sequelae from COVID-19. As such, this paper focused on the possible effects of age, sex, serostatus, and comorbidities on humoral response (i.e. total antibodies, IgG, and/or IgA) of different populations post-mRNA-based Pfizer-BioNTech vaccination. A systematic search of literature was performed through PubMed, Cochrane CENTRAL, Google Scholar, Science Direct, medRxiv, and Research Square. Studies were included if they reported humoral response to COVID-19 mRNA vaccines. A total of 32 studies were identified and reviewed, and the percent differences of means of reported antibody levels were calculated for comparison. Findings revealed that older individuals, male sex, seronegativity, and those with more comorbidities mounted less humoral immune response. Given these findings, several recommendations were proposed regarding the current vaccination practices. These include giving additional doses of vaccination for immunocompromised and elderly populations. Another recommendation is conducting clinical trials in giving a combined scheme of mRNA vaccines, protein vaccines, and vector-based vaccines.


Asunto(s)
COVID-19 , Vacunas Virales , Anciano , COVID-19/prevención & control , Humanos , Masculino , ARN Mensajero/genética , SARS-CoV-2 , Vacunación
9.
Eur J Neurol ; 29(6): 1855-1858, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35224824

RESUMEN

BACKGROUND AND PURPOSE: Anti-myelin oligodendrocyte glycoprotein antibodies (MOG-Abs) distinguish a group of inflammatory disorders which can be preceded by specific or non-specific infections. A few single cases have been reported in association with SARS-CoV-2 infection, but a specific study on the correlation between COVID-19 and myelin oligodendrocyte glycoprotein (MOG)-associated disorder (MOGAD) has not yet been performed. The aim of this study was to determine the impact of the pandemic on this condition. METHODS: We analysed SARS-CoV-2 serology in patients newly diagnosed with MOGAD (1 August 2020 to 31 May 2021). MOG-Ab-seronegative age- and time-matched subjects were used as controls. SARS-CoV-2 immunoglobulin G (IgG) levels were analysed using an anti-SARS-CoV-2 US Food and Drug Administration-approved ELISA assay and confirmed with a trimeric anti-SARS-CoV-2 S1/S2 IgG immunochemiluminescent test, concomitantly assaying the anti-receptor binding domain (RBD) of spike protein IgG and anti-RBD total Ig. We actually compared the number of cases referred in each of the last 3 years. RESULTS: Presence of SARS-CoV-2 IgG antibodies was more common (12/30, 40%) in MOGAD patients than in controls (6/30, 20%), although the difference was not significant (p = 0.16; odds ratio 2.67, 95% confidence interval 0.85-9.17). The most common clinical presentations of MOGAD SARS-CoV-2-seropositive patients included optic neuritis (n = 6) and myelitis (n = 3). The number of diagnosed cases increased over the last 3 years, in particular, when including cases referred to us before the COVID-19 pandemic, in the initial phase of the first wave and in the late phase of the second wave (n = 9, rate 10.6% in 2019; n = 13, rate 12.3% in 2020; n = 15, rate 14.7% in 2021). CONCLUSION: Our findings provide preliminary data on SARS-CoV-2 as a potential trigger of MOGAD.


Asunto(s)
COVID-19 , Autoanticuerpos , Humanos , Inmunoglobulina G , Glicoproteína Mielina-Oligodendrócito , Pandemias , SARS-CoV-2
10.
Clin Chem Lab Med ; 60(6): 930-933, 2022 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-35303764

RESUMEN

OBJECTIVES: We provide here an updated analysis of an ongoing serosurveillance study, presenting data on the effect of a third dose of Pfizer/BioNTech BNT162b2 vaccine on serum anti-SARS-CoV-2 IgG antibodies. METHODS: We tested baseline SARS-CoV-2 seronegative healthcare workers undergoing primary vaccination with the mRNA-based COVID-19 Comirnaty vaccine, followed by administration of homologous vaccine booster (third dose). Venous blood was collected before either dose of primary vaccination, at 1, 3 and 6 months afterwards, as well as before and 1 month after receiving the vaccine booster. The serum concentration of anti-SARS-CoV-2 IgG was assayed with DiaSorin Trimeric spike IgG immunoassay. RESULTS: The final study population included 53 SARS-CoV-2 seronegative healthcare workers (median age 46 years; 60% females). A first peak of anti-SARS-CoV-2 spike trimeric IgG values was reached 1 month after completing primary vaccination, after which the levels gradually declined until before receiving the vaccine booster. A second peak of anti-SARS-CoV-2 spike trimeric IgG concentration was observed 1 month after receiving the vaccine booster dose (8,700 kBAU/L), which was 39-fold higher than before receiving the vaccine booster (221 kBAU/L; p<0.001), but was also nearly threefold higher compared to values seen at the first peak (2,990 kBAU/L; p<0.001). The rate of subjects with protective anti-SARS-CoV-2 spike trimeric IgG values (i.e., >264 kBAU/L) increased from 47.2% to 100% after 1 month from vaccine booster. CONCLUSIONS: These results support current policies fostering COVID-19 vaccine boosters to reinforce humoral immunity against SARS-CoV-2.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Antivirales , Vacuna BNT162 , COVID-19/prevención & control , Vacunas contra la COVID-19 , Femenino , Humanos , Inmunoglobulina G , Masculino , Persona de Mediana Edad
11.
New Microbiol ; 45(4): 353-354, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36538301

RESUMEN

We evaluated the performance of Fujirebio Lumipulse G SARS-CoV-2 Ag chemiluminescent immunoassay. A nasopharyngeal swab was collected from 160 subjects and assayed simultaneously with Fujirebio Lumipulse G SARS-CoV-2 Ag and Altona Diagnostics RealStar SARS-CoV-2 RT-PCR assays. Using 0.60 pg/mL diagnostic threshold, Fujirebio Lumipulse G SARS-CoV-2 Ag displayed 0.88 area under the curve, 0.88 sensitivity and 0.75 specificity compared to molecular testing. The area under the curve increased to 1.00 after excluding samples with low viral load (i.e., cycle threshold values between 25-37). Thus, this chemiluminescent immunoassay could be used for rapid identification of many subjects with high nasopharyngeal SARS-CoV-2 viral load.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Inmunoensayo , Sensibilidad y Especificidad , Antígenos Virales
12.
Eur J Clin Microbiol Infect Dis ; 40(4): 897-900, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33078222

RESUMEN

Results of three rapid immunochromatographic tests (ICTs) were compared with those obtained with two automated immunoassays for evaluation of their usefulness. One hundred fifty-nine patients and 67 healthy volunteers were included. Different assays demonstrate 41-45% of diagnostic sensitivities and 91-98% of specificities, with substantial agreement (89.3-91.2%), but a high percentage of weak positive results (13-22%) was observed with ICTs. ICTs performances were comparable to those of automated immunoassays. ICTs could have a role as screening approach due to their easy usability. Subjective interpretation, significant rate of uncertain results, uncertainty on viral antigens source are undoubtedly drawbacks.


Asunto(s)
Anticuerpos Antivirales/inmunología , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Proteínas de la Nucleocápside de Coronavirus/inmunología , Inmunoensayo/métodos , Glicoproteína de la Espiga del Coronavirus/inmunología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/inmunología , Prueba de Ácido Nucleico para COVID-19 , Niño , Femenino , Humanos , Inmunoglobulina A/inmunología , Inmunoglobulina G/inmunología , Masculino , Persona de Mediana Edad , Fosfoproteínas/inmunología , SARS-CoV-2/inmunología , Sensibilidad y Especificidad , Adulto Joven
13.
Clin Chem Lab Med ; 59(9): 1585-1591, 2021 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-33838087

RESUMEN

OBJECTIVES: Since universal vaccination is a pillar against coronavirus disease 2019 (COVID-19), monitoring anti-SARS-CoV-2 neutralizing antibodies is essential for deciphering post-vaccination immune response. METHODS: Three healthcare workers received 30 µg BNT162b2 mRNA Covid-19 Pfizer Vaccine, followed by a second identical dose, 21 days afterwards. Venous blood was drawn at baseline and at serial intervals, up to 63 days afterwards, for assessing total immunoglobulins (Ig) anti-RBD (receptor binding domain), anti-S1/S2 and anti-RBD IgG, anti-RBD and anti-N/S1 IgM, and anti-S1 IgA. RESULTS: All subjects were SARS-CoV-2 seronegative at baseline. Total Ig anti-RBD, anti-S1/S2 and anti-RBD IgG levels increased between 91 and 368 folds until 21 days after the first vaccine dose, then reached a plateau. The levels raised further after the second dose (by ∼30-, ∼8- and ∼8-fold, respectively), peaking at day 35, but then slightly declining and stabilizing ∼50 days after the first vaccine dose. Anti-S1 IgA levels increased between 7 and 11 days after the first dose, slightly declined before the second dose, after which levels augmented by ∼24-fold from baseline. The anti-RBD and anti-N/S1 IgM kinetics were similar to that of anti-S1 IgA, though displaying substantially weaker increases and modest peaks, only 4- to 7-fold higher than baseline. Highly significant inter-correlation was noted between total Ig anti-RBD, anti-S1/S2 and anti-RBD IgG (all r=0.99), whilst other anti-SARS-CoV-2 antibodies displayed lower, though still significant, correlations. Serum spike protein concentration was undetectable at all-time points. CONCLUSIONS: BNT162b2 mRNA vaccination generates a robust humoral immune response, especially involving anti-SARS-Cov-2 IgG and IgA, magnified by the second vaccine dose.


Asunto(s)
Anticuerpos Antivirales/inmunología , Vacunas contra la COVID-19/inmunología , COVID-19/inmunología , Inmunidad/inmunología , ARN Mensajero/inmunología , SARS-CoV-2/inmunología , Vacunación/métodos , Adulto , Vacuna BNT162 , COVID-19/prevención & control , COVID-19/virología , Vacunas contra la COVID-19/administración & dosificación , Vacunas contra la COVID-19/genética , Femenino , Humanos , Masculino , Persona de Mediana Edad , ARN Mensajero/administración & dosificación , ARN Mensajero/genética , SARS-CoV-2/genética
14.
Clin Chem Lab Med ; 58(6): 994-1001, 2020 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-32191622

RESUMEN

The diffusion of laboratory automation, initiated nearly 50 years ago with consolidation of preanalytical, clinical chemistry and immunochemistry workstations, is now also gradually embracing mass spectrometry (MS). As for other diagnostic disciplines, the automation of MS carries many advantages, such as efficient personnel management (i.e. improving working atmosphere by decreasing manual activities, lowering health risks, simplifying staff training), better organization (i.e. reducing workloads, improving inventory handling, increasing analytical process standardization) and the possibility to reduce the number of platforms. The development and integration of different technologies into automated MS analyzers will also generate technical and practical advantages, such as prepackaged and ready-to-use reagents, automated dispensing, incubation and measurement, automated sample processing (e.g. system fit for many models of laboratory automation, bar code readers), multiplex testing, automatic data processing, also including quality control assessment, and automated validation/interpretation (e.g. autoverification). A new generation of preanalytical workstations, which can be directly connected to MS systems, will allow the automation of manual extraction and elimination of time-consuming activities, such as tube labeling and capping/decapping. The use of automated liquid-handling platform for pipetting samples, along with addition of internal standards, may then enable the optimization of some steps of extraction and protein precipitation, thus decreasing turnaround time and increasing throughput in MS testing. Therefore, this focused review is aimed at providing a brief update on the importance of consolidation and integration of MS platforms in laboratory automation.


Asunto(s)
Laboratorios , Espectrometría de Masas , Automatización , Factores de Tiempo , Flujo de Trabajo
15.
Clin Chem Lab Med ; 58(10): 1707-1712, 2020 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-32286239

RESUMEN

Background Calcitonin gene-related peptide (CGRP) is a powerful neuropeptide that is strongly involved in headache pain pathogenesis by triggering vasodilation, mast cell degranulation and neurogenic inflammation. This evidence has prompted us to investigate the acute influence of endurance exercise on CGRP concentration in blood. Methods The study population consisted of 48 male amateur runners, who ran a half-marathon distance at 75%-85% of maximal oxygen uptake. Blood was drawn before the run (pre-run) and immediately after each runner ended his trial (post-run). The serum concentration of CGRP was measured with a commercial enzyme-linked immunosorbent assay (ELISA) technique. Results Overall, 22/48 subjects (45.8%) reported suffering from headache, three of whom (6.2%) had an exertional headache, whilst 26/48 (54.2%) subjects did not report at least one headache episode during the previous 6 months (i.e. headache-free). All 48 athletes successfully covered the 21.1 km distance. Serum concentration of CGRP significantly increased by 1.5-fold in the entire group, as well as in the headache-positive and headache-free cohorts. Univariate Spearman's correlation revealed that post-run variation of serum CGRP was significantly and inversely associated with running time (r = -0.30; p = 0.036). Conclusions The serum concentration of CGRP is significantly enhanced by medium-distance endurance exercise and the post-exercise increase is dependent on running intensity. Accordingly, high-exercise intensity might be directly related to triggering both exertional headache and/or migraine episodes.


Asunto(s)
Péptido Relacionado con Gen de Calcitonina/sangre , Ejercicio Físico , Cefalea/sangre , Resistencia Física , Adulto , Humanos , Masculino , Persona de Mediana Edad
16.
Semin Thromb Hemost ; 45(3): 308-314, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30699441

RESUMEN

This study aimed to provide a preliminary evaluation of the analytical performance of the new Roche COBAS T 711: fully automated coagulation analyzer, which uses both liquid and lyophilized reagent cassettes. The analytical assessment included analysis of imprecision and linearity of prothrombin time (PT), activated partial thromboplastin time (APTT), and fibrinogen on COBAS T 711: analyzer. Test results of 120 routine plasma samples were also compared with those obtained using two other coagulation analyzers (Instrumentation Laboratory ACL TOP 700 and Stago STA-R MAX). The accuracy, imprecision, and comparability of manual and automatic lyophilized material resuspension were also evaluated using 200 routine plasma samples. Overall, automatic resuspension was found to be more precise than, and equally accurate as, manual reconstitution, with coefficient of variations (CV%) three- to sixfold lower compared with manual reconstitution. The analytical imprecision was found to be excellent, as attested by total CV% of 0.7% for PT, 1.7 to 1.8% for APTT, and 1.9 to 3.2% for fibrinogen. Linearity was excellent over a clinically significant range of PT, APTT, and fibrinogen values, displaying correlation coefficients comprised between 0.994 and 0.999. Methods comparison studies revealed that results of PT, APTT, and fibrinogen on COBAS T 711: are globally aligned with those obtained using identical plasma samples on IL ACL TOP 700 and Stago STA-R MAX, displaying correlation coefficients of 0.97 for PT, 0.81 and 0.88 for APTT, 0.90 and 0.94 for fibrinogen, respectively. In conclusion, the results of this preliminary evaluation demonstrate that PT, APTT, and fibrinogen on COBAS T 711: coagulation analyzer displays excellent performance for routine use in clinical laboratories.


Asunto(s)
Pruebas de Coagulación Sanguínea/métodos , Coagulación Sanguínea/inmunología , Hemostasis/inmunología , Humanos , Laboratorios
17.
Clin Chem Lab Med ; 58(1): 77-84, 2019 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-31539351

RESUMEN

Background This two-center study was designed to verify comparability of procalcitonin (PCT) values among 10 different commercial immunoassays. Methods A total number of 176 routine lithium-heparin plasma samples were divided in identical aliquots and simultaneously analyzed with 10 different PCT immunoassays, including Kryptor BRAHMS PCT sensitive, Abbott Architect BRAHMS PCT, Beckman Coulter Access PCT (on Access and DXI), BioMérieux Vidas BRAHMS PCT, Diasorin Liaison BRAHMS PCT, Fujirebio Lumipulse G BRAHMS PCT, Roche BRAHMS PCT (on Cobas E801), Diazyme PCT (on Roche Cobas C702) and SNIBE Maglumi PCT. Results Highly significant correlation was always found across multiple comparisons, with correlation coefficients comprised between 0.918 and 0.997 (all p < 0.001). Bland and Altman plots analysis revealed highly variable bias among immunoassays, ranging between ±0.2% and ±38.6%. Diazyme PCT on Roche Cobas C702 and SNIBE Maglumi PCT displayed the larger overestimation, whilst PCT values were underestimated by Cobas BRAHAMS PCT. The agreement was always >80% (all p < 0.001), but varied largely across multiple comparisons, ranging between 90%-99% at 0.1 µg/L, 81%-99% at 0.25 µg/L, 83%-100% at 0.5 µg/L, 94%-100% at 2.0 µg/L and 90%-99% at 10 µg/L, respectively. The larger disagreement was observed comparing Diazyme PCT and Maglumi PCT with the other methods. Conclusions Although we found acceptable correlation among 10 commercial PCT immunoassays, the limited agreement at clinical decision thresholds remains a major issue, especially at lower end of PCT concentration, thus potentially contributing to jeopardize the clinical value of this biomarker.


Asunto(s)
Inmunoensayo/métodos , Polipéptido alfa Relacionado con Calcitonina/análisis , Automatización , Humanos , Polipéptido alfa Relacionado con Calcitonina/sangre , Polipéptido alfa Relacionado con Calcitonina/inmunología
18.
Clin Chem Lab Med ; 57(11): 1784-1789, 2019 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-30939111

RESUMEN

Background Although accumulating evidence suggests that the hemostatic balance is impaired in patients with hypertriglyceridemia, hyperbilirubinemia or hemolytic anemias, little is known on the underlying biological mechanisms. This experimental study was aimed at exploring whether increasing values of triglycerides, bilirubin or cell-free hemoglobin promote thrombin generation in plasma. Methods Three different pools were prepared from three different sets of 20 normal routine plasma citrate samples. The native pools were spiked with increasing amounts of exogenous triglycerides (up to 8.8 mmol/L), bilirubin (up to 350 µmol/L) or autologous hemolyzed blood (up to 3.5 g/L cell-free hemoglobin). Using the fully-automated thrombin generation analyzer ST Genesia, we measured the following parameters: lag time (LT), time to peak (TP), peak height (PH) and endogenous thrombin potential (ETP). Results A sustained increase of PH and ETP was found in parallel with increasing triglyceride concentrations, peaking in the aliquot with 8.8 mmol/L. Conversely, LT and TP displayed an opposite trend, reaching a maximum decrease in the 8.8 mmol/L aliquot. Increasing bilirubin concentrations promoted remarkable increases of PH and ETP and decreases of TP and LT, up to 211 µmol/L. After this threshold, all parameters tended to return towards baseline values. A constant increase of PH and ETP was also noted in hemolyzed samples, peaking in the 3.5 g/L cell-free hemoglobin aliquot, whereas the TP and LT remained unchanged in all hemolyzed aliquots. Conclusions Our findings suggest that hypertriglyceridemia, hyperbilirubinemia and hemolysis may promote a hypercoagulable state in human plasma.


Asunto(s)
Hemólisis/fisiología , Hiperbilirrubinemia/sangre , Plasma/metabolismo , Trombina/efectos adversos , Pruebas de Coagulación Sanguínea/métodos , Femenino , Humanos , Hiperbilirrubinemia/etiología , Hipertrigliceridemia/sangre , Hipertrigliceridemia/etiología , Masculino
19.
Scand J Clin Lab Invest ; 79(4): 276-279, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31035815

RESUMEN

Current recommendations advocate that blood tubes for coagulation testing should be filled not less than 90% of their nominal filling volume, since under- or over-filling >10% may generate unreliable results of some hemostasis assays. This study was hence aimed to explore filling accuracy and precision of commercial blood tubes. Between-lot variations of 3 different lots (20 tubes per lot) of 3.2% citrate blood tubes manufactured by Becton Dickinson, Greiner and Kima were studied. One additional lot from each manufacturer was assessed in triplicate (three series of 20 tubes), to assess within-lot variation. All tubes were first weighed empty and then filled with distilled water by a syringe, under ideal filling conditions. Filled tubes were weighed again, in duplicate. For each 20 tubes series, mean bias (deviation from the ideal tube filling volume) and imprecision (coefficient of variation; CV%) were calculated. All biases were within ±10%. Within-lot and between-lot variation in filling volume was acceptable, and comprised between 0.4 and 2.4%. Greiner tubes were the most accurate (bias, -1.0 to 2.4%), followed by Kima (bias, -7.8 to -5.9%) and Becton Dickinson (bias, -9.6 to 3.3%) tubes. The highest between-lot difference was noted for Becton Dickinson tubes (up to 12.9%), followed by Greiner and Kima tubes (up to 3.4 and 1.8%, respectively). Although coagulation tubes filling accuracy was within ±10% for all three tested manufacturers, the overall bias was found to be variable among manufacturers and lots. Major effort shall be made by blood tube manufacturers for improving standardization of their products.


Asunto(s)
Pruebas de Coagulación Sanguínea/economía , Pruebas de Coagulación Sanguínea/instrumentación , Coagulación Sanguínea/efectos de los fármacos , Citrato de Sodio/farmacología , Humanos
20.
Semin Thromb Hemost ; 44(8): 747-755, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30119138

RESUMEN

Since the impact of possible prothrombotic factors on blood coagulation resulting from exercise remains elusive, this study investigated the acute effects of middle-distance endurance running on blood coagulation parameters in middle-aged athletes. The study population consisted of 33 male endurance runners who were engaged in a 21.1 km run under competitive conditions. Blood samples were collected before the run, immediately after the run, and 3 hours after run completion. Samples were assessed for activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen, D-dimer, factor VIII (FVIII), von Willebrand factor antigen (VWF:Ag), endogenous thrombin potential (area under the curve of thrombin generation [TGA-AUC]), and peak thrombin generation (TGA-PK). Post-run variations were expressed as delta (Δ). At baseline, APTT was found to be significantly associated with ABO blood group, VWF:Ag, and FVIII; fibrinogen with age; VWF:Ag with BMI, training regimen, and ABO blood group; APTT with FVIII; FVIII with VWF:Ag and ABO blood group; APTT with VWF:Ag; and TGA-PK with ABO blood group, PT, and TGA-AUC. Immediately after the run, statistically significant increases were observed for PT, D-dimer, VWF:Ag, and FVIII, while statistically significant reductions could be observed for APTT, TGA-AUC, and TGA-PK. Fibrinogen values remained unchanged. Significant correlations were observed between Δ VWF:Ag and Δ FVIII, Δ APTT and Δ VWF:Ag, Δ APTT and Δ FVIII, Δ TGA-AUC and Δ TGA-PK, and between Δ D-dimer and Δ TGA-AUC and Δ TGA-PK. No Δ variation was associated with running time. The results of this study seemingly suggest that middle-distance competitive running may evoke several prothrombotic changes in blood coagulation.


Asunto(s)
Atletas , Ejercicio Físico/fisiología , Resistencia Física/fisiología , Trombosis/fisiopatología , Adulto , Coagulación Sanguínea/fisiología , Factor VIII/metabolismo , Fibrinógeno/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Tiempo de Tromboplastina Parcial , Carrera/fisiología , Trombina/metabolismo , Trombosis/sangre , Factor de von Willebrand/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA