Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
1.
Sleep Breath ; 28(5): 1997-2004, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38987507

RESUMEN

PURPOSE: To examine factors accounting for differences in hyoid motion during obstructive breathing events amongst obstructive sleep apnea (OSA) patients. METHODS: This was a prospective cohort study from June 2022 to October 2022. Patients with OSA undergoing evaluation for PAP alternative therapies with drug-induced sleep endoscopy with positive airway pressure titration (DISE-PAP). All patients underwent DISE-PAP and concurrent hyoid-focused ultrasound. DISE-PAP enabled measurement of airway physiology (flow, respiratory effort) and airway collapsibility (pharyngeal opening pressure, PhOP). Hyoid-ultrasound enabled hyoid bone movement during obstructive breathing. Respiratory effort was measured using a retro-epiglottic pressure-sensitive catheter. Hyoid position was measured using a standardized, awake, CT protocol. Regression analyses adjusted for age, race, sex, and BMI were performed to associate indices of respiratory effort and CT data with hyoid motion. RESULTS: On average, the 26 patients in this cohort were older (63.9 ± 10.5 years), male (69%), overweight (29.6 ± 3.99 kg/m2), and with moderate-to-severe OSA (26.8 ± 10.4 events/hour). Greater respiratory effort was associated with increased hyoid motion (ß [95% CI] = 0.034 [0.016,0.052], standardized ß = 0.261,p = 0.0003). Higher hyoid position was associated with greater hyoid displacement (ß [95% CI] = -0.20 [-0.38,-0.01], Standardized ß = -0.57, p = 0.036). CONCLUSION: Our data demonstrate that greater respiratory effort, higher hyoid position, and higher airway collapsibility, but not airflow, are associated with greater hyoid motion during obstructive breathing in DISE. These findings suggest that downward hyoid movement represents a compensatory response to upper airway obstruction. Further studies should investigate the vectors of hyoid motion to better understand its role in sleep-related airway collapse.


Asunto(s)
Hueso Hioides , Apnea Obstructiva del Sueño , Humanos , Hueso Hioides/diagnóstico por imagen , Hueso Hioides/fisiología , Hueso Hioides/fisiopatología , Masculino , Apnea Obstructiva del Sueño/fisiopatología , Apnea Obstructiva del Sueño/diagnóstico por imagen , Persona de Mediana Edad , Femenino , Estudios Prospectivos , Anciano , Endoscopía , Estudios de Cohortes , Presión de las Vías Aéreas Positiva Contínua , Polisomnografía
2.
Sensors (Basel) ; 24(14)2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39066017

RESUMEN

Liver fibrosis, a major global health issue, is marked by excessive collagen deposition that impairs liver function. Noninvasive methods for the direct visualization of collagen content are crucial for the early detection and monitoring of fibrosis progression. This study investigates the potential of spectral photoacoustic imaging (sPAI) to monitor collagen development in liver fibrosis. Utilizing a novel data-driven superpixel photoacoustic unmixing (SPAX) framework, we aimed to distinguish collagen presence and evaluate its correlation with fibrosis progression. We employed an established diethylnitrosamine (DEN) model in rats to study liver fibrosis over various time points. Our results revealed a significant correlation between increased collagen photoacoustic signal intensity and advanced fibrosis stages. Collagen abundance maps displayed dynamic changes throughout fibrosis progression. These findings underscore the potential of sPAI for the noninvasive monitoring of collagen dynamics and fibrosis severity assessment. This research advances the development of noninvasive diagnostic tools and personalized management strategies for liver fibrosis.


Asunto(s)
Colágeno , Cirrosis Hepática , Técnicas Fotoacústicas , Técnicas Fotoacústicas/métodos , Animales , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Cirrosis Hepática/inducido químicamente , Cirrosis Hepática/metabolismo , Colágeno/metabolismo , Colágeno/química , Ratas , Hígado/diagnóstico por imagen , Hígado/patología , Hígado/metabolismo , Masculino , Dietilnitrosamina/toxicidad , Modelos Animales de Enfermedad
3.
J Clin Ultrasound ; 50(9): 1353-1359, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36205388

RESUMEN

In view of the inherent limitations associated with performing dynamic contrast enhanced-magnetic resonance imaging (DCE-MRI) in clinical settings, current study was designed to provide a proof of principle that Doppler sonography and DCE-MRI derived perfusion parameters yield similar hemodynamic information from metastatic lymph nodes in squamous cell carcinomas of head and neck (HNSCCs). Strong positive correlations between volume fraction of plasma space in tissues (Vp ) and blood volume (r = 0.72, p = 0.02) and between Vp and %area perfused (r = 0.65, p = 0.04) were observed. Additionally, a moderate positive correlation trending towards significance was obtained between volume transfer constant (Ktrans ) and %area perfused (r = 0.49, p = 0.09).


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias de Cabeza y Cuello , Humanos , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Carcinoma de Células Escamosas de Cabeza y Cuello/tratamiento farmacológico , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/tratamiento farmacológico , Medios de Contraste , Quimioterapia de Inducción , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/tratamiento farmacológico , Carcinoma de Células Escamosas/patología , Imagen por Resonancia Magnética/métodos
4.
Radiology ; 298(1): 104-111, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33201789

RESUMEN

Background The current standard for assessing the severity of portal hypertension is the invasive acquisition of hepatic venous pressure gradient (HVPG). A noninvasive US-based technique called subharmonic-aided pressure estimation (SHAPE) could reduce risk and enable routine acquisition of these pressure estimates. Purpose To compare quantitative SHAPE to HVPG measurements to diagnose portal hypertension in participants undergoing a transjugular liver biopsy. Materials and Methods This was a prospective cross-sectional trial conducted at two hospitals between April 2015 and March 2019 (ClinicalTrials.gov identifier, NCT02489045). This trial enrolled participants who were scheduled for transjugular liver biopsy. After standard-of-care transjugular liver biopsy and HVPG pressure measurements, participants received an infusion of a US contrast agent and saline. During infusion, SHAPE data were collected from a portal vein and a hepatic vein, and the difference was compared with HVPG measurements. Correlations between data sets were determined by using the Pearson correlation coefficient, and statistical significance between groups was determined by using the Student t test. Receiver operating characteristic analysis was performed to determine the sensitivity and specificity of SHAPE. Results A total of 125 participants (mean age ± standard deviation, 59 years ± 12; 80 men) with complete data were included. Participants at increased risk for variceal hemorrhage (HVPG ≥12 mm Hg) had a higher mean SHAPE gradient compared with participants with lower HVPGs (0.79 dB ± 2.53 vs -4.95 dB ± 3.44; P < .001), which is equivalent to a sensitivity of 90% (13 of 14; 95% CI: 88, 94) and a specificity of 80% (79 of 99; 95% CI: 76, 84). The SHAPE gradient between the portal and hepatic veins was in good overall agreement with the HVPG measurements (r = 0.68). Conclusion Subharmonic-aided pressure estimation is an accurate noninvasive technique for detecting clinically significant portal hypertension. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Kiessling in this issue.


Asunto(s)
Medios de Contraste , Hipertensión Portal/diagnóstico por imagen , Aumento de la Imagen/métodos , Ultrasonografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Estudios Transversales , Femenino , Humanos , Hipertensión Portal/fisiopatología , Masculino , Persona de Mediana Edad , Vena Porta/diagnóstico por imagen , Vena Porta/fisiopatología , Estudios Prospectivos , Sensibilidad y Especificidad
5.
Dig Dis Sci ; 66(12): 4354-4360, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33392869

RESUMEN

BACKGROUND: Portal hypertension is the underlying cause of most complications associated with cirrhosis, with the hepatic venous pressure gradient (HVPG) used for diagnosis and disease progression. Subharmonic imaging (SHI) is a contrast-specific imaging technique receiving at half the transmit frequency resulting in better tissue suppression. AIMS: To determine whether the presence of optimized SHI signals inside the hepatic vein can be used as a screening test for portal hypertension. METHODS: This prospective trial had 131 patients undergoing SHI examination of portal and hepatic veins using a modified Logiq 9 scanner (GE, Waukesha, WI). Images acquired after infusion of the ultrasound contrast agent Sonazoid (GE Healthcare, Oslo, Norway) were assessed for the presence of optimized SHI signals in the hepatic vein and compared to the HVPG values obtained as standard of care. RESULTS: Of 131 cases, 64 had increased HVPG values corresponding to subclinical (n = 31) and clinical (n = 33) portal hypertension (> 5 and > 10 mmHg, respectively), and 67 had normal HVPG values (< 5 mmHg). Two readers performed independent, binary qualitative assessments of the acquired digital clips. Reader one (experienced radiologist) achieved for the subclinical subgroup sensitivity of 98%, specificity of 88%, and ROC area of 0.93 and for the clinical subgroup sensitivity of 100% and specificity of 61%, with an ROC area of 0.74. Reader two (less experienced radiologist) achieved for the subclinical subgroup sensitivity of 77%, specificity of 76%, and ROC area of 0.76 and for the clinical subgroup sensitivity of 88% and specificity of 63%, with an ROC area of 0.70. Readers agreement was of 83% with kappa value of 0.66. CONCLUSION: The presence of optimized SHI signals inside the hepatic vein can be a qualitative screening test for portal hypertension, which could reduce the need for invasive diagnostic procedures.


Asunto(s)
Venas Hepáticas/diagnóstico por imagen , Hipertensión Portal/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Compuestos Férricos , Humanos , Hierro , Masculino , Persona de Mediana Edad , Óxidos , Estudios Prospectivos , Adulto Joven
6.
J Clin Ultrasound ; 48(7): 369-376, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32491197

RESUMEN

PURPOSE: To evaluate technical and patient-related factors that can affect the reliability of acoustic radiation force impulse shear wave elastography (ARFI-SWE) in morbidly obese patients. METHODS: A prospective single-center study was performed on 41 patients (32 females, 78%) presenting for preoperative evaluation for bariatric surgery. ARFI-SWE was performed using a 6 to 1.5 MHz curved (6C1) transducer. Hepatic steatosis was mild, moderate, severe, and absent in 24.4%, 12.2%, 43.9%, and 19.5% of patients, respectively. Interquartile range/median (IQR/M) ranged from 0.05 to 2.07 (0.78 ± 0.56 m/s). Twenty patients (48.7%) had reliable measurements (IQR/M < 0.3). Shear wave velocity (SWV) values were >1.34 m/s (clinically significant fibrosis) in 25 of 41 patients (61%) and >2.2 m/s (advanced fibrosis) in 19 patients (46%). RESULTS: Median SWV was correlated with body mass index (BMI; correlation coefficient [CC] = .37; 95% CI, 0.07-0.61; P-value = .03) and skin-to-liver capsule distance (SLD) (CC = .38; 95% CI, 0.09-0.62; P-value = .01). IQR/M was higher in patients with BMI > 40 (0.24 ± 0.11 vs 0.39 ± 0.25, P-value = .031) and SLD > 3 cm (0.46 ± 0.27 vs 0.23 ± 0.08, P-value = .001), and there was higher number of unreliable examinations among patient with SLD > 3 cm (16/23 vs 5/18, P-value = .01). CONCLUSION: ARFI-SWE is technically more challenging among patients with higher BMI and SLD, resulting in a higher number of unreliable studies, which highlights the need for further advancement of ARFI technology.


Asunto(s)
Índice de Masa Corporal , Diagnóstico por Imagen de Elasticidad/métodos , Hígado/diagnóstico por imagen , Obesidad Mórbida/diagnóstico , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
7.
Breast Cancer Res Treat ; 173(2): 365-373, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30343454

RESUMEN

PURPOSE: Early diagnosis of triple-negative (TN) breast cancer is important due to its aggressive biological characteristics, poor clinical outcomes, and limited options for therapy. The goal of this study is to evaluate the potential of machine learning with quantitative ultrasound image features for the diagnosis of TN breast cancer. METHODS: Ultrasonic and clinical data of 140 surgically confirmed breast cancer cases were analyzed retrospectively for the diagnosis of TN and non-TN (NTN) subtypes. The subtypes were classified based on the expression of estrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor 2 (HER2). Ultrasound image features were measured from the grayscale and color Doppler images and used with logistic regression for classification by machine learning. Leave-one-out cross validation was used to train and test the differentiation. Diagnostic performance was measured by the area under receiver operating characteristic (ROC) curve, and sensitivity and specificity determined at the Youdons index. RESULTS: Of the twelve grayscale and Doppler features measured, eight were found to be statistically different for the TN and NTN subtypes (p < 0.05). The area under the ROC curve (AUC) of the statistically significant grayscale (GS) and color Doppler (CD) features was 0.85 and 0.65, respectively. The AUC increased to 0.88 when the GS and CD features were used together, with sensitivity of 86.96% and specificity of 82.91%. Consideration of patient age in the analysis did not improve discrimination of TN and NTN. CONCLUSIONS: The analysis of breast ultrasound images by machine learning achieves high level of differentiation between the TN and NTN subtypes, exceeding the diagnostic performance by standard visual assessments of the images.


Asunto(s)
Detección Precoz del Cáncer/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Aprendizaje Automático , Neoplasias de la Mama Triple Negativas/diagnóstico por imagen , Adulto , Mama/diagnóstico por imagen , Mama/patología , Femenino , Humanos , Persona de Mediana Edad , Curva ROC , Estudios Retrospectivos , Neoplasias de la Mama Triple Negativas/patología , Ultrasonografía Doppler en Color/métodos , Ultrasonografía Mamaria/métodos
8.
Microcirculation ; 26(7): e12576, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31140665

RESUMEN

OBJECTIVE: Low-intensity anti-vascular ultrasound therapy is an effective means of disrupting the blood supply in the tumor microenvironment. Its diminished effect on the surrounding vasculature is thought to be due to higher blood flow rates outside the tumor that decreases the interaction time between the endothelial lining and the microbubbles, which transduce acoustic energy to thermal heat. However, investigating the effect of circulation rate on the response to low-intensity ultrasound is complicated by the heterogeneity of the in vivo vascular microenvironment. Here, a 3D microfluidic model is used to directly interrogate the dynamics of ultrasound stimulation. METHODS: A 3D in vitro vessel consisting of LifeACT transfected endothelial cells facilitate real-time analysis of actin dynamics during ultrasound treatment. Using an integrated testing platform, both the flow rate of microbubbles within the vessel and the magnitude of insonation can be varied. RESULTS: Morphological measurements and dextran transport assays indicate that lower flow rates exacerbate the effect of low-intensity ultrasound on vessel integrity. Additionally, immunostaining for VE-cadherin and transmission electron microscopy provide further insight into structural changes in cell-cell junctions following insonation. CONCLUSIONS: Overall, these results reveal that blood flow rate is an important parameter to consider during the refinement of anti-vascular low-intensity ultrasound therapies.


Asunto(s)
Células Endoteliales/metabolismo , Microfluídica , Modelos Cardiovasculares , Neoplasias , Neovascularización Patológica , Microambiente Tumoral , Terapia por Ultrasonido , Antígenos CD/metabolismo , Cadherinas/metabolismo , Células Endoteliales/patología , Humanos , Neoplasias/irrigación sanguínea , Neoplasias/metabolismo , Neoplasias/patología , Neoplasias/terapia , Neovascularización Patológica/metabolismo , Neovascularización Patológica/patología , Neovascularización Patológica/terapia
9.
Langmuir ; 35(31): 10079-10086, 2019 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-30768278

RESUMEN

Microbubbles are used as ultrasound contrast agents in medical diagnosis and also have shown great promise in ultrasound-mediated therapy. However, short lifetime and broad size distribution of microbubbles limit their applications in therapy and imaging. Moreover, it is challenging to tailor the echogenic response of microbubbles to make them suitable for specific applications. To overcome these challenges, we use microfluidic flow-focusing to prepare monodisperse microbubbles with a mixture of a recombinant amphiphilic protein, oleosin, and a synthetic amphiphilic copolymer, Pluronic. We show that these microbubbles have superior uniformity and stability under ultrasonic stimulation compared to commercial agents. We also demonstrate that by using different Pluronics, the echogenic response of the microbubbles can be tailored. Our work shows the versatility of using the combination of microfluidics and protein/copolymer mixtures as a method of engineering microbubbles. This tunability could potentially be important and powerful in producing microbubble agents for theranostic applications.


Asunto(s)
Medios de Contraste/química , Microburbujas , Proteínas de Plantas/química , Poloxámero/química , Proteínas Recombinantes/química , Tensoactivos/química , Dispositivos Laboratorio en un Chip , Microfluídica/instrumentación , Microfluídica/métodos , Ultrasonografía
10.
J Surg Oncol ; 119(8): 1070-1076, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30874312

RESUMEN

BACKGROUND: Photoacoustic imaging (PAI) is a noninvasive technique for melanin detection within melanoma metastases. While ex vivo and early studies suggest promising clinical application, there are no standardized parameters for defining presence of melanoma metastases. METHODS: Following flank/hindlimb melanoma induction in BRaf-PTEN transgenic mice, bilateral inguinal lymph nodes (LN) were imaged in vivo at 4 to 8 weeks using PAI. Fourteen diagnostic parameters for in vivo detection of LN metastases were compared using the receiver operating characteristic and area-under-the-curve (AUC). Limits of detectability were assessed in ex vivo and in vitro phantom studies. RESULTS: Forty-nine LNs were imaged in 25 mice. Among metastatic LNs, tumor size ranged from scattered cells to 2.8 mm. The strongest predictor of LN metastasis was the ratio of peak 10% PA melanin signal in the LN compared with adjacent soft tissue (median 4.22 for positive LNs vs 1.07 for negative LNs, P < 0.0001). The AUC was 0.95 (95% CI, 0.90-1.00). In phantom studies, B16 tumor cells were detectable at a concentration of 10 to 25 cells/µL and at a tissue depth of 2.5-3 cm. CONCLUSIONS: We identified a simple, objective diagnostic parameter for identifying melanoma LN metastases in vivo. These findings may help inform the design of future clinical trials.


Asunto(s)
Ganglios Linfáticos/diagnóstico por imagen , Melanoma Experimental/diagnóstico por imagen , Técnicas Fotoacústicas/métodos , Neoplasias Cutáneas/diagnóstico por imagen , Animales , Xenoinjertos , Conducto Inguinal/diagnóstico por imagen , Ganglios Linfáticos/patología , Metástasis Linfática , Melaninas/análisis , Melaninas/metabolismo , Melanoma Experimental/metabolismo , Melanoma Experimental/patología , Ratones , Ratones Noqueados , Ratones Transgénicos , Trasplante de Neoplasias , Sensibilidad y Especificidad , Neoplasias Cutáneas/metabolismo , Neoplasias Cutáneas/patología , Porcinos
11.
J Ultrasound Med ; 38(2): 471-479, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30121962

RESUMEN

OBJECTIVES: Vascular resistance is known to be one of the determinants of pulsatile flow. This study aimed to investigate whether quantitative 2-dimensional Doppler ultrasound can capture and evaluate the pulsatility within the placental bed vasculature. METHODS: The placental bed vasculature was imaged by directional power Doppler ultrasound. Ten-second cine clips were recorded by using standardized machine settings. A region of interest with a prominent Doppler signal in the uteroplacental interface was analyzed for the percentage of vascularity to generate a time-vascularity waveform. A vascular pulsatility index representing variation over the cardiac cycle was calculated by the ratio of the systolic-diastolic difference in vascularity to the mean vascularity. The acquisitions were repeated with 6 different pulse repetition frequencies (PRFs) and 3 wall motion filter (WMF) settings to evaluate their impact on the Doppler measurements. RESULTS: Ten sets of cine clips were analyzed for this study. The pulsatile nature of the vascularity was readily apparent in each cine clip. The measured time-vascularity waveforms showed uniform cyclic variation in vascularity over the cardiac cycle, with systolic vascularity significantly higher than diastolic vascularity at each combination of PRF and WMF (P < .05). A gradual increase in the vascular pulsatility index was observed with an increasing PRF or WMF. Normalization of systolic-to-diastolic measurement provided a stable vascular assessment across the range of PRFs. CONCLUSIONS: Doppler cine clips provide a dynamic representation of the placental bed vasculature and a novel analytic approach to quantitatively evaluating the pulsatility of this critical vascular network. Further work is warranted to explore the reproducibility and clinical potential of this approach.


Asunto(s)
Placenta/diagnóstico por imagen , Placenta/fisiología , Flujo Pulsátil/fisiología , Ultrasonografía Doppler/métodos , Resistencia Vascular/fisiología , Adulto , Velocidad del Flujo Sanguíneo/fisiología , Estudios de Cohortes , Estudios de Evaluación como Asunto , Estudios de Factibilidad , Femenino , Humanos , Embarazo , Reproducibilidad de los Resultados , Adulto Joven
12.
J Ultrasound Med ; 38(8): 2025-2038, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30560547

RESUMEN

OBJECTIVES: To investigate whether quantitative contrast-enhanced ultrasound (CEUS) can accurately identify neonates and infants with hypoxic ischemic brain injury. METHODS: In this prospective cohort study, 8 neonates and infants with a suspicion of hypoxic ischemic injury were evaluated with CEUS. RESULTS: An interesting trend was observed in the central gray nuclei-to-cortex perfusion ratios. The ratios at the peak enhancement, wash-in area under the curve, perfusion index, and maximum wash-in slopes were lower in all of the affected cases compared to the normal group but not statistically significant given the small sample size (P = .0571). Additionally, when the central gray nuclei-to-cortex perfusion ratio was plotted for all time points along the time-intensity curve, it was observed that the affected cases showed a trend that was qualitatively different from that of the normal cases. In the affected cases, the ratio time-intensity curves either stayed below 1.0 for the entire enhancement period or reached 1.0 close to peak wash-in before falling just below 1.0 for the remaining period of enhancement. However, in the unaffected patients, there was a steep wash-in that crossed the 1.0 threshold and remained above 1.0 for most of the enhancement period. CONCLUSIONS: Bedside CEUS is an easily obtainable brain-imaging modality that has the potential to effectively identify infants and neonates with evolving brain injury. A larger prospective study evaluating the correlation between CEUS findings and the reference standard of diffusion- and perfusion-weighted magnetic resonance imaging is needed to establish it as a diagnostic tool.


Asunto(s)
Medios de Contraste , Hipoxia-Isquemia Encefálica/diagnóstico por imagen , Aumento de la Imagen/métodos , Ultrasonografía/métodos , Encéfalo/diagnóstico por imagen , Estudios de Cohortes , Estudios de Evaluación como Asunto , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados
13.
Ultrason Imaging ; 41(5): 290-300, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31322030

RESUMEN

Peripheral artery disease is often asymptomatic, and various imaging and nonimaging techniques have been used for assessment and monitoring treatments. This study is designed to demonstrate the ability of photoacoustic imaging to noninvasively determine changes in tissue oxygenation that occur in mice's hind limb skeletal muscle as they age. Mice from two age cohorts were scanned bilaterally with a pulsed laser. The photoacoustic signal was unmixed to generate a parametric map of estimated oxygen saturation and then overlaid on grayscale ultrasound images. Tissue oxygenation measured in young and old mice was compared. Photoacoustic imaging visually and quantitatively showed the decrease in skeletal muscle oxygenation that occurs with age. Percent tissue oxygenation decreased from 30.2% to 3.5% (p < 0.05). This reduction corresponded to reduced fractional area of oxygenation, which decreased from 60.6% to 6.0% (p < 0.05). The change in oxygenation capacity of the still active vascular regions was insignificant (p > 0.05). Intrasubject, intra-, and interobserver comparisons showed low variability in measurements, exhibited by high regression and intraclass correlations exceeding 0.81 for all ages. The decrease in oxygenation detected by photoacoustic imaging paralleled the known oxygenation decrease observed in aging tissues, demonstrating that photoacoustic imaging can assess age-related changes in a mouse calf muscle. These intramuscular changes could potentially act as a strong diagnostic marker for peripheral artery disease. This study thus opens the doors for a novel, affordable, noninvasive method of evaluation free of radiation or exogenous material.


Asunto(s)
Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/metabolismo , Oxígeno/metabolismo , Enfermedad Arterial Periférica/metabolismo , Técnicas Fotoacústicas/métodos , Ultrasonografía/métodos , Factores de Edad , Animales , Modelos Animales de Enfermedad , Ratones , Ratones Desnudos , Enfermedad Arterial Periférica/diagnóstico
14.
Vasc Med ; 21(4): 317-24, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26994006

RESUMEN

The object of this study was to utilize a novel feed-forward active contour (FFAC) algorithm to find a reproducible technique for analysis of brachial artery reactivity. Flow-mediated dilation (FMD) is an important marker of vascular endothelial function but has not been adopted for widespread clinical use given its technical limitations, including inter-observer variability and differences in technique across clinical sites. We developed a novel FFAC algorithm with the goal of validating a more reliable standard. Forty-six healthy volunteers underwent FMD measurement according to the standard technique. Ultrasound videos lasting 5-10 seconds each were obtained pre-cuff inflation and at minutes 1 through 5 post-cuff deflation in longitudinal and transverse views. Automated segmentation using the FFAC algorithm with initial boundary definition from three different observers was used to analyze the images to measure diameter/cross-sectional area over the cardiac cycle. The %FMD was calculated for average, minimum, and maximum diameters/areas. Using the FFAC algorithm, the population-specific coefficient of variation (CV) at end-diastole was 3.24% for transverse compared to 9.96% for longitudinal measurements; the subject-specific CV was 15.03% compared to 57.41%, respectively. For longitudinal measurements made via the conventional method, the population-specific CV was 4.77% and subject-specific CV was 117.79%. The intraclass correlation coefficient (ICC) for transverse measurements was 0.97 (95% CI: 0.95-0.98) compared to 0.90 (95% CI: 0.84-0.94) for longitudinal measurements with FFAC and 0.72 (95% CI: 0.51-0.84) for conventional measurements. In conclusion, transverse views using the novel FFAC method provide less inter-observer variability than traditional longitudinal views. Improved reproducibility may allow adoption of FMD testing in a clinical setting. The FFAC algorithm is a robust technique that should be evaluated further for its ability to replace the more limited conventional technique for measurement of FMD.


Asunto(s)
Algoritmos , Arteria Braquial/diagnóstico por imagen , Enfermedades Cardiovasculares/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Ultrasonografía/métodos , Vasodilatación , Adolescente , Adulto , Anciano , Arteria Braquial/fisiopatología , Enfermedades Cardiovasculares/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo , Adulto Joven
15.
J Clin Ultrasound ; 44(9): 580-586, 2016 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-27447717

RESUMEN

PURPOSE: The objectives of our study were to assess the accuracy of hepatorenal index (HRI) in detection and grading of hepatic steatosis and to evaluate various factors that can affect the HRI measurement. METHODS: Forty-five patients, who had undergone an abdominal sonographic examination within 30 days of liver biopsy, were enrolled. The HRI was calculated as the ratio of the mean brightness levels of the liver and renal parenchymas. The effect of the measurement technique on the HRI was evaluated by using various sizes, depths, and locations of the regions of interest (ROIs) in the liver. The measurements were obtained by two observers. The HRI was compared with the subjective grading of steatosis. RESULTS: The optimal HRI cutoff to detect steatosis was 2.01, yielding a sensitivity of 62.5% and specificity of 95.2%. Subjective grading had a sensitivity of 87.5% and specificity of 62.5%. HRIs of the hepatic steatosis group were statistically different from the no-steatosis group (p < 0.05). However, there was no statistically significant difference between mild steatosis and no-steatosis groups (p value = 0.72). There was a strong correlation between different HRIs based on variable placements of ROIs, except when the ROIs were positioned randomly. Interclass correlation coefficient for measurements performed by two observers was 0.74 (confidence interval: 0.58-0.86). CONCLUSIONS: The HRI is an effective tool for detecting hepatic steatosis. It provides similar accuracy for different methods of ROI placement (except for random placement) and has good interobserver agreement. It, however, is unable to effectively differentiate between absent and mild steatosis. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 44:580-586, 2016.


Asunto(s)
Hígado Graso/diagnóstico por imagen , Hígado Graso/patología , Ultrasonografía/métodos , Adulto , Anciano , Femenino , Humanos , Riñón/diagnóstico por imagen , Riñón/patología , Hígado/diagnóstico por imagen , Hígado/patología , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Adulto Joven
16.
Oncologist ; 20(8): 952-9, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26084808

RESUMEN

BACKGROUND: Vascular endothelial growth factor and platelet-derived growth factor signaling in the tumor microenvironment appear to cooperate in promoting tumor angiogenesis. PATIENTS AND METHODS: We conducted a phase I trial combining bevacizumab (i.v. every 2 weeks) and imatinib (oral daily). Once a recommended phase II dose combination was established, a phase II trial was initiated in patients with metastatic melanoma. A Simon 2-stage design was used with 23 patients required in the first stage and 41 patients in total should the criteria to proceed be met. We required that 50% of the patients be progression-free at 16 weeks. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and power Doppler ultrasonography were performed in patients with metastatic tumors amenable to imaging with these methods at baseline and after 4 weeks. RESULTS: A total of 17 patients were accrued to 4 dose and combination levels. Bevacizumab 10 mg/kg every 2 weeks could be safely combined with imatinib 800 mg daily. Common toxicities included fatigue, nausea, vomiting, edema, proteinuria, and anemia, but were not commonly severe. A total of 23 patients with metastatic melanoma (48% with American Joint Commission on Cancer stage M1c; median age, 63 years) were enrolled in the first stage of phase II. The 16-week progression-free survival rate was 35%, leading to termination of phase II after the first stage. In the small subset of patients who remained on study with lesions evaluable by DCE-MRI, significant decreases in tumor vascular permeability were noted, despite early disease progression using the Response Evaluation Criteria In Solid Tumors. CONCLUSION: Bevacizumab and imatinib can be safely combined at the maximum doses used for each agent. We did not observe significant clinical activity with this regimen in melanoma patients.


Asunto(s)
Antineoplásicos/uso terapéutico , Bevacizumab/uso terapéutico , Mesilato de Imatinib/uso terapéutico , Melanoma/tratamiento farmacológico , Adulto , Anciano , Antineoplásicos/administración & dosificación , Bevacizumab/administración & dosificación , Supervivencia sin Enfermedad , Femenino , Humanos , Mesilato de Imatinib/administración & dosificación , Masculino , Persona de Mediana Edad
17.
J Vasc Surg ; 61(4): 1034-40, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24388698

RESUMEN

OBJECTIVE: Aortic wall thickness (AWT) is important for anatomic description and biomechanical modeling of aneurysmal disease. However, no validated, noninvasive method for measuring AWT exists. We hypothesized that semiautomated image segmentation algorithms applied to computed tomography angiography (CTA) can accurately measure AWT. METHODS: Aortic samples from 10 patients undergoing open thoracoabdominal aneurysm repair were taken from sites of the proximal or distal anastomosis, or both, yielding 13 samples. Aortic specimens were fixed in formalin, embedded in paraffin, and sectioned. After staining with hematoxylin and eosin and Masson's trichrome, sections were digitally scanned and measured. Patients' preoperative CTA Digital Imaging and Communications in Medicine (DICOM; National Electrical Manufacturers Association, Rosslyn, Va) images were segmented into luminal, inner arterial, and outer arterial surfaces with custom algorithms using active contours, isoline contour detection, and texture analysis. AWT values derived from image data were compared with measurements of corresponding pathologic specimens. RESULTS: AWT determined by CTA averaged 2.33 ± 0.66 mm (range, 1.52-3.55 mm), and the AWT of pathologic specimens averaged 2.36 ± 0.75 mm (range, 1.51-4.16 mm). The percentage difference between pathologic specimens and CTA-determined AWT was 9.5% ± 4.1% (range, 1.8%-16.7%). The correlation between image-based measurements and pathologic measurements was high (R = 0.935). The 95% limits of agreement computed by Bland-Altman analysis fell within the range of -0.42 and 0.42 mm. CONCLUSIONS: Semiautomated analysis of CTA images can be used to accurately measure regional and patient-specific AWT, as validated using pathologic ex vivo human aortic specimens. Descriptions and reconstructions of aortic aneurysms that incorporate locally resolved wall thickness are feasible and may improve future attempts at biomechanical analyses.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aortografía/métodos , Tomografía Computarizada Multidetector , Interpretación de Imagen Radiográfica Asistida por Computador , Anciano , Algoritmos , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Automatización , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
18.
J Cardiovasc Magn Reson ; 17: 19, 2015 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-25884943

RESUMEN

BACKGROUND: Both age and smoking promote endothelial dysfunction and impair vascular reactivity. Here, we tested this hypothesis by quantifying new cardiovascular magnetic resonance (CMR)-based biomarkers in smokers and nonsmokers. METHODS: Study population: young non-smokers (YNS: N = 45, mean age = 30.2 ± 0.7 years), young smokers (YS: N = 39 mean age 32.1 ± 0.7 years), older non-smokers (ONS: N = 45, mean age = 57.8 ± 0.6 years), and older smokers (OS: N = 40, mean age = 56.3 ± 0.6 years), all without overt cardiovascular disease. Vascular reactivity was evaluated following cuff-induced hyperemia via time-resolved blood flow velocity and oxygenation (SvO2) in the femoral artery and vein, respectively. SvO2 dynamics yielded washout time (time to minimum SvO2), resaturation rate (upslope) and maximum change from baseline (overshoot). Arterial parameters included pulse ratio (PR), hyperemic index (HI) and duration of hyperemia (TFF). Pulse-wave velocity (PWV) was assessed in aortic arch, thoracoabdominal aorta and iliofemoral arteries. Ultrasound-based carotid intimal-medial thickness (IMT) and brachial flow-mediated dilation were measured for comparison. RESULTS: Age and smoking status were independent for all parameters. Smokers had reduced upslope (-28.4%, P < 0.001), increased washout time (+15.3%, P < 0.01), and reduced HI (-19.5%, P < 0.01). Among non-smokers, older subjects had lower upslope (-22.7%, P < 0.01) and overshoot (-29.4%, P < 0.01), elevated baseline pulse ratio (+14.9%, P < 0.01), central and peripheral PWV (all P < 0.05). Relative to YNS, YS had lower upslope (-23.6%, P < 0.01) and longer washout time (13.5%, P < 0.05). Relative to ONS, OS had lower upslope (-33.0%, P < 0.01). IMT was greater in ONS than in YNS (+45.6%, P < 0.001), and also in YS compared to YNS (+14.7%, P < 0.05). CONCLUSIONS: Results suggest CMR biomarkers of endothelial function to be sensitive to age and smoking independent of each other.


Asunto(s)
Aorta/fisiopatología , Endotelio Vascular/fisiopatología , Arteria Femoral/fisiopatología , Vena Femoral/fisiopatología , Arteria Ilíaca/fisiopatología , Imagen por Resonancia Magnética/métodos , Fumar/efectos adversos , Adulto , Factores de Edad , Anciano , Velocidad del Flujo Sanguíneo , Arteria Braquial/diagnóstico por imagen , Arteria Braquial/fisiopatología , Arteria Carótida Común/diagnóstico por imagen , Arteria Carótida Común/fisiopatología , Grosor Intima-Media Carotídeo , Femenino , Humanos , Hiperemia/fisiopatología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Análisis de la Onda del Pulso , Flujo Sanguíneo Regional , Factores de Riesgo , Ultrasonografía Doppler , Vasodilatación
20.
J Ultrasound Med ; 34(2): 275-87, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25614401

RESUMEN

OBJECTIVES: The purpose of this study was to investigate the treatment effects of antivascular ultrasound (US) with dynamic contrast-enhanced magnetic resonance imaging (MRI), contrast-enhanced sonography, and histopathologic analysis in a murine melanoma model. METHODS: Subcutaneous K1735 murine melanoma tumors were grown in syngeneic C3H/HeN mice. Quantitative tumor perfusion characteristics were measured before antivascular US treatment with both dynamic contrast-enhanced MRI and high-resolution contrast-enhanced sonography. Tumors were subsequently treated with 1 or 3 minutes of continuous low-intensity US after intravenous administration of a US contrast agent. Treatment effects were assessed by quantitative dynamic contrast-enhanced MRI, contrast-enhanced sonography, histopathologic analysis, and immunohistochemistry. RESULTS: Low-intensity antivascular US treatment resulted in approximately a doubling and tripling of the time to peak enhancement on dynamic contrast-enhanced MRI in the 1- and 3-minute treatment groups, respectively, along with a significant decrease in contrast wash-out (P < .01). There was a potent reduction in tumor perfusion on contrast-enhanced sonography, with approximately 40% and 70% reductions in the tumor area perfused as assessed by contrast-enhanced sonography after 1 (P < .05) and 3 (P < .01) minutes of antivascular US. The pathologic and histologic changes spatially correlated with the regions of diminished perfusion seen on contrast-enhanced sonography and dynamic contrast-enhanced MRI. Antivascular US therapy resulted in a significant increase in the number of hypoxia-inducible factor 1A(+) cells, indicating tumor hypoxia (P < .01), and of CD45(+)/CD3(+) cells in tumors after treatment, in keeping with increased T-cell infiltration (P < .01). CONCLUSIONS: Antivascular US treatment effects extend beyond direct cytotoxicity from hemorrhagic necrosis to include ischemia-mediated cytotoxicity, enhanced small molecule retention, and intratumoral immune activation.


Asunto(s)
Biomarcadores de Tumor/inmunología , Melanoma/patología , Melanoma/terapia , Neovascularización Patológica/patología , Neovascularización Patológica/terapia , Terapia por Ultrasonido/métodos , Animales , Línea Celular Tumoral , Angiografía por Resonancia Magnética/métodos , Melanoma/inmunología , Ratones , Ratones Endogámicos C3H , Neovascularización Patológica/inmunología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA