Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Artif Organs ; 42(4): 365-376, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28940550

RESUMEN

The objective of this study was to evaluate the hemodynamic performance and gaseous microemboli (GME) handling ability of a simulated neonatal extracorporeal life support (ECLS) circuit with an in-line continuous renal replacement therapy (CRRT) device. The circuit consisted of a Maquet RotaFlow centrifugal pump or HL20 roller pump, Quadrox-iD Pediatric diffusion membrane oxygenator, 8-Fr arterial cannula, 10-Fr venous cannula, and Better-Bladder (BB) with "Y" connector. A second Quadrox-I Adult oxygenator was added postarterial cannula for GME experiments. The circuit and pseudo-patient were primed with lactated Ringer's solution and packed human red blood cells (hematocrit 40%). All hemodynamic trials were conducted at ECLS flow rates ranging from 200 to 600 mL/min and CRRT flow rate of 75 mL/min at 36°C. Real-time pressure and flow data were recorded with a data acquisition system and GME were detected and characterized using the Emboli Detection and Classification Quantifier System. CRRT was added at distinct locations such that blood entered CRRT between the pump and oxygenator (A), recirculated through the pump (B), or bypassed the pump (C). With the centrifugal pump, all CRRT positions had similar flow rates, mean arterial pressure (MAP), and total hemodynamic energy (THE) loss. With the roller pump, C demonstrated increased flow rates (293.2-686.4 mL/min) and increased MAP (59.4-75.5 mm Hg) (P < 0.01); B had decreased flow rates (129.7-529.7 mL/min), and MAP (34.2-45.0 mm Hg) (P < 0.01); A maintained the same when compared to without CRRT. At 600 mL/min C lost more THE (81.4%) (P < 0.01) with a larger pressure drop across the oxygenator (95.6 mm Hg) (P < 0.01) than without CRRT (78.3%; 49.1 mm Hg) (P < 0.01). C also demonstrated a poorer GME handling ability using the roller pump, with 87.1% volume and 17.8% count reduction across the circuit, compared to A and B with 99.9% volume and 65.8-72.3% count reduction. These findings suggest that, in contrast to A and B, adding CRRT at position C is unsafe and not advised for clinical use.


Asunto(s)
Embolia Aérea/prevención & control , Oxigenación por Membrana Extracorpórea/métodos , Sistemas de Manutención de la Vida/instrumentación , Modelos Cardiovasculares , Diálisis Renal/métodos , Terapia de Reemplazo Renal/métodos , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/instrumentación , Gases , Hemofiltración/efectos adversos , Hemofiltración/instrumentación , Hemofiltración/métodos , Hemorreología , Humanos , Recién Nacido , Oxigenadores de Membrana , Diálisis Renal/efectos adversos , Diálisis Renal/instrumentación , Terapia de Reemplazo Renal/efectos adversos , Terapia de Reemplazo Renal/instrumentación
2.
JAMA Oncol ; 10(10): 1409-1416, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39207773

RESUMEN

Importance: Immune checkpoint inhibitors (ICIs) have revolutionized cancer care; however, accompanying immune-related adverse events (irAEs) confer substantial morbidity and occasional mortality. Life-threatening irAEs may require permanent cessation of ICI, even in patients with positive tumor response. Therefore, it is imperative to comprehensively define the spectrum of irAEs to aid individualized decision-making around the initiation of ICI therapy. Objective: To define incidence, risk factors, and clinical spectrum of an irreversible and life-threatening irAE: ICI-induced diabetes. Design, Setting, and Participants: This cohort study, conducted at an academic integrated health care system examined 14 328 adult patients treated with ICIs, including 64 patients who developed ICI-induced diabetes, from July 2010 to January 2022. The data were analyzed from 2022 to 2023. Cases of ICI-induced diabetes were manually confirmed; detailed clinical phenotyping was performed at diagnosis and 1-year follow-up. For 862 patients, genotyping data were available, and polygenic risk for type 1 diabetes was determined. Main Outcomes and Measures: For ICI-induced diabetes cases and controls, demographic characteristics, comorbidities, tumor category, and ICI category were compared. Among ICI-induced diabetes cases, markers of glycemic physiology were examined at diagnosis and 1-year follow-up. For patients with available genotyping, a published type 1 diabetes polygenic score (T1D GRS2) was calculated. Results: Of 14 328 participants, 6571 (45.9%) were women, and the median (range) age was 66 (8-106) years. The prevalence of ICI-induced diabetes among ICI-treated patients was 0.45% (64 of 14 328), with an incidence of 124.8 per 100 000 person-years. Preexisting type 2 diabetes (odds ratio [OR], 5.91; 95% CI, 3.34-10.45) and treatment with combination ICI (OR, 2.57; 95% CI, 1.44-4.59) were significant clinical risk factors of ICI-induced diabetes. T1D GRS2 was associated with ICI-induced diabetes risk, with an OR of 4.4 (95% CI, 1.8-10.5) for patients in the top decile of T1D GRS2, demonstrating a genetic association between spontaneous autoimmunity and irAEs. Patients with ICI-induced diabetes were in 3 distinct phenotypic categories based on autoantibodies and residual pancreatic function, with varying severity of initial presentation. Conclusions and Relevance: The results of this analysis of 14 328 ICI-treated patients followed up from ICI initiation determined the incidence, risk factors and clinical spectrum of ICI-induced diabetes. Widespread implementation of this approach across organ-specific irAEs may enhance diagnosis and management of these conditions, and this becomes especially pertinent as ICI treatment rapidly expands to treat a wide spectrum of cancers and is used at earlier stages of treatment.


Asunto(s)
Inhibidores de Puntos de Control Inmunológico , Humanos , Inhibidores de Puntos de Control Inmunológico/efectos adversos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Factores de Riesgo , Neoplasias/tratamiento farmacológico , Adulto , Diabetes Mellitus/inducido químicamente , Diabetes Mellitus/epidemiología , Incidencia , Anciano de 80 o más Años , Diabetes Mellitus Tipo 1/inducido químicamente , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Estudios de Cohortes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA