Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Nature ; 622(7983): 471-475, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37758953

RESUMEN

Resonant oscillators with stable frequencies and large quality factors help us to keep track of time with high precision. Examples range from quartz crystal oscillators in wristwatches to atomic oscillators in atomic clocks, which are, at present, our most precise time measurement devices1. The search for more stable and convenient reference oscillators is continuing2-6. Nuclear oscillators are better than atomic oscillators because of their naturally higher quality factors and higher resilience against external perturbations7-9. One of the most promising cases is an ultra-narrow nuclear resonance transition in 45Sc between the ground state and the 12.4-keV isomeric state with a long lifetime of 0.47 s (ref. 10). The scientific potential of 45Sc was realized long ago, but applications require 45Sc resonant excitation, which in turn requires accelerator-driven, high-brightness X-ray sources11 that have become available only recently. Here we report on resonant X-ray excitation of the 45Sc isomeric state by irradiation of Sc-metal foil with 12.4-keV photon pulses from a state-of-the-art X-ray free-electron laser and subsequent detection of nuclear decay products. Simultaneously, the transition energy was determined as [Formula: see text] with an uncertainty that is two orders of magnitude smaller than the previously known values. These advancements enable the application of this isomer in extreme metrology, nuclear clock technology, ultra-high-precision spectroscopy and similar applications.

2.
J Synchrotron Radiat ; 31(Pt 4): 751-762, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38904936

RESUMEN

A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation. CBXFEL cavities require low-loss wavefront-preserving optical components: near-100%-reflectivity X-ray diamond Bragg-reflecting crystals, outcoupling devices such as thin diamond membranes or X-ray gratings, and aberration-free focusing elements. In the framework of the collaborative CBXFEL research and development project of Argonne National Laboratory, SLAC National Accelerator Laboratory and SPring-8, we report here the design, manufacturing and characterization of X-ray optical components for the CBXFEL cavity, which include high-reflectivity diamond crystal mirrors, a diamond drumhead crystal with thin membranes, beryllium refractive lenses and channel-cut Si monochromators. All the designed optical components have been fully characterized at the Advanced Photon Source to demonstrate their suitability for the CBXFEL cavity application.

3.
Exp Brain Res ; 240(12): 3141-3152, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36241746

RESUMEN

Existing methods for measuring implicit sequence-learning consciousness are conducted offline. Based on the traditional measurement of cued-generation task, this study implemented an online measurement method by converting a generation task into a forced-choice task to observe the dynamic changes of consciousness in the implicit sequence-learning process. In this study, we compared the performance of online measurement task and traditional sequence-learning tasks in 31 university students. The results revealed that the online indicators were significantly correlated with classic consciousness indicators and typical ERP components of consciousness. Without affecting the development of consciousness, the online measurement indicators were found to promptly and effectively reflect the gradually changing progression of consciousness in implicit sequence learning.


Asunto(s)
Estado de Conciencia , Aprendizaje Seriado , Análisis y Desempeño de Tareas , Humanos , Estado de Conciencia/fisiología , Señales (Psicología) , Internet , Aprendizaje/fisiología , Tiempo de Reacción/fisiología , Aprendizaje Seriado/fisiología , Estudiantes , Desempeño Psicomotor/fisiología
4.
Exp Brain Res ; 239(4): 1151-1163, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33555381

RESUMEN

Combined with the prime paradigm, the present study aimed to explore the influence of emotion (anger, fear, happiness, and neutral) on performing multiplication estimation. Participants were asked to complete a two-digit multiplication estimation task using the down-up strategy (e.g., doing 20 × 80 = 1600 for 24 × 79). Behavioral results showed that the reaction time for completing multiplication estimation tasks under happy conditions was shorter than for those under anger and fear, and it was shorter under neutral than under fearful conditions. The ERP results showed that about 100 ms after multiplication estimation task onset, multiplication estimation execution in the context of happiness (vs. neutral) elicited smaller P1 amplitudes; about 170 ms after multiplication estimation task onset, the N170 amplitudes elicited by multiplication estimation strategy execution under different emotional priming conditions showed no significant differences. The above results showed that the impact of emotion priming demonstrates the occurrence of a dynamic process when participants use a specified strategy to complete the multiplication estimation task. The present study revealed that emotional valence modulated arithmetic strategy execution, suggesting the role of different emotions should be fully considered in similar study.


Asunto(s)
Emociones , Expresión Facial , Electroencefalografía , Potenciales Evocados , Miedo , Felicidad , Humanos
5.
J Synchrotron Radiat ; 27(Pt 6): 1553-1563, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33147180

RESUMEN

Wavefront-preserving X-ray diamond crystal optics are essential for numerous applications in X-ray science. Perfect crystals with flat Bragg planes are a prerequisite for wavefront preservation in Bragg diffraction. However, this condition is difficult to realize in practice because of inevitable crystal imperfections. Here, X-ray rocking curve imaging is used to study the smallest achievable Bragg-plane slope errors in the best presently available synthetic diamond crystals and how they compare with those of perfect silicon crystals. It is shown that the smallest specific slope errors in the best diamond crystals are about 0.08 (3) µrad mm-2. These errors are only 50% larger than the 0.05 (2) µrad mm-2 specific slope errors measured in perfect silicon crystals. High-temperature annealing at 1450°C of almost flawless diamond crystals reduces the slope errors very close to those of silicon. Further investigations are in progress to establish the wavefront-preservation properties of these crystals.

6.
J Synchrotron Radiat ; 26(Pt 4): 1101-1109, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31274433

RESUMEN

A wake monochromator based on a large-area diamond single crystal for hard X-ray self-seeding has been successfully installed and commissioned in the hard X-ray free-electron laser (FEL) at the Pohang Accelerator Laboratory with international collaboration. For this commissioning, the self-seeding was demonstrated with a low bunch charge (40 pC) and the nominal bunch charge (180 pC) of self-amplified spontaneous emission (SASE) operation. The FEL pulse lengths were estimated as 7 fs and 29.5 fs, respectively. In both cases, the average spectral brightness increased by more than three times compared with the SASE mode. The self-seeding experiment was demonstrated for the first time using a crystal with a thickness of 30 µm, and a narrow bandwidth of 0.22 eV (full width at half-maximum) was obtained at 8.3 keV, which confirmed the functionality of a crystal with such a small thickness. In the nominal bunch-charge self-seeding experiment, the histogram of the intensity integrated over a 1 eV bandwidth showed a well defined Gaussian profile, which is evidence of the saturated FEL and a minimal electron-energy jitter (∼1.2 × 10-4) effect. The corresponding low photon-energy jitter (∼2.4 × 10-4) of the SASE FEL pulse, which is two times lower than the Pierce parameter, enabled the seeding power to be maximized by maintaining the spectral overlap between SASE FEL gain and the monochromator.

7.
J Synchrotron Radiat ; 25(Pt 4): 1022-1029, 2018 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-29979163

RESUMEN

X-ray free-electron lasers in the oscillator configuration (XFELO) are future fully coherent hard X-rays sources with ultrahigh spectral purity. X-ray beams circulate in an XFELO optical cavity comprising diamond single crystals. They function as high-reflectance (close to 100%), narrowband (∼10 meV) Bragg backscattering mirrors. The average power density of the X-ray beams in the XFELO cavity is predicted to be as high as ∼10 kW mm-2. Therefore, XFELO feasibility relies on the ability of diamond crystals to withstand such a high radiation load and preserve their high reflectivity. Here the endurance of diamond crystals to irradiation with multi-kW mm-2 power density X-ray beams is studied. It is shown that the high Bragg reflectivity of the diamond crystals is preserved after the irradiation, provided it is performed at ∼1 × 10-8 Torr high-vacuum conditions. Irradiation under 4 × 10-6 Torr results in a ∼1 meV shift of the Bragg peak, which corresponds to a relative lattice distortion of 4 × 10-8, while the high Bragg reflectivity stays intact.

9.
Opt Express ; 23(21): 27990-7, 2015 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-26480457

RESUMEN

We report on the characterization of a multilayer Laue lens (MLL) with large acceptance, made of a novel WSi2/Al bilayer system. Fabrication of multilayers with large deposition thickness is required to obtain MLL structures with sufficient apertures capable of accepting the full lateral coherence length of x-rays at typical nanofocusing beamlines. To date, the total deposition thickness has been limited by stress-buildup in the multilayer. We were able to grow WSi2/Al with low grown-in stress, and asses the degree of stress reduction. X-ray diffraction experiments were conducted at beamline 1-BM at the Advanced Photon Source. We used monochromatic x-rays with a photon energy of 12 keV and a bandwidth of ΔE/E=5.4·10(-4). The MLL was grown with parallel layer interfaces, and was designed to have a large focal length of 9.6 mm. The mounted lens was 2.7 mm in width. We found and quantified kinks and bending of sections of the MLL. Sections with bending were found to partly have a systematic progression in the interface angles. We observed kinking in some, but not all, areas. The measurements are compared with dynamic diffraction calculations made with Coupled Wave Theory. Data are plotted showing the diffraction efficiency as a function of the external tilting angle of the entire mounted lens. This way of plotting the data was found to provide an overview into the diffraction properties of the whole lens, and enabled the following layer tilt analyses.

10.
J Synchrotron Radiat ; 21(Pt 4): 662-8, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24971959

RESUMEN

The micro-focusing performance for hard X-rays of a fixed-geometry elliptical Kirkpatrick-Baez (K-B) mirrors assembly fabricated, tested and finally implemented at the micro-probe beamline 8-BM of the Advanced Photon Source is reported. Testing of the K-B mirror system was performed at the optics and detector test beamline 1-BM. K-B mirrors of length 80 mm and 60 mm were fabricated by profile coating with Pt metal to produce focal lengths of 250 mm and 155 mm for 3 mrad incident angle. For the critical angle of Pt, a broad bandwidth of energies up to 20 keV applies. The classical K-B sequential mirror geometry was used, and mirrors were mounted on micro-translation stages. The beam intensity profiles were measured by differentiating the curves of intensity data measured using a wire-scanning method. A beam size of 1.3 µm (V) and 1.2 µm (H) was measured with monochromatic X-rays of 18 keV at 1-BM. After installation at 8-BM the measured focus met the design requirements. In this paper the fabrication and metrology of the K-B mirrors are reported, as well as the focusing performances of the full mirrors-plus-mount set-up at both beamlines.

11.
Opt Express ; 22(23): 28142-53, 2014 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-25402054

RESUMEN

Focusing efficiency of Fresnel zone plates (FZPs) for X-rays depends on zone height, while the achievable spatial resolution depends on the width of the finest zones. FZPs with optimal efficiency and sub-100-nm spatial resolution require high aspect ratio structures which are difficult to fabricate with current technology especially for the hard X-ray regime. A possible solution is to stack several zone plates. To increase the number of FZPs within one stack, we first demonstrate intermediate-field stacking and apply this method by stacks of up to five FZPs with adjusted diameters. Approaching the respective optimum zone height, we maximized efficiencies for high resolution focusing at three different energies, 10, 11.8, and 25 keV.


Asunto(s)
Lentes , Refractometría/instrumentación , Dispersión de Radiación , Difracción de Rayos X/instrumentación , Diseño de Equipo , Rayos X
12.
Front Psychol ; 15: 1350358, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38911956

RESUMEN

Introduction: Affective decision-making is a prominent topic in consumer psychology research, with its core assumption being that consumers tend to purchase brands and commodities they like. However, the reasons behind why we develop emotional responses of liking or disliking toward certain commodities, as well as what the underlying neural mechanisms are, remain largely unknown. Methods: This study utilized the S1-S2 paradigm in an experiment wherein S1 presented 12 types of commodities and S2 displayed 48 distinct colored squares. Participants were instructed to assess whether they "Like" or "Dislike" the commodity in S1, which was colored with the S2 color. Electroencephalogram (EEG) recordings were obtained during the reaction process and subsequently analyzed to examine the components of S2-induced event-related potentials (ERPs). Results: The analysis revealed that S2 elicited a significant N270 in the prefrontal scalp area under both the "Like" and "Dislike" conditions. Interestingly, the amplitude of the N270 was significantly higher during the "Dislike" condition compared to the "Like" condition. Discussion: The N270 component was shown to reflect the conflict in physical attributes between S1 and S2, as well as the conflict between commodity and color. This highlights the potential utility of this component as an objective EEG indicator of consumer commodity color preferences in future marketing research.

13.
Behav Sci (Basel) ; 14(3)2024 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-38540505

RESUMEN

The objective of this study was to examine the intervention effect of group sensory integration training on social responsiveness, and the latency and amplitude of N170 event-related potential of children with autism. The social responsiveness scale was employed to assess alterations in the social response of individuals with ASD before and after training, while event-related potentials were utilized to measure changes in N170 latency and amplitude. This study revealed that group sensory integration training can significantly enhance social responsiveness in children diagnosed with ASD. Children with ASD exhibit atypical N170 responses to faces in the right parietal region. The latency of N170 changes may serve as a valuable indicator for assessing the effectiveness of an intervention or diagnosing ASD.

14.
J Synchrotron Radiat ; 19(Pt 6): 1056-60, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23093770

RESUMEN

The Hard X-ray Nanoprobe Beamline (or Nanoprobe Beamline) is an X-ray microscopy facility incorporating diffraction, fluorescence and full-field imaging capabilities designed and operated by the Center for Nanoscale Materials and the Advanced Photon Source at Sector 26 of the Advanced Photon Source at Argonne National Laboratory. This facility was constructed to probe the nanoscale structure of biological, environmental and material sciences samples. The beamline provides intense focused X-rays to the Hard X-ray Nanoprobe (or Nanoprobe) which incorporates Fresnel zone plate optics and a precision laser sensing and control system. The beamline operates over X-ray energies from 3 to 30 keV, enabling studies of most elements in the periodic table, with a particular emphasis on imaging transition metals.

15.
Front Hum Neurosci ; 16: 894702, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36569473

RESUMEN

Microexpressions are very transitory expressions lasting about 1/25∼1/2 s, which can reveal people's true emotions they try to hide or suppress. The PREMERT (pseudorandom ecological microexpression recognition test) could test the individual's microexpression recognition ability with six microexpression Ms (the mean of accuracy rates of a microexpression type under six expression backgrounds), and six microexpression SDs (the standard deviation of accuracy rates of this microexpression type under six expression backgrounds), but it and other studies did not explore the general microexpression recognition ability (the GMERA) or could not test the GMERA effectively. Therefore, the current study put forward and established the GMERA with the behavioral data of the PREMERT. The spontaneous brain activity in the resting state is a stable index to measure individual cognitive characteristics. Therefore, the current study explored the relevant resting-state brain activity of the GMERA indicators to prove that GMERA is an individual cognitive characteristic from brain mechanisms with the neuroimaging data of the PREMERT. The results showed that (1) there was a three-layer hierarchical structure in human microexpression recognition ability: The GMERA (the highest layer); recognition of a type of microexpression under different expression backgrounds (the second layer); and recognition of a certain microexpression under a certain expression background (the third layer). A common factor GMERA was extracted from the six microexpression types recognition in PREMERT. Four indicators of the GMERA were calculated from six microexpression Ms and six microexpression SDs, such as GMERAL (level of GMERA), GMERAF (fluctuation of GMERA), GMERAB (background effect of GMERA), and GMERABF (fluctuation of GMERAB), which had good parallel-forms reliability, calibration validity, and ecological validity. The GMERA provided a concise and comprehensive overview of the individual's microexpression recognition ability. The PREMERT was proved as a good test to measure the GMERA. (2) ALFFs (the amplitude of low-frequency fluctuations) in both eyes-closed and eyes-opened resting-states and ALFFs-difference could predict the four indicators of the GMERA. The relevant resting-state brain areas were some areas of the expression recognition network, the microexpression consciousness and attention network, and the motor network for the change from expression backgrounds to microexpression. (3) The relevant brain areas of the GMERA and different types of microexpression recognition belonged to the three cognitive processes, but the relevant brain areas of the GMERA were the "higher-order" areas to be more concise and critical than those of different types of microexpression recognition.

16.
Healthcare (Basel) ; 10(8)2022 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-36011142

RESUMEN

Both tai chi and walking can improve the physical health of the elderly, but the effect on the emotional cognitive function of the elderly is unclear. To investigate the effect of long-term walking and tai chi exercise on the emotional cognitive function of the elderly, 63 subjects were recruited in this study according to age and exercise habits, including 16 in the youth control group, 15 in the elderly non-exercise control group, 17 in the elderly walking group, and 18 in the elderly tai chi group. The "learning-test paradigm" of emotional faces was used to measure the subjects' ability to recognize and remember emotional (negative and neutral) faces. Behavioral and EEG data were recorded during the learning and testing phases. The results showed that there is aging in emotional cognition in older adults compared with younger adults. Long-term walking and tai chi exercise can delay the deterioration of emotional cognitive function in older adults to some extent. Both walking and tai chi exercise can delay the decline in aging-related emotional face recognition function to some extent. Walking exercise can delay the decline in aging-related emotional face memory function to some extent.

17.
Opt Express ; 19(16): 15069-76, 2011 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-21934868

RESUMEN

Hard x-ray microscopy with nanometer resolution will open frontiers in the study of materials and devices, environmental sciences, and life sciences by utilizing the unique characterization capabilities of x-rays. Here we report two-dimensional nanofocusing by multilayer Laue lenses (MLLs), a type of diffractive optics that is in principle capable of focusing x-rays to 1 nm. We demonstrate focusing to a 25 × 27 nm(2) FWHM spot with an efficiency of 2% at a photon energy of 12 keV, and to a 25 × 40 nm(2) FWHM spot with an efficiency of 17% at a photon energy of 19.5 keV.


Asunto(s)
Microscopía/métodos , Nanotecnología/métodos , Animales , Diseño de Equipo , Humanos , Lentes , Microscopía Electrónica de Rastreo/métodos , Microscopía Fluorescente/métodos , Óptica y Fotónica/métodos , Fotones , Rayos X
18.
Adv Mater ; 33(21): e2008653, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33871108

RESUMEN

In the last decade, transmission X-ray microscopes (TXMs) have come into operation in most of the synchrotrons worldwide. They have proven to be outstanding tools for non-invasive ex and in situ 3D characterization of materials at the nanoscale across varying range of scientific applications. However, their spatial resolution has not improved in many years, while newly developed functional materials and microdevices with enhanced performances exhibit nanostructures always finer. Here, optomechanical breakthroughs leading to fast 3D tomographic acquisitions (85 min) with sub-10 nm spatial resolution, narrowing the gap between X-ray and electron microscopy, are reported. These new achievements are first validated with 3D characterizations of nanolithography objects corresponding to ultrahigh-aspect-ratio hard X-ray zone plates. Then, this powerful technique is used to investigate the morphology and conformality of nanometer-thick film electrodes synthesized by atomic layer deposition and magnetron sputtering deposition methods on 3D silicon scaffolds for electrochemical energy storage applications.

19.
Rev Sci Instrum ; 92(12): 123706, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34972426

RESUMEN

A hybrid deformable x-ray mirror consisting of a mechanical bender and a bimorph deformable mirror has been developed to realize adaptive optical systems, such as zoom condenser optics, for synchrotron-radiation-based x-ray microscopy. In the developed system, both bending mechanisms comprehensively contribute to the formation of the target mirror shape and can narrow the role of piezoelectric actuators, thereby enabling a more stable operation. In this study, the behavior of the bimorph mirror under the clamped condition was investigated, and the sharing of the deformation amount for each bending mechanism was optimized to minimize the amplitude of the voltage distribution of the bimorph mirror.

20.
Front Hum Neurosci ; 14: 281, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32848665

RESUMEN

The EMERT (ecological microexpression recognition test) by Zhang et al. (2017) used between-subjects Latin square block design for backgrounds; therefore, participants could not get comparable scores. The current study used within-subject pseudorandom design for backgrounds to improve EMERT to PREMERT (pseudorandom EMERT) and used eyes-closed and eyes-open resting-state functional magnetic resonance imaging to detect relevant brain activity of PREMERT for the first time. The results showed (1) two new recapitulative indexes of PREMERT were adopted, such as microexpression M and microexpression SD. Using pseudorandom design, the participants could effectively identify almost all the microexpressions, and each microexpression type had significant background effect. The PREMERT had good split-half reliability, parallel-forms reliability, criterion validity, and ecological validity. Therefore, it could stably and efficiently detect the participants' microexpression recognition abilities. Because of its pseudorandom design, all participants did the same test; their scores could be compared with each other. (2) amplitude of low-frequency fluctuations (ALFF; 0.01-0.1 Hz) in both eyes-closed and eyes-open resting states and ALFF difference could predict microexpression M, and the ALFF difference was less predictive. The relevant resting-state brain areas of microexpression M were some frontal lobes, insula, cingulate cortex, hippocampus, amygdala, fusiform gyrus, parietal lobe, caudate nucleus, precuneus, thalamus, putamen, temporal lobe, and cerebellum. (3) ALFFs in both eyes-closed and eyes-open resting states and ALFF difference could predict microexpression SD, and the ALFF difference was more predictive. The relevant resting-state brain areas of microexpression SD were some frontal lobes, central anterior gyrus, supplementary motor area, insula, hippocampus, amygdala, cuneus, occipital lobe, fusiform gyrus, parietal lobe, caudate nucleus, pallidum, putamen, thalamus, temporal lobe, and cerebellum. (4) There were many similar relevant resting-state brain areas, such as brain areas of expression recognition, microexpressions consciousness and attention, and the change from expression backgrounds to microexpression, and some different relevant resting-state brain areas, such as precuneus, insula, and pallidum, between microexpression M and SD. The ALFF difference was more sensitive to PREMERT fluctuations.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA