1.
J Cardiovasc Electrophysiol ; 25(8): 866-874, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24654678

RESUMEN

INTRODUCTION: Although the "near-zero-X-Ray" or "No-X-Ray" catheter ablation (CA) approach has been reported for treatment of various arrhythmias, few prospective studies have strictly used "No-X-Ray," simplified 2-catheter approaches for CA in patients with supraventricular tachycardia (SVT). We assessed the feasibility of a minimally invasive, nonfluoroscopic (MINI) CA approach in such patients. METHODS: Data were obtained from a prospective multicenter CA registry of patients with regular SVTs. After femoral access, 2 catheters were used to create simple, 3D electroanatomic maps and to perform electrophysiologic studies. Medical staff did not use lead aprons after the first 10 MINI CA cases. RESULTS: A total of 188 patients (age, 45 ± 21 years; 17% <19 years; 55% women) referred for the No-X-Ray approach were included. They were compared to 714 consecutive patients referred for a simplified approach using X-rays (age, 52 ± 18 years; 7% <19 years; 55% women). There were 9 protocol exceptions that necessitated the use of X-rays. Ultimately, 179/188 patients underwent the procedure without fluoroscopy, with an acute success rate of 98%. The procedure times (63 ± 26 vs. 63 ± 29 minutes, P > 0.05), major complications (0% vs. 0%, P > 0.05) and acute (98% vs. 98%, P > 0.05) and long-term (93% vs. 94%, P > 0.05) success rates were similar in the "No-X-Ray" and control groups. CONCLUSIONS: Implementation of a strict "No-X-Ray, simplified 2-catheter" CA approach is safe and effective in majority of the patients with SVT. This modified approach for SVTs should be prospectively validated in a multicenter study.


Asunto(s)
Ablación por Catéter/métodos , Taquicardia Supraventricular/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Niño , Preescolar , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Estudios de Factibilidad , Femenino , Fluoroscopía , Humanos , Plomo , Masculino , Persona de Mediana Edad , Tempo Operativo , Polonia , Valor Predictivo de las Pruebas , Estudios Prospectivos , Ropa de Protección , Dosis de Radiación , Protección Radiológica/instrumentación , Sistema de Registros , Taquicardia Supraventricular/diagnóstico por imagen , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
2.
Medicine (Baltimore) ; 96(25): e6939, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28640075

RESUMEN

Radiofrequency catheter ablation (RFCA) is an established effective method for the treatment of typical cavo-tricuspid isthmus (CTI)-dependent atrial flutter (AFL). The introduction of 3-dimensional electro-anatomic systems enables RFCA without fluoroscopy (No-X-Ray [NXR]). The aim of this study was to evaluate the feasibility and effectiveness of CTI RFCA during implementation of the NXR approach and the maximum voltage-guided (MVG) technique for ablation of AFL.Data were obtained from prospective standardized multicenter ablation registry. Consecutive patients with the first RFCA for CTI-dependent AFL were recruited. Two navigation approaches (NXR and fluoroscopy based as low as reasonable achievable [ALARA]) and 2 mapping and ablation techniques (MVG and pull-back technique [PBT]) were assessed. NXR + MVG (n  =  164; age: 63.7 ±â€Š9.5; 30% women), NXR + PBT (n  =  55; age: 63.9 ±â€Š10.7; 39% women); ALARA + MVG (n  =  36; age: 64.2 ±â€Š9.6; 39% women); and ALARA + PBT (n  =  205; age: 64.7 ±â€Š9.1; 30% women) were compared, respectively. All groups were simplified with a 2-catheter femoral approach using 8-mm gold tip catheters (Osypka AG, Germany or Biotronik, Germany) with 15 min of observation. The MVG technique was performed using step-by-step application by mapping the largest atrial signals within the CTI.Bidirectional block in CTI was achieved in 99% of all patients (P  =  NS, between groups). In NXR + MVG and NXR + PBT groups, the procedure time decreased (45.4 ±â€Š17.6 and 47.2 ±â€Š15.7 min vs. 52.6 ±â€Š23.7 and 59.8 ±â€Š24.0 min, P < .01) as compared to ALARA + MVG and ALARA + PBT subgroups. In NXR + MVG and NXR + PBT groups, 91% and 98% of the procedures were performed with complete elimination of fluoroscopy. The NXR approach was associated with a significant reduction in fluoroscopy exposure (from 0.2 ±â€Š1.1 [NXR + PBT] and 0.3 ±â€Š1.6 [NXR + MVG] to 7.7 ±â€Š6.0 min [ALARA + MVG] and 9.1 ±â€Š7.2 min [ALARA + PBT], P < .001). The total application time significantly decreased in the MVG technique subgroup both in NXR and ALARA (P < .01). No major complications were observed in either groups.Complete elimination of fluoroscopy is feasible, safe, and effective during RFCA of CTI in almost all AFL patients without cardiac implanted electronic devices. The most optimal method for RFCA of CTI-dependent AFL seems to be MVG; however, it required validation of optimal RFCA's parameters with clinical follow-up.


Asunto(s)
Aleteo Atrial/cirugía , Ablación por Catéter , Adulto , Anciano , Anciano de 80 o más Años , Ablación por Catéter/métodos , Estudios de Factibilidad , Femenino , Fluoroscopía , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Mejoramiento de la Calidad , Sistema de Registros , Resultado del Tratamiento