Clin Chem ; 56(10): 1554-60, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20702784

RESUMEN

BACKGROUND: Bar code technology has decreased transcription errors in many healthcare applications. However, we have found that linear bar code identification methods are not failsafe. In this study, we sought to identify the sources of bar code decoding errors that generated incorrect patient identifiers when bar codes were scanned for point-of-care glucose testing and to develop solutions to prevent their occurrence. METHODS: We identified misread wristband bar codes, removed them from service, and rescanned them by using 5 different scanner models. Bar codes were reprinted in pristine condition for use as controls. We determined error rates for each bar code-scanner pair and manually calculated internal bar code data integrity checks. RESULTS: As many as 3 incorrect patient identifiers were generated from a single bar code. Minor bar code imperfections, failure to control for bar code scanner resolution requirements, and less than optimal printed bar code orientation were confirmed as sources of these errors. Of the scanner models tested, the Roche ACCU-CHEK® glucometer had the highest error rate. The internal data integrity check system did not detect these errors. CONCLUSIONS: Bar code-related patient misidentifications can occur. In the worst case, misidentified patient results could have been transmitted to the incorrect patient medical record. This report has profound implications not only for point-of-care testing but also for bar coded medication administration, transfusion recipient certification systems, and other areas where patient misidentifications can be life-threatening. Careful control of bar code scanning and printing equipment specifications will minimize this threat to patient safety. Ultimately, healthcare device manufacturers should adopt more robust and higher fidelity alternatives to linear bar code symbologies.


Asunto(s)
Procesamiento Automatizado de Datos , Falla de Equipo , Sistemas de Identificación de Pacientes/métodos , Humanos
5.
Pain Physician ; 20(2S): SE1-SE9, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-28226337

RESUMEN

BACKGROUND: Enzyme immunoassays (EIA) have notable limitations for monitoring therapeutic compliance in pain management. Chromatography coupled with mass spectrometry provides definitive results and superior sensitivity and specificity over traditional EIA testing. OBJECTIVE: To analyze and compare the sensitivity of EIA results together with known prescriptions to liquid chromatography-tandem mass spectrometry (LC-MS/MS) for monitoring drug use (and abuse) in patients treated for chronic pain. STUDY DESIGN: A total of 530 urine samples from patients being treated for chronic pain were studied. SETTING: Pain management clinic in the United States. METHODS: The samples were tested for a profile of chronic pain medications and illicit drugs with commercially available EIA kits followed by analysis with Agilent LC-MS/MS system. RESULTS: The EIAs exhibited poor sensitivity and high rates of false negative results in the pain management setting. For example, 21% of EIA for opiates show false negative results. Mass spectrometry methods were more sensitive, detected a broader range of drugs and metabolites, and could detect non-prescribed drug use and simulations in compliance. LIMITATIONS: Patients do not always accurately report drug use information, and some drugs do not have EIA methods available for comparative purposes. CONCLUSIONS: Mass spectrometry is a more robust and reliable method for detection of drugs used in the pain management setting. Due to the extent of undisclosed use and abuse of medications and illicit drugs, LC-MS/MS testing is necessary for adequate and accurate drug detection. In addition, LC-MS/MS methods are superior in terms of sensitivity and number of compounds that can be screened, making this a better method for use in pain management. Key words: Pain management, enzyme immunoassays, mass spectrometry, urine drug testing, prescription status, compliance.


Asunto(s)
Dolor Crónico/tratamiento farmacológico , Inmunoensayo/métodos , Cromatografía Liquida , Humanos , Cumplimiento de la Medicación , Sensibilidad y Especificidad , Detección de Abuso de Sustancias , Espectrometría de Masas en Tándem
6.
Pain Physician ; 17(4): 359-66, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25054395

RESUMEN

BACKGROUND: Patients treated for chronic pain may frequently undergo urine drug testing to monitor medication compliance and detect undisclosed prescribed or illicit drug use. Due to the increasing use and abuse of benzodiazepines, this class of medications is often included in drug screening panels. However, immunoassay-based methods lack the requisite sensitivity for detecting benzodiazepine use in this population primarily due to their poor cross-reactivity with several major urinary benzodiazepine metabolites. A High Sensitivity Cloned Enzyme Donor Immunoassay (HS-CEDIA), in which beta-glucuronidase is added to the reagent, has been shown to perform better than traditional assays, but its performance in patients treated for chronic pain is not well characterized. OBJECTIVES: To determine the diagnostic accuracy of HS-CEDIA, as compared to the Cloned Enzyme Donor Immunoassay (CEDIA) and Kinetic Interaction of Microparticles in Solution (KIMS) screening immunoassays and liquid chromatography-tandem mass spectrometry (LC-MS/MS), for monitoring benzodiazepine use in patients treated for chronic pain. STUDY DESIGN: A study of the diagnostic accuracy of urine benzodiazepine immunoassays. SETTING: The study was conducted at an academic tertiary care hospital with a clinical laboratory that performs urine drug testing for monitoring medication compliance in pain management. METHODS: A total of 299 urine specimens from patients treated for chronic pain were screened for the presence of benzodiazepines using the HS-CEDIA, CEDIA, and KIMS assays. The sensitivity and specificity of the screening assays were determined using the LC-MS/MS results as the reference method. RESULTS: Of the 299 urine specimens tested, 141 (47%) confirmed positive for one or more of the benzodiazepines/metabolites by LC-MS/MS. All 3 screens were 100% specific with no false-positive results. The CEDIA and KIMS sensitivities were 55% (78/141) and 47% (66/141), respectively. Despite the relatively higher sensitivity of the HS-CEDIA screening assay (78%; 110/141), primarily due to increased detection of lorazepam, it still missed 22% (31/141) of benzodiazepine-positive urines. The KIMS, CEDIA, and HS-CEDIA assays yielded accuracies of 75%, 79%, and 90%, respectively, in comparison with LC-MS/MS. LIMITATIONS: This study was limited by its single-site location and the modest size of the urine samples utilized. CONCLUSIONS: While the HS-CEDIA provides higher sensitivity than the KIMS and CEDIA assays, it still missed an unacceptably high percentage of benzodiazepine-positive samples from patients treated for chronic pain. LC-MS/MS quantification with enzymatic sample pretreatment offers superior sensitivity and specificity for monitoring benzodiazepines in patients treated for chronic pain.


Asunto(s)
Benzodiazepinas/orina , Dolor Crónico/orina , Monitoreo de Drogas , Inmunoensayo , Humanos , Sensibilidad y Especificidad , Urinálisis/normas
7.
J Anal Toxicol ; 38(6): 375-9, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24802159

RESUMEN

Buprenorphine (BUP), a semi-synthetic opioid analgesic, is increasingly prescribed for the treatment of chronic pain and opioid dependence. Urine immunoassay screening methods are available for monitoring BUP compliance and misuse; however, these screens may have poor sensitivity or specificity. We evaluated whether the pretreatment of urine with ß-glucuronidase (BG) improves the sensitivity and overall accuracy of three BUP enzyme immunoassays when compared with liquid chromatography-tandem mass spectrometry (LC-MS-MS). Urine samples sent to our laboratories for BUP testing (n = 114) were analyzed before and after BG pretreatment by cloned enzyme donor immunoassay (CEDIA), enzyme immunoassay (EIA) and homogenous EIA (HEIA) immunoassays using a common 5 ng/mL cutoff. Total BUP and norbuprenorphine (NBUP) concentrations were measured by LC-MS-MS as the reference method. Urine BG pretreatment improved EIA, HEIA and CEDIA sensitivities from 70, 82 and 94%, respectively, to 97% for each of the three methods, when compared with LC-MS-MS. While the specificity of the EIA and HEIA remained 100% after BG pretreatment, the specificity of the CEDIA decreased from 74 to 67%. Urine pretreatment with BG is recommended to improve sensitivity of the EIA and HEIA BUP screening methods.


Asunto(s)
Analgésicos Opioides/orina , Buprenorfina/orina , Monitoreo de Drogas/métodos , Glucuronidasa/química , Inmunoensayo/métodos , Analgésicos Opioides/química , Buprenorfina/química , Cromatografía Liquida , Dolor Crónico/orina , Humanos , Trastornos Relacionados con Opioides/orina , Sensibilidad y Especificidad , Espectrometría de Masas en Tándem , Orina/química
10.
Clin Chim Acta ; 422: 10-4, 2013 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-23545276

RESUMEN

INTRODUCTION: Reference laboratory testing can represent a significant component of the laboratory budget. Therefore, most laboratories continually reassess the feasibility of in-sourcing various tests. We describe the transfer of urine drug testing performed for monitoring medication compliance in pain management from a reference laboratory into an academic clinical laboratory. METHODS: The process of implementing of both screening immunoassays and confirmatory LC-MS/MS testing and the associated cost savings is outlined. RESULTS: The initial proposal for in-sourcing this testing, which included the tests to be in-sourced, resources required, estimated cost savings and timeline for implementation, was approved in January 2009. All proposed testing was implemented by March 2011. CONCLUSIONS: Keys to the successful implementation included budgeting adequate resources and developing a realistic timeline, incorporating the changes with the highest budget impact first. We were able to in-source testing in 27 months and save the laboratory approximately $1 million in the first 3 year.


Asunto(s)
Ahorro de Costo , Monitoreo de Drogas/economía , Cumplimiento de la Medicación , Manejo del Dolor/economía , Urinálisis/economía , Buprenorfina/orina , Cromatografía Liquida , Fentanilo/orina , Humanos , Cumplimiento de la Medicación/estadística & datos numéricos , Derivados de la Morfina/orina , Espectrometría de Masas en Tándem , Tramadol/orina
11.
J Anal Toxicol ; 36(3): 201-6, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22417836

RESUMEN

Urine buprenorphine screening is utilized to assess buprenorphine compliance and to detect illicit use. Robust screening assays should be specific for buprenorphine without cross-reactivity with other opioids, which are frequently present in patients treated for opioid addiction and chronic pain. We evaluated the new Lin-Zhi urine buprenorphine enzyme immunoassay (EIA) as a potentially more specific alternative to the Microgenics cloned enzyme donor immunoassay (CEDIA) by using 149 urines originating from patients treated for chronic pain and opioid addiction. The EIA methodology offered specific detection of buprenorphine use (100%) (106/106) and provided superior overall agreement with liquid chromatography-tandem mass spectrometry, 95% (142/149) and 91% (135/149) using 5 ng/mL (EIA[5]) and 10 ng/mL (EIA[10]) cutoffs, respectively, compared to CEDIA, 79% (117/149). CEDIA generated 27 false positives, most of which were observed in patients positive for other opioids, providing an overall specificity of 75% (79/106). CEDIA also demonstrated interference from structurally unrelated drugs, chloroquine and hydroxychloroquine. CEDIA and EIA[5] yielded similar sensitivities, both detecting 96% (22/23) of positive samples from patients prescribed buprenorphine, and 88% (38/43) and 81% (35/43), respectively, of all positive samples (illicit and prescribed users). The EIA methodology provides highly specific and sensitive detection of buprenorphine use, without the potential for opioid cross-reactivity.


Asunto(s)
Buprenorfina/orina , Narcóticos/orina , Detección de Abuso de Sustancias/métodos , Trastornos Relacionados con Sustancias/diagnóstico , Buprenorfina/inmunología , Buprenorfina/uso terapéutico , Cromatografía Líquida de Alta Presión , Dolor Crónico/tratamiento farmacológico , Toxicología Forense/métodos , Humanos , Técnicas para Inmunoenzimas/métodos , Narcóticos/inmunología , Narcóticos/uso terapéutico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Trastornos Relacionados con Sustancias/orina , Espectrometría de Masas en Tándem
12.
J Chromatogr B Analyt Technol Biomed Life Sci ; 893-894: 168-72, 2012 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-22425273

RESUMEN

An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the direct measurement of argatroban in human plasma was developed and compared with the activity-based Hemoclot Thrombin Inhibitors assay. UPLC-MS/MS was performed using diclofenac as an internal standard. In summary, argatroban and diclofenac were extracted from 100 µL of plasma using a methanol precipitation protocol, and chromatographic separation was performed on an ACQUITY TQD mass spectrometer using a UPLC C18 BEH 1.7 µm column with a water and methanol gradient containing 0.1% formic acid. The detection and quantitation were performed using positive ion electrospray ionization and multiple reaction monitoring (MRM) mode. The UPLC-MS/MS method was linear over the concentration range of 0.003-3.0 µg/mL, with a lower limit of quantitation for argatroban of 0.003 µg/mL. The intra- and inter-assay imprecision was less than 12% at the plasma argatroban concentrations tested. Good correlation was demonstrated between the UPLC-MS/MS method and the indirect activity-based assay for determination of argatroban. However, increased plasma fibrinogen levels caused underestimation of argatroban levels using the indirect activity-based assay, whereas the UPLC-MS/MS method was unaffected. UPLC-MS/MS provides a relatively simple, sensitive, and rapid means of argatroban monitoring. It has successfully been applied to assess plasma argatroban concentrations in hospitalized patients and may provide a more accurate determination of argatroban concentrations than an activity-based assay in certain clinical conditions.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Monitoreo de Drogas/métodos , Ácidos Pipecólicos/sangre , Espectrometría de Masas en Tándem/métodos , Arginina/análogos & derivados , Humanos , Modelos Lineales , Reproducibilidad de los Resultados , Sulfonamidas
13.
Clin Chim Acta ; 412(11-12): 946-51, 2011 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-21281622

RESUMEN

BACKGROUND: Opiate and other drugs of abuse screening assays have been available for many years, and successfully utilized for monitoring patient medication compliance and for detecting misuse. However, immunoassays designed to rapidly detect the highly potent synthetic opioid, fentanyl, have not been available. METHODS: We evaluated a new fentanyl homogeneous enzyme immunoassay (HEIA) (Immunalysis Corporation) for its ability to accurately detect fentanyl in 307 urine samples from patients prescribed chronic opioid therapy. Samples were screened by HEIA and confirmed by LC-MS/MS and ELISA for diagnostic comparison. HEIA precision and interference studies were performed. RESULTS: HEIA diagnostic sensitivity, specificity and accuracy were 97%, 99%, and 99%, respectively, in comparison with LC-MS/MS and ELISA. HEIA detected 37 of the 38 LC-MS/MS positive samples identified in our initial evaluation, including some that contained very low levels of fentanyl, <1 ng/ml (<3 fmol/l). HEIA showed minimal cross-reactivity with other opioid analgesics and commonly encountered drugs. Interferences by common urine contaminants were negligible, but we observed considerable signal suppression in acidic samples (pH<4.0). CONCLUSIONS: The HEIA urine fentanyl assay allows for rapid and accurate fentanyl detection, illustrating its utility in monitoring fentanyl compliance and abuse.


Asunto(s)
Fentanilo/orina , Técnicas para Inmunoenzimas/métodos , Cumplimiento de la Medicación/estadística & datos numéricos , Urinálisis/métodos , Analgésicos Opioides/uso terapéutico , Analgésicos Opioides/orina , Automatización , Dolor Crónico/tratamiento farmacológico , Dolor Crónico/orina , Prescripciones de Medicamentos , Fentanilo/uso terapéutico , Humanos
14.
Methods Mol Biol ; 603: 129-36, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20077065

RESUMEN

Busulfan is a chemotherapy drug widely used as part of conditioning regimens for patients undergoing bone marrow transplantation (BMT). Challenges of busulfan treatment include a narrow therapeutic window and wide inter- and intra-patient variability. Inappropriately low drug levels lead to relapse and even graft rejection, while higher doses frequently have toxic and sometimes fatal consequences. Maintenance of plasma busulfan concentrations using repeated measurements and proper adjustment of dosage can reduce busulfan-related toxicity and improve treatment outcomes. We describe a rapid (2-minute total analysis time per sample) and simple method for accurate and precise busulfan concentration determination in plasma samples (100 microL) using high performance liquid chromatography combined with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Busulfan is isolated from plasma after internal standard (busulfan-D(8))-methanol extraction, dilution with mobile phase (ammonium acetate-formic acid-water), and centrifugation. The supernatant plasma is injected onto the HPLC-ESI-MS/MS and quantified using a six-point standard curve. The assay is linear from 0.025 microg/mL (approximately 0.1 micromol/L) to at least 6.2 microg/mL (approximately 25 micromol/L) with precisions of <5% over the entire range.


Asunto(s)
Busulfano/sangre , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masas en Tándem/métodos , Humanos , Reproducibilidad de los Resultados