Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38375690

RESUMEN

AIMS: Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) detects myocardial scarring, a risk factor for ventricular arrhythmias (VAs) in hypertrophic cardiomyopathy (HCM). The LGE-CMR distinguishes core, borderzone (BZ) fibrosis, and BZ channels, crucial components of re-entry circuits. We studied how scar architecture affects inducibility and electrophysiological traits of VA in HCM. METHODS AND RESULTS: We correlated scar composition with programmed ventricular stimulation-inducible VA features using LGE intensity maps. Thirty consecutive patients were enrolled. Thirteen (43%) were non-inducible, 6 (20%) had inducible non-sustained, and 11 (37%) had inducible sustained mono (MMVT)- or polymorphic VT/VF (PVT/VF). Of 17 induced VA, 13 (76%) were MMVT that either ended spontaneously, persisted as sustained monomorphic, or degenerated into PVT/VF. Twenty-seven patients (90%) had LGE. Of these, 17 (57%) had non-sustained or sustained inducible VA. Scar mass significantly increased (P = 0.002) from non-inducible to inducible non-sustained and sustained VA patients in both the BZ and core components. Borderzone channels were found in 23%, 67%, and 91% of non-inducible, inducible non-sustained, and inducible sustained VA patients (P = 0.003). All 13 patients induced with MMVT or monomorphic-initiated PVT/VF had LGE. The origin of 10/13 of these VTs matched scar location, with 8/10 of these LGE regions showing BZ channels. During follow-up (20 months, interquartile range: 7-37), one patient with BZ channels and inducible PVT had an ICD shock for VF. CONCLUSION: Scar architecture determines inducibility and electrophysiological traits of VA in HCM. Larger studies should explore the role of complex LGE patterns in refining risk assessment in HCM patients.


Asunto(s)
Cardiomiopatía Hipertrófica , Canal de Sodio Activado por Voltaje NAV1.5/deficiencia , Taquicardia Ventricular , Fibrilación Ventricular , Humanos , Cicatriz/complicaciones , Cicatriz/patología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Medios de Contraste , Gadolinio/farmacología , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Arritmias Cardíacas/etiología , Arritmias Cardíacas/complicaciones
2.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38652090

RESUMEN

AIMS: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using very high-power short-duration (vHPSD) radiofrequency (RF) ablation proved to be safe and effective. However, vHPSD applications result in shallower lesions that might not be always transmural. Multidetector computed tomography-derived left atrial wall thickness (LAWT) maps could enable a thickness-guided switching from vHPSD to the standard-power ablation mode. The aim of this randomized trial was to compare the safety, the efficacy, and the efficiency of a LAWT-guided vHPSD PVI approach with those of the CLOSE protocol for PAF ablation (NCT04298177). METHODS AND RESULTS: Consecutive patients referred for first-time PAF ablation were randomized on a 1:1 basis. In the QDOT-by-LAWT arm, for LAWT ≤2.5 mm, vHPSD ablation was performed; for points with LAWT > 2.5 mm, standard-power RF ablation titrating ablation index (AI) according to the local LAWT was performed. In the CLOSE arm, LAWT information was not available to the operator; ablation was performed according to the CLOSE study settings: AI ≥400 at the posterior wall and ≥550 at the anterior wall. A total of 162 patients were included. In the QDOT-by-LAWT group, a significant reduction in procedure time (40 vs. 70 min; P < 0.001) and RF time (6.6 vs. 25.7 min; P < 0.001) was observed. No difference was observed between the groups regarding complication rate (P = 0.99) and first-pass isolation (P = 0.99). At 12-month follow-up, no significant differences occurred in atrial arrhythmia-free survival between groups (P = 0.88). CONCLUSION: LAWT-guided PVI combining vHPSD and standard-power ablation is not inferior to the CLOSE protocol in terms of 1-year atrial arrhythmia-free survival and demonstrated a reduction in procedural and RF times.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Atrios Cardíacos , Tomografía Computarizada Multidetector , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Venas Pulmonares/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Femenino , Masculino , Ablación por Catéter/métodos , Persona de Mediana Edad , Anciano , Atrios Cardíacos/cirugía , Atrios Cardíacos/diagnóstico por imagen , Factores de Tiempo , Resultado del Tratamiento , Recurrencia , Frecuencia Cardíaca , Potenciales de Acción
3.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37961921

RESUMEN

AIMS: The aim of our study was to analyse the response to short-coupled atrial extrastimuli to identify areas of hidden slow conduction (HSC) and their relationship with the atrial fibrillation (AF) phenotype. METHODS AND RESULTS: Twenty consecutive patients with paroxysmal AF and persistent AF (10:10) underwent the first pulmonary vein isolation procedure. Triple short-coupled extrastimuli were delivered in sinus rhythm (SR), and the evoked response was analysed: sites exhibiting double or highly fragmented electrograms (EGM) were defined as positive for HSC (HSC+). The delta of the duration of the bipolar EGM was analysed, and bipolar EGM duration maps were built. High-density maps were acquired using a multipolar catheter during AF, SR, and paced rhythm. Spatial co-localization of HSC+ and complex fractionated atrial EGMs (CFAE) during AF was evaluated. Persistent AF showed a higher number and percentage of HSC+ than paroxysmal AF (13.9% vs. 3.3%, P < 0.001). The delta of EGM duration was 53 ± 22 ms for HSC+ compared with 13 ± 11 (10) ms in sites with negative HSC (HSC-) (P < 0.001). The number and density of HSC+ were lower than CFAE during AF (19 vs. 56 per map, P < 0.001). The reproducibility and distribution of HSC+ in repeated maps were superior to CFAE (P = 0.19 vs. P < 0.001). Sites with negative and positive responses showed a similar bipolar voltage in the preceding sinus beat (1.65 ± 1.34 and 1.48 ± 1.47 mV, P = 0.12). CONCLUSION: Functional mapping identifies more discrete and reproducible abnormal substrates than mapping during AF. The HSC+ sites in response to triple extrastimuli are more frequent in persistent AF than in paroxysmal AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Reproducibilidad de los Resultados , Técnicas Electrofisiológicas Cardíacas/métodos , Frecuencia Cardíaca , Atrios Cardíacos
4.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38011712

RESUMEN

AIMS: Epicardial adipose tissue might promote atrial fibrillation (AF) in several ways, including infiltrating the underlying atrial myocardium. However, the role of this potential mechanism has been poorly investigated. The aim of this study is to evaluate the presence of left atrial (LA) infiltrated adipose tissue (inFAT) by analysing multi-detector computer tomography (MDCT)-derived three-dimensional (3D) fat infiltration maps and to compare the extent of LA inFAT between patients without AF history, with paroxysmal, and with persistent AF. METHODS AND RESULTS: Sixty consecutive patients with AF diagnosis (30 persistent and 30 paroxysmal) were enrolled and compared with 20 age-matched control; MDCT-derived images were post-processed to obtain 3D LA inFAT maps for all patients. Volume (mL) and mean signal intensities [(Hounsfield Units (HU)] of inFAT (HU -194; -5), dense inFAT (HU -194; -50), and fat-myocardial admixture (HU -50; -5) were automatically computed by the software. inFAT volume was significantly different across the three groups (P = 0.009), with post-hoc pairwise comparisons showing a significant increase in inFAT volume in persistent AF compared to controls (P = 0.006). Dense inFAT retained a significant difference also after correcting for body mass index (P = 0.028). In addition, more negative inFAT radiodensity values were found in AF patients. Regional distribution analysis showed a significantly higher regional distribution of LA inFAT at left and right superior pulmonary vein antra in AF patients. CONCLUSION: Persistent forms of AF are associated with greater degree of LA intramyocardial adipose infiltration, independently of body mass index. Compared to controls, AF patients present higher LA inFAT volume at left and right superior pulmonary vein antra.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Atrios Cardíacos/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Angiografía , Ablación por Catéter/métodos
5.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37125968

RESUMEN

AIMS: Pulmonary vein (PV) antrum isolation proved to be effective for treating persistent atrial fibrillation (PeAF). We sought to investigate the results of a personalized approach aimed at adapting the ablation index (AI) to the local left atrial wall thickness (LAWT) in a cohort of consecutive patients with PeAF. METHODS AND RESULTS: Consecutive patients referred for PeAF first ablation were prospectively enrolled. The LAWT three-dimensional maps were obtained from pre-procedure multidetector computed tomography and integrated into the navigation system. Ablation index was titrated according to the local LAWT, and the ablation line was personalized to avoid the thickest regions while encircling the PV antrum. A total of 121 patients (69.4% male, age 64.5 ± 9.5 years) were included. Procedure time was 57 min (IQR 50-67), fluoroscopy time was 43 s (IQR 20-71), and radiofrequency (RF) time was 16.5 min (IQR 14.3-18.4). The median AI tailored to the local LAWT was 387 (IQR 360-410) for the anterior wall and 335 (IQR 300-375) for the posterior wall. First-pass PV antrum isolation was obtained in 103 (85%) of the right PVs and 103 (85%) of the left PVs. Median LAWT values were higher for PVs without first-pass isolation as compared to the whole cohort (P = 0.02 for left PVs and P = 0.03 for right PVs). Recurrence-free survival was 79% at 12 month follow-up. CONCLUSION: In this prospective study, LAWT-guided PV antrum isolation for PeAF was effective and efficient, requiring low procedure, fluoroscopy, and RF time. A randomized trial comparing the LAWT-guided ablation with the standard of practice is in progress (ClinicalTrials.gov, NCT05396534).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Estudios Prospectivos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Resultado del Tratamiento
6.
Europace ; 24(6): 938-947, 2022 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-34849726

RESUMEN

AIMS: To non-invasively characterize, by means of late gadolinium enhancement cardiac magnetic resonance (LGE-CMR), scar differences, and potential variables associated with ventricular tachycardia (VT) occurrence in chronic post-myocardial infarction (MI) patients. METHODS AND RESULTS: A case-control study was designed through retrospective LGE-CMR data analysis of chronic post-MI patients (i) consecutively referred for VT substrate ablation after a first VT episode (n = 66) and (ii) from a control group (n = 84) with no arrhythmia evidence. The myocardium was characterized differentiating core, border zone (BZ), and BZ channels (BZCs) using the ADAS 3D post-processing imaging platform. Clinical and scar characteristics, including a novel parameter, the BZC mass, were compared between both groups. One hundred and fifty post-MI patients were included. Four multivariable Cox proportional hazards regression models were created for total scar mass, BZ mass, core mass, and BZC mass, adjusting them by age, sex, and left ventricular ejection fraction (LVEF). A cut-off of 5.15 g of BZC mass identified the cases with 92.4% sensitivity and 86.9% specificity [area under the ROC curve (AUC) 0.93 (0.89-0.97); P < 0.001], with a significant increase in the AUC compared to other scar parameters (P < 0.001 for all pairwise comparisons). Adding BZC mass to LVEF allowed to reclassify 33.3% of the cases and 39.3% of the controls [net reclassification improvement = 0.73 (0.71-0.74)]. CONCLUSIONS: The mass of BZC is the strongest independent variable associated with the occurrence of sustained monomorphic ventricular tachycardia in post-MI patients after adjustment for age, sex, and LVEF. Border zone channel mass measurement could permit a more accurate VT risk stratification than LVEF in chronic post-MI patients.


Asunto(s)
Infarto del Miocardio , Taquicardia Ventricular , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/etiología , Estudios de Casos y Controles , Cicatriz , Medios de Contraste , Gadolinio , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/patología , Estudios Retrospectivos , Volumen Sistólico , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/etiología , Función Ventricular Izquierda
7.
Europace ; 24(3): 390-399, 2022 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-34480548

RESUMEN

AIMS: To determine if adapting the ablation index (AI) to the left atrial wall thickness (LAWT), which is a determinant of lesion transmurality, is feasible, effective, and safe during paroxysmal atrial fibrillation (PAF) ablation. METHODS AND RESULTS: Consecutive patients referred for PAF first ablation. Left atrial wall thickness three-dimensional maps were obtained from multidetector computed tomography and integrated into the CARTO navigation system. Left atrial wall thickness was categorized into 1 mm layers and AI was titrated to the LAWT. The ablation line was personalized to avoid thicker regions. Primary endpoints were acute efficacy and safety, and freedom from atrial fibrillation (AF) recurrences. Follow-up (FU) was scheduled at 1, 3, 6, and every 6 months thereafter. Ninety patients [60 (67%) male, age 58 ± 13 years] were included. Mean LAWT was 1.25 ± 0.62 mm. Mean AI was 366 ± 26 on the right pulmonary veins with a first-pass isolation in 84 (93%) patients and 380 ± 42 on the left pulmonary veins with first-pass in 87 (97%). Procedure time was 59 min (49-66); radiofrequency (RF) time 14 min (12.5-16); and fluoroscopy time 0.7 min (0.5-1.4). No major complication occurred. Eighty-four out of 90 (93.3%) patients were free of recurrence after a mean FU of 16 ± 4 months. CONCLUSION: Personalized AF ablation, adapting the AI to LAWT allowed pulmonary vein isolation with low RF delivery, fluoroscopy, and procedure time while obtaining a high rate of first-pass isolation, in this patient population. Freedom from AF recurrences was as high as in more demanding ablation protocols. A multicentre trial is ongoing to evaluate reproducibility of these results.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Reproducibilidad de los Resultados , Resultado del Tratamiento
8.
J Electrocardiol ; 70: 4-6, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34801837

RESUMEN

A 38-year-old woman with a structurally normal heart was referred for catheter ablation due to symptomatic, monomorphic, high burden (12%) premature ventricular complexes (PVC) refractory to medical therapy. The PVC's ECG morphology suggested an origin in the proximal left anterior fascicle (LAF). During procedure PVCs were mechanically suppressed. Consequently, selection of the ablation target site was based on pace-mapping. This case illustrates how ablation from the right coronary cusp (RCC) for PVC arising from the proximal LAF could be accurately guided by pace-mapping. At this location, pacing can result in both a selective and a non-selective capture of the proximal LAF.


Asunto(s)
Mapeo del Potencial de Superficie Corporal , Fascículo Atrioventricular , Ablación por Catéter , Complejos Prematuros Ventriculares , Adulto , Válvula Aórtica/cirugía , Fascículo Atrioventricular/fisiopatología , Fascículo Atrioventricular/cirugía , Ablación por Catéter/métodos , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía
9.
Europace ; 23(8): 1285-1294, 2021 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-33846728

RESUMEN

AIMS: To assess potential benefits of a local activation time (LAT) automatic acquisition protocol using wavefront annotation plus an ECG pattern matching algorithm [automatic (AUT)-arm] during premature ventricular complex (PVC) ablation procedures. METHODS AND RESULTS: Prospective, randomized, controlled, and international multicentre study (NCT03340922). One hundred consecutive patients with indication for PVC ablation were enrolled and randomized to AUT (n = 50) or manual (MAN, n = 50) annotation protocols using the CARTO3 navigation system. The primary endpoint was mapping success. Clinical success was defined as a PVC-burden reduction of ≥80% in the 24-h Holter within 6 months after the procedure. Mean age was 56 ± 14 years, 54% men. The mean baseline PVC burden was 25 ± 13%, and mean left ventricular ejection fraction (LVEF) 55 ± 11%. Baseline characteristics were similar between the groups. The most frequent PVC-site of origin were right ventricular outflow tract (41%), LV (25%), and left ventricular outflow tract (17%), without differences between groups. Radiofrequency (RF) time and number of RF applications were similar for both groups. Mapping and procedure times were significantly shorter in the AUT-arm (25.5 ± 14.3 vs. 32.8 ± 12.6 min, P = 0.009; and 54.8 ± 24.8 vs. 67.4 ± 25.2, P = 0.014, respectively), while more mapping points were acquired [136 (94-222) AUT vs. 79 (52-111) MAN; P < 0.001]. Mapping and clinical success were similar in both groups. There were no procedure-related complications. CONCLUSION: The use of a complete automatic protocol for LAT annotation during PVC ablation procedures allows to achieve similar clinical endpoints with higher procedural efficiency when compared with conventional, manual annotation carried out by expert operators.


Asunto(s)
Ablación por Catéter , Complejos Prematuros Ventriculares , Adulto , Anciano , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía
10.
Europace ; 23(3): 380-388, 2021 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-33227129

RESUMEN

AIMS: Myocardial fibrosis is a hallmark of atrial fibrillation (AF) and its characterization could be used to guide ablation procedures. Late gadolinium enhanced-magnetic resonance imaging (LGE-MRI) detects areas of atrial fibrosis. However, its accuracy remains controversial. We aimed to analyse the accuracy of LGE-MRI to identify left atrial (LA) arrhythmogenic substrate by analysing voltage and conduction velocity at the areas of LGE. METHODS AND RESULTS: Late gadolinium enhanced-magnetic resonance imaging was performed before ablation in 16 patients. Atrial wall intensity was normalized to blood pool and classified as healthy, interstitial fibrosis, and dense scar tissue depending of the resulting image intensity ratio. Bipolar voltage and local conduction velocity were measured in LA with high-density electroanatomic maps recorded in sinus rhythm and subsequently projected into the LGE-MRI. A semi-automatic, point-by-point correlation was made between LGE-MRI and electroanatomical mapping. Mean bipolar voltage and local velocity progressively decreased from healthy to interstitial fibrosis to scar. There was a significant negative correlation between LGE with voltage (r = -0.39, P < 0.001) and conduction velocity (r = -0.25, P < 0.001). In patients showing dilated atria (LA diameter ≥45 mm) the conduction velocity predictive capacity of LGE-MRI was weaker (r = -0.40 ± 0.09 vs. -0.20 ± 0.13, P = 0.02). CONCLUSIONS: Areas with higher LGE show lower voltage and slower conduction in sinus rhythm. The enhancement intensity correlates with bipolar voltage and conduction velocity in a point-by-point analysis. The performance of LGE-MRI in assessing local velocity might be reduced in patients with dilated atria (LA diameter ≥45).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/cirugía , Medios de Contraste , Fibrosis , Gadolinio , Atrios Cardíacos/cirugía , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética
11.
Europace ; 23(1): 82-90, 2021 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-33038230

RESUMEN

AIMS: Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) permits characterizing ischaemic scars, detecting heterogeneous tissue channels (HTCs) which constitute the arrhythmogenic substrate (AS). Late gadolinium enhancement cardiac magnetic resonance also improves the arrhythmia-free survival when used to guide ventricular tachycardia (VT) substrate ablation. However, its availability may be limited. We sought to evaluate the performance of multidetector cardiac computed tomography (MDCT) imaging in identifying HTCs detected by LGE-CMR in ischaemic patients undergoing VT substrate ablation. METHODS AND RESULTS: Thirty ischaemic patients undergoing both LGE-CMR and MDCT before VT substrate ablation were included. Using a dedicated post-processing software, two blinded operators, assigned either to LGE-CMR or MDCT analysis, characterized the presence of CMR and computed tomography (CT) channels, respectively. Cardiac magnetic resonance channels were classified as endocardial (layers < 50%), epicardial (layers ≥ 50%), or transmural. Cardiac magnetic resonance- vs. CT-channel concordance was considered when showing the same orientation and American Heart Association (AHA) segment. Mean age was 69 ± 10 years; 90% were male. Mean left ventricular ejection fraction was 35 ± 10%. All patients had CMR channels (n = 76), whereas only 26/30 (86.7%) had CT channels (n = 91). Global sensitivity (Se) and positive predictive values for detecting CMR channels were 61.8% and 51.6%, respectively. MDCT performance improved in patients with epicardial CMR channels (Se 80.5%) and transmural scars (Se 72.2%). In 4/11 (36%) patients with subendocardial myocardial infarction (MI), MDCT was unable to identify the AS. CONCLUSIONS: Compared to LGE-CMR, myocardial wall thickness assessment using MDCT fails to detect the presence of AS in 36% of patients with subendocardial MI, showing modest sensitivity identifying HTCs but a better performance in patients with transmural scars.


Asunto(s)
Medios de Contraste , Taquicardia Ventricular , Anciano , Gadolinio , Humanos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Volumen Sistólico , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Función Ventricular Izquierda
12.
Pacing Clin Electrophysiol ; 44(6): 1115-1125, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33527461

RESUMEN

Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) and multidetector cardiac computed tomography (MDCT) have emerged as novel, fascinating imaging tools for arrhythmogenic substrate identification and characterization. The role of these techniques for aiding and guiding the catheter ablation of ventricular tachycardia, either as a complement or a surrogate of the electroanatomic map, has been rising in recent years. Integrating pixel signal intensity maps or wall thickness maps delivered from LGE-CMR or MDCT, respectively, into the navigation system has become a cornerstone for VT ablation procedures in a few centers of excellence around the world. The pre-procedure scar characterization offers some advantages, helping decide for the best procedure planning and approach; complete substrate identification and characterization, helping to focus electroanatomical mapping in regions of interest and also has a positive impact in procedure efficiency and outcomes. In the present article, we perform a review of the most practical aspects for using LGE-CMR or MDCT when a VT ablation procedure is planned, from the image acquisition to the integration into the navigation system, analyzing the current role of the LGE-CMR and MDCT for arrhythmogenic substrate characterization as well as for guiding VT ablation.


Asunto(s)
Ablación por Catéter , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada Multidetector/métodos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Medios de Contraste , Humanos , Taquicardia Ventricular/fisiopatología
13.
Pacing Clin Electrophysiol ; 44(5): 824-834, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33742716

RESUMEN

BACKGROUND: Left atrial wall thickness (LAWT) has been related to pulmonary vein (PV) reconnections after atrial fibrillation (AF) ablation. The aim was to integrate 3D-LAWT maps in the navigation system and analyze the relationship with local reconnection sites during AF-redo procedures. METHODS: Consecutive patients referred for AF-redo ablation were included. Procedure was performed using a single catheter technique. LAWT maps obtained from multidetector computerized tomography (MDCT) were imported into the navigation system. LAWT of the circumferential PV line, the reconnected segment and the reconnected point, were analyzed. RESULTS: Sixty patients [44 (73%) male, age 61 ± 10 years] were included. All reconnected veins were isolated using a single catheter technique with 55 min (IQR 47-67) procedure time and 75 s (IQR 50-120) fluoroscopy time. Mean LAWT of the circumferential PV line was 1.46 ± 0.22 mm. The reconnected segment was thicker than the rest of segments of the circumferential PV line (2.05 + 0.86 vs. 1.47 + 0.76, p < .001 for the LPVs; 1.55 + 0.57 vs. 1.27 + 0.57, p < .001 for the RPVs). Mean reconnection point wall thickness (WT) was at the 82nd percentile of the circumferential line in the LPVs and at the 82nd percentile in the RPVs. CONCLUSION: A single catheter technique is feasible and efficient for AF-redo procedures. Integrating the 3D-LAWT map into the navigation system allows a direct periprocedural estimation of the WT at any point of the LA. Reconnection points were more frequently present in thicker segments of the PV line. The use of 3D-LAWT maps can facilitate reconnection point identification during AF-redo ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Atrios Cardíacos/anatomía & histología , Atrios Cardíacos/diagnóstico por imagen , Venas Pulmonares/cirugía , Tomografía Computarizada por Rayos X , Fibrilación Atrial/diagnóstico por imagen , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Recurrencia , Reoperación
14.
J Interv Cardiol ; 2020: 4386841, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32549801

RESUMEN

BACKGROUND: Voltage mapping allows identifying the arrhythmogenic substrate during scar-related ventricular arrhythmia (VA) ablation procedures. Slow conducting channels (SCCs), defined by the presence of electrogram (EGM) signals with delayed components (EGM-DC), are responsible for sustaining VAs and constitute potential ablation targets. However, voltage mapping, as it is currently performed, is time-consuming, requiring a manual analysis of all EGMs to detect SCCs, and its accuracy is limited by electric far-field. We sought to evaluate an algorithm that automatically identifies EGM-DC, classifies mapping points, and creates new voltage maps, named "Slow Conducting Channel Maps" (SCC-Maps). METHODS: Retrospective analysis of electroanatomic maps (EAM) from 20 patients (10 ischemic, 10 with arrhythmogenic right ventricular dysplasia/cardiomyopathy) was performed. EAM voltage maps were acquired during sinus rhythm and used for ablation. Preprocedural contrast-enhanced cardiac magnetic resonance (Ce-CMR) imaging was available for the ischemic population. Three mapping modalities were analysed: (i) EAM voltage maps using standard (EAM standard) or manual (EAM screening) thresholds for defining core and border zones; (ii) SCC-Maps derived from the use of the novel SCC-Mapping algorithm that automatically identify EGM-DCs measuring the voltage of the local component; and (iii) Ce-CMR maps (when available). The ability of each mapping modality in identifying SCCs and their agreement was evaluated. RESULTS: SCC-Maps and EAM screening identified a greater number of SCC entrances than EAM standard (3.45 ± 1.61 and 2.95 ± 2.31, resp., vs. 1.05 ± 1.10; p < 0.01). SCC-Maps and EAM screening highly correlate with Ce-CMR maps in the ischemic population when compared to EAM standard (Lin's correlation = 0.628 and 0.679, resp., vs. 0.212, p < 0.01). CONCLUSION: The SCC-Mapping algorithm allows an operator-independent analysis of EGM signals showing better identification of the arrhythmogenic substrate characteristics when compared to standard voltage EAM.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/fisiopatología , Ablación por Catéter , Taquicardia Ventricular/etiología , Adulto , Anciano , Arritmias Cardíacas/cirugía , Displasia Ventricular Derecha Arritmogénica/cirugía , Cicatriz/patología , Cicatriz/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Taquicardia Ventricular/diagnóstico
15.
Europace ; 22(9): 1419-1430, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32607538

RESUMEN

AIMS: A pre-operative non-invasive identification of the site of origin (SOO) of outflow tract ventricular arrhythmias (OTVAs) is important to properly plan radiofrequency ablation procedures. Although some algorithms based on electrocardiograms (ECGs) have been developed to predict left vs. right ventricular origins, their accuracy is still limited, especially in complex anatomies. The aim of this work is to use patient-specific electrophysiological simulations of the heart to predict the SOO in OTVA patients. METHODS AND RESULTS: An in silico pace-mapping procedure was designed and used on 11 heart geometries, generating for each case simulated ECGs from 12 clinically plausible SOO. Subsequently, the simulated ECGs were compared with patient ECG data obtained during the clinical tachycardia using the 12-lead correlation coefficient (12-lead ρ). Left ventricle (LV) vs. right ventricle (RV) SOO was estimated by computing the LV/RV ratio for each patient, obtained by dividing the average 12-lead ρ value of the LV- and RV-SOO simulated ECGs, respectively. Simulated ECGs that had virtual sites close to the ablation points that stopped the arrhythmia presented higher correlation coefficients. The LV/RV ratio correctly predicted LV vs. RV SOO in 10/11 cases; 1.07 vs. 0.93 P < 0.05 for 12-lead ρ. CONCLUSION: The obtained results demonstrate the potential of the developed in silico pace-mapping technique to complement standard ECG for the pre-operative planning of complex ventricular arrhythmias.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Simulación por Computador , Electrocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía
16.
Europace ; 22(9): 1391-1400, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32898254

RESUMEN

AIMS: Sudden cardiac death (SCD) risk estimation in patients referred for cardiac resynchronization therapy (CRT) remains a challenge. By CRT-mediated improvement of left ventricular ejection fraction (LVEF), many patients loose indication for primary prevention implantable cardioverter-defibrillator (ICD). Increasing evidence shows the importance of myocardial scar for risk prediction. The aim of this study was to investigate the prognostic impact of myocardial scar depending on the echocardiographic response in patients undergoing CRT. METHODS AND RESULTS: Patients with indication for CRT were prospectively enrolled. Decision about ICD or pacemaker implantation was based on clinical criteria. All patients underwent delayed-enhancement cardiac magnetic resonance imaging. Median follow-up duration was 45 (24-75) months. Primary outcome was a composite of sustained ventricular arrhythmia, appropriate ICD therapy, or SCD. A total of 218 patients with LVEF 25.5 ± 6.6% were analysed [158 (73%) male, 64.9 ± 10.7 years]. Myocardial scar was observed in 73 patients with ischaemic cardiomyopathy (ICM) (95% of ICM patients); in 62 with non-ischaemic cardiomyopathy (45% of these patients); and in all but 1 of 36 (17%) patients who reached the primary outcome. Myocardial scar was the only significant predictor of primary outcome [odds ratio 27.7 (3.8-202.7)], independent of echocardiographic CRT response. A total of 55 (25%) patients died from any cause or received heart transplant. For overall survival, only a combination of the absence of myocardial scar with CRT response was associated with favourable outcome. CONCLUSION: Malignant arrhythmic events and SCD depend on the presence of myocardial scar but not on CRT response. All-cause mortality improved only with the combined absence of myocardial scar and CRT response.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Arritmias Cardíacas , Cicatriz/diagnóstico por imagen , Cicatriz/patología , Muerte Súbita Cardíaca/prevención & control , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
17.
Europace ; 22(2): 274-280, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31942618

RESUMEN

AIMS: Frequent premature ventricular complexes (PVCs) can induce or worsen left ventricular systolic dysfunction. We aimed to investigate the influence of the baseline QRS in the response after PVC ablation in patients with depressed left ventricular ejection fraction (LVEF). METHODS AND RESULTS: Two hundred and fifteen [59 ± 13 years old, 152 (71%) men] consecutive patients with left ventricular (LV) systolic dysfunction and frequent PVCs referred for ablation were included and followed-up for 12 months. Echocardiographic response was defined as an improvement of at least five absolute points in LVEF. Clinical, electrocardiogram, and electrophysiological characteristics were analysed. Mean baseline QRS duration was 110 ms [97-140]. Premature ventricular complex burden significantly decreased after ablation from 23% [16-33] at baseline to 1% [0-8] at 12 months, P < 0.001. Mean PVC burden reduction was 18 [8-30] points. There was a significant improvement of LVEF from 35% [29-40] at baseline to 44% [35-55] at 12 months, P < 0.001. One hundred and thirty (61%) patients were considered as echocardiographic responders. Baseline QRS duration (ms) [odds ratio (OR) 0.98 (0.97-0.99), P = 0.01] was an independent predictor of echocardiographic response. Mean LVEF improvement was 16 [10-21] points when the baseline QRS duration was <90 ms; 12 [4-20] when it was 90-110 ms; 5 [0-15] when it was 110 ± 130 ms; and 0 [0-6] points when it was >130 ms. CONCLUSIONS: In patients with LV systolic dysfunction, intrinsic QRS duration is inversely related to the probability and the degree of echocardiographic response after frequent PVC ablation. Patients with a QRS duration >130 ms at baseline have the poorer response after ablation.


Asunto(s)
Ablación por Catéter , Disfunción Ventricular Izquierda , Complejos Prematuros Ventriculares , Anciano , Electrocardiografía , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/cirugía , Función Ventricular Izquierda , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía
18.
Europace ; 21(1): 147-153, 2019 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-30016418

RESUMEN

AIMS: Left ventricular (LV) outflow tract ventricular arrhythmias (OTVA) are associated with hypertension (HT), older age, and LV dysfunction, suggesting that LV overload plays a role in the aetiopathogenesis. We hypothesized that anatomical modifications of the LV outflow tract (LVOT) could predict left vs. right OTVA site of origin (SOO). METHODS AND RESULTS: Fifty-six (32 men, 53 ± 18 years old) consecutive patients referred for OTVA ablation were included. Cardiac multidetector computed tomography was performed before ablation and then imported to the CARTO system to aid the mapping and ablation procedure. Anatomical characteristics of the aortic root as well as aortopulmonary valvular planar angulation (APVPA) were analysed. The LV was the OTVA SOO (LVOT-VA) in 32 (57%) patients. These patients were more frequently male (78% vs. 22%, P = 0.001), older (57 ± 18 vs. 47 ± 18 years, P = 0.055), and more likely to have HT (59% vs. 21%, P = 0.004), compared to right OTVA patients. Aortopulmonary valvular planar angulation was higher in LVOT-VA patients (68 ± 5° vs. 55 ± 6°, respectively; P < 0.001). Absolute size of all aortic root diameters was associated with LVOT origin. However, after indexing by body surface area, only sinotubular junction diameter maintained a significant association (P = 0.049). Multivariable analysis showed that APVPA was an independent predictor of LVOT origin. Aortopulmonary valvular planar angulation ≥62° reached 94% sensitivity and 83% specificity (area under the curve 0.95) for predicting LVOT origin. CONCLUSIONS: The measurement of APVPA as a marker of chronic LV overload is useful for the prediction of left vs. right ventricular OTVA origin.


Asunto(s)
Ventrículos Cardíacos/diagnóstico por imagen , Tomografía Computarizada Multidetector , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Función Ventricular Derecha , Complejos Prematuros Ventriculares/etiología , Remodelación Ventricular , Potenciales de Acción , Adulto , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Factores de Riesgo , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/fisiopatología , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/cirugía
19.
Europace ; 21(7): 1079-1087, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-30904923

RESUMEN

AIMS: Ablation of frequent premature ventricular complexes (PVCs) improves left ventricular ejection fraction in patients with left ventricular (LV) systolic dysfunction. This study aims to evaluate the long-term hard outcomes and potential prognostic variables in this population. METHODS AND RESULTS: Prospective multicentre study including 101 consecutive patients [56 ± 12 years old, 62 (61%) men] with LV systolic dysfunction and frequent PVCs who underwent PVC ablation before November 2015. The last evaluation performed was considered the long-term follow-up (LTFUP) evaluation. Mean follow-up was 34 ± 16 months (range 24-84 months). Ablation was successful in 95 (94%) patients. There was a significant reduction in the PVC burden from 21 ± 12% at baseline to 3.8 ± 6% at LTFUP, P < 0.001. Left ventricular ejection fraction improved from 32 ± 8% at baseline to 39 ± 12% at LTFUP (P < 0.001) and New York Heart Association class from 2.2 ± 0.6% to 1.3 ± 0.6% (P < 0.001). Brain natriuretic peptide levels decreased from 136 (78-321) to 68 (32-144) pg/mL (P = 0.007). Most of this improvement occurs during the first 6 months after ablation. Persistent abolition of at least 18 points of the baseline PVC burden was independently and inversely associated with the composite endpoint of cardiac mortality, cardiac transplantation, or hospitalization for heart failure during follow-up [hazard ratio 0.18 (0.05-0.66), P = 0.01]. CONCLUSION: In patients with LV systolic dysfunction, ablation of frequent PVCs induces a significant improvement in functional, structural, and neurohormonal status, which persists at LTFUP. A sustained reduction in the baseline PVC burden is associated with a lower risk of cardiac mortality, cardiac transplantation, or hospitalization for heart failure during follow-up.


Asunto(s)
Ablación por Catéter/métodos , Disfunción Ventricular Izquierda/cirugía , Complejos Prematuros Ventriculares/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Volumen Sistólico , Sístole , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/fisiopatología , Complejos Prematuros Ventriculares/mortalidad , Complejos Prematuros Ventriculares/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA