Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Sci Rep ; 12(1): 15855, 2022 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-36151262

RESUMEN

This paper presents the gamma-ray detection performance of the newly developed MAPD-3NM-II type SiPM sensor array (4 [Formula: see text] 4) with [Formula: see text](Ce) scintillator. The gamma-ray spectra of various sources have been measured in the energy range from 26 keV up to 1332 keV. The newly developed array based on MAPD-3NM-II sensors proved [Formula: see text] 22% enhancement in energy resolution in comparison to the former MAPD-3NM-I based array. The energy resolution of 662 keV gamma-rays measured by MAPD-3NM-II was 3.3% while clearly surpassing 4.25% resolution of MAPD-3NM-I predecessor. The enhancement is related to the high PDE of the new MAPD-3NM-II. Obtained results show that the new MAPD-3NM-II demonstrated good energy resolution and linearity in the studied energy region. The energy resolution of the new detector developed based on MAPD-3NM-II was better than all previous products of MAPD.

2.
Radiat Prot Dosimetry ; 191(2): 176-180, 2020 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-33140088

RESUMEN

Three experiments were conducted with a volunteer to test the kinetics of the 222Rn exhalation after a short-time exposure to an elevated 222Rn air concentration. Radon concentration in an exhaled air was measured, complemented by whole body counting of 222Rn decay products in a body. Exhaled activities are compared with the prediction of the recent ICRP biokinetic model for radon. While a rapid equilibration of the exhaled radon activity concentration with that in the air inhaled corresponded with the model, the measured 222Rn exhalation rate was significantly less than modelled. Five hours after termination of the inhalation phase, the radon concentration in the exhaled air decreased to levels expected for non-elevated indoor radon activity concentration. Whole body activities of the 222Rn decay products were found higher than expected. Inhalation of the unattached fraction or residual activity of decay products in the air inhaled may be the explanation.


Asunto(s)
Contaminantes Radiactivos del Aire , Contaminación del Aire Interior , Radón , Contaminantes Radiactivos del Aire/análisis , Contaminación del Aire Interior/análisis , Espiración , Humanos , Cinética , Radón/análisis
3.
J Environ Radioact ; 190-191: 134-140, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29793183

RESUMEN

The main limitation in the high-sensitive HPGe gamma-ray spectrometry has been the detector background, even for detectors placed deep underground. Environmental radionuclides such as 40K and decay products in the 238U and 232Th chains have been identified as the most important radioactive contaminants of construction parts of HPGe gamma-ray spectrometers. Monte Carlo simulations have shown that the massive inner and outer lead shields have been the main contributors to the HPGe-detector background, followed by aluminum cryostat, copper cold finger, detector holder and the lead ring with FET. The Monte Carlo simulated cosmic-ray background gamma-ray spectrum has been by about three orders of magnitude lower than the experimental spectrum measured in the Modane underground laboratory (4800 m w.e.), underlying the importance of using radiopure materials for the construction of ultra-low-level HPGe gamma-ray spectrometers.


Asunto(s)
Monitoreo de Radiación , Contaminantes Radiactivos/análisis , Espectrometría gamma , Simulación por Computador , Francia , Rayos gamma , Laboratorios , Método de Montecarlo , Radioisótopos , Torio/análisis , Uranio/análisis
4.
Radiat Prot Dosimetry ; 116(1-4 Pt 2): 16-8, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16604587

RESUMEN

The radioactivity induced in the forward shielding, copper collimator and semiconductor tracker modules of the ATLAS detector has been studied. The ATLAS detector is a long-term experiment which, during operation, will require to have service and access to all of its parts and components. The radioactivity induced in the forward shielding was calculated by Monte Carlo methods based on GEANT3 software tool. The results show that the equivalent dose rates on the outer surface of the forward shielding are very low (at most 0.038 microSv h(-1)). On the other hand, the equivalent dose rates are significantly higher on the inner surface of the forward shielding (up to 661 microSv h(-1)) and, especially, at the copper collimator close to the beampipe (up to 60 mSv h(-1)). The radioactivity induced in the semiconductor tracker modules was studied experimentally. The module was activated by neutrons in a training nuclear reactor and the delayed gamma ray spectra were measured. From these measurements, the equivalent dose rate on the surface of the semiconductor tracker module was estimated to be < 100 microSv h(-1) after 100 d of Large Hadron Collider (LHC) operation and 10 d of cooling.


Asunto(s)
Materiales de Construcción/análisis , Análisis de Falla de Equipo , Transferencia Lineal de Energía , Aceleradores de Partículas/instrumentación , Protección Radiológica/instrumentación , Radioisótopos/análisis , Radiometría/instrumentación , Ensayo de Materiales , Dosis de Radiación , Protección Radiológica/métodos , Radiometría/métodos , Semiconductores
5.
J Environ Radioact ; 114: 66-70, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22498792

RESUMEN

The radioactivity levels in the air of the radionuclides released by the Fukushima accident were measured at the Laboratoire Souterrain de Modane, in the South-East of France, during the period 25 March-18 April 2011. Air-filters from the ventilation system exposed for one or two days were measured using low-background gamma-ray spectrometry. In this paper we present the activity concentrations obtained for the radionuclides (131)I, (132)Te, (134)Cs, (137)Cs, (95)Nb, (95)Zr, (106)Ru, (140)Ba/La and (103)Ru. The activity concentration of (131)I was of the order of 100 µBq/m(3), more than 100 times higher than the activities of other fission products. The highest activities of (131)I were measured as a first peak on 30 March and a second peak on 3-4 April. The activity concentrations of (134)Cs and (137)Cs varied from 5 to 30 µBq/m(3). The highest activity concentration recorded for Cs corresponded to the same period as for (131)I, with a peak on 2-3 April. The results of the radioactivity concentration levels in grass and mushrooms exposed to the air in the Modane region were also measured. Activity concentrations of (131)I of about 100 mBq/m(2) were found in grass.


Asunto(s)
Contaminantes Radiactivos del Aire/análisis , Accidente Nuclear de Fukushima , Radioisótopos/análisis , Agaricales/química , Contaminación Radiactiva de Alimentos/análisis , Francia , Japón , Poaceae/química , Monitoreo de Radiación , Radiactividad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA