Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 188
Filtrar
1.
Circulation ; 148(1): 35-46, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37199171

RESUMEN

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Aleteo Atrial/etiología , Sistema de Registros , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
2.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38861398

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as 'sense-B-noise.' It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. METHODS AND RESULTS: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23-64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2-70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. CONCLUSION: This multicentre analysis' findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica , Sistema de Registros , Humanos , Masculino , Estudios Retrospectivos , Femenino , Persona de Mediana Edad , Incidencia , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Anciano , Europa (Continente)/epidemiología , Falla de Equipo/estadística & datos numéricos , Estados Unidos/epidemiología , Factores de Riesgo
3.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38885309

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD), that led to an advisory for nearly 40 000 patients. This multicentre study evaluated the incidence of PBD in a large set of S-ICD patients. METHODS AND RESULTS: Data from patients implanted with S-ICD models A209 and A219 between October 2012 and July 2023 across nine centres in Europe and the USA were reviewed. Incidence and implications of PBD, defined as clinically observed sudden drop in battery longevity, were analysed and compared to PBD with the definition of battery depletion within 60 months. Prospectively collected clinical data were obtained retrospectively from medical records, device telemetry, and manufacturer reports. This registry is listed on ClinicalTrials.gov (NCT05713708). Of the 1112 S-ICD devices analysed, 547 (49.2%) were equipped with a potentially affected capacitor linked to PBD occurrence, currently under Food and Drug Administration advisory. The median follow-up time for all patients was 46 [inter-quartile range (IQR) 24-63] months. Clinically suspected PBD was observed in 159 (29.1%) of cases, with a median time to generator removal or replacement of 65 (IQR 55-72) months, indicative of significant deviations from expected battery lifespan. Manufacturer confirmation of PBD was made in 91.7% of devices returned for analysis. No cases of PBD were observed in devices that were not under advisory. CONCLUSION: This manufacturer-independent analysis highlights a notable incidence of PBD in patients equipped with S-ICD models under advisory, and the rate of PBD in this study corresponds to the rate currently estimated by the manufacturer. To the best of our knowledge, this provides the largest contemporary peer-reviewed study cohort investigating the actual incidence of PBD in S-ICD patients. These findings emphasize the importance of post-market registries in collaboration between clinicians and the manufacturer to optimize safety and efficacy in S-ICD treatment.


Asunto(s)
Desfibriladores Implantables , Suministros de Energía Eléctrica , Sistema de Registros , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Estados Unidos/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Europa (Continente)/epidemiología , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Falla de Equipo/estadística & datos numéricos , Factores de Tiempo , Análisis de Falla de Equipo/estadística & datos numéricos , Adulto
4.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38587017

RESUMEN

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , América Latina , Resultado del Tratamiento , Catéteres , Asia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
5.
J Cardiovasc Electrophysiol ; 34(10): 2019-2026, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37682001

RESUMEN

INTRODUCTION: Pulmonary vein isolation (PVI) remains the cornerstone in the treatment of atrial fibrillation (AF). PVI using cryoballoon (CB) technology has emerged as a standard procedure in many centers. Recently, pulsed field ablation (PFA) has been introduced and used to achieve PVI. First data show high acute and favorable long-term outcomes. So far, data comparing these new "single shot" devices are sparse. We sought to compare procedural and outcome data for first time PFA users versus CB in patients undergoing de novo PVI. Furthermore, potentially postprocedural discomfort and affection of autonomic ganglia were assessed. METHODS AND RESULTS: A retrospective analysis and comparison of all de novo PVIs with PFA and CB was performed. Furthermore, PFA PVI learning curve was evaluated. During follow-up, repeat outpatient visits and Holter electrocardiogram were performed to analyze arrhythmia-free survival. Discomfort analysis was obtained by prescribed analgesic medication within first 48 h after PVI. Potential changes in heart rate (HR) between baseline and at 3-month follow-up were evaluated. A total of 108 patients (54 PFA and 54 CB; PFA; 33 (30%) female) with paroxysmal and persistent AF were analyzed. Type of AF was comparable (Patients suffering from PAF: PFA: 16 (30%), CB: 17 (31%), p = 1.0). In 107 (99%) patients, successful PVI was achieved. Transient phrenic palsy omitted complete PVI in one CB patient. A trend for a shorter overall procedure duration was observed in the PFA group (PFA: 64.5 ± 17.5 min; CB: 73.0 ± 24.8 min; p = 0.07). Excluding LA mapping time (first 14 cases), procedure time was significantly shorter using PFA (PFA: 58.0 ± 12.5 min, CB: 73.0 ± 24.8 min, p = 0.0001). Fluoroscopy time was significantly longer for PFA (PFA: 15.3 ± 4.7 min, CB: 12.3 ± 5.3 min; p = 0.001), but significantly less contrast medium was used (PFA: 12 ± 6 mL; CB: 51 ± 29 mL, p < 0.0001). Subgroup analysis of the PFA group revealed a significant shortening of procedure duration over time (first tertile: 72.7 ± 13.5 min, second tertile: 67.3 ± 21.7 min, third tertile: 53.4 ± 9.8 min, first vs. third tertile p < 0.0001). Two cardiac tamponades occurred in the PFA group (p = 0.495), of which one was most likely related to complex transseptal puncture. In the first 48 h after PVI, the number of prescribed analgesics due to postprocedural pain was equal between both groups (PFA: 7 (13%) patients, CB: 10 (19%) patients, p = 0.598). After a FU of 273 ± 129 days, 35 of 47 patients (74%) after PFA and 36 of 50 patients (72%) after CB PVI were free of any atrial arrhythmia (HR: 0.98, p = 0.88). Only in the PFA group, a significant increase in HR 3 months after PVI was observed (pre-PVI: 61 ± 8 beats/min, post-PVI: 65 ± 9 beats/min, p = 0.008). CONCLUSION: The new PFA technology is equally effective and safe as compared to CB for complete PVI with potentially shorter procedure time and significantly less contrast medium. However, AF recurrence rates after PFA PVI seem to be comparable to CB PVI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Femenino , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Ablación por Catéter/métodos , Recurrencia
6.
J Cardiovasc Electrophysiol ; 34(12): 2417-2424, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37846194

RESUMEN

BACKGROUND: The newly introduced nonthermal pulsed field ablation (PFA) is a promising technology to achieve fast pulmonary vein isolation (PVI) with high acute success rates and good safety features. However, previous studies have shown that very high power short duration ablation (VHPSD) is also highly effective and fast to achieve PVI with potentially less arrhythmia recurrence compared to conventional radiofrequency ablation. Data comparing PFA to VHPSD-PVI is lacking. OBJECTIVE: This study compared procedural and outcome data for PFA-PVI to VHPSD-PVI in patients with paroxysmal or persistent atrial fibrillation (PAF/persAF). METHODS: Consecutive patients undergoing de novo PVI (PFA or VHPSD) were included in this analysis. For PFA-PVI a pentaspline 20 electrode catheter was used. For VHPSD-PVI an enhanced irrigated catheter with a power setting of 70 W/7 s (70 W/5 s at posterior wall) was employed in conjunction with electro-anatomical mapping. All procedures were performed in deep analgo-sedation. RESULTS: A total of n = 114 patients (n = 57[50%] PFA, n = 17[30%] PAF; n = 40[70%] persAF) were included in this analysis. PVI was successful in all patients. The PFA group revealed a significantly shorter procedure duration (65 ± 17 min vs. 95 ± 23 min, p < 0.01) but longer fluoroscopy time (PFA 15 ± 5 min and VHPSD 12 ± 3 min; p < 0.001). At follow-up after median 125 days (interquartile range: 109-162) n = 46 PFA (80.7%) and n = 44 VHPSD pts (77.2%) were free from atrial arrhythmia after a single procedure (p = 0.819). Two tamponades occurred in the PFA while in VHPSD two pts suffered groin bleedings. One clinically nonsignificant PV stenosis occurred in the VHPSD group. CONCLUSION: Pulsed-field ablation and VHPSD-PVI seem to be highly effective and safe to achieve PVI in the setting of PAF and persAF with comparable arrhythmia-free survival. However, procedure duration for PFA PVI is significantly shorter and therefore may be of potential benefit. Compared to PFA VHPSD-PVI might ensure information on left atrial substrate allowing to target concomitant secondary tachycardias.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Resultado del Tratamiento , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Atrios Cardíacos , Recurrencia
7.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37713241

RESUMEN

AIMS: Preprocedural transoesophageal echocardiography (TEE) screening for left atrial (LA) thrombi is the standard of care in many centres performing atrial fibrillation (AF) ablation. However, TEE imposes procedural risks for patients and is often challenging to implement in daily practice, besides causing patient discomfort. At our centre, a novel standard operating procedure (SOP) was implemented, aiming to identify patients that can be exempt from TEE screening. We aimed to assess whether this screening approach may reduce preprocedural TEEs without imposing patients of higher risks for cerebrovascular events (CVEs). METHODS AND RESULTS: Data of 1874 consecutive patients treated by catheter ablation of LA arrhythmias between 2018 and 2022 were retrospectively analysed. A cohort of 937 patients, where decision to perform TEE screening was based on a new SOP (considering rhythm at admission, CHA2DS2-VASc score, and sufficient anticoagulation), was compared to a matched cohort receiving TEE before every procedure. Number of performed TEEs and incidences of CVEs were compared. Implementation of the new SOP led to a 67% reduction in TEEs performed (old SOP: 933 vs. new SOP: 305). No significant differences between the groups were detected regarding transitory ischaemic attack (old SOP: 5 vs. new SOP: 3; P = 0.48) and stroke (no events). No solid thrombi were detected during TEE screening. CONCLUSION: The number of preprocedural screening TEEs before AF ablation procedures can be safely reduced by applying risk stratification based on rhythm at admission and CHA2DS2-VASc score, if anticoagulation was performed properly.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Cardiopatías , Trombosis , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Ecocardiografía Transesofágica , Estudios Retrospectivos , Trombosis/etiología , Anticoagulantes , Ablación por Catéter/efectos adversos , Apéndice Atrial/cirugía
8.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37072340

RESUMEN

AIMS: RECOVER AF evaluated the performance of whole-chamber non-contact charge-density mapping to guide the ablation of non-pulmonary vein (PV) targets in persistent atrial fibrillation (AF) patients following either a first or second failed procedure. METHODS AND RESULTS: RECOVER AF was a prospective, non-randomized trial that enrolled patients scheduled for a first or second ablation retreatment for recurrent AF. The PVs were assessed and re-isolated if necessary. The AF maps were used to guide the ablation of non-PV targets through elimination of pathologic conduction patterns (PCPs). Primary endpoint was freedom from AF on or off antiarrhythmic drugs (AADs) at 12 months. Patients undergoing retreatment with the AcQMap System (n = 103) were 76% AF-free at 12 months [67% after single procedure (SP)] on or off AADs (80% free from AF on AADs). Patients who had only received a pulmonary vein isolation (PVI) prior to study treatment of non-PV targets with the AcQMap System were 91% AF-free at 12 months (83% SP). No major adverse events were reported. CONCLUSION: Non-contact mapping can be used to target and guide the ablation of PCPs beyond the PVs in persistent AF patients returning for a first or second retreatment with 76% freedom from AF at 12 months. The AF freedom was particularly high, 91% (43/47), for patients enrolled having only a prior de novo PVI, and freedom from all atrial arrhythmias for this cohort was 74% (35/47). These early results are encouraging and suggest that guiding individualized targeted ablation of PCPs may therefore be advantageous to target at the earliest opportunity in patients with persistent AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Estudios Prospectivos , Venas Pulmonares/cirugía , Retratamiento , Antiarrítmicos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento , Recurrencia
9.
Europace ; 25(2): 374-381, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36414239

RESUMEN

AIMS: Cryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures. METHODS AND RESULTS: In the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence. CONCLUSION: In patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Criocirugía/métodos , Nervio Frénico , Venas Pulmonares/cirugía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
10.
Europace ; 24(8): 1256-1266, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35647644

RESUMEN

AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Accidente Cerebrovascular , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Persona de Mediana Edad , Venas Pulmonares/cirugía , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Adulto Joven
11.
Circulation ; 141(13): 1057-1067, 2020 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-32000514

RESUMEN

BACKGROUND: Catheter ablation for ventricular tachycardia (VT) reduces the recurrence of VT in patients with implantable cardioverter-defibrillators (ICDs). The appropriate timing of VT ablation and its effects on mortality and heart failure progression remain a matter of debate. In patients with life-threatening arrhythmias necessitating ICD implantation, we compared outcomes of preventive VT ablation (undertaken before ICD implantation to prevent ICD shocks for VT) and deferred ablation after 3 ICD shocks for VT. METHODS: The BERLIN VT study (Preventive Ablation of Ventricular Tachycardia in Patients With Myocardial Infarction) was a prospective, open, parallel, randomized trial performed at 26 centers. Patients with stable ischemic cardiomyopathy, a left ventricular ejection fraction between 30% and 50%, and documented VT were randomly assigned 1:1 to a preventive or deferred ablation strategy. The primary outcome was a composite of all-cause death and unplanned hospitalization for either symptomatic ventricular arrhythmia or worsening heart failure. Secondary outcomes included sustained ventricular tachyarrhythmia and appropriate ICD therapy. We hypothesized that preventive ablation strategy would be superior to deferred ablation strategy in the intention-to-treat population. RESULTS: During a mean follow-up of 396±284 days, the primary end point occurred in 25 (32.9%) of 76 patients in the preventive ablation group and 23 (27.7%) of 83 patients in the deferred ablation group (hazard ratio, 1.09 [95% CI, 0.62-1.92]; P=0.77). On the basis of prespecified criteria for interim analyses, the study was terminated early for futility. In the preventive versus deferred ablation group, 6 versus 2 patients died (7.9% versus 2.4%; P=0.18), 8 versus 2 patients were admitted for worsening heart failure (10.4% versus 2.3%; P=0.062), and 15 versus 21 patients were hospitalized for symptomatic ventricular arrhythmia (19.5% versus 25.3%; P=0.27). Among secondary outcomes, the proportions of patients with sustained ventricular tachyarrhythmia (39.7% versus 48.2%; P=0.050) and appropriate ICD therapy (34.2% versus 47.0%; P=0.020) were numerically reduced in the preventive ablation group. CONCLUSIONS: Preventive VT ablation before ICD implantation did not reduce mortality or hospitalization for arrhythmia or worsening heart failure during 1 year of follow-up compared with the deferred ablation strategy. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02501005.


Asunto(s)
Cardiomiopatías/complicaciones , Ablación por Catéter/métodos , Desfibriladores Implantables/normas , Taquicardia Ventricular/terapia , Anciano , Cardiomiopatías/cirugía , Femenino , Humanos , Masculino , Estudios Prospectivos
12.
Europace ; 23(10): 1548-1558, 2021 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-33895833

RESUMEN

AIMS: Weight management seems to be beneficial for obese atrial fibrillation (AF) patients; however, randomized data are sparse. Thus, this study aimed to investigate the influence of weight reduction on AF ablation outcomes. METHODS AND RESULTS: SORT-AF is an investigator-sponsored, prospective, randomized, multicentre, and clinical trial. Patients with symptomatic AF (paroxysmal or persistent) and body mass index (BMI) 30-40 kg/m2 underwent AF ablation and were randomized to either weight-reduction (group 1) or usual care (group 2), after sleep-apnoea-screening and loop recorder (ILR) implantation. The primary endpoint was defined as AF burden between 3 and 12 months after AF ablation. Overall, 133 patients (60 ± 10 years, 57% persistent AF) were randomized to group 1 (n = 67) and group 2 (n = 66), respectively. Complications after AF-ablation were rare (one stroke and no tamponade). The intervention led to a significant reduction of BMI (34.9 ± 2.6-33.4 ± 3.6) in group 1 compared to a stable BMI in group 2 (P < 0.001). Atrial fibrillation burden after ablation decreased significantly (P < 0.001), with no significant difference regarding the primary endpoint between the groups (P = 0.815, odds ratio: 1.143, confidence interval: 0.369-3.613). Further analyses showed a significant correlation between BMI and AF recurrence for patients with persistent AF compared with paroxysmal AF patients (P = 0.032). CONCLUSION: The SORT-AF study shows that AF ablation is safe and successful in obese patients using continuous monitoring via ILR. Although the primary endpoint of AF burden after ablation did not differ between the two groups, the effects of weight loss and improvement of exercise activity were beneficial for obese patients with persistent AF demonstrating the relevance of life-style management as an important adjunct to AF ablation in this setting. TRIAL REGISTRATION NUMBER: NCT02064114.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Persona de Mediana Edad , Obesidad/complicaciones , Obesidad/diagnóstico , Estudios Prospectivos , Recurrencia , Resultado del Tratamiento
13.
Europace ; 23(7): 1003-1015, 2021 07 18.
Artículo en Inglés | MEDLINE | ID: mdl-33822029

RESUMEN

AIMS: TeleCheck-AF is a multicentre international project initiated to maintain care delivery for patients with atrial fibrillation (AF) during COVID-19 through teleconsultations supported by an on-demand photoplethysmography-based heart rate and rhythm monitoring app (FibriCheck®). We describe the characteristics, inclusion rates, and experiences from participating centres according the TeleCheck-AF infrastructure as well as characteristics and experiences from recruited patients. METHODS AND RESULTS: Three surveys exploring centre characteristics (n = 25), centre experiences (n = 23), and patient experiences (n = 826) were completed. Self-reported patient characteristics were obtained from the app. Most centres were academic (64%) and specialized public cardiology/district hospitals (36%). Majority of the centres had AF outpatient clinics (64%) and only 36% had AF ablation clinics. The time required to start patient inclusion and total number of included patients in the project was comparable for centres experienced (56%) or inexperienced in mHealth use. Within 28 weeks, 1930 AF patients were recruited, mainly for remote AF control (31% of patients) and AF ablation follow-up (42%). Average inclusion rate was highest during the lockdown restrictions and reached a steady state at a lower level after easing the restrictions (188 vs. 52 weekly recruited patients). Majority (>80%) of the centres reported no problems during the implementation of the TeleCheck-AF approach. Recruited patients [median age 64 (55-71), 62% male] agreed that the FibriCheck® app was easy to use (94%). CONCLUSION: Despite different health care settings and mobile health experiences, the TeleCheck-AF approach could be set up within an extremely short time and easily used in different European centres during COVID-19.


Asunto(s)
Fibrilación Atrial , COVID-19 , Aplicaciones Móviles , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Control de Enfermedades Transmisibles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pandemias , Evaluación del Resultado de la Atención al Paciente , SARS-CoV-2
14.
Circulation ; 140(13): 1061-1069, 2019 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-31466479

RESUMEN

BACKGROUND: Atrial arrhythmias are common in patients with implantable cardioverter-defibrillator (ICD). External shocks and internal cardioversion through commanded ICD shock for electrical cardioversion are used for rhythm-control. However, there is a paucity of data on efficacy of external versus internal cardioversion and on the risk of lead and device malfunction. We hypothesized that external cardioversion is noninferior to internal cardioversion for safety, and superior for successful restoration of sinus rhythm. METHODS: Consecutive patients with ICD undergoing elective cardioversion for atrial arrhythmias at 13 centers were randomized in 1:1 fashion to either internal or external cardioversion. The primary safety end point was a composite of surrogate events of lead or device malfunction. Conversion of atrial arrhythmia to sinus rhythm was the primary efficacy end point. Myocardial damage was studied by measuring troponin release in both groups. RESULTS: N=230 patients were randomized. Shock efficacy was 93% in the external cardioversion group and 65% in the internal cardioversion group (P<0.001). Clinically relevant adverse events caused by external or internal cardioversion were not observed. Three cases of pre-existing silent lead malfunction were unmasked by internal shock, resulting in lead failure. Troponin release did not differ between groups. CONCLUSIONS: This is the first randomized trial on external vs internal cardioversion in patients with ICDs. External cardioversion was superior for the restoration of sinus rhythm. The unmasking of silent lead malfunction in the internal cardioversion group suggests that an internal shock attempt may be reasonable in selected ICD patients presenting for electrical cardioversion. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03247738.


Asunto(s)
Arritmias Cardíacas/terapia , Fibrilación Atrial/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/métodos , Anciano , Anciano de 80 o más Años , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Riesgo
15.
J Cardiovasc Electrophysiol ; 30(5): 679-687, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30821012

RESUMEN

INTRODUCTION: Long-term efficacy and safety are uncertain in patients with cardiac implantable electronic devices (CIED) and transvenous leads (TVL) undergoing radiofrequency catheter ablation of atrial fibrillation (AF). Thus, we assessed the outcome of AF ablation in those patients during long-term follow-up using continuous atrial rhythm monitoring (CARM). METHODS AND RESULTS: A total of 190 patients (71.3 ± 10.7 years; 108 (56.8% men) were included in this study. At index procedure 81 (42.6%) patients presented with paroxysmal AF and 109 (57.4%) with persistent AF. The ablation strategy included pulmonary vein isolation in all patients and biatrial ablation of complex fractionated electrograms with additional ablation lines, if appropriate. AF recurrences were assessed by CARM- and CIED-related complications by device follow-up. After a mean follow-up of 55.4 ± 38.1 months, freedom of AF was found in 86 (61.4%) and clinical success defined as an AF burden less than or equal to 1% in 101 (72.1%) patients. Freedom of AF was reported in 74.6% and 51.9% (P = 0.006) and clinical success in 89.8% and 59.3% (P < 0.001) of patients with paroxysmal and persistent AF, respectively. In 3 of 408 (0.7%) ablation procedures, a TVL malfunction occurred within 90 days after catheter ablation. During long-term follow-up 9 (4.7%) patients showed lead dislodgement, 2 (1.1%) lead fracture, and 2 (1.1%) lead insulation defect not related to the ablation procedure. CONCLUSION: Our findings using CARM demonstrate long-term efficacy and safety of radiofrequency catheter ablation of AF in patients with CIED and TVL.


Asunto(s)
Arritmias Cardíacas/terapia , Fibrilación Atrial/cirugía , Estimulación Cardíaca Artificial , Ablación por Catéter , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Marcapaso Artificial , Venas Pulmonares/cirugía , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Estimulación Cardíaca Artificial/efectos adversos , Ablación por Catéter/efectos adversos , Muerte Súbita Cardíaca/prevención & control , Cardioversión Eléctrica/efectos adversos , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Supervivencia sin Progresión , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
16.
J Cardiovasc Electrophysiol ; 30(9): 1436-1442, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31190440

RESUMEN

AIMS: We sought to assess (1) clinical outcomes of second-generation cryoballoon (CB) ablation for persistent atrial fibrillation (AF), and (2) the association of baseline and procedural covariates with atrial arrhythmia recurrence (AAR) after ablation. METHODS: A total of 135 patients (63 ± 11 years, 96 men [71%]) with persistent AF underwent CB ablation at three experienced electrophysiology centers. Freedom from AAR was estimated with the Kaplan-Meier method. A Cox proportional-hazards model was used to estimate the effects of baseline and procedural covariates on the likelihood of AAR. RESULTS: Freedom from AAR at 6, 12, and 18 months was estimated at 91% (95% confidence interval [CI] 86%-96%), 75% (95% CI, 67%-83%), and 53% (95% CI, 43%-65%), respectively. The presence of an implantable cardiac device (Hazard ratio [HR] 3.09; 95% CI, 1.37-7.00; P = .007), a left atrial (LA) diameter > 50 mm (HR 1.69; 95% CI, 1.02-2.79; P = .043), and absence of antiarrhythmic drug (AAD) therapy before the ablation procedure (HR 3.12; 95% CI, 1.72-5.64; P < .001) were associated with AAR. A trend toward an increased risk of AAR was revealed for women (HR 1.73; 95% CI, 0.96-3.11; P = .069). CONCLUSIONS: CB ablation for persistent AF resulted in freedom from AAR about that reported for RF ablation. The presence of an implantable cardiac device, LA size, and absence of AAD therapy at baseline were associated with the risk of AAR.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Criocirugía/instrumentación , Femenino , Alemania , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
17.
J Cardiovasc Electrophysiol ; 29(4): 537-547, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29377448

RESUMEN

AIMS: To evaluate the incidence of newly diagnosed intracardiac thrombi (ICT) in respect to the mode of OAC in patients undergoing cardioversion (CV). METHODS AND RESULTS: We prospectively assessed transesophageal echocardiography (TEE) and OAC therapy prior to CV in AF patients with ≥48-hour duration scheduled for CV. A total of 60 first-time ICT (4.7%) were diagnosed in 1,286 TEE, with highest rate in patients without OAC (9.6% vs. OAC 4.1%, P  =  0.009) and an apparently lower rate in nonvitamin K antagonist anticoagulants (NOAC) therapy compared to vitamin K antagonist (VKA) (2.5% vs. 5.3%, P  =  0.02). VKA therapy control 4 weeks prior to CV was overall average (time in therapeutic range 60%) and patients showed more frequently clinical characteristics and TEE parameters associated with risk for ICT. Even among patients with effective OAC therapy (uninterrupted NOAC and VKA therapy with international normalized ratio (INR) ≥2.0 for 3 weeks), ICT occurred in 2.7%, but with no difference between both groups (P  =  0.22). There was no difference between different types of NOAC. Independent predictors for ICT were history of embolism, hypertension, BMI, absence of OAC, renal function, reduced atrial appendage flow, and presence of spontaneous echo contrast. CONCLUSION: NOAC therapy seems favorable in the overall prevention of ICT, although this is likely to be caused by suboptimal VKA therapy control and differences in the overall health status between VKA and NOAC patients. ICT occurred even with effective OAC therapy suggesting individual TEE-guided cardioversion in patients at risk.


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/terapia , Trombosis/prevención & control , Administración Oral , Anciano , Anticoagulantes/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Ecocardiografía Doppler de Pulso , Ecocardiografía Transesofágica , Cardioversión Eléctrica , Electrocardiografía , Femenino , Estado de Salud , Humanos , Incidencia , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Factores de Tiempo , Resultado del Tratamiento
18.
Eur Heart J ; 43(37): 3508-3509, 2022 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-35962627
19.
Pacing Clin Electrophysiol ; 40(12): 1486-1488, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28543085

RESUMEN

We present a case of a patient with a baroreflex activation therapy (BAT) receiving a subcutaneous implantable cardioverter defibrillator (S-ICD). We anticipated two possible hazardous interactions between the two devices. Stimulation by the BAT could be adjudicated as noise and result in underdetection of ventricular arrhythmias or it might be misinterpreted as ventricular arrhythmias and lead to inappropriate shocks. Postop ensing occurred, the upper limit of pulse width of the BAT was limited because of noise detection by the S-ICD, but the upper limit of amplitude was limited by patient's discomfort. In this patient, the combination of a BAT and an S-ICD was safe.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Neuroestimuladores Implantables , Presorreceptores , Adulto , Desfibriladores Implantables/efectos adversos , Diseño de Equipo , Estudios de Factibilidad , Humanos , Masculino
20.
Pacing Clin Electrophysiol ; 40(2): 175-182, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27995637

RESUMEN

BACKGROUND: Extensive and repeated substrate modification (SM) is frequently performed as an ablation strategy in persistent atrial fibrillation (persAF). The effect of these extended ablation strategies on atrial function has not been investigated sufficiently so far. The purpose was to assess atrial function by cardiac magnetic resonance (CMR) and its association with left atrial (LA) scar burden by electroanatomical voltage-mapping after multiple persAF ablation procedures. METHODS: We included 16 persAF patients who had ≥2 SM procedures and a control group (CG) of 21 persAF patients without prior ablation. CMR was performed in sinus rhythm at least 4 weeks after the last cardioversion. Active left and right (RA) atrial emptying fractions (AEF) as well as peak active left atrial appendage (LAA) emptying velocities were obtained by CMR flow measurements. Furthermore, LA scar burden was quantified on electroanatomical voltage maps by the portion of points with local voltage amplitude <0.2 mV. RESULTS: We found median LA-AEF to be lower (13 [9-22] vs 32 [26-36] %, P < 0.001) and median LA scar burden to be higher (40 [20-68] vs nine [3-18] %, P < 0.05) in the SM group compared with the CG. Furthermore, a significant correlation was found between mean LA voltage and LA-AEF (r2 = 0.62, P < 0.001). No significant differences were detected with respect to median RA-AEF (41 [28-48] vs 47 [35-50] %, P = 0.43) and median peak LAA emptying velocities (30 [16-40] vs 17 [13-28] cm/s, P = 0.07). CONCLUSIONS: Active LA function is preserved but significantly impaired and associated with ablation-related LA scar burden after multiple extensive persAF ablations.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Función Atrial , Remodelación Atrial , Ablación por Catéter/efectos adversos , Cicatriz/etiología , Anciano , Fibrilación Atrial/diagnóstico , Enfermedad Crónica , Cicatriz/patología , Cicatriz/fisiopatología , Femenino , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Reoperación/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA