Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
AIDS ; 4(8): 803-6, 1990 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-2261135

RESUMEN

A serum panel comprising 19 samples of known (five positives and 14 negatives) but undisclosed HIV-1-antibody content was distributed to 30 national reference laboratories for HIV serology. In order to simulate normal circumstances of referral, participants were asked to test the panel for HIV-1-antibody status using their normal procedures. Results of testing were returned by 28 participants. There were great variations in the number and combinations of tests used. The number used ranged from one to five assays per laboratory and none of the 24 laboratories using two or more tests employed the same combination. A high average success rate of 99% was seen with the positive samples. More errors occurred with the negative samples, with an average of 87% correct negative reports. Only four of the 14 negative specimens were reported as negative by all participants.


Asunto(s)
Síndrome de Inmunodeficiencia Adquirida/diagnóstico , Técnicas para Inmunoenzimas/normas , Organización Mundial de la Salud , África , Asia , Ensayo de Inmunoadsorción Enzimática/normas , Anticuerpos Anti-VIH/análisis , VIH-1/inmunología , Humanos , Control de Calidad , Derivación y Consulta
2.
J Clin Pathol ; 34(12): 1396-9, 1981 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-7328187

RESUMEN

A further modification of the standard RPHA technique (Hepatest, Wellcome Reagents) for the detection of HBsAg is described. This modification does not require a centrifugation step which is required by the other modifications that have been described previously and consequently takes a little longer to perform. It does, however, retain the advantages of increased sensitivity and decreased costs which are also features of the other modifications. A series of 939 routine clinical specimens were used to evaluate the method described and to evaluate a new RIA kit for the detection of HBsAg (Hepatube, Wellcome Reagents). Of 53 specimens found to be positive for HBsAg by RIA, 50 (94% were detected by the modified Hepatest RPHA as opposed to 47 (89%) by the standard technique.


Asunto(s)
Pruebas de Aglutinación/métodos , Antígenos de Superficie de la Hepatitis B/análisis , Radioinmunoensayo/métodos , Humanos , Juego de Reactivos para Diagnóstico
3.
J Clin Pathol ; 36(10): 1111-5, 1983 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-6311877

RESUMEN

The results of a field trial of a joint DMRQC/Organon ELISA kit for the detection of hepatitis A IgM antibody are reported. The participating laboratories were asked to use the kit to test a panel of 360 specimens consisting of duplicate coded samples of 180 sera. The panel was also tested by MACRIA in the Virus Reference Laboratory, Colindale. The ELISA was shown to be specific and sensitive giving good discrimination between acute and late convalescent hepatitis A sera. It was proposed that the same cut-off control as is used in the RIA (equivalent to 10 RIA units) should be adopted for the ELISA also.


Asunto(s)
Anticuerpos Antivirales/análisis , Ensayo de Inmunoadsorción Enzimática , Hepatovirus/inmunología , Técnicas para Inmunoenzimas , Inmunoglobulina M/análisis , Juego de Reactivos para Diagnóstico , Enfermedad Aguda , Estudios de Evaluación como Asunto , Hepatitis A/diagnóstico , Humanos , Radioinmunoensayo
4.
J Clin Pathol ; 36(5): 581-5, 1983 May.
Artículo en Inglés | MEDLINE | ID: mdl-6841649

RESUMEN

A field trial of an enzyme-linked immunosorbent assay (ELISA) for the detection of the hepatitis Be markers is reported. It is simple to perform, is designed to be read by eye and does not require any expensive apparatus. When compared with a commercially available RIA kit for the detection of the same markers, ELISA was shown to be as sensitive as RIA for the detection of anti-HBe but slightly less sensitive for the detection of HBeAg. However if all specimens negative for both HBeAg and anti-HBe by ELISA are considered to be potentially infectious, the ELISA should prove to be as useful as RIA for determining the "e" status of HBsAg-positive patients and, therefore, provide a reliable indication of the risk of secondary spread of hepatitis B infection to contacts by needle stick accident, close personal contact or perinatal transmission.


Asunto(s)
Anticuerpos Antivirales/análisis , Anticuerpos contra la Hepatitis B/análisis , Antígenos de la Hepatitis B/análisis , Antígenos e de la Hepatitis B/análisis , Ensayo de Inmunoadsorción Enzimática , Antígenos e de la Hepatitis B/inmunología , Radioinmunoensayo
5.
Trans R Soc Trop Med Hyg ; 74(3): 389-92, 1980.
Artículo en Inglés | MEDLINE | ID: mdl-6254219

RESUMEN

Of 33 patients with acute hepatitis in Malawi, 21 had infection by hepatitis-B virus (HBV), five by hepatitis-A virus (HAV) and seven, who had no markers of current HBV or HAV infections, were probably infected by the agent(s) of non-A, non-B, hepatitis. 87 of 88 sera from persons without liver disease contained antibody to HAV and 49 antibody to hepatitis-B surface antigen (anti-HBs) (six were positive for hepatitis-B surface antigen). The diagnosis of recent infection by HAV was made by detecting HAV-specific IGM in single serum samples and, although such tests showed that HAV caused acute hepatitis, its absence in patients with chronic liver disease suggests that, unlike HBV, infection by HAV does not play a role in chronic liver disease in Malawi. Anti-hepatis-B core antigen (anti-HBc)-specific IgM was detected in 19 of 21 patients with acute HBV infection, in three of five HbsAg-positive patients with cirrhosis, but in none of five HbsAg-positive patients with hepatoma.


Asunto(s)
Hepatitis C/inmunología , Hepatitis Viral Humana/inmunología , Inmunoglobulina M/análisis , Hepatopatías/inmunología , Adolescente , Adulto , Especificidad de Anticuerpos , Carcinoma Hepatocelular/inmunología , Femenino , Antígenos del Núcleo de la Hepatitis B/inmunología , Antígenos de Superficie de la Hepatitis B/análisis , Virus de la Hepatitis B/inmunología , Hepatitis Viral Humana/microbiología , Hepatovirus/inmunología , Humanos , Cirrosis Hepática/inmunología , Hepatopatías/microbiología , Neoplasias Hepáticas/inmunología , Malaui , Masculino , Persona de Mediana Edad
7.
Bull World Health Organ ; 70(5): 605-13, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1464146

RESUMEN

The WHO international quality assessment scheme for human immunodeficiency virus (HIV) antibody testing has been established to monitor the quality of laboratory performance in testing for antibodies to HIV. Following a small trial distribution of specimens early in 1989, the second distribution was made in February 1990. A total of 20 specimens of sera, 10 of which contained antibodies to HIV-1, were sent to 103 laboratories located in the six WHO Regions. Participants were asked to test the specimens using their routine methods and to report to WHO their findings on each specimen for each diagnostic assay used and their interpretation of the HIV antibody status of each specimen. For the antibody-positive specimens, 98.2% of the results were interpreted as positive and 1.8% as indeterminate; no false-negative interpretations were reported. For the antibody-negative specimens, 90.3% of the results were interpreted as negative, 1.3% as positive, and 8.4% as indeterminate. Most of the indeterminate reports were associated with one particular specimen. A wide variety of diagnostic assays and combinations of assays were used. In terms of the technical results obtained rather than their interpretation, the assays appeared extremely reliable for the positive specimens, with 99.5% of assay results being recorded as positive, 0.17% as negative, and 0.34% as indeterminate.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Serodiagnóstico del SIDA/normas , VIH-1/inmunología , Western Blotting , Reacciones Falso Positivas , Humanos , Técnicas Inmunológicas , Control de Calidad , Reproducibilidad de los Resultados , Organización Mundial de la Salud
8.
Histopathology ; 5(6): 623-37, 1981 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-7319481

RESUMEN

In a survey of the prevalence of chronic hepatitis B in a male homosexual population, liver biopsies were done in 28 asymptomatic patients who had persistently raised aminotransferases. Four patients had active cirrhosis (AC), 13 had chronic active hepatitis (CAH) of various degrees of severity and 11 had either chronic persistent hepatitis (CPH) or minor changes of the type seen in hepatitis B virus carriers. Core associated antigens and surface antigen, were demonstrated by the PAP immunoperoxidase method in 20 cases. Core and surface antigens tended to be present in the same areas of the biopsy and quantitation showed higher core to surface antigen ratios in CAH than in CPH, the difference being statistically significant. In seven cases no core-associated antigens were demonstrated in the presence of surface antigen: most of these patients had either inactive disease or active cirrhosis. In one carrier neither antigen was demonstrated. Ten patients had two or more biopsies. Four of these had no treatment and the amounts of core and surface positive cells in the liver did not increase. Six were treated with immunosuppressants. This did not alter the degree of either inflammation or fibrosis. but the number of surface and core antigen positive cells in the liver was higher after treatment in almost every case.


Asunto(s)
Antígenos del Núcleo de la Hepatitis B/análisis , Antígenos de Superficie de la Hepatitis B/análisis , Hepatitis B/inmunología , Homosexualidad , Hígado/inmunología , Azatioprina/uso terapéutico , Hepatitis B/tratamiento farmacológico , Hepatitis B/patología , Humanos , Hígado/patología , Cirrosis Hepática/tratamiento farmacológico , Masculino , Prednisona/uso terapéutico
9.
Bull World Health Organ ; 66(2): 197-202, 1988.
Artículo en Inglés | MEDLINE | ID: mdl-3260829

RESUMEN

PIP: 21 laboratories participated in an international collaborative study to evaluate potential international reference reagents for measurement of antibodies to human immunodeficiency virus (HIV). Given inherent differences between the principles of currently used assays (based on enzyme-linked or radioimmunosorbance, immunofluorescence, immunoblotting, or immunoprecipitation) and batch-to-batch variations in the preparations of reagents and kits, there is an urgent need for well-characterized reference materials that can be used to define the reliability and sensitivity of the tests, for quality control of batches, and as common references between laboratories. The 7 human sera tested included 1 reactive against HIV and 1 unreactive. The study was designed to identify the coded preparations that reacted with HIV antibodies and to ascertain the minimum amount of the reactive samples that could be detected in the methods routinely used by the participants. Participants carried out single or duplicate assays for individual manufacturer's ELISAs or by their local methods. The proposed positive international reference reagent (coded A) reacted strongly in all immunoassays and gave all the expected bands in immunoblot systems using HIV-related virus strains as antigens. The unreactive serum (coded E) was negative by ELISA and immunoblots. Although the end-points determined by ELISAs varied considerably between laboratories, even when the same commercial kit was used, this variation was reduced somewhat when the reactivities of the samples were expressed relative to preparation A. It is concluded that the proposed international reference reagent A may have value as a qualitative check on the specificity of assays, in calibrating positive controls included in kits and other assays in arbitrary units, in calibrating detection limits in arbitrary units, and for calibrating immunoblots, especially for defining the optimal amounts of antigen and determining the relative mobilities of the major HIV peptides and glycopeptides.^ieng


Asunto(s)
Anticuerpos Antivirales/análisis , VIH/inmunología , Ensayo de Inmunoadsorción Enzimática , Anticuerpos Anti-VIH , Humanos , Inmunoensayo/métodos , Cooperación Internacional , Valores de Referencia , Organización Mundial de la Salud
13.
Bol. Oficina Sanit. Panam ; 105(5/6): 753-762, nov.-dic. 1988. ilus
Artículo en Español | LILACS | ID: lil-367111

RESUMEN

Two preparations of human sera, one reactive against human immunodeficiency virus (HIV) and the other unreactive, were evaluated as potential international reference reagents (IRR) in an international collaborative study. Twenty-one laboratories participated and tested these and five other human sera which were found to range from highly reactive to unreactive. The proposed "positive" IRR was found to react strongly in all immunoassays and gave all the expected bands in immunoblot systems using HTLV-III, LAV-I or similar virus strains as antigens. The "unreactive" serum was judged to be negative by ELISA and immunoblots. The end-points determined by ELISAs varied considerably between laboratories, even between those using the same commercial kit. This variation was reduced somewhat when the reactivities of the samples were expressed relative to the proposed IRR


Asunto(s)
Anticuerpos Antivirales/análisis , Ensayo de Inmunoadsorción Enzimática , VIH , Cooperación Internacional , Inmunoensayo/métodos , Valores de Referencia , Organización Mundial de la Salud
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA