Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Clin Gastroenterol Hepatol ; 6(10): 1122-8, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18928937

RESUMEN

BACKGROUND & AIMS: Annual testing for fecal occult blood is recommended as first-line screening for the detection of colorectal cancer (CRC), but is affected by limited sensitivity. We initiated a proteomics-based search for novel biomarkers to improve the sensitivity of detection of CRC in stool samples. METHODS: Six markers, including immunologic fecal occult blood test (iFOBT), were evaluated in a collective of 551 samples (186 CRC, 113 advanced adenoma, and 252 control patients) to establish the diagnostic performance of each marker and marker combinations. RESULTS: We tested the known stool markers hemoglobin (iFOBT), hemoglobin-haptoglobin, calprotectin, carcinoembryogenic antigen, and the novel fecal markers tissue inhibitor of metalloproteinase-1 (TIMP-1) and S100A12. The best diagnostic performance was found for S100A12 with an area under the curve of 0.95, followed by TIMP-1 (0.92), hemoglobin-haptoglobin (0.92), hemoglobin (0.91), calprotectin (0.90), and carcinoembryogenic antigen (0.66). By using Bayes logistic regression as a mathematic model, the highest sensitivity (88%) for the detection of CRC at 95% specificity was obtained with the marker pair S100A12 and hemoglobin-haptoglobin. Increasing the specificity to 98%, the combination of S100A12, hemoglobin-haptoglobin, and TIMP-1 resulted in a sensitivity of 82%, with the highest increase of sensitivity found in early tumor stages (international union against cancer stage I: 74% sensitivity vs 57% of the best single marker). CONCLUSIONS: Depending on the specificity selected, a marker pair, S100A12 and hemoglobin-haptoglobin, or a triple combination including TIMP-1, allowed the detection of CRC at significantly higher rates than can be obtained with iFOBT alone.


Asunto(s)
Biomarcadores de Tumor/análisis , Neoplasias Colorrectales/diagnóstico , Heces/química , Sangre Oculta , Proteínas/análisis , Antígeno Carcinoembrionario/análisis , Haptoglobinas/análisis , Hemoglobinas/análisis , Humanos , Complejo de Antígeno L1 de Leucocito/análisis , Proteínas S100/análisis , Proteína S100A12 , Sensibilidad y Especificidad , Inhibidor Tisular de Metaloproteinasa-1/análisis
2.
Clin Cancer Res ; 11(18): 6550-7, 2005 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-16166432

RESUMEN

PURPOSE: The goal of this study was to identify and validate novel serum markers of human colorectal cancer as potential candidates for noninvasive detection of early colorectal neoplasm. EXPERIMENTAL DESIGN: Employing two-dimensional gel electrophoresis and mass spectrometry, we analyzed 16 matched colorectal cancer and adjacent normal tissue samples. Proteins found to be elevated in cancer tissue were further validated by generating antibodies which were used for immunoblotting of tissue samples and for the development of highly sensitive immunoassays for assessment of serum samples. RESULTS: In total, 735 different proteins were identified in colon tissue. Strong elevation in colorectal cancer for five proteins was confirmed by immunoblot analysis: transforming growth factor-beta induced protein ig-h3 (betaIG-H3), nicotinamide N-methyltransferase (NNMT), nucleoside diphosphate kinase A (nm23-H1), purine nucleoside phosphorylase (PNPH), and mannose-6-phosphate receptor binding protein 1 (M6P1). Elevated levels of NNMT, which is not predicted to be secreted but is known as a cytoplasmic protein, were found in serum from patients with colorectal cancer. Employing a receiver-operating characteristic curve based on the measurement of 109 patients with colorectal cancer and 317 healthy controls, we obtained an area under the curve of 0.84 for NNMT, which was superior to the established tumor marker carcinoembryogenic antigen with an area under the curve of 0.78. CONCLUSIONS: It is proposed that NNMT serum levels may have significance in the early detection and in the management of patients with colorectal cancer.


Asunto(s)
Biomarcadores de Tumor/sangre , Neoplasias Colorrectales/sangre , Metiltransferasas/sangre , Anciano , Anciano de 80 o más Años , Proteínas Sanguíneas/análisis , Neoplasias Colorrectales/diagnóstico , Electroforesis en Gel Bidimensional , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nicotinamida N-Metiltransferasa , Proteoma/análisis , Sensibilidad y Especificidad
3.
J Clin Virol ; 34(1): 42-7, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16087123

RESUMEN

BACKGROUND: Until the mandatory introduction of viral inactivation techniques of blood plasma products in the early 1980s many recipients of these products were infected with various viral pathogens. OBJECTIVES: To determine the rate of transmission of GB virus C/hepatitis G virus (GBV-C/HGV) HCV, and HIV through non-virus-inactivated clotting factor concentrates in hemophiliacs, as well as the relation between amount of administered clotting factor and risk for GBV-C/HGV infection. STUDY DESIGN: In this cross-sectional study, we determined retrospectively the rates of infection markers for GBV-C/HGV, HCV, and HIV in a German cohort of hemophiliacs treated with documented amounts of non-virus-inactivated clotting factor concentrates (group A) and in a second group of hemophiliacs who were treated exclusively with virus-inactivated clotting factor (group B). The presence of anti-virus antibodies was determined by ELISA. Viral RNA was detected by RT-PCR. Markers for viral infections were compared to amounts of administered non-virus-inactivated clotting factor. RESULTS: Among hemophiliacs treated with documented amounts of non-virus-inactivated clotting factor the prevalence for GBV-C/HGV, HCV, and HIV was 40.3%, 98.6%, and 56.3%, respectively. In contrast to HIV, the rate of GBV-C/HGV infections did not increase with increasing amounts of consumed non-inactivated clotting factor. Even in the subgroup of heavily treated hemophiliacs the rate of GBV-C/HGV infection markers did not exceed 45%. CONCLUSIONS: The amount of non-virus-inactivated clotting factor is not predictive for the risk of GBV-C/HGV infection in hemophiliacs. Despite repeated parenteral exposure more than 55% of hemophiliacs were not infected with GBV-C/HGV. Our findings indicate a high frequency of host factors preventing parenteral transmission of GBV-C/HGV.


Asunto(s)
Infecciones por Flaviviridae/transmisión , Virus GB-C , Infecciones por VIH/transmisión , VIH , Hemofilia A/virología , Hepacivirus , Hepatitis C/transmisión , ARN Viral/sangre , Carga Viral , Anticuerpos Antivirales/sangre , Secuencia de Bases , Estudios Transversales , Cartilla de ADN , Hemofilia A/sangre , Humanos , Reacción en Cadena de la Polimerasa , ARN Viral/aislamiento & purificación , Estudios Retrospectivos
4.
Chem Biol ; 21(3): 357-68, 2014 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-24529991

RESUMEN

Investigation of protein-protein interactions (PPIs) and protein phosphorylation in clinical tissue samples can offer valuable information about the activation status and function of proteins involved in disease progression. However, existing antibody-based methods for phosphorylation detection have been found to lack specificity, and methods developed for examining PPIs in vitro cannot be easily adapted for tissues samples. In this study, we eliminated some of these limitations by developing a specific immunohistochemical staining method that uses "dual binders" (DBs), which are bispecific detection agents consisting of two Fab fragment molecules joined by a flexible linker, to detect PPIs and protein phosphorylation. We engineered DBs by selecting Fab fragments with fast off-rate kinetics, which allowed us to demonstrate that stable target binding was achieved only upon simultaneous, cooperative binding to both epitopes. We show that DBs specifically detect the activated HER2/HER3 complex in formalin-fixed, paraffin-embedded cancer cells and exhibit superior detection specificity for phospho-HER3 compared to the corresponding monoclonal antibody. Overall, the performance of DBs makes them attractive tools for future development for clinical applications.


Asunto(s)
Inmunohistoquímica , Proteínas/metabolismo , Receptor ErbB-2/análisis , Receptor ErbB-3/análisis , Animales , Anticuerpos/química , Anticuerpos/inmunología , Línea Celular Tumoral , Dimerización , Células HEK293 , Humanos , Fragmentos Fab de Inmunoglobulinas/química , Fragmentos Fab de Inmunoglobulinas/genética , Fragmentos Fab de Inmunoglobulinas/metabolismo , Células MCF-7 , Ratones , Oligonucleótidos/síntesis química , Oligonucleótidos/química , Fosforilación , Dominios y Motivos de Interacción de Proteínas , Receptor ErbB-2/genética , Receptor ErbB-2/metabolismo , Receptor ErbB-3/genética , Receptor ErbB-3/metabolismo , Proteínas Recombinantes/biosíntesis , Proteínas Recombinantes/química , Proteínas Recombinantes/genética
5.
Clin Cancer Res ; 16(24): 6111-21, 2010 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-20798228

RESUMEN

PURPOSE: Fecal occult blood testing is recommended as first-line screening to detect colorectal cancer (CRC). We evaluated markers and marker combinations in serum as an alternative to improve the detection of CRC. EXPERIMENTAL DESIGN: Using penalized logistic regression, 6 markers were selected for evaluation in 1,027 samples (301 CRC patients, 143 patients with adenoma, 266 controls, 141 disease controls, and 176 patients with other cancer). The diagnostic performance of each marker and of marker combinations was assessed. RESULTS: To detect CRC from serum samples, we tested 22 biomarkers. Six markers were selected for a marker combination, including the known tumor markers CEA (carcinoembryonic antigen) and CYFRA 21-1 as well as novel markers or markers that are less routinely used for the detection of CRC: ferritin, osteopontin (OPN), anti-p53, and seprase. CEA showed the best sensitivity at 95% specificity with 43.9%, followed by seprase (42.4%), CYFRA 21-1 (35.5%), OPN (30.2%), ferritin (23.9%), and anti-p53 (20.0%). A combination of these markers gave 69.6% sensitivity at 95% specificity and 58.7% at 98% specificity. Focusing on International Union against Cancer (UICC) stages 0-III reduced the sensitivity slightly to 68.0% and 53.3%, respectively. In a subcollective, with matched stool samples (75 CRC cases and 234 controls), the sensitivity of the marker combination was comparable with fecal immunochemical testing (FIT) with 82.4% and 68.9% versus 81.8% and 72.7% at 95% and 98% specificity, respectively. CONCLUSIONS: The performance of the serum marker combination is comparable with FIT. This provides a novel tool for CRC screening to trigger a follow-up colonoscopy for a final diagnosis.


Asunto(s)
Adenoma/diagnóstico , Biomarcadores de Tumor/sangre , Neoplasias Colorrectales/diagnóstico , Detección Precoz del Cáncer/métodos , Adenoma/sangre , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores de Tumor/análisis , Estudios de Casos y Controles , Neoplasias Colorrectales/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sangre Oculta , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Adulto Joven
6.
Mol Cell Proteomics ; 5(11): 2092-101, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16893879

RESUMEN

The purpose of this study was to identify and validate novel serological protein biomarkers of human colorectal cancer (CRC). Proteins from matched CRC and adjacent normal tissue samples were resolved by two-dimensional gel electrophoresis. From each gel all spots were excised, and enveloped proteins were identified by MS. By comparison of the resulting protein profiles, dysregulated proteins can be identified. A list of all identified proteins and validation of five exemplarily selected proteins, elevated in CRC was reported previously (Roessler, M., Rollinger, W., Palme, S., Hagmann, M. L., Berndt, P., Engel, A. M., Schneidinger, B., Pfeffer, M., Andres, H., Karl, J., Bodenmuller, H., Ruschoff, J., Henkel, T., Rohr, G., Rossol, S., Rosch, W., Langen, H., Zolg, W., and Tacke, M. (2005) Identification of nicotinamide N-methyltransferase as a novel serum tumor marker for colorectal cancer. Clin. Cancer Res. 11, 6550-6557). Here we describe identification and initial validation of another potential marker protein for CRC. Comparison of tissue protein profiles revealed strong elevation of proteasome activator complex subunit 3 (PSME3) expression in CRC tissue. This dysregulation was not detectable based on the spot pattern. The PSME3-containing spot on tumor gels showed no visible difference to the corresponding spot on matched control gels. MS analysis revealed the presence of two proteins, PSME3 and annexin 4 (ANXA4) in one and the same spot on tumor gels, whereas the matched spot contained only one protein, ANXA4, on control gels. Therefore, dysregulation of PSME3 was masked by ANXA4 and could only be recognized by MS-based analysis but not by image analysis. To validate this finding, antibody to PSME3 was developed, and up-regulation in CRC was confirmed by Western blot analysis and immunohistochemistry. Finally by developing a highly sensitive immunoassay, PSME3 could be detected in human sera and was significantly elevated in CRC patients compared with healthy donors and patients with benign bowel disease. We propose that PSME3 be considered a novel serum tumor marker for CRC that may have significance in the detection and in the management of patients with this disease. Further studies are needed to fully assess the potential clinical value of this marker candidate.


Asunto(s)
Autoantígenos/sangre , Biomarcadores de Tumor/sangre , Neoplasias Colorrectales/diagnóstico , Electroforesis en Gel Bidimensional , Espectrometría de Masas/métodos , Complejo de la Endopetidasa Proteasomal/sangre , Secuencia de Aminoácidos , Autoantígenos/análisis , Biomarcadores de Tumor/análisis , Neoplasias Colorrectales/química , Humanos , Inmunohistoquímica , Datos de Secuencia Molecular , Complejo de la Endopetidasa Proteasomal/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA