Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
NMR Biomed ; : e5210, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38993021

RESUMEN

The aim of the current study is to demonstrate the feasibility of radiofrequency (RF) pulses generated via an optimal control (OC) algorithm to perform magnetic resonance elastography (MRE) and quantify the mechanical properties of materials with very short transverse relaxation times (T2 < 5 ms) for the first time. OC theory applied to MRE provides RF pulses that bring isochromats from the equilibrium state to a fixed target state, which corresponds to the phase pattern of a conventional MRE acquisition. Such RF pulses applied with a constant gradient allow to simultaneously perform slice selection and motion encoding in the slice direction. Unlike conventional MRE, no additional motion-encoding gradients (MEGs) are needed, enabling shorter echo times. OC pulses were implemented both in turbo spin echo (OC rapid acquisition with refocused echoes [RARE]) and ultrashort echo time (OC UTE) sequences to compare their motion-encoding efficiency with the conventional MEG encoding (classical MEG MRE). MRE experiments were carried out on agar phantoms with very short T2 values and on an ex vivo bovine tendon. Magnitude images, wave field images, phase-to-noise ratio (PNR), and shear storage modulus maps were compared between OC RARE, OC UTE, and classical MEG MRE in samples with different T2 values. Shear storage modulus values of the agar phantoms were in agreement with values found in the literature, and that of the bovine tendon was corroborated with rheometry measurements. Only the OC sequences could encode motion in very short T2 samples, and only OC UTE sequences yielded magnitude images enabling proper visualization of short T2 samples and tissues. The OC UTE sequence produced the best PNRs, demonstrating its ability to perform anatomical and mechanical characterization. Its success warrants in vivo confirmation in further studies.

2.
NMR Biomed ; 34(2): e4442, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33179393

RESUMEN

Magnetic resonance elastography (MRE) is used to non-invasively quantify viscoelastic properties of tissues based on the measurement of propagation characteristics of shear waves. Because some of these viscoelastic parameters show a frequency dependence, multifrequency analysis allows us to measure the wave propagation dispersion, leading to a better characterization of tissue properties. Conventionally, motion encoding gradients (MEGs) oscillating at the same frequency as the mechanical excitation encode motion. Hence, multifrequency data is usually obtained by sequentially repeating monochromatic wave excitations experiments at different frequencies. The result is that the total acquisition time is multiplied by a factor corresponding to the number of repetitions of monofrequency experiments, which is a major limitation of multifrequency MRE. In order to make it more accessible, a novel single-shot harmonic wideband dual-frequency MRE method is proposed. Two superposed shear waves of different frequencies are simultaneously generated and propagate in a sample. Trapezoidal oscillating MEGs are used to encode mechanical vibrations having frequencies that are an odd multiple of the MEG frequency. The number of phase offsets is optimized to reduce the acquisition time. For this purpose, a sampling method not respecting the Shannon theorem is used to produce a controlled temporal aliasing that allows us to encode both frequencies without any additional examination time. Phantom experiments were run to compare conventional monofrequency MRE with the single-shot dual-frequency MRE method and showed excellent agreement between the reconstructed shear storage moduli G'. In addition, dual-frequency MRE yielded an increased signal-to-noise ratio compared with conventional monofrequency MRE acquisitions when encoding the high frequency component. The novel proposed multifrequency MRE method could be applied to simultaneously acquire more than two frequency components, reducing examination time. Further studies are needed to confirm its applicability in preclinical and clinical models.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Imagen por Resonancia Magnética/métodos , Elasticidad , Humanos , Procesamiento de Imagen Asistido por Computador , Movimiento (Física) , Fantasmas de Imagen , Relación Señal-Ruido , Viscosidad
3.
Magn Reson Med ; 81(1): 424-438, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30265759

RESUMEN

PURPOSE: This article proposes a rigorous optimal control framework for the design of preparation schemes that optimize MRI contrast based on relaxation time differences. METHODS: Compared to previous optimal contrast preparation schemes, a drastic reduction of the optimization parameter number is performed. The preparation scheme is defined as a combination of several block pulses whose flip angles, phase terms and inter-pulse delays are optimized to control the magnetization evolution. RESULTS: The proposed approach reduces the computation time of B 0 -robust preparation schemes to around a minute (whereas several hours were required with previous schemes), with negligible performance loss. The chosen parameterization allows to formulate the total preparation duration as a constraint, which improves the overall compromise between contrast performance and preparation time. Simulation, in vitro and in vivo results validate this improvement, illustrate the straightforward applicability of the proposed approach, and point out its flexibility in terms of achievable contrasts. Major improvement is especially achieved for short-T2 enhancement, as shown by the acquisition of a non-trivial contrast on a rat brain, where a short-T2 white matter structure (corpus callosum) is enhanced compared to surrounding gray matter tissues (hippocampus and neocortex). CONCLUSIONS: This approach proposes key advances for the design of optimal contrast preparation sequences, that emphasize their ability to generate non-standard contrasts, their potential benefit in a clinical context, and their straightforward applicability on any MR system.


Asunto(s)
Encéfalo/diagnóstico por imagen , Medios de Contraste/farmacología , Imagen por Resonancia Magnética , Envejecimiento , Algoritmos , Enfermedad de Alzheimer/diagnóstico por imagen , Animales , Simulación por Computador , Cuerpo Calloso/diagnóstico por imagen , Femenino , Sustancia Gris/diagnóstico por imagen , Hipocampo/diagnóstico por imagen , Humanos , Magnetismo , Modelos Teóricos , Esclerosis Múltiple/diagnóstico por imagen , Fantasmas de Imagen , Ratas , Tálamo/diagnóstico por imagen
4.
Comput Biol Med ; 178: 108753, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38897148

RESUMEN

The Instantaneous Signal Loss Simulation (InSiL) model is a promising alternative to the classical mono-exponential fitting of the Modified Look-Locker Inversion-recovery (MOLLI) sequence in cardiac T1 mapping applications, which achieves better accuracy and is less sensitive to heart rate (HR) variations. Classical non-linear least squares (NLLS) estimation methods require some parameters of the model to be fixed a priori in order to give reliable T1 estimations and avoid outliers. This introduces further bias in the estimation, reducing the advantages provided by the InSiL model. In this paper, a novel Bayesian estimation method using a hierarchical model is proposed to fit the parameters of the InSiL model. The hierarchical Bayesian modeling has a shrinkage effect that works as a regularizer for the estimated values, by pulling spurious estimated values toward the group-mean, hence reducing greatly the number of outliers. Simulations, physical phantoms, and in-vivo human cardiac data have been used to show that this approach estimates accurately all the InSiL parameters, and achieve high precision estimation of the T1 compared to the classical MOLLI model and NLLS InSiL estimation.

5.
Sci Rep ; 12(1): 1406, 2022 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-35082303

RESUMEN

Magnetic Resonance Elastography (MRE) quantifies the mechanical properties of tissues, typically applying motion encoding gradients (MEG). Multifrequency results allow better characterizations of tissues using data usually acquired through sequential monofrequency experiments. High frequencies are difficult to reach due to slew rate limitations and low frequencies induce long TEs, yielding magnitude images with low SNR. We propose a novel strategy to perform simultaneous multifrequency MRE in the absence of MEGs: using RF pulses designed via the Optimal Control (OC) theory. Such pulses control the spatial distribution of the MRI magnetization phase so that the resulting transverse magnetization reproduces the phase pattern of an MRE acquisition. The pulse is applied with a constant gradient during the multifrequency mechanical excitation to simultaneously achieve slice selection and motion encoding. The phase offset sampling strategy can be adapted according to the excitation frequencies to reduce the acquisition time. Phantom experiments were run to compare the classical monofrequency MRE to the OC based dual-frequency MRE method and showed excellent agreement between the reconstructed shear storage modulus G'. Our method could be applied to simultaneously acquire low and high frequency components, which are difficult to encode with the classical MEG MRE strategy.

6.
Quant Imaging Med Surg ; 11(8): 3431-3447, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34341721

RESUMEN

BACKGROUND: Non-human primate (NHP) could be an interesting model for osteoarthritis (OA) longitudinal studies but standard medical imaging protocols are not able to acquire sufficiently high-resolution images to depict the thinner cartilage (compared to human) in an in vivo context. The aim of this study was thus to develop and validate the acquisition protocols for knee joint examination of NHP using magnetic resonance imaging (MRI) at 1.5 T and X-ray micro-computed tomography arthrography (µCTA). METHODS: The first phase of the study focused on developing dedicated in vivo HR-MRI and µCTA protocols for simultaneous acquisitions of both knee joints on NHP. For MR, a dedicated two-channel receiver array coil and acquisition sequence were developed on a 1.5 T Siemens Sonata system and tuned to respect safety issues and reasonable examination time. For µCTA, an experimental setup was devised so as to fulfill similar requirements. The two imaging protocols were used during a longitudinal study so as to confirm that repeated injections of loxaglic acid (contrast agent used for µCTA) didn't induce any bias in cartilage assessment and to compare segmentation results from the two modalities. Lateral and medial cartilage tibial plateaus were assessed using a common image processing protocol leading to a 3D estimation of the cartilage thickness. RESULTS: From HR-MRI and µCTA images, thickness distributions were extracted allowing for proper evaluation of knee cartilage thickness of the primates. Results obtained in vivo indicated that the µCTA protocol did not induce any bias in the measured cartilage parameters and moreover, segmentation results obtained from the two imaging modalities were consistent. CONCLUSIONS: MR and µCTA are valuable imaging tools for the morphological evaluation of cartilage in NHP models which in turn can be used for OA studies.

7.
J Magn Reson ; 294: 153-161, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30053754

RESUMEN

This article presents a new motion encoding strategy to perform magnetic resonance elastography (MRE). Instead of using standard motion encoding gradients, a tailored RF pulse is designed to simultaneously perform selective excitation and motion encoding in presence of a constant gradient. The RF pulse is designed with a numerical optimal control algorithm, in order to obtain a magnetization phase distribution that depends on the displacement characteristics inside each voxel. As a consequence, no post-excitation encoding gradients are required. This offers numerous advantages, such as reducing eddy current artifacts, and relaxing the constraint on the gradients maximum switch rate. It also allows to perform MRE with ultra-short TE acquisition schemes, which limits T2 decay and optimizes signal-to-noise ratio. The pulse design strategy is developed and analytically analyzed to clarify the encoding mechanism. Finally, simulations, phantom and ex vivo experiments show that phase-to-noise ratios are improved when compared to standard MRE encoding strategies.

8.
J Magn Reson ; 281: 82-93, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28558274

RESUMEN

This paper investigates the use of Optimal Control (OC) theory to design Radio-Frequency (RF) pulses that actively control the spatial distribution of the MRI magnetization phase. The RF pulses are generated through the application of the Pontryagin Maximum Principle and optimized so that the resulting transverse magnetization reproduces various non-trivial and spatial phase patterns. Two different phase patterns are defined and the resulting optimal pulses are tested both numerically with the ODIN MRI simulator and experimentally with an agar gel phantom on a 4.7T small-animal MR scanner. Phase images obtained in simulations and experiments are both consistent with the defined phase patterns. A practical application of phase control with OC-designed pulses is also presented, with the generation of RF pulses adapted for a Magnetic Resonance Elastography experiment. This study demonstrates the possibility to use OC-designed RF pulses to encode information in the magnetization phase and could have applications in MRI sequences using phase images.

9.
J Colloid Interface Sci ; 393: 161-73, 2013 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-23201065

RESUMEN

We investigate a non-ionic surfactant (C(12)E(8))/water binary mixture, over a wide range of concentrations and temperatures (i.e. 1-35 wt.% of C(12)E(8) and 10-60 °C in temperature) by means of different experimental techniques: Small-Angle Neutron Scattering (SANS), Quasi Elastic Light Scattering (QELS) and High Frequency Rheology. The aims of this work are to provide information on structure, thermodynamics and dynamics of the isotropic phase of such a micellar system and, by combining these different types of information, to obtain a comprehensive image of the behaviour of this phase. Our results demonstrate that structural, thermodynamic and dynamic properties of these solutions are fully monitored by the temperature-induced changes in the ethylene-glycol chain hydration. They confirm that C(12)E(8) micelles are spherical and do not grow in the investigated range of concentrations and temperatures. They demonstrate that the interaction potential between C(12)E(8) micelles is more complicated than what was previously described, with an additional repulsive interaction. They allow us to put forward explanations for the Isotropic-Ordered phase transition as well as for the temperature behaviour of the viscosity of C(12)E(8) micellar solutions. Our investigation provides new and valuable information on the dynamics of these mixtures that reflect the complexity of the interaction potential between the C(12)E(8) micelles. It shows that concentrated solutions exhibit a viscoelastic behaviour that can be described by a simple Maxwell model.


Asunto(s)
Tensoactivos/química , Termodinámica , Iones/química , Micelas , Estructura Molecular , Reología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA