Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
1.
Niger J Clin Pract ; 23(8): 1178-1181, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32788499

RESUMEN

Restoration of the malaligned dental implants in the esthetic zone is a challenge for dental practitioner because of the difficulty in obtaining balance and harmony between position and color of the final prosthesis and the adjacent teeth. Mesostructure is a part of the prosthesis that located ontop of the dental implant and bearing the final prosthesis. It has a form of milled bar to bear an overdenture or as abutment used for the correction of malaligned dental implants. Such approach maintains screw-retained prosthesis option while allowing complete retrievability, improved accessibility, usage of thicker abutment screws, and acceptable esthetic outcomes. In this case report, a two-piece mesostructure was designed to correct the malposition of dental implants in the esthetic zone with 1-year follow-up system.


Asunto(s)
Tornillos Óseos , Implantes Dentales , Diseño de Prótesis Dental , Estética Dental , Maxilar/cirugía , Anciano , Diseño de Prótesis Dental/métodos , Prótesis Dental de Soporte Implantado , Odontólogos , Prótesis de Recubrimiento , Femenino , Humanos , Rol Profesional , Resultado del Tratamiento
2.
Niger J Clin Pract ; 23(12): 1629-1638, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33355813

RESUMEN

Dentists are often confronted with challenges concerning the determination of the treatment type for questionable teeth (retention or extraction) in their routine dental practice. The objective of this review was to explore the available literature pertaining to the factors influencing clinical decision-making and treatment strategies of dentists regarding tooth retention or extraction. Explorative analysis of the literature was conducted based on its relevance to the subjected study area and scope. Primarily, the papers were extracted from sources such as ERIC, PubMed, Scopus, and Medline. The keywords used for searching articles include Clinical Decision-Making, Treatment Strategies, Tooth Extraction, and Tooth Retention. Papers published up to 2018 were extracted and evaluated. The analyzed studies highlighted that a successful treatment plan is based on the practitioner's knowledge, abilities, and skills as well as patients' preference, which is also a determinant of treatment success in restorative dentistry. Multidisciplinary dental treatment is generally adopted for decision making in dental clinics. Overall, the treatment plan should be based on the extensive learning and keen observation of the disease and the associated factors which enable long-term success of the treatment.


Asunto(s)
Toma de Decisiones Clínicas , Extracción Dental , Toma de Decisiones , Humanos , Prioridad del Paciente , Resultado del Tratamiento
3.
Oper Dent ; 49(1): 84-90, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38058016

RESUMEN

OBJECTIVE: The aim of this investigation was to compare the fracture resistance of chairside computer-aided design and computer-aided manufacturing (CAD/CAM) lithium disilicate-reinforced ceramic occlusal veneers with and without margin and traditional full coverage premolar crowns. METHODS AND MATERIALS: A total of 60 chairside CAD/CAM lithium disilicate-reinforced ceramic (Amber Mill, Hass Bio) restorations were designed and fabricated with a chairside CAD/CAM system (CEREC Dentsply Sirona). The restorations were divided into three groups (n=20): 1) occlusal veneer with 1.0-mm uniform occlusal thickness and with chamfer margin; 2) occlusal veneer with 1.0-mm uniform occlusal thickness and without margin; and 3) full coverage crown with uniform occlusal thickness and gingival margin. Occlusal veneers and crowns were cemented with dual cured resin luting cement (Multilink, Ivoclar Vivadent) to printed resin dies, load cycled (5 million load cycles at 1 Hz with 275 N force), and then loaded until fracture. Load at break (LB) and peak load (PL) until fracture were recorded. Scanning electron microscope images of the tested restorations on the abutments were obtained. RESULTS: Fracture strengths were different depending on the design of the restoration. There was no significant difference in fracture strength between the two types of occlusal veneer (LB: 1132.45 N; PL: 1143.30 N for veneers with margin; LB: 1149.25 N; PL: 1219.05 N for veneers without margin). Full coverage crowns showed the lowest fracture resistance (LB: 936.26 N, PL: 976.42 N), which was significantly lower than both designs of occlusal veneer. CONCLUSIONS: The fracture resistance of the CAD/CAM lithium disilicate-reinforced ceramic restorations was influenced by the design. Occlusal veneers with and without margin displayed higher fracture resistance than traditional crowns.


Asunto(s)
Porcelana Dental , Diseño de Prótesis Dental , Cerámica , Coronas , Diseño Asistido por Computadora , Ensayo de Materiales , Análisis del Estrés Dental , Fracaso de la Restauración Dental
4.
Oper Dent ; 48(3): 251-257, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37015014

RESUMEN

OBJECTIVES: This case report describes a combination treatment composed of tooth whitening, microabrasion, resin infiltration, and resin-based composite restoration to manage multifactorial stained enamel lesions on anterior teeth. CLINICAL CONSIDERATIONS: The patient's primary concern was to improve the esthetics of their smile after about a decade of extensive orthodontic and orthognathic procedures. After clinical evaluation and history taking, the authors determined that the enamel defects were the result of carious and developmental factors. In-office tooth whitening took place in one visit, followed by micro abrasion and resin infiltration in another visit. Thirteen months later, a follow-up visit showed that the results were stable and that the patient was satisfied with the overall outcome. A small resin composite restoration was added at the follow up visit to repair a previous restoration and to reestablish the facial contours of the central incisor. CONCLUSIONS: A combination treatment protocol composed of tooth whitening, microabrasion, and resin infiltration can improve patient satisfaction and avoid unnecessary invasive treatment.


Asunto(s)
Maloclusión , Decoloración de Dientes , Enfermedades Dentales , Humanos , Microabrasión del Esmalte/métodos , Decoloración de Dientes/terapia , Estética Dental , Dentición , Materiales Dentales , Esmalte Dental/patología , Resinas Compuestas/uso terapéutico
5.
Oper Dent ; 48(3): 245-250, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-36917631

RESUMEN

OBJECTIVE: This case report describes the use of a combination of a polychromatic resin composite restoration and resin infiltration to achieve a satisfactory esthetic outcome that has lasted over five years. CLINICAL CONSIDERATIONS: The patient's primary complaint was a desire to replace an existing stained resin composite on the facial and mesial surfaces of the maxillary left central incisor, and a white spot on the facial surface of the maxillary right central incisor. After clinical evaluation, the patient was offered either replacement of the restoration with a polychromatic restoration simulating a white spot, or a combined treatment with polychromatic composite and resin infiltration restorations, which was recommended. The patient selected the latter treatment. A putty matrix was fabricated, and a quick mock-up was done using various enamel and dentin shades of resin composite to determine proper material selection. The previous resin composite restoration was removed, and layers of new dentin, body, and enamel composite were placed. An interproximal matrix was used in order to provide ideal contour and contact. Finishing and polishing procedures were performed. The maxillary right central incisor was treated with resin infiltration in order to subdue the white spot on the facial surface. CONCLUSIONS: Polychromatic resin composite and resin infiltration restorations to replace a stained restoration and mask a white spot can achieve desired results in the esthetic zone and maintain them for five years.


Asunto(s)
Restauración Dental Permanente , Estética Dental , Humanos , Restauración Dental Permanente/métodos , Resinas Compuestas/uso terapéutico , Esmalte Dental , Atención Odontológica
6.
Oper Dent ; 48(4): 351-357, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37352465

RESUMEN

OBJECTIVES: This case report describes the clinical protocols for using injectable flowable resin-based composite veneers without tooth reduction as long-term prototype restorations, followed by conservative feldspathic veneer restorations. CLINICAL CONSIDERATION: The patient's primary concern was to improve her smile. After clinical evaluation, injectable flowable resin composite veneers were recommended as long-term prototypes followed by conservative tooth preparation and ceramic veneers. Flowable composite veneers were created with a transparent silicone index fabricated from a diagnostic wax-up approved by the patient. No tooth reduction was required to place this type of composite veneer. Later, a printed reduction guide was used to provide conservative tooth preparation followed by the cementation of thin feldspathic porcelain veneers under full isolation with a rubber dam. CONCLUSIONS: Injectable flowable resin-based composite veneers can successfully act as long-term esthetic prototypes before ceramic veneers. The outcome of these restorations is very predictable because the diagnostic wax-up anatomy is transferred to the mouth through the transparent silicone index, and they can be placed without tooth reduction. Conservative tooth preparation can be performed on the composite veneers so that minimal tooth structure is removed to maximize the bonding performance of ceramic veneers.


Asunto(s)
Porcelana Dental , Coronas con Frente Estético , Humanos , Femenino , Porcelana Dental/química , Cerámica , Resinas Compuestas/uso terapéutico
7.
Oper Dent ; 48(4): 358-363, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37079913

RESUMEN

OBJECTIVE: This case report describes a minimally invasive approach with tooth whitening and partial ceramic veneers in the esthetic zone with a 5-year follow-up. CLINICAL CONSIDERATIONS: The patient was initially concerned about the tooth color and previous direct resin composite restorations that chipped on the incisal edges of both maxillary central incisors. Tooth whitening and partial veneers for both central incisors were recommended after clinical evaluation. Two sessions of in-office tooth whitening, first with 35% hydrogen peroxide and later with 10% carbamide peroxide from first premolar to first premolar, were provided. Minimal tooth preparation that only removed the fractured composite restorations was performed followed by placement of feldspathic porcelain ultrathin partial ceramic veneers for both central incisors. We emphasize the benefits of minimal tooth preparation paired with partial ceramic veneers and the importance of masking discolored tooth structure with such thin veneers, including potential tooth whitening. CONCLUSIONS: Overall, we demonstrate a well-planned and executed restorative procedure combining tooth whitening and ultrathin partial ceramic veneers to achieve desired results in the esthetic zone that remained successful for five years.


Asunto(s)
Porcelana Dental , Blanqueamiento de Dientes , Humanos , Porcelana Dental/uso terapéutico , Porcelana Dental/química , Estética Dental , Cerámica/uso terapéutico , Resinas Compuestas/química , Coronas con Frente Estético
8.
Oper Dent ; 47(6): 670-677, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36279319

RESUMEN

OBJECTIVE: To investigate the efficacy of three specially designed polishing kits for provisional restorations made from three chairside computer-aided design and computer-aided manufacturing (CAD/CAM) provisional resin blocks. METHOD: Ninety-six chairside CAD/CAM provisional restorations were milled out of three chairside CAD/CAM provisional resin blocks: (1) ArtBloc Temp (Merz Dental); (2) Telio CAD (Ivoclar Vivadent); and (3) Vita CAD-Temp (VITA Zahnfabrik). The provisional restorations for each material were allocated into the following groups: (1) milled restorations (no polish); (2) polished with CADMaster CAD/CAM Adjustment & Polishing Kit (CM, Shofu); (3) polished with KUT Ultimate Bisacryl (Temporaries) Polishing Kit (KU, Dental Savings Club); and (4) polished with K0330 PMMA Adjusting, Finishing & Polishing (KP, Brasseler USA). Optical profilometry and atomic force microscopy (AFM) were used to assess the surface roughness (Ra) of each provisional restoration at the microscale and nanoscale, respectively, and obtain topographical images. In addition, the milled and polished restorations were visually evaluated by 16 dentists. RESULTS: There was a strong positive correlation with Ra values between optical profilometry and AFM. Only KP significantly improved the surface roughness of CAD/CAM provisional restorations compared to the milled equivalent, regardless of material type or measurement modality (ie, lateral length scale). Although surface topography imaging with AFM revealed some shallow scratches, even for KP polished specimens, all KP polished restorations were categorized as clinically acceptable for provisional restorations in visual inspections from dentists. CONCLUSION: Specially designed polishing kits for provisional restorations did not all improve the surface roughness of chairside CAD/CAM provisional restorations, regardless of the measurement method. KP was more consistently effective in polishing milled chairside CAD/CAM provisional restorations than CM and KU.


Asunto(s)
Pulido Dental , Porcelana Dental , Pulido Dental/métodos , Cerámica , Propiedades de Superficie , Materiales Dentales , Diseño Asistido por Computadora , Ensayo de Materiales
9.
Oper Dent ; 46(5): 477-483, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34624106

RESUMEN

OBJECTIVES: The case report describes a minimally invasive, multidisciplinary approach to a single discolored anterior tooth, with internal bleaching using traditional Japanese paper (Washi), a gingivoplasty with a three-dimensional (3D) printed surgical guide, and ultrathin feldspathic porcelain veneers. CLINICAL CONSIDERATION: The patient's primary concern was improving her smile. After clinical evaluation, internal tooth bleaching for the discolored tooth and gingivoplasty with restoration of the maxillary anterior six teeth and first premolars was recommended. The internal tooth whitening was accomplished with sodium perborate mixed with 30% hydrogen peroxide impregnated in Washi and sealed in the root canal with glass ionomer. Once the tooth bleaching was completed, the 3D printed surgical guide was placed in the patient's maxillary anterior region and used to guide soft tissue recontouring. After 6 months, ultrathin feldspathic porcelain veneers were placed. CONCLUSION: Well-planned restorative procedures combining internal tooth bleaching using Washi, gingivoplasty performed with electrosurgery using a 3D printed surgical guide, and ultrathin feldspathic porcelain veneers can achieve the desired results in the esthetic zone and remain successful for 4 years.


Asunto(s)
Blanqueamiento de Dientes , Decoloración de Dientes , Porcelana Dental , Coronas con Frente Estético , Estética Dental , Femenino , Humanos , Peróxido de Hidrógeno/uso terapéutico , Blanqueamiento de Dientes/métodos
10.
Oper Dent ; 46(5): E185-E198, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-35486512

RESUMEN

This study aimed to evaluate the filler contents (FCs), flexural properties, depth of cure (DOC), wear resistance, and handling properties of different low-viscosity bulk-fill resin composites (LVBRCs) and to determine the correlations between the tested parameters. Six LVBRCs, Beautifil-Bulk (BBF), Bulk Base Hard (BBH), Bulk Base Medium (BBM), Filtek Bulk-Fill Flowable Restorative (FBF), G-ænial Bulk Injectable (GBI), and SDR flow+ Bulk-Fill Flowable (SDR) were used. The DOC and flexural property tests were conducted according to the ISO 4049 specifications. The flexural strength, elastic modulus, and resilience were determined in 12 specimens that were obtained from each of the 6 materials. Sliding-impact-wear testing was conducted by evaluating the wear facets of the specimens using a noncontact profilometer and by confocal laser scanning microscopy. The handling properties of the LVBRC was assessed via extrusion force and thread formation measurements. The DOC for the majority of the LVBRCs was approximately 4 mm. Although the FCs and mechanical properties were material dependent, some LVBRCs exhibited excellent flexural properties and wear resistance. The LVBRCs demonstrated a wide range of extrusion force and thread formation. Regarding the correlations between the tested parameters, extremely strong negative and positive correlations were observed for the DOC versus extrusion force, flexural strength versus elastic modulus, maximum depth versus volume loss, and maximum depth versus thread formation. In addition, strong correlations between FCs and DOC, resilience, wear resistance, and extrusion force were observed.


Asunto(s)
Resistencia Flexional , Fenómenos Mecánicos , Módulo de Elasticidad , Ensayo de Materiales , Viscosidad
11.
Oper Dent ; 46(3): E117-E131, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34370032

RESUMEN

OBJECTIVE: The aim of this study was to determine the flexural properties and surface characteristics of a structural colored resin composite after different finishing and polishing methods, in comparison to those of conventional resin composites. METHODS AND MATERIALS: A structural color resin composite, Omnichroma (OM, Tokuyama Corp, Chiyoda City, Tokyo, Japan), and two comparison resin composites, Filtek Supreme Ultra (FS, 3M, St Paul, MN, USA) and Tetric EvoCeram (TE, Ivoclar Vivadent, Schaan, Liechtenstein), were used. The flexural properties of the resin composites were determined in accordance with the ISO 4049 specifications. For surface properties, 70 polymerized specimens of each resin composite were prepared and divided into seven groups of 10. Surface roughness (Sa), gloss (GU), and surface free energy (SFE) were investigated after the following finishing and polishing methods. Three groups of specimens were finished with a superfine-grit diamond bur (SFD), and three with a tungsten carbide bur (TCB). After finishing, one of the two remaining groups was polished with a one-step silicone point (CMP), and the other with an aluminum oxide flexible disk (SSD). A group ground with SiC 320-grit was set as a baseline. RESULTS: The average flexural strength ranged from 116.6 to 142.3 MPa in the following order with significant differences between each value: FS > TE > OM. The average E ranged from 6.8 to 13.2 GPa in the following order with significant differences between each value: FS > TE > OM. The average R ranged from 0.77 to 1.01 MJ/mm3 in the following order: OM > FS > TE. The Sa values of the OM groups polished with CMP and SSD were found to be significantly lower than those of the other resin composites, regardless of the finishing method. The GU values appeared to be dependent on the material and the finishing method used. The OM specimens polished with SSD showed significantly higher GU values than those polished with CMP. Most of the resin composites polished with SSD demonstrated significantly higher γS values compared to the other groups. Extremely strong negative correlations between Sa and GU in the combined data from the three resin composites and each resin composite and between Sa and γS in the OM specimens were observed; GU showed a strong positive correlation with γS in the same material. CONCLUSION: These findings indicate that both flexural and surface properties are material dependent. Furthermore, the different finishing and polishing methods used in this study were observed to affect the Sa, GU, and SFE of the resin composites.


Asunto(s)
Pulido Dental , Resistencia Flexional , Óxido de Aluminio , Resinas Compuestas , Ensayo de Materiales , Propiedades de Superficie
12.
Oper Dent ; 46(2): 219-225, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-34192321

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the effectiveness of five different polishing systems on a computer-aided design and computer-aided manufacturing (CAD/CAM) polymer-infiltrated ceramic-network restoration with nanoscale assessment using atomic force microscopy (AFM) and visual assessment performed by dental school senior students and faculty members. METHOD: Forty-eight full coverage crowns were milled out of polymer-infiltrated ceramic-network CAD/CAM blocks (Vita Enamic) for polishing with one company proprietary, two ceramic and two composite polishing systems. The prepared crowns were divided into six groups: (1) no polishing (control); (2) polishing with Vita Enamic Polishing Kit (VEna); (3) polishing with Shofu Porcelain Laminate Polishing Kit (SCer); (4) polishing with Brasseler Dialite Feather lite All-Ceramic Adjusting & Polishing System (BCer); (5) polishing with Shofu Composite Polishing Kit (SCom); and (6) polishing with Brasseler Composite Polishing Kit (BCom). The polished crown surface topography was observed, and surface roughness and area were measured with AFM. In addition, polished crowns were visually assessed by 15 senior dental students and 15 dental school faculty members. RESULTS: All polishing treatments significantly reduced the surface roughness and area of the crown compared with the control. SCom and BCom showed significantly higher surface area than VEna, and the SCer and BCer groups were intermediate, showing no significant difference from either VEna or SCom and BCom. There were no significant differences in surface roughness between any of the systems. Dental students and faculty members classified the groups polished with VEna, SCer, and BCer groups as clinically acceptable, and they selected BCer group as the best polished restorations and the control group as the least polished restorations. CONCLUSIONS: Ceramic and composite polishing systems produced similar polishing results as that observed using a company proprietary polishing system. However, effectiveness for polishing using a company proprietary and ceramic polishing system tends to be higher than composite polishing systems.


Asunto(s)
Cerámica , Polímeros , Diseño Asistido por Computadora , Pulido Dental , Porcelana Dental , Humanos , Ensayo de Materiales , Propiedades de Superficie
13.
Oper Dent ; 45(5): 537-546, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32216724

RESUMEN

CLINICAL RELEVANCE: Some bulk-fill flowable resin composites produce less cuspal deflection than a conventional incrementally filled flowable resin composites. SUMMARY: Objective: This study investigated simulated cuspal deflection and flexural properties of bulk-fill and conventional flowable resin composites.Methods and Materials: Five bulk-fill and six conventional flowable resin composites were evaluated. Aluminium blocks with a mesio-occlusal-distal cavity were prepared and randomly divided into groups for each of the different measurement techniques and were further subdivided according to the type of flowable resin composite. The simulated cuspal deflection caused by the polymerization of resin composite within an aluminium block was measured using a highly accurate submicron digimatic micrometer or a confocal laser scanning microscope (CLSM). In addition, the flexural properties of tested resin composites were measured to investigate the relation between cuspal deflection and flexural properties, and the resin composites were observed using scanning electron microscopy.Results: Simulated cuspal deflection of some bulk-fill flowable resin composites was found to be significantly lower than or similar to those for conventional counterparts, regardless of the measurement method. There were statistically significant differences in flexural properties depending on the material, regardless of the type of flowable resin composite. Pearson correlation analysis did not reveal a statistically significant relationship between flexural properties and cuspal deflection.Conclusion: These results indicate that some bulk-fill flowable resin composites exhibit lower cuspal deflection with the bulk-filling technique than is shown by conventional flowable resin composites using the incremental filling technique. Simulated cuspal deflection can be measured using either a micrometer or CLSM, but this experiment failed to show a significant relationship between cuspal deflection and flexural properties of flowable resin composites.


Asunto(s)
Resinas Compuestas , Resistencia Flexional , Ensayo de Materiales , Polimerizacion
14.
Oper Dent ; 45(2): 196-208, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31738692

RESUMEN

The aim of this study was to determine the effect of aluminablasting on the bond durability of universal adhesives and adherent surface characteristics. Adhese Universal (Ivoclar Vivadent), All-Bond Universal (Bisco), Bondmer Lightless (Tokuyama Dental), G-Premio Bond (GC), and Scotchbond Universal (3M ESPE) were used in self-etch mode. The prepared bovine enamel and dentin specimens were divided into two groups based on whether they received an aluminablasting prior to application of the universal adhesives. The resin composite bonded specimens were stored in distilled water at 37°C for 24 hours, following which the shear bond strength (SBS) of half of the specimens was measured (24-hour group). The other half was subjected to 30,000 thermal cycles between 5 and 55°C before SBS measurement (TC group). Surface roughness (Ra) and surface free energy (SFE) of the adherent surfaces were also measured, and scanning electron microscopy observation and scanning electron microscopy/energy-dispersive X-ray analysis were carried out. Most of the adhesives did not show any significant differences in enamel SBS values between the two pretreatment groups, regardless of the storage condition. However, the dentin SBS values were significantly lower in specimens that underwent aluminablasting compared with those that did not, irrespective of their storage conditions. Significantly higher Ra and SFE values were observed in the enamel and dentin of specimens that underwent aluminablasting. Although aluminablasting increased the Ra and SFE values of enamel and dentin, its effect on the SBS value was dependent on the tooth substrate. In addition to C, O, Na, Mg, P, and Ca, the element Al was detected in the enamel and dentin of samples that had undergone aluminablasting. These results suggest that although aluminablasting of the tooth surface is thought to be effective for modification of the adherent surface, it may not enhance enamel bond performance and may also adversely affect the dentin bond effectiveness of the universal adhesives.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Grabado Ácido Dental , Animales , Bovinos , Cementos Dentales , Ensayo de Materiales , Cementos de Resina , Resistencia al Corte , Propiedades de Superficie
15.
Oper Dent ; 45(2): E91-E104, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31738697

RESUMEN

The purpose of this study was to determine the influence of finishing and polishing methods on surface properties of bulk-fill resin composites through surface roughness (Ra) and surface free energy (SFE) measurements, and scanning electron microscopy (SEM) observations. Three bulk-fill resin composites, Tetric EvoCeram Bulk Fill (TB), Filtek Bulk Fill (FB), and Filtek Bulk Fill Flowable Restorative (FF), and two conventional resin composites, Clearfil AP-X (AP) and Estelite ∑ Quick (EQ) were used. Seventy cured specimens of each resin composite were prepared and divided into seven groups of 10 specimens. Ra, SFE measurements, and SEM observations were conducted after finishing and polishing procedures. Three groups of specimens were finished with a fine grit diamond bur (FDB), and three with a tungsten carbide bur (CBB). After finishing, one group from each type of finishing was polished with aluminum oxide flexible disks (SSD) and one group from each type of finishing was polished with diamond particles embedded in a silicone point (CMP). A baseline group of samples that were neither finished nor polished after removing the translucent strips from the surface was examined. Although the baseline group showed significantly lower Ra values than the other groups, most resin composites showed lower Ra values with CBB+SSD than with the other finishing and polishing groups. Among the tested resin composites, EQ showed significantly lower Ra values than the other resin composites, regardless of the finishing and polishing methods. On the other hand, AP showed significantly higher Ra values than the other resin composites in all finishing and polishing groups, apart from FB with FDB. For the finished specimens, most resin composites showed higher SFE values with CBB than with FDB. For the polished specimens, all the tested resin composites with CMP showed lower γS values than those with SSD, regardless of the finishing method. The baseline groups of TB and FB showed significantly lower SFE values than the other finished and polished groups. In the SEM observations, all the examined resin composites showed rougher surfaces after finishing with FDB than with CBB. However, when comparing the different polishing methods (CMP and SSD), surface smoothness appeared to be material dependent.


Asunto(s)
Pulido Dental , Restauración Dental Permanente , Óxido de Aluminio , Resinas Compuestas , Diamante , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie
16.
Oper Dent ; 45(3): 229-234, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31860390

RESUMEN

Bonding to enamel has been shown to provide reliable results, and thus conservative tooth preparations are key to the success of ceramic bonded restorations. The wax-up is the first diagnostic tool available to evaluate discrepancies between current and ideal tooth proportions. The clinician's diagnostic mock-up provides the patient with a visual perception of the size and shape of the proposed restorations. The use of reduction guides assists the restorative dentist in evaluating the specific amount of tooth structure to be removed during preparation. Furthermore, total isolation with a rubber dam prior to bonding the final restorations is crucial for the success of adhesive protocols. The aim of this report is to demonstrate a conservative approach to tooth preparation with a complete isolation technique prior to bonding eight ceramic restorations.


Asunto(s)
Cerámica , Recubrimiento Dental Adhesivo , Esmalte Dental , Porcelana Dental , Coronas con Frente Estético , Humanos , Preparación del Diente
17.
Oper Dent ; 45(6): 655-663, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-32674133

RESUMEN

CLINICAL RELEVANCE: The use of layering techniques is still advisable with many bulk-fill resins and should be the default unless a particular resin is known to not need it. SUMMARY: Objective: The purpose of this study was to investigate how layering techniques affect polymerization shrinkage stresses of high-and low-viscosity bulk-fill resins.Method: Six high-viscosity and six low-viscosity bulk-fill resins were evaluated. Aluminum blocks with a mesial-occlusal-distal (MOD) cavity were machined and randomly divided into groups for different filling techniques (bulk-fill vs horizontal layering vs oblique layering) and further subdivided according to type of resin (high- vs low-viscosity). The cuspal deflection resulting from the polymerization of bulk-fill resin bonded to a MOD cavity within an aluminum block was measured with a digimatic micrometer. Scanning electron microscopy analyses of tested resins were also conducted.Results: In the high-viscosity bulk-fill resins, cuspal deflection of the MOD cavity ranged from 11.2 to 18.2 µm with the bulk-filling technique, from 10.7 to 15.5 µm with the horizontal layering technique, and from 10.9 to 15.2 µm with the oblique layering technique. In the low-viscosity bulk-fill resins, cuspal deflection of the material ranged from 9.2 to 19.8 µm with the bulk-filling technique, from 8.2 to 15.7 µm with the horizontal layering technique, and from 8.4 to 16.4 µm with the oblique layering technique.Conclusion: Cuspal deflections for some high-and low-viscosity bulk-fill resins were significantly reduced by using layering techniques, but the resultant improvement of layering techniques was not applicable to all the bulk-fill resins used in this study.


Asunto(s)
Resinas Compuestas , Restauración Dental Permanente , Ensayo de Materiales , Polimerizacion , Viscosidad
18.
Oper Dent ; 45(2): 183-195, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31567054

RESUMEN

We attempted to determine the effect of universal adhesive application time on dentin bond performance in different etching modes based on shear bond strength (SBS) tests and surface free energy (SFE) measurements. The five universal adhesives used were Adhese Universal (AU), Clearfil Universal Bond Quick (CQ), G-Premio Bond (GP), Scotchbond Universal (SU), and Tokuyama Universal Bond (TU). Bovine dentin specimens were divided into four groups of 10 for each adhesive. SBS and SFE were determined after applying the following surface treatments: 1) self-etch (SE) mode with immediate air blowing after adhesive application (IA treatment), 2) SE mode with prolonged application time (PA treatment), 3) etch-and-rinse (ER) mode with IA treatment, and 4) ER mode with PA treatment. Bonded specimens were subjected to SBS testing. The SFE of adhesive-treated dentin surfaces was measured after rinsing with acetone and water. Three-way analysis of variance revealed that dentin SBS values (p<0.001) were significantly influenced by the factors of adhesive type and application duration, but the factor of pre-etching was not significant (p=0.985). The manufacturer's instructions require longer application times for AU and SU, which showed significantly lower SBS values in IA than in PA treatment in both etching modes. However, the difference in the other adhesives was not significant between the IA and PA treatments in either etching mode. The total SFE (γS) was dependent on the adhesive and etching mode. The γS value of the initial group (SiC paper ground group) at baseline was 69.5 (mN·m-1) and that of the pre-etching group at baseline was 30.6 (mN·m-1). For all the adhesives, γS in SE mode showed significantly higher values than in ER mode, regardless of the application time. In SE mode, almost all universal adhesives tested showed lower γS values in PA treatment than in IA treatment. For ER mode, all the adhesives showed significantly higher γS values than those of the pre-etching baseline, regardless of the application time. Most adhesives did not show any significant differences in γS values between IA and PA treatments, regardless of etching mode.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Grabado Ácido Dental , Adhesivos , Animales , Bovinos , Cementos Dentales , Dentina , Ensayo de Materiales , Cementos de Resina , Resistencia al Corte
19.
Oper Dent ; 45(1): 80-91, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31226005

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate whether different enamel etching methods with reduced etching times would improve the bonding effectiveness of universal adhesives. METHODS AND MATERIALS: Three enamel etching methods, phosphoric acid ester monomer (PPM) etching, phosphoric acid (PPA) etching, and polyalkenoic acid (PLA) etching, and three universal adhesives, G-Premio Bond (GP), Prime&Bond elect (PE), and Scotchbond Universal Adhesive (SU), were evaluated. Initial bond strengths and fatigue strengths of universal adhesives to ground enamel and ground enamel etched for less than one, five, 10, and 15 seconds using different etching methods were determined. The bonded fatigue specimens were loaded using a sine wave at a frequency of 20 Hz for 50,000 cycles or until failure occurred with a staircase method. Atomic force micrograph (AFM) observations along with measurements of surface Ra roughness and modified surface area of enamel with different etching protocols were also conducted. RESULTS: The bond fatigue durability of universal adhesives to enamel with PPA etching from less than one to 15 seconds and PLA etching for 15 seconds was significantly higher than that to ground enamel. The bond fatigue durability to enamel with PPM etching was not increased compared with ground enamel. The surface Ra roughness and surface area obtained with AFM of enamel increased after PPA and PLA etching, and those values were significantly higher than those of ground enamel. Furthermore, surface Ra roughness and surface area with PPA etching were significantly higher than those with PLA etching. However, surface Ra roughness and surface area of enamel with PPM etching were similar to those of ground enamel regardless of etching time. CONCLUSION: PPA etching for less than one to 15 seconds and PLA etching for 15 seconds improve universal adhesive bonding, surface Ra roughness, and surface area of enamel. However, PPM etching is not effective, regardless of etching time, in improving bonds strengths, increasing surface roughness, and increasing surface area.


Asunto(s)
Grabado Ácido Dental , Recubrimiento Dental Adhesivo , Cementos Dentales , Esmalte Dental , Ensayo de Materiales , Ácidos Fosfóricos , Cementos de Resina , Resistencia al Corte , Propiedades de Superficie
20.
Oper Dent ; 44(2): 188-199, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30106329

RESUMEN

The purpose of this study was to determine the effect of different adhesive application methods and etching modes on the dentin bond durability of universal adhesives under thermal cycling (TC). All-Bond Universal (Bisco), Adhese Universal (Ivoclar Vivadent), and Scotchbond Universal (3M ESPE) were used as adhesives. In total, 600 bovine teeth with exposed dentin were divided into 12 groups according to the type of adhesive and subjected to the following bonding procedures: 1) etch-and-rinse mode with active application; 2) etch-and-rinse mode with inactive application; 3) self-etch mode with active application; and 4) self-etch mode with inactive application. Bonded specimens were stored in distilled water at 37°C for 24 hours and then subjected to 5000, 10,000, 30,000, or 50,000 TC between 5°C and 55°C before shear bond strength (SBS) testing, creating a division into a total of five different storage conditions. Baseline specimens were stored in distilled water at 37°C for 24 hours. The SBS test was performed at a cross-head speed of 1.0 mm/min. Three-way analysis of variance revealed that all the factors of application mode, adhesive, and thermal cycle period significantly influenced the SBS values ( p<0.001), regardless of the etching mode. In the baseline groups, all of the tested adhesives with active application had higher SBS values than those with inactive application, regardless of etching mode. In the TC groups, significantly lower SBS values were observed at 50,000 TC with inactive application compared to those with active application, regardless of the etching mode. From the scanning electron microscopy observation of demineralized and deproteinized resin/dentin interfaces, dense resin tags longer than 50 µm were observed in the etch-and-rinse with active application group. On the other hand, the resin tags in self-etch mode were sparse, thin, and much shorter than those in etch-and-rinse mode. Comparing the penetration status of the resin tags with active and inactive application in self-etch mode, the resin tag penetration with inactive application was much lower than that with active application. Active application is effective in enhancing the dentin bond durability of universal adhesives. When using universal adhesives with different etching modes, practitioners should select the optimal etching mode and appropriate application method in accordance with the cavity conditions.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Grabado Ácido Dental , Animales , Bovinos , Cementos Dentales , Dentina , Ensayo de Materiales , Cementos de Resina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA