Artículo en Japonés | MEDLINE | ID: mdl-34148900

RESUMEN

PURPOSE: The aim of this study was to evaluate the classification accuracy of specific blood flow reduction patterns in clinical images by deep learning using simulation data. METHODS: We obtained Z-score maps for 100 cases each of simulated Alzheimer's disease (AD), simulated dementia with Lewy bodies (DLB), and simulated normal cognition (NC) by performing statistical analysis of the simulation data that provided defects and healthy patient data. The clinical images were determined by reference to radiological reports, and Z-score maps of AD (n=33), DLB (n=20), and NC (n=28) were used. A network was constructed with reference to AlexNet, 4-fold cross-validation was performed using only simulation data, and classification accuracy was evaluated. We also trained the model using the simulation data and classified the clinical images. RESULTS: The accuracy rate of classification between simulations was 96.2% and that of the clinical images was 84.2%. CONCLUSION: Through deep learning using simulation data, clinical images may be classified with an accuracy of 84.2%.


Asunto(s)
Enfermedad de Alzheimer , Aprendizaje Profundo , Enfermedad por Cuerpos de Lewy , Enfermedad de Alzheimer/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular , Diagnóstico Diferencial , Humanos , Enfermedad por Cuerpos de Lewy/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único
SELECCIÓN DE REFERENCIAS