Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Br J Surg ; 96(2): 214-20, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19160367

RESUMEN

BACKGROUND: Direct colonic electrical stimulation may prove to be a treatment option for specific motility disorders such as chronic constipation. The aim of this study was to provoke colonic contractions using electrical stimulation delivered from a battery-operated device. METHODS: Electrodes were inserted into the caecal seromuscular layer of eight anaesthetized pigs. Contractions were induced by a neurostimulator (Medtronic 3625). Caecal motility was measured simultaneously by video image analysis, manometry and a technique assessing colonic transit. RESULTS: Caecal contractions were generated using 8-10 V amplitude, 1000 micros pulse width, 120 Hz frequency for 10-30 s, with an intensity of 7-15 mA. The maximal contraction strength was observed after 20-25 s. Electrical stimulation was followed by a relaxation phase of 1.5-2 min during which contractions propagated orally and aborally over at least 10 cm. Spontaneous and stimulated caecal motility values were significantly different for both intraluminal pressure (mean(s.d.) 332(124) and 463(187) mmHg respectively; P < 0.001, 42 experiments) and movement of contents (1.6(0.9) and 3.9(2.8) mm; P < 0.001, 40 experiments). CONCLUSION: Electrical stimulation modulated caecal motility, and provoked localized and propagated colonic contractions.


Asunto(s)
Colon/fisiología , Estimulación Eléctrica , Animales , Ciego/fisiología , Electrodos , Motilidad Gastrointestinal/fisiología , Contracción Muscular/fisiología , Presión , Porcinos
2.
IEEE Trans Biomed Eng ; 47(5): 578-82, 2000 May.
Artículo en Inglés | MEDLINE | ID: mdl-10851800

RESUMEN

We present a novel method which provides an observer of the autonomic cardiac outflow using heartbeat intervals (RR) and QT intervals. The model of the observer is inferred from qualitative physiological knowledge. It consists in a problem of blind source separation of noisy mixtures which is resolved by a simple and robust algorithm. The robustness of the algorithm has been assessed by numerical simulations in adverse noisy environments. In clinical applications, we have validated the observer on subjects exposed to experimental conditions known to elicit sympathetic or parasympathetic response.


Asunto(s)
Sistema Nervioso Autónomo/fisiología , Electrocardiografía , Modelos Cardiovasculares , Procesamiento de Señales Asistido por Computador , Algoritmos , Análisis de Varianza , Humanos
3.
IEEE Trans Biomed Eng ; 48(11): 1229-37, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11686622

RESUMEN

Atrial fibrillation is the most frequent arrhythmia, provoking discomfort, heart failure and arterial embolisms. The aim of this work is to develop a simplified anatomical computer model of human atria for the study of atrial arrhythmias and the understanding of electrical propagation mechanisms. With the model we propose, up to 40 s of real-time propagation have been simulated on a single-processor computer. The size and the electrophysiological properties of the simulated atria are within realistic values and information about anatomy has been taken into account in a three-dimensional structure. Besides normal sinus beat, pathological phenomena such as flutter and fibrillation have been induced using a programmed stimulation protocol. One important observation in our model is that atrial arrhythmias are a combination of functional and anatomical reentries and that the geometry plays an important role. This virtual atrium can reproduce electrophysiological observations made in humans but with the advantage of showing in great detail how arrhythmias are initiated and sustained. Such details are difficult or impossible to study in humans. This model will serve us as a tool to evaluate the impact of new therapeutic strategies and to improve them.


Asunto(s)
Simulación por Computador , Corazón/anatomía & histología , Corazón/fisiología , Modelos Cardiovasculares , Fibrilación Atrial/fisiopatología , Función Atrial , Ingeniería Biomédica , Electrofisiología , Atrios Cardíacos/anatomía & histología , Humanos , Modelos Anatómicos , Interfaz Usuario-Computador
4.
Chaos ; 12(3): 754-763, 2002 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12779604

RESUMEN

The maintenance of multiple wavelets appears to be a consistent feature of atrial fibrillation (AF). In this paper, we investigate possible mechanisms of initiation and perpetuation of multiple wavelets in a computer model of AF. We developed a simplified model of human atria that uses an ionic-based membrane model and whose geometry is derived from a segmented magnetic resonance imaging data set. The three-dimensional surface has a realistic size and includes obstacles corresponding to the location of major vessels and valves, but it does not take into account anisotropy. The main advantage of this approach is its ability to simulate long duration arrhythmias (up to 40 s). Clinically relevant initiation protocols, such as single-site burst pacing, were used. The dynamics of simulated AF were investigated in models with different action potential durations and restitution properties, controlled by the conductance of the slow inward current in a modified Luo-Rudy model. The simulation studies show that (1) single-site burst pacing protocol can be used to induce wave breaks even in tissue with uniform membrane properties, (2) the restitution-based wave breaks in an atrial model with realistic size and conduction velocities are transient, and (3) a significant reduction in action potential duration (even with apparently flat restitution) increases the duration of AF. (c) 2002 American Institute of Physics.

5.
Neurogastroenterol Motil ; 22(1): 88-92, e31, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19594689

RESUMEN

Electrical stimulation is a new way to treat digestive disorders such as constipation. Colonic propulsive activity can be triggered by battery operated devices. This study aimed to demonstrate the effect of direct electrical colonic stimulation on mean transit time in a chronic porcine model. The impact of stimulation and implanted material on the colonic wall was also assessed. Three pairs of electrodes were implanted into the caecal wall of 12 anaesthetized pigs. Reference colonic transit time was determined by radiopaque markers for each pig before implantation. It was repeated 4 weeks after implantation with sham stimulation and 5 weeks after implantation with electrical stimulation. Aboral sequential trains of 1-ms pulse width (10 V; 120 Hz) were applied twice daily for 6 days, using an external battery operated stimulator. For each course of markers, a mean value was computed from transit times obtained from individual pig. Microscopic examination of the caecum was routinely performed after animal sacrifice. A reduction of mean transit time was observed after electrical stimulation (19 +/- 13 h; mean +/- SD) when compared to reference (34 +/- 7 h; P = 0.045) and mean transit time after sham stimulation (36 +/- 9 h; P = 0.035). Histological examination revealed minimal chronic inflammation around the electrodes. Colonic transit time measured in a chronic porcine model is reduced by direct sequential electrical stimulation. Minimal tissue lesion is elicited by stimulation or implanted material. Electrical colonic stimulation could be a promising approach to treat specific disorders of the large bowel.


Asunto(s)
Colon/fisiología , Estimulación Eléctrica , Tránsito Gastrointestinal/fisiología , Animales , Colon/anatomía & histología , Medios de Contraste/metabolismo , Electrodos Implantados , Femenino , Humanos , Modelos Animales , Porcinos
6.
Ann Biomed Eng ; 33(4): 465-74, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15909652

RESUMEN

Atrial fibrillation (AF) is the most common form of cardiac arrhythmia. Surgical/Radiofrequency (RF) ablation is a therapeutic procedure that consists of creating lines of conduction block to interrupt AF. The present study evaluated 13 different ablation patterns by means of a biophysical model of the human atria. In this model, ablation lines were abruptly applied transmurally during simulated sustained AF, and success rate, time to AF termination and average beat-to-beat interval were documented. The gold standard Cox's Maze III procedure was taken as reference. The effectiveness of twelve less invasive patterns was compared to it. In some of these incomplete lines (entailing a gap) were simulated. Finally, the computer simulations were compared to clinical data. The results show that the model reproduces observations made in vivo: (1) the Maze III is the most efficient ablation procedure; (2) less invasive patterns should include lines in both right and left atrium; (3) incomplete ablation lines between the pulmonary veins and the mitral valve annulus lead to uncommon flutter; (4) computer simulations of incomplete lines are consistent with clinical results of non-transumural RF ablation. Biophysical modeling may therefore be considered as a useful tool for understanding the mechanisms underlying AF therapies.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Conducción Cardíaco/cirugía , Modelos Cardiovasculares , Cirugía Asistida por Computador/métodos , Fibrilación Atrial/diagnóstico , Simulación por Computador , Humanos , Modelos Neurológicos , Pronóstico , Resultado del Tratamiento
7.
Pacing Clin Electrophysiol ; 21(11 Pt 2): 2366-71, 1998 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9825349

RESUMEN

Modern computer power allows development of models of the heart that may be helpful for the understanding of arrhythmia mechanisms if, based on realistic physiological parameters, such models can display phenomena difficult to study in nature. Therefore, a two-dimensional model of the cardiac tissue has been implemented, where the modeling of each cell is based on membrane ionic channels (Beeler-Reuter and Luo-Rudy models). In addition, an ECG was computed based on the ionic currents simulated. This model allows us to observe the propagation of the action potentials Vm across the cardiac tissue, the evolution of Vm for any of the cardiac cells, and the underlying ionic currents. The computation of the ECG makes it possible to relate this information with an often-used diagnostic tool. Simulations of normal and pathological phenomena such as functional and anatomic reentry have been performed. Our simulation results show that the applied computer model based on ionic currents seems accurate and realistic when compared with biological models and offers a new approach to study the origin, prevention, and termination of arrhythmias.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Simulación por Computador , Electrocardiografía , Sistema de Conducción Cardíaco/fisiopatología , Modelos Cardiovasculares , Potenciales de Acción/fisiología , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA