Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Proc Natl Acad Sci U S A ; 121(21): e2322974121, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38743621

RESUMEN

SRSF1 is the founding member of the SR protein family. It is required-interchangeably with other SR proteins-for pre-mRNA splicing in vitro, and it regulates various alternative splicing events. Dysregulation of SRSF1 expression contributes to cancer and other pathologies. Here, we characterized SRSF1's interactome using proximity labeling and mass spectrometry. This approach yielded 190 proteins enriched in the SRSF1 samples, independently of the N- or C-terminal location of the biotin-labeling domain. The detected proteins reflect established functions of SRSF1 in pre-mRNA splicing and reveal additional connections to spliceosome proteins, in addition to other recently identified functions. We validated a robust interaction with the spliceosomal RNA helicase DDX23/PRP28 using bimolecular fluorescence complementation and in vitro binding assays. The interaction is mediated by the N-terminal RS-like domain of DDX23 and both RRM1 and the RS domain of SRSF1. During pre-mRNA splicing, DDX23's ATPase activity is essential for the pre-B to B spliceosome complex transition and for release of U1 snRNP from the 5' splice site. We show that the RS-like region of DDX23's N-terminal domain is important for spliceosome incorporation, while larger deletions in this domain alter subnuclear localization. We discuss how the identified interaction of DDX23 with SRSF1 and other SR proteins may be involved in the regulation of these processes.


Asunto(s)
ARN Helicasas DEAD-box , Factores de Empalme Serina-Arginina , Empalmosomas , Humanos , ARN Helicasas DEAD-box/metabolismo , ARN Helicasas DEAD-box/genética , Células HeLa , Unión Proteica , Precursores del ARN/metabolismo , Precursores del ARN/genética , Empalme del ARN , Factores de Empalme Serina-Arginina/metabolismo , Factores de Empalme Serina-Arginina/genética , Empalmosomas/metabolismo
2.
Microsc Microanal ; 29(2): 616-634, 2023 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-37749742

RESUMEN

This article outlines a global study conducted by the Association of Biomedical Resource Facilities (ABRF) Light Microscopy Research Group (LMRG). The results present a novel 3D tissue-like biologically relevant standard sample that is affordable and straightforward to prepare. Detailed sample preparation, instrument-specific image acquisition protocols and image analysis methods are presented and made available to the community. The standard consists of sub-resolution and large well characterized relative intensity fluorescence microspheres embedded in a 120 µm thick 3D gel with a refractive index of 1.365. The standard allows the evaluation of several properties as a function of depth. These include the following: 1) microscope resolution with automated analysis of the point-spread function (PSF), 2) automated signal-to-noise ratio analysis, 3) calibration and correction of fluorescence intensity loss, and 4) quantitative relative intensity. Results demonstrate expected refractive index mismatch dependent losses in intensity and resolution with depth, but the relative intensities of different objects at similar depths are maintained. This is a robust standard showing reproducible results across laboratories, microscope manufacturers and objective lens types (e.g., magnification, immersion medium). Thus, these tools will be valuable for the global community to benchmark fluorescence microscopes and will contribute to improved scientific rigor and reproducibility.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Reproducibilidad de los Resultados , Microscopía Fluorescente/métodos
3.
Genes Dev ; 29(4): 426-39, 2015 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-25691469

RESUMEN

The initiation of chromosome morphogenesis marks the beginning of mitosis in all eukaryotic cells. Although many effectors of chromatin compaction have been reported, the nature and design of the essential trigger for global chromosome assembly remain unknown. Here we reveal the identity of the core mechanism responsible for chromosome morphogenesis in early mitosis. We show that the unique sensitivity of the chromosome condensation machinery for the kinase activity of Cdk1 acts as a major driving force for the compaction of chromatin at mitotic entry. This sensitivity is imparted by multisite phosphorylation of a conserved chromatin-binding sensor, the Smc4 protein. The multisite phosphorylation of this sensor integrates the activation state of Cdk1 with the dynamic binding of the condensation machinery to chromatin. Abrogation of this event leads to chromosome segregation defects and lethality, while moderate reduction reveals the existence of a novel chromatin transition state specific to mitosis, the intertwist configuration. Collectively, our results identify the mechanistic basis governing chromosome morphogenesis in early mitosis and how distinct chromatin compaction states can be established via specific thresholds of Cdk1 kinase activity.


Asunto(s)
División Celular/genética , Cromosomas Fúngicos/genética , Quinasas Ciclina-Dependientes/metabolismo , Saccharomyces cerevisiae/citología , Saccharomyces cerevisiae/genética , Adenosina Trifosfatasas/química , Adenosina Trifosfatasas/metabolismo , Ensamble y Desensamble de Cromatina/genética , Proteínas Cromosómicas no Histona/metabolismo , Proteínas de Unión al ADN/química , Proteínas de Unión al ADN/metabolismo , Genes de Cambio/fisiología , Mitosis , Complejos Multiproteicos/química , Complejos Multiproteicos/metabolismo , Fosforilación , Unión Proteica , Proteínas de Saccharomyces cerevisiae/metabolismo
4.
Histochem Cell Biol ; 151(4): 357-366, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30767050

RESUMEN

The process of fluorescence starts with the efficient generation of light that is required for the excitation of fluorophores. As such, light sources are a crucial component of a fluorescence microscope. Choosing the right illumination tool can not only improve the quality of experimental results, but also the microscope's economic and environmental footprint. While arc lamps have historically proven to be a reliable light source for widefield fluorescence microscopy, solid-state light-emitting diodes (LEDs) have become the light source of choice for new fluorescence microscopy systems. In this paper, we demonstrate that LEDs have superior light stability on all timescales tested and use less electrical power than traditional light sources when used at lower power outputs. They can be readily switched on and off electronically, have a longer lifetime and they do not contain mercury, and thus are better for the environment. We demonstrate that it is important to measure light source power output during warm-up and switching, as a light source's responsiveness (in terms of power) can be quite variable. Several general protocols for testing light source stability are presented. A detailed life cycle analysis shows that an LED light source can have a fourfold lower environmental impact when compared to a metal halide source.


Asunto(s)
Iluminación/instrumentación , Microscopía Fluorescente/instrumentación
5.
bioRxiv ; 2023 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-37961255

RESUMEN

Chromatin organization in the mammalian cell nucleus plays a vital role in the regulation of gene expression. The lamina-associated domain at the inner nuclear membrane has been proposed to harbor heterochromatin, while the nuclear interior has been shown to contain most of the euchromatin. Here, we show that a sub-set of actively transcribing genes, marked by RNA Pol II pSer2, are associated with Lamin B1 at the inner nuclear envelop in mESCs and the number of genes proportionally increases upon in vitro differentiation of mESC to olfactory precursor cells. These nuclear periphery-associated actively transcribing genes primarily represent housekeeping genes, and their gene bodies are significantly enriched with guanine and cytosine compared to genes actively transcribed at the nuclear interior. We found the promoters of these genes to also be significantly enriched with guanine and to be predominantly regulated by zinc finger protein transcription factors. We provide evidence supporting the emerging notion that the Lamin B1 region is not solely transcriptionally silent.

6.
Nat Neurosci ; 25(10): 1273-1278, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36171430

RESUMEN

Oligodendrocyte precursor cells (OPCs) give rise to myelinating oligodendrocytes throughout life, but the functions of OPCs are not limited to oligodendrogenesis. Here we show that OPCs contribute to thalamocortical presynapse elimination in the developing and adult mouse visual cortex. OPC-mediated synapse engulfment increases in response to sensory experience during neural circuit refinement. Our data suggest that OPCs may regulate synaptic connectivity in the brain independently of oligodendrogenesis.


Asunto(s)
Células Precursoras de Oligodendrocitos , Animales , Encéfalo , Diferenciación Celular/fisiología , Ratones , Ratones Transgénicos , Células Precursoras de Oligodendrocitos/fisiología , Oligodendroglía/fisiología , Sinapsis
7.
J Am Chem Soc ; 133(42): 16742-5, 2011 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-21942296

RESUMEN

New cobalt-based nanocomposites have been prepared by photoreduction of Co(2+) salts to generate cobalt nanoparticles deposited on carbon-based materials such as nanocyrstalline diamond and carbon felt. Spontaneous air oxidation converts the metal to Co(2)O(3) which has been tested as a water oxidation catalyst. This work demonstrates that the cobalt oxide nanostructures can be deposited on various carbon surfaces and can catalyze the four-electron oxidation of water to oxygen under anodic bias.


Asunto(s)
Cobalto/química , Nanoestructuras/química , Agua/química , Catálisis , Microscopía Electrónica de Transmisión , Estructura Molecular , Oxidación-Reducción , Fotoquímica , Difracción de Rayos X
8.
Cell Rep ; 37(7): 110027, 2021 11 16.
Artículo en Inglés | MEDLINE | ID: mdl-34788609

RESUMEN

Early steps of cancer initiation and metastasis, while critical for understanding disease mechanisms, are difficult to visualize and study. Here, we describe an approach to study the processes of initiation, progression, and metastasis of prostate cancer (PC) in a genetically engineered RapidCaP mouse model, which combines whole-organ imaging by serial two-photon tomography (STPT) and post hoc thick-section immunofluorescent (IF) analysis. STPT enables the detection of single tumor-initiating cells within the entire prostate, and consequent IF analysis reveals a transition from normal to transformed epithelial tissue and cell escape from the tumor focus. STPT imaging of the liver and brain reveal the distribution of multiple metastatic foci in the liver and an early-stage metastatic cell invasion in the brain. This imaging and data analysis pipeline can be readily applied to other mouse models of cancer, offering a highly versatile whole-organ platform to study in situ mechanisms of cancer initiation and progression.


Asunto(s)
Metástasis de la Neoplasia/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Animales , Encéfalo/patología , Neoplasias Encefálicas/patología , Modelos Animales de Enfermedad , Inmunohistoquímica/métodos , Hígado/patología , Masculino , Ratones , Ratones Endogámicos C57BL , Metástasis de la Neoplasia/patología , Próstata/patología , Neoplasias de la Próstata/inmunología , Análisis de la Célula Individual , Tomografía Computarizada de Emisión/métodos
9.
Sci Rep ; 9(1): 11430, 2019 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-31391572

RESUMEN

Cell migration is an important biological phenomenon involved in many homeostatic and aberrant physiological processes. Phosphorylation of the focal adhesion adaptor protein, paxillin, on serine 273 (S273) has been implicated as a key regulator of cell migration. Here, it is shown that phosphorylation on paxillin S273 leads to highly migratory cells with small dynamic adhesions. Adhesions at protrusive edges of the cell were more dynamic than adhesions at retracting edges. Temporal image correlation microscopy revealed that these dynamic adhesions undergo rapid binding of paxillin, PAK1 and ßPIX. We identified membrane proximal adhesion subdomains in protrusive regions of the cell that show rapid protein binding that is dependent on paxillin S273 phosphorylation, PAK1 kinase activity and phosphatases. These dynamic adhesion subdomains corresponded to regions of the adhesion that also show co-binding of paxillin/PAK1 and paxillin/ßPIX complexes. It is likely that parts of individual adhesions are more dynamic while others are less dynamic due to their association with the actin cytoskeleton. Variable adhesion and binding dynamics are regulated via differential paxillin S273 phosphorylation across the cell and within adhesions and are required for regulated cell migration. Dysregulation through phosphomutants, PAK1-KD or ßPIX mutants resulted in large stable adhesions, long protein binding times and slow cell migration. Dysregulation through phosphomimics or PAK1-CA led to small dynamic adhesions and rapid cell migration reminiscent of highly migratory cancer cells. Thus, phosphorylation of paxillin S273 is a key regulator of cell migration through recruitment of ßPIX and PAK1 to sites of adhesion.


Asunto(s)
Adhesión Celular , Movimiento Celular , Paxillin/metabolismo , Factores de Intercambio de Guanina Nucleótido Rho/metabolismo , Quinasas p21 Activadas/metabolismo , Animales , Células CHO , Cricetulus , Microscopía Intravital , Microscopía Fluorescente , Mutación , Paxillin/genética , Fosforilación/genética , Unión Proteica/genética , Dominios Proteicos/genética , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Factores de Intercambio de Guanina Nucleótido Rho/genética , Serina/genética , Serina/metabolismo , Quinasas p21 Activadas/genética
10.
Int J Biochem Cell Biol ; 89: 120-124, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28606390

RESUMEN

Light microscopy has grown to be a valuable asset in both the physical and life sciences. It is a highly quantitative method available in individual research laboratories and often centralized in core facilities. However, although quantitative microscopy is becoming a customary tool in research, it is rarely standardized. To achieve accurate quantitative microscopy data and reproducible results, three levels of standardization must be considered: (1) aspects of the microscope, (2) the sample, and (3) the detector. The accuracy of the data is only as reliable as the imaging system itself, thereby imposing the need for routine standard performance testing. Depending on the task some maintenance procedures should be performed once a month, some before each imaging session, while others conducted annually. This text should be implemented as a resource for researchers to integrate with their own standard operating procedures to ensure the highest quality quantitative microscopy data.


Asunto(s)
Luz , Microscopía/métodos , Microscopía/normas , Microscopía/instrumentación , Control de Calidad , Estándares de Referencia , Reproducibilidad de los Resultados
12.
Biotechniques ; 61(2): 73-82, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27528072

RESUMEN

Here we present a high-throughput, parallelized cytoindentor for local compression of live cells. The cytoindentor uses convex lens-induced confinement (CLiC) to indent micrometer-sized areas in single cells and/or populations of cells with submicron precision. This is accomplished using micropatterned poly(dimethylsiloxane) (PDMS) films that are adhered to a convex lens to create arrays of extrusions referred to here as "posts." These posts caused local deformation of subcellular regions without any evidence of cell lysis upon CLiC indentation. Our micropost arrays were also functionalized with glycoproteins, such as fibronectin, to both pull and compress cells under customized confinement geometries. Measurements of Chinese hamster ovary (CHO-K1) cell migration trajectories and oxidative stress showed that the CLiC device did not damage or significantly stress the cells. Our novel tool opens a new area of investigation for visualizing mechanobiology and mechanochemistry within living cells, and the high-throughput nature of the technique will streamline investigations as current tools for mechanically probing material properties and molecular dynamics within cells, such as traditional cytoindentors and atomic force microscopy (AFM), are typically restricted to single-cell manipulation.


Asunto(s)
Técnicas Citológicas/instrumentación , Técnicas Citológicas/métodos , Microscopía Confocal/métodos , Animales , Fenómenos Biomecánicos/fisiología , Células CHO , Fenómenos Fisiológicos Celulares/fisiología , Cricetinae , Cricetulus , Dimetilpolisiloxanos/química , Diseño de Equipo , Ensayos Analíticos de Alto Rendimiento/instrumentación , Microtecnología/instrumentación , Propiedades de Superficie
13.
Sci Rep ; 6: 30892, 2016 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-27485088

RESUMEN

It is important to determine the most effective method of delivering light onto a specimen for minimal light induced damage. Assays are presented to measure photo-bleaching of fluorophores and photo-toxicity to living cells under different illumination conditions. Turning the light off during part of the experimental time reduced photo-bleaching in a manner proportional to the time of light exposure. The rate of photo-bleaching of EGFP was reduced by 9-fold with light pulsing on the micro-second scale. Similarly, in living cells, rapid line scanning resulted in reduced cell stress as measured by mitochondrial potential, rapid cell protrusion and reduced cell retraction. This was achieved on a commercial confocal laser scanning microscope, without any compromise in image quality, by using rapid laser scan settings and line averaging. Therefore this technique can be implemented broadly without any software or hardware upgrades. Researchers can use the rapid line scanning option to immediately improve image quality on fixed samples, reduce photo-bleaching for large high resolution 3D datasets and improve cell health in live cell experiments. The assays developed here can be applied to other microscopy platforms to measure and optimize light delivery for minimal sample damage and photo-toxicity.


Asunto(s)
Luz/efectos adversos , Microscopía Confocal/métodos , Microscopía Fluorescente/métodos , Fotoblanqueo/efectos de la radiación , Animales , Células CHO , Cricetulus , Dosis de Radiación
14.
J Biomol Tech ; 25(1): 31-40, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24688321

RESUMEN

Deconvolution enhances contrast in fluorescence microscopy images, especially in low-contrast, high-background wide-field microscope images, improving characterization of features within the sample. Deconvolution can also be combined with other imaging modalities, such as confocal microscopy, and most software programs seek to improve resolution as well as contrast. Quantitative image analyses require instrument calibration and with deconvolution, necessitate that this process itself preserves the relative quantitative relationships between fluorescence intensities. To ensure that the quantitative nature of the data remains unaltered, deconvolution algorithms need to be tested thoroughly. This study investigated whether the deconvolution algorithms in AutoQuant X3 preserve relative quantitative intensity data. InSpeck Green calibration microspheres were prepared for imaging, z-stacks were collected using a wide-field microscope, and the images were deconvolved using the iterative deconvolution algorithms with default settings. Afterwards, the mean intensities and volumes of microspheres in the original and the deconvolved images were measured. Deconvolved data sets showed higher average microsphere intensities and smaller volumes than the original wide-field data sets. In original and deconvolved data sets, intensity means showed linear relationships with the relative microsphere intensities given by the manufacturer. Importantly, upon normalization, the trend lines were found to have similar slopes. In original and deconvolved images, the volumes of the microspheres were quite uniform for all relative microsphere intensities. We were able to show that AutoQuant X3 deconvolution software data are quantitative. In general, the protocol presented can be used to calibrate any fluorescence microscope or image processing and analysis procedure.


Asunto(s)
Calibración/normas , Imagen Óptica/normas , Procesamiento de Imagen Asistido por Computador/normas , Microscopía , Programas Informáticos
15.
J Phys Chem A ; 111(38): 9379-86, 2007 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-17705460

RESUMEN

Two-photon fluorescence spectroscopy of negatively charged nitrogen-vacancy [(N-V)-] centers in type Ib diamond single crystals have been studied with a picosecond (7.5 ps) mode-locked Nd:YVO(4) laser operating at 1064 nm. The (N-V)- centers were produced by radiation damage of diamond using a 3 MeV proton beam, followed by thermal annealing at 800 degrees C. Prior to the irradiation treatment, infrared spectroscopy of the C-N vibrational modes at 1344 cm(-1) suggested a nitrogen content of 109 +/- 10 ppm. Irradiation and annealing of the specimen led to the emergence of a new absorption band peaking at approximately 560 nm. From a measurement of the integrated absorption intensity of the sharp zero-phonon line (637 nm) at liquid nitrogen temperature, we determined a (N-V)- density of (4.5 +/- 1.1) x 10(18) centers/cm3 (or 25 +/- 6 ppm) for the substrate irradiated at a dose of 1 x 1016) H(+)/cm(2). Such a high defect density allowed us to observe two-photon excited fluorescence and measure the corresponding fluorescence decay time. No significant difference in the spectral feature and fluorescence lifetime was observed between one-photon and two-photon excitations. Assuming that the fluorescence quantum yields are the same for both processes, a two-photon absorption cross section of sigma(TPA) = (0.45 +/- 0.23) x 10(-50) cm(4).s/photon at 1064 nm was determined for the (N-V)- center based on its one-photon absorption cross section of sigma(OPA) = (3.1 +/- 0.8) x 10(-17) cm2 at 532 nm. The material is highly photostable and shows no sign of photobleaching even under continuous two-photon excitation at a peak power density of 3 GW/cm(2) for 5 min.


Asunto(s)
Diamante/química , Rayos Láser , Nitrógeno/química , Fotones , Cristalización , Microscopía Fluorescente , Análisis Espectral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA