Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Thorac Cardiovasc Surg ; 161(3): 1035-1041.e1, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33070939

RESUMEN

OBJECTIVE: We evaluated whether volume-based, rather than time-based, annual reporting of center outcomes for coronary artery bypass grafting may improve inference of quality, assuming that large center-level year-to-year outcome variability is related to statistical noise. METHODS: We analyzed 2012 to 2016 data on isolated coronary artery bypass grafting using statewide outcome reports from New York and California. Annual changes in center-level observed-to-expected mortality ratio represented stability of year-to-year outcomes. Cubic spline fit related the annual observed-to-expected ratio change and center volume. Volume above the inflection point of the spline curve indicated centers with low year-to-year change in outcome. We compared observed-to-expected ratio changes between centers below and above the volume threshold and observed-to-expected ratio changes between consecutive annual and biennial measurements. RESULTS: There were 155 centers with median annual volume of 89 (interquartile range, 55-160) for isolated coronary artery bypass grafting. The inflection point of observed-to-expected ratio variability was observed at 111 cases/year. Median year-to-year observed-to-expected ratio change for centers performing less than 111 cases (62 centers) was greater at 0.83 (0.26-1.59) compared with centers performing 111 cases or more (93 centers) at 0.49 (022-0.87) (P < .001). By aggregating the outcome over 2 years, centers above the 111-case threshold increased from 93 centers (60%) to 118 centers (76%), but the median observed-to-expected change for all centers was similar between annual aggregates at 0.70 (0.26-1.22) compared with observed-to-expected change between biennial aggregates at 0.54 (0.23-1.02) (P = .095). CONCLUSIONS: Center-level, risk-adjusted coronary artery bypass grafting mortality varies significantly from one year to the next. Reporting outcomes by specific case volume may complement annual reports.


Asunto(s)
Puente de Arteria Coronaria/tendencias , Enfermedad de la Arteria Coronaria/cirugía , Hospitales de Alto Volumen/tendencias , Hospitales de Bajo Volumen/tendencias , Evaluación de Procesos y Resultados en Atención de Salud/tendencias , Pautas de la Práctica en Medicina/tendencias , California , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/mortalidad , Bases de Datos Factuales , Humanos , New York , Indicadores de Calidad de la Atención de Salud/tendencias , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA