Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Neurocrit Care ; 40(2): 674-688, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37523110

RESUMEN

BACKGROUND: Family caregivers of patients with severe acute brain injury (SABI) admitted to intensive care units (ICUs) with coma experience heightened emotional distress stemming from simultaneous stressors. Stress and coping frameworks can inform psychosocial intervention development by elucidating common challenges and ways of navigating such experiences but have yet to be employed with this population. The present study therefore sought to use a stress and coping framework to characterize the stressors and coping behaviors of family caregivers of patients with SABI hospitalized in ICUs and recovering after coma. METHODS: Our qualitative study recruited a convenience sample from 14 US neuroscience ICUs. Participants were family caregivers of patients who were admitted with ischemic stroke, intracerebral hemorrhage, subarachnoid hemorrhage, traumatic brain injury, or hypoxic-ischemic encephalopathy; had experienced a comatose state for > 24 h; and completed or were scheduled for tracheostomy and/or gastrostomy tube placement. Participants were recruited < 7 days after transfer out of the neuroscience ICU. We conducted live online video interviews from May 2021 to January 2022. One semistructured interview per participant was recorded and subsequently transcribed. Recruitment was stopped when thematic saturation was reached. We deductively derived two domains using a stress and coping framework to guide thematic analysis. Within each domain, we inductively derived themes to comprehensively characterize caregivers' experiences. RESULTS: We interviewed 30 caregivers. We identified 18 themes within the two theory-driven domains, including ten themes describing practical, social, and emotional stressors experienced by caregivers and eight themes describing the psychological and behavioral coping strategies that caregivers attempted to enact. Nearly all caregivers described using avoidance or distraction as an initial coping strategy to manage overwhelming emotions. Caregivers also expressed awareness of more adaptive strategies (e.g., cultivation of positive emotions, acceptance, self-education, and soliciting social and medical support) but had challenges employing them because of their heightened emotional distress. CONCLUSIONS: In response to substantial stressors, family caregivers of patients with SABI attempted to enact various psychological and behavioral coping strategies. They described avoidance and distraction as less helpful than other coping strategies but had difficulty engaging in alternative strategies because of their emotional distress. These findings can directly inform the development of additional resources to mitigate the long-term impact of acute psychological distress among this caregiver population.


Asunto(s)
Cuidadores , Habilidades de Afrontamiento , Humanos , Cuidadores/psicología , Coma , Adaptación Psicológica , Unidades de Cuidados Intensivos
2.
Appl Opt ; 62(23): 6218-6233, 2023 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-37707091

RESUMEN

An existing chlorophyll-based model has been updated and re-calibrated using measured data describing Jerlov water types, harvested from the World-wide Ocean Optics Database. This study has provided new chlorophyll concentration data, and used them in conjunction with recently published spectra of absorption and scattering coefficients to create an updated parameter set that describes eight of the 10 Jerlov water types. The updated model is consistent with other data, and it interprets the measured characteristics in terms of underlying properties. Techniques for inter-conversion between inherent and apparent optical properties have been further investigated, and the improved precision has uncovered new challenges that have been addressed using empirical techniques.

3.
Appl Opt ; 61(33): 9951-9961, 2022 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-36606827

RESUMEN

Inherent optical properties (IOPs) of typical ocean waters have been derived from a worldwide database of measured parameters. The optical quality of the world's oceans can be described in terms of their Jerlov water type, ranging from the clearest Jerlov I to the most turbid Jerlov 9C. These Jerlov classifications are defined in terms of an apparent optical property known as the downwelling diffuse attenuation coefficient (Kd). There is a need to relate these Jerlov water types to their IOPs, namely their absorption coefficient, a, and scattering coefficient, b. However, robust values of a and b for Jerlov water types have not previously existed. This study used the World-wide Ocean Optics Database to derive a series of experimentally measured a and b values for six Jerlov water types. Using data science techniques to group measurements in time and space, over 13.5 million data points were consolidated into 53 measured values for a and b. Established models were subsequently applied to generate a complete table of absorption and scattering coefficients from 300 to 800 nm for Jerlov IB to Jerlov 5C. The analysis includes the influence of changes in the solar zenith angle and the scattering phase function. These data are recommended for use in applications where IOPs are required to describe Jerlov water types.

4.
Neurocrit Care ; 36(1): 139-147, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34244920

RESUMEN

BACKGROUND: Cerebrovascular autoregulation (CA) is a protective mechanism that enables the cerebral vasculature to automodulate tone in response to changes in cerebral perfusion pressure to ensure constant levels of cerebral blood flow (CBF) and oxygen delivery. CA can be impaired after neurological injury and contributes to secondary brain injury. In this study, we report novel impedance indices using trans-ocular brain impedance (TOBI) during controlled systemic hemorrhage and hypotension to assess CA in comparison with pressure reactivity index (PRx). METHODS: Yorkshire swine were instrumented to record intracranial pressure (ICP), mean arterial pressure (MAP), and CBF. TOBI was recorded using electrocardiographic electrodes placed on the closed eyelids. Impedance changes (dz) were recorded in response to introducing an alternating current (0.4 mA) through the electrodes. MAP, ICP, and CBF were also measured. Animals were subjected to a controlled hemorrhage to remove 30-40% of each animal's total blood volume over 25-35 min. Hemorrhage was titrated to reach an MAP of approximately 35 mm Hg and end-tidal carbon dioxide above 28 mm Hg. PRx was calculated as a moving Pearson correlation between MAP and ICP. TOBI indices were calculated as the amplitude of the respiratory-induced changes in dz. DZx was calculated as a moving Pearson correlation between dz and MAP. TOBI indices (dz and DZx) were compared with hemodynamic indicators and PRx. RESULTS: dz was shown to be highly correlated with MAP, ICP, cerebral perfusion pressure, and CBF (r = - 0.823, - 0.723, - 0.813, and - 0.726), respectively (p < 0.0001). During hemorrhage, cerebral perfusion pressure and CBF had a mean percent decrease (standard deviation) from baseline of - 54.2% (12.5%) and - 28.3% (14.7%), respectively, whereas dz increased by 277% (268%). Receiver operator characteristics and precision-recall curves demonstrated high predictive performance of DZx when compared with PRx with an area under the curve above 0.82 and 0.89 for receiver operator characteristic and precision-recall curves, respectively, with high sensitivity and positive predictive power. CONCLUSIONS: TOBI indices appear to track changes in PRx and hemodynamics that affect CA during hemorrhage-induced hypotension. TOBI may offer a suitable, less invasive surrogate to PRx for monitoring and assessing CA.


Asunto(s)
Hipotensión , Presión Intracraneal , Animales , Encéfalo , Circulación Cerebrovascular/fisiología , Impedancia Eléctrica , Homeostasis/fisiología , Presión Intracraneal/fisiología , Porcinos
5.
BMC Med Inform Decis Mak ; 22(1): 203, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35915430

RESUMEN

BACKGROUND: Traumatic Brain Injury (TBI) is a common condition with potentially severe long-term complications, the prediction of which remains challenging. Machine learning (ML) methods have been used previously to help physicians predict long-term outcomes of TBI so that appropriate treatment plans can be adopted. However, many ML techniques are "black box": it is difficult for humans to understand the decisions made by the model, with post-hoc explanations only identifying isolated relevant factors rather than combinations of factors. Moreover, such models often rely on many variables, some of which might not be available at the time of hospitalization. METHODS: In this study, we apply an interpretable neural network model based on tropical geometry to predict unfavorable outcomes at six months from hospitalization in TBI patients, based on information available at the time of admission. RESULTS: The proposed method is compared to established machine learning methods-XGBoost, Random Forest, and SVM-achieving comparable performance in terms of area under the receiver operating characteristic curve (AUC)-0.799 for the proposed method vs. 0.810 for the best black box model. Moreover, the proposed method allows for the extraction of simple, human-understandable rules that explain the model's predictions and can be used as general guidelines by clinicians to inform treatment decisions. CONCLUSIONS: The classification results for the proposed model are comparable with those of traditional ML methods. However, our model is interpretable, and it allows the extraction of intelligible rules. These rules can be used to determine relevant factors in assessing TBI outcomes and can be used in situations when not all necessary factors are known to inform the full model's decision.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Redes Neurales de la Computación , Lesiones Traumáticas del Encéfalo/diagnóstico , Lesiones Traumáticas del Encéfalo/terapia , Humanos , Aprendizaje Automático , Pronóstico , Curva ROC
6.
Neurocrit Care ; 35(3): 845-852, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34173156

RESUMEN

BACKGROUND: Sodium chloride (NaCl) 23.4% solution has been shown to reduce intracranial pressure (ICP) and reverse transtentorial herniation. A limitation of 23.4% NaCl is its high osmolarity (8008 mOsm/l) and the concern for tissue injury or necrosis following extravasation when administered via peripheral venous access. The use of this agent is therefore often limited to central venous or intraosseous routes of administration. Our objective was to evaluate the safety and efficacy of administration of 23.4% NaCl via peripheral venous access compared with administration via central venous access. METHODS: We reviewed pharmacy records to identify all administrations of 23.4% NaCl at our institution between December 2017 and February 2020. Medical records were then reviewed to identify complications, such as extravasation, soft tissue injury or necrosis, hypotension (mean arterial pressure less than 65 mm Hg), pulmonary edema, hemolysis, and osmotic demyelination. We also compared the change in physiological variables, such as ICP, mean arterial pressure, cerebral perfusion pressure, and heart rate, as well as laboratory values, such as sodium, chloride, bicarbonate, creatinine, and hemoglobin, following administration of 23.4% NaCl via the peripheral and central venous routes. RESULTS: We identified 299 administrations of 23.4% NaCl (242 central and 57 peripheral) in 141 patients during the study period. There was no documented occurrence of soft tissue injury or necrosis in any patient. One patient developed hypotension following central administration. Among the 38 patients with ICP monitoring at the time of drug administration, there was no significant difference in median ICP reduction (- 13 mm Hg [central] vs. - 24 mm Hg [peripheral], p = 0.21) or cerebral perfusion pressure augmentation (16 mm Hg [central] vs. 15 mm Hg [peripheral], p = 0.87) based on route of administration. CONCLUSIONS: Peripheral venous administration of 23.4% NaCl is safe and achieves a reduction in ICP equivalent to that achieved by administration via central venous access.


Asunto(s)
Hipertensión Intracraneal , Cloruro de Sodio , Circulación Cerebrovascular , Humanos , Hipertensión Intracraneal/etiología , Presión Intracraneal , Solución Salina Hipertónica/efectos adversos
7.
J Clin Monit Comput ; 35(5): 1007-1014, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-32666400

RESUMEN

Cerebrovascular autoregulation (CA) is often impaired following traumatic brain injury. Established technologies and metrics used to assess CA are invasive and conducive for measurement, but not for continuous monitoring. We developed a trans-ocular brain impedance (TOBI) method that may provide non-invasive and continuous indices to assess CA. In this study, we monitored impedance metrics such as respiratory-induced impedance amplitude changes (dz) as well as a novel impedance index (DZx), which is a moving Pearson correlation between mean arterial pressure (MAP) and dz. Yorkshire swine were instrumented to continuously record ICP, MAP, and cerebral blood flow (CBF). TOBI was recorded by placement of standard ECG electrodes on closed eyelids and connected to a data acquisition system. MAP, ICP and CBF were manipulated utilizing an intravenous vasopressor challenge. TOBI indices (dz and DZx) were compared to the hemodynamic indicators as well as pressure reactivity index (PRx). During the vasopressor challenge, dz was highly correlated with ICP, CPP, and CBF (r = < - 0.49, p < 0.0001). ICP, CPP, and CBF had a mean percent increase (standard deviation) from baseline of 29(23.2)%, 70(25)%, and 37(72.6)% respectively while dz decreased by 31(15.6)%. Receiver operator curve test showed high predictive performance of DZx when compared to PRx with area under the curve above 0.86, with high sensitivity and specificity. Impedance indices appear to track changes in PRx and hemodynamics that affect cerebral autoregulation. TOBI may be a suitable less invasive surrogate to PRx and capable of tracking cerebral autoregulation.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Presión Intracraneal , Animales , Presión Arterial , Encéfalo , Circulación Cerebrovascular , Impedancia Eléctrica , Homeostasis , Porcinos
8.
Neurocrit Care ; 33(2): 597-603, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32770341

RESUMEN

BACKGROUND: Many COVID-19 patients with neurological manifestations and respiratory failure remain dependent on mechanical ventilation and require tracheostomy, which is an aerosol generating procedure (AGP). The risk of SARS-CoV-2 transmission to healthcare staff during AGPs is well documented, and negative-pressure rooms are often unavailable. Innovative techniques to decrease risk to healthcare providers during AGPs are necessary. Our objective was to demonstrate the feasibility of percutaneous dilatational tracheostomy (PDT) performed using a novel prefabricated low-cost negative-pressure tent (AerosolVE). METHODS: Retrospective review of consecutive PDT procedures performed by neurointensivists on intubated adult patients with COVID-19 using the AerosolVE tent during the pandemic under an innovative clinical care protocol. The AerosolVE negative-pressure tent consists of a clear plastic canopy with slits for hand access attached to a U-shaped base with air vents. Air within the tent is drawn through a high-efficiency particulate air filter and released outside. Preliminary testing during simulated AGPs demonstrated negligible escape of particulate matter beyond the tent. The main outcome measure was successful completion of PDT and bronchoscopy within the AerosolVE tent, without complications. RESULTS: The patients were a 53-year-old man with multifocal ischemic stroke and acute respiratory distress syndrome (ARDS), 53-year-old woman with cerebellar hemorrhage and ARDS, and a 69-year-old man with ARDS. Pre-procedure FiO2 requirement was 40-50% and positive end-expiratory pressure (PEEP) 8-12 cm H2O. The tent was successfully positioned around the patient and PDT completed with real-time ultrasound guidance in all 3 patients. Bronchoscopy was performed to confirm tube position and perform pulmonary toilet. No complications occurred. CONCLUSIONS: It is feasible to perform PDT on intubated COVID-19 patients using the AerosolVE negative-pressure tent. This is a promising low-cost device to decrease risk to healthcare providers during AGPs.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/prevención & control , Infecciones por Coronavirus/transmisión , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Pandemias/prevención & control , Neumonía Viral/prevención & control , Neumonía Viral/transmisión , Equipos de Seguridad , Traqueostomía/instrumentación , Anciano , COVID-19 , Infecciones por Coronavirus/diagnóstico , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neumonía Viral/diagnóstico , Presión , SARS-CoV-2
9.
Appl Opt ; 58(29): 8108, 2019 10 10.
Artículo en Inglés | MEDLINE | ID: mdl-31674365

RESUMEN

Some measurement units have been updated in Appl. Opt.56, 8135 (2017)APOPAI0003-693510.1364/AO.56.008135.

10.
Appl Opt ; 58(13): 3354-3358, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-31044831

RESUMEN

Quantifying the coloration and luminous transmittance of eyewear filters is essential to understand their impact on human visual performance. Accurate measurements require the use of a spectrophotometer, with such equipment often being prohibitively expensive for wide-scale use. This paper details a new technique to characterize eyewear filters using only a digital camera and a sheet of white paper. Images of the paper are captured with and without the filter in front of the camera lens, and then subsequent analysis of pixel intensities allows the filter coloration and luminous transmittance to be determined. The technique has been applied to six different eyewear filters using three different camera and illumination configurations, demonstrating a reasonable match to the spectrophotometer data. This technique is suited to implementation in a smartphone app, in order to provide a low-cost and widely deployable solution to monitor the ageing of eyewear inventory.

11.
Crit Care Med ; 46(8): 1302-1308, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29742589

RESUMEN

OBJECTIVES: The postoperative management of patients who undergo brain tumor resection frequently occurs in an ICU. However, the routine admission of all patients to an ICU following surgery is controversial. This study seeks to identify the frequency with which patients undergoing elective supratentorial tumor resection require care, aside from frequent neurologic checks, that is specific to an ICU and to determine the frequency of new complications during ICU admission. Additionally, clinical predictors of ICU-specific care are identified, and a scoring system to discriminate patients most likely to require ICU-specific treatment is validated. DESIGN: Retrospective observational cohort study. SETTING: Academic neurosurgical center. PATIENTS: Two-hundred consecutive adult patients who underwent supratentorial brain tumor surgery. An additional 100 consecutive patients were used to validate the prediction score. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Univariate statistics and multivariable logistic regression were used to identify clinical characteristics associated with ICU-specific treatment. Eighteen patients (9%) received ICU-specific care, and 19 (9.5%) experienced new complications or underwent emergent imaging while in the ICU. Factors significantly associated with ICU-specific care included nonelective admission, preoperative Glasgow Coma Scale, and volume of IV fluids. A simple clinical scoring system that included Karnofsky Performance Status less than 70 (1 point), general endotracheal anesthesia (1 point), and any early postoperative complications (2 points) demonstrated excellent ability to discriminate patients who required ICU-specific care in both the derivation and validation cohorts. CONCLUSIONS: Less than 10% of patients required ICU-specific care following supratentorial tumor resection. A simple clinical scoring system may aid clinicians in stratifying the risk of requiring ICU care and could inform triage decisions when ICU bed availability is limited.


Asunto(s)
Craneotomía/estadística & datos numéricos , Unidades de Cuidados Intensivos/estadística & datos numéricos , Neoplasias Supratentoriales/cirugía , Adulto , Anciano , Femenino , Escala de Coma de Glasgow , Humanos , Estado de Ejecución de Karnofsky , Tiempo de Internación , Masculino , Persona de Mediana Edad , Gravedad del Paciente , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Factores de Riesgo
12.
Opt Express ; 26(21): 27033-27057, 2018 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-30469779

RESUMEN

This study investigates the extent to which a windscreen affects the severity of laser eye dazzle (disability glare produced by a laser) experienced by a human observer. Windscreen scatter measurements were taken for a range of windscreens in a variety of conditions, showing that windscreen scatter is similar in magnitude to scatter from the human eye. Human subject experiments verified that obscuration angles caused by laser eye dazzle could be increased by the presence of a windscreen when comparing a dirty automobile windscreen to an eye-only condition with a 532-nm laser exposure. However, a light aircraft windscreen with lower scatter did not exhibit increased obscuration angles at 532 nm, and neither windscreen exhibited an increase at 635 nm. A theoretical analysis of laser eye dazzle, using measured windscreen scatter functions, has provided insight into the delicate interplay between scatter, transmission and the angular extent of dazzle. A model based on this analysis has been shown to be a useful tool to predict the impact of windscreens on laser eye dazzle, with the goal of informing future updates to the authors' laser eye dazzle safety framework.


Asunto(s)
Automóviles , Deslumbramiento , Vidrio , Dispersión de Radiación , Trastornos de la Visión/etiología , Adulto , Humanos , Rayos Láser/efectos adversos , Luz
13.
Neurocrit Care ; 29(3): 530, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30377909

RESUMEN

The authors note that the number 14 was inadvertently omitted from the formula listed on page 5 of the article. It currently reads.

14.
Neurocrit Care ; 29(2): 280-290, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29948998

RESUMEN

BACKGROUND: Elevated intracranial pressure (ICP) is an important cause of death following acute liver failure (ALF). While invasive ICP monitoring (IICPM) is most accurate, the presence of coagulopathy increases bleeding risk in ALF. Our objective was to evaluate the accuracy of three noninvasive ultrasound-based measures for the detection of concurrent ICP elevation in ALF-optic nerve sheath diameter (ONSD) using optic nerve ultrasound (ONUS); middle cerebral artery pulsatility index (PI) on transcranial Doppler (TCD); and ICP calculated from TCD flow velocities (ICPtcd) using the estimated cerebral perfusion pressure (CPPe) technique. METHODS: In this retrospective study, consecutive ALF patients admitted over a 6-year period who underwent IICPM as well as measurement of ONSD, TCD-PI or ICPtcd were included. ONSD was measured offline by a blinded investigator from deidentified videos. The ability of highest ONSD, TCD-PI, and ICPtcd to detect concurrent invasive ICP > 20 mmHg was assessed using receiver operating characteristic (ROC) curves. The ROC area under the curve (AUC) was calculated with 95% confidence interval (95% CI) and evaluated against the null hypothesis of AUC = 0.5. Noninvasive measures were also evaluated as predictors of in-hospital death. RESULTS: Forty-one ALF patients were admitted during the study period. In total, 27 (66%) underwent IICPM, of these, 23 underwent ONUS and 21 underwent TCD. Eleven out of 23 (48%) patients died (two from intracranial hypertension). Results of ROC analysis for detection of concurrent ICP > 20 mmHg were as follows: ONSD AUC = 0.59 (95% CI 0.37-0.79, p = 0.54); TCD-PI AUC = 0.55 (95% CI 0.34-0.75, p = 0.70); and ICPtcd AUC = 0.90 (0.72-0.98, p < 0.0001). None of the noninvasive measures were significant predictors of death. CONCLUSIONS: In patients with ALF, neither ONSD nor TCD-PI reliably detected concurrent ICP elevation on invasive monitoring. Estimation of ICP (ICPtcd) using the TCD CPPe technique was associated with concurrent ICP elevation. Additional studies of TCD CPPe in larger numbers of ALF patients may prove worthwhile.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Edema Encefálico/diagnóstico , Circulación Cerebrovascular/fisiología , Hipertensión Intracraneal/diagnóstico , Presión Intracraneal/fisiología , Fallo Hepático Agudo/complicaciones , Monitorización Neurofisiológica/métodos , Nervio Óptico/diagnóstico por imagen , Ultrasonografía Doppler Transcraneal/métodos , Adulto , Edema Encefálico/etiología , Femenino , Humanos , Hipertensión Intracraneal/etiología , Masculino , Persona de Mediana Edad , Monitorización Neurofisiológica/normas , Estudios Retrospectivos , Método Simple Ciego , Ultrasonografía Doppler Transcraneal/normas , Adulto Joven
15.
Appl Opt ; 56(29): 8135-8147, 2017 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-29047676

RESUMEN

A series of experiments has been conducted to quantify the effects of laser wavelength and ambient luminance on the severity of laser eye dazzle experienced by human subjects. Eight laser wavelengths in the visible spectrum were used (458-647 nm) across a wide range of ambient luminance conditions (0.1-10,000 cd·m-2). Subjects were exposed to laser irradiance levels up to 600 µW·cm-2 and were asked to recognize the orientation of optotypes at varying eccentricities up to 31.6 deg of visual angle from the laser axis. More than 40,000 data points were collected from 14 subjects (ages 23-64), and these were consolidated into a series of obscuration angles for comparison to a theoretical model of laser eye dazzle. Scaling functions were derived to allow the model to predict the effects of laser dazzle on vision more accurately by including the effects of ambient luminance and laser wavelength. The updated model provides an improved match to observed laser eye dazzle effects across the full range of conditions assessed. The resulting model will find use in a variety of laser safety applications, including the estimation of maximum dazzle exposure and nominal ocular dazzle distance values.


Asunto(s)
Ojo/efectos de la radiación , Rayos Láser/efectos adversos , Luz , Iluminación , Modelos Biológicos , Visión Ocular/efectos de la radiación , Adulto , Humanos , Persona de Mediana Edad
17.
Appl Opt ; 55(9): 2240-51, 2016 03 20.
Artículo en Inglés | MEDLINE | ID: mdl-27140558

RESUMEN

An optical simulator of the human eye and its application to laser dazzle events are presented. The simulator combines optical design software (ZEMAX) with a scientific programming language (MATLAB) and allows the user to implement and analyze a dazzle scenario using practical, real-world parameters. Contrary to conventional analytical glare analysis, this work uses ray tracing and the scattering model and parameters for each optical element of the eye. The theoretical background of each such element is presented in relation to the model. The overall simulator's calibration, validation, and performance analysis are achieved by comparison with a simpler model based uponCIE disability glare data. Results demonstrate that this kind of advanced optical eye simulation can be used to represent laser dazzle and has the potential to extend the range of applicability of analytical models.

18.
Neurocrit Care ; 24(2): 189-96, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26209281

RESUMEN

BACKGROUND: Early detection of pulmonary edema is vital to appropriate fluid management following subarachnoid hemorrhage (SAH). Lung ultrasound (LUS) has been shown to accurately identify pulmonary edema in patients with acute respiratory failure (ARF). Our objective was to determine the accuracy of daily screening LUS for the detection of pulmonary edema following SAH. METHODS: Screening LUS was performed in conjunction with daily transcranial doppler for SAH patients within the delayed cerebral ischemia (DCI) risk period in our neuroICU. We reviewed records of SAH patients admitted 7/2012-5/2014 who underwent bilateral LUS on at least 5 consecutive days. Ultrasound videos were reviewed by an investigator blinded to the final diagnosis. "B+ lines" were defined as ≥3 B-lines on LUS. Two other investigators blinded to ultrasound results determined whether pulmonary edema with ARF (PE-ARF) was present during the period of evaluation on the basis of independent chart review, with a fourth investigator performing adjudication in the event of disagreement. The diagnostic accuracy of B+ lines for the detection of PE-ARF and RPE was determined. RESULTS: Of 59 patients meeting criteria for inclusion, 21 (36%) had PE-ARF and 26 (44%) had B+ lines. Kappa for inter-rater agreement was 0.821 (p < 0.0001) for clinical diagnosis of PE-ARF between the two investigators. B+ lines demonstrated sensitivity 90% (95% CI 70-99%) and specificity 82% (66-92%), for PE-ARF. Median days from B+ lines onset to PE-ARF was 1 (IQR 0-1). CONCLUSION: Screening LUS was a sensitive test for the detection of symptomatic pulmonary edema following SAH and may assist with fluid titration during the risk period for DCI.


Asunto(s)
Edema Pulmonar/diagnóstico por imagen , Hemorragia Subaracnoidea/complicaciones , Ultrasonografía/normas , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Edema Pulmonar/etiología , Sensibilidad y Especificidad , Hemorragia Subaracnoidea/diagnóstico por imagen
19.
Crit Care ; 19: 198, 2015 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-25925262

RESUMEN

INTRODUCTION: Recent studies have demonstrated the feasibility of real-time ultrasound guidance during percutaneous dilatational tracheostomy, including in patients with risk factors such as coagulopathy, cervical spine immobilization and morbid obesity. Use of real-time ultrasound guidance has been shown to improve the technical accuracy of percutaneous dilatational tracheostomy; however, it is unclear if there is an associated reduction in complications. Our objective was to determine whether the peri-procedural use of real-time ultrasound guidance is associated with a reduction in complications of percutaneous dilatational tracheostomy using a propensity score analysis. METHODS: This study reviewed all percutaneous dilatational tracheostomies performed in an 8-year period in a neurocritical care unit. Percutaneous dilatational tracheostomies were typically performed by trainees under guidance of the attending intensivist. Bronchoscopic guidance was used for all procedures with addition of real-time ultrasound guidance at the discretion of the attending physician. Real-time ultrasound guidance was used to guide endotracheal tube withdrawal, guide tracheal puncture, identify guidewire entry level and confirm bilateral lung sliding. The primary outcome was a composite of previously defined complications including (among others) bleeding, infection, loss of airway, inability to complete procedure, need for revision, granuloma and early dislodgement. Propensity score analysis was used to ensure that the relationship of not using real-time ultrasound guidance with the probability of an adverse outcome was examined within groups of patients having similar covariate profiles. Covariates included were age, gender, body mass index, diagnosis, Acute Physiology and Chronic Health Evaluation II score, timing of tracheostomy, positive end-expiratory pressure and presence of risk factors including coagulopathy, cervical spine immobilization and prior tracheostomy. RESULTS: A total of 200 patients underwent percutaneous dilatational tracheostomy during the specified period, and 107 received real-time ultrasound guidance. Risk factors for percutaneous dilatational tracheostomy were present in 63 (32%). There were nine complications in the group without real-time ultrasound guidance: bleeding (n = 4), need for revision related to inability to ventilate or dislodgement (n = 3) and symptomatic granuloma (n = 2). There was one complication in the real-time ultrasound guidance group (early dislodgement). The odds of having an adverse outcome for patients receiving real-time ultrasound guidance were significantly lower (odds ratio = 0.08; 95% confidence interval, 0.009 to 0.811; P = 0.032) than for those receiving a standard technique while holding the propensity score quartile fixed. CONCLUSIONS: The use of real-time ultrasound guidance during percutaneous dilatational tracheostomy was associated with a significant reduction in procedure-related complications.


Asunto(s)
Sistemas de Computación/estadística & datos numéricos , Dilatación/métodos , Complicaciones Intraoperatorias/diagnóstico por imagen , Puntaje de Propensión , Traqueostomía/métodos , Ultrasonografía Intervencional/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Dilatación/efectos adversos , Femenino , Humanos , Complicaciones Intraoperatorias/prevención & control , Intubación Intratraqueal/efectos adversos , Intubación Intratraqueal/métodos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Traqueostomía/efectos adversos
20.
Appl Opt ; 54(25): 7567-74, 2015 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-26368879

RESUMEN

An experiment has been conducted to determine the contribution of atmospheric scatter to the severity of the dazzle experienced by a human under illumination from a visible laser. A 15 W 532 nm laser was propagated over a 380 m outdoor range in San Antonio, Texas, over nine data collection sessions spanning June and July 2014. A narrow acceptance angle detector was used to measure scattered laser radiation within the laser beam at different angles from its axis. Atmospheric conditions were logged via a local weather station, and air quality data were taken from a nearby continuous air monitoring station. The measured laser irradiance data showed very little variation across the sessions and a single fitting equation was derived for the atmospheric scatter function. With very conservative estimates of the scatter from the human eye, atmospheric scatter was found to contribute no more than 5% to the overall veiling luminance across the scene for a human observer experiencing laser eye dazzle. It was concluded that atmospheric scatter does not make a significant contribution to laser eye dazzle for short-range laser engagements in atmospheres of good to moderate air quality, which account for 99.5% of conditions in San Antonio, Texas.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA