Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Magn Reson Med ; 91(6): 2579-2596, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38192108

RESUMEN

PURPOSE: This study aims to evaluate two distinct approaches for fiber radius estimation using diffusion-relaxation MRI data acquired in biomimetic microfiber phantoms that mimic hollow axons. The methods considered are the spherical mean power-law approach and a T2-based pore size estimation technique. THEORY AND METHODS: A general diffusion-relaxation theoretical model for the spherical mean signal from water molecules within a distribution of cylinders with varying radii was introduced, encompassing the evaluated models as particular cases. Additionally, a new numerical approach was presented for estimating effective radii (i.e., MRI-visible mean radii) from the ground truth radii distributions, not reliant on previous theoretical approximations and adaptable to various acquisition sequences. The ground truth radii were obtained from scanning electron microscope images. RESULTS: Both methods show a linear relationship between effective radii estimated from MRI data and ground-truth radii distributions, although some discrepancies were observed. The spherical mean power-law method overestimated fiber radii. Conversely, the T2-based method exhibited higher sensitivity to smaller fiber radii, but faced limitations in accurately estimating the radius in one particular phantom, possibly because of material-specific relaxation changes. CONCLUSION: The study demonstrates the feasibility of both techniques to predict pore sizes of hollow microfibers. The T2-based technique, unlike the spherical mean power-law method, does not demand ultra-high diffusion gradients, but requires calibration with known radius distributions. This research contributes to the ongoing development and evaluation of neuroimaging techniques for fiber radius estimation, highlights the advantages and limitations of both methods, and provides datasets for reproducible research.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Modelos Teóricos , Imagen de Difusión por Resonancia Magnética/métodos , Axones , Microscopía , Neuroimagen
2.
Small ; 19(33): e2207330, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37078831

RESUMEN

Electrospinning technology has attracted extensive attention in recent decades and is widely used to prepare nanofiber membranes from hundreds of polymers. Polyvinyl formal acetal (PVFA), as a polymer with excellent properties such as high strength and heat resistance, is not reported on the electrospun water treatment membrane. In this paper, the preparation process of electrospun PVFA nanofiber membrane is optimized, and the effect of sodium chloride (NaCl) addition on the physical and mechanical properties and microfiltration performance of nanofiber membrane is also explored. And the hydrophobic PVFA nanofiber filter layer is then combined with a hydrophilic nonwoven support layer to construct a composite micro/nanofiber membrane with a pore-size gradient structure and a hydrophilic/hydrophobic asymmetric structure. Finally, unidirectional water transport and water treatment performance are further investigated. The results show that the tensile breaking strength of the composite membrane can reach up to 37.8 MPa, the retention rate for particles with the size of 0.1-0.3 µm is 99.7%, and the water flux is 513.4 L m-2 h-1 under the hydrostatic pressure. Moreover, it still has a retention of more than 98% after three repeated uses. Therefore, the electrospun PVFA composite membrane has a great potential in microfiltration.

3.
Magn Reson Med ; 90(1): 150-165, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36941736

RESUMEN

PURPOSE: Tensor-valued diffusion encoding can probe more specific features of tissue microstructure than what is available by conventional diffusion weighting. In this work, we investigate the technical feasibility of tensor-valued diffusion encoding at high b-values with q-space trajectory imaging (QTI) analysis, in the human heart in vivo. METHODS: Ten healthy volunteers were scanned on a 3T scanner. We designed time-optimal gradient waveforms for tensor-valued diffusion encoding (linear and planar) with second-order motion compensation. Data were analyzed with QTI. Normal values and repeatability were investigated for the mean diffusivity (MD), fractional anisotropy (FA), microscopic FA (µFA), isotropic, anisotropic and total mean kurtosis (MKi, MKa, and MKt), and orientation coherence (Cc ). A phantom, consisting of two fiber blocks at adjustable angles, was used to evaluate sensitivity of parameters to orientation dispersion and diffusion time. RESULTS: QTI data in the left ventricular myocardium were MD = 1.62 ± 0.07 µm2 /ms, FA = 0.31 ± 0.03, µFA = 0.43 ± 0.07, MKa = 0.20 ± 0.07, MKi = 0.13 ± 0.03, MKt = 0.33 ± 0.09, and Cc  = 0.56 ± 0.22 (mean ± SD across subjects). Phantom experiments showed that FA depends on orientation dispersion, whereas µFA was insensitive to this effect. CONCLUSION: We demonstrated the first tensor-valued diffusion encoding and QTI analysis in the heart in vivo, along with first measurements of myocardial µFA, MKi, MKa, and Cc . The methodology is technically feasible and provides promising novel biomarkers for myocardial tissue characterization.


Asunto(s)
Imagen de Difusión Tensora , Corazón , Humanos , Imagen de Difusión Tensora/métodos , Corazón/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Miocardio , Ventrículos Cardíacos , Anisotropía
4.
Neuroimage ; 242: 118445, 2021 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-34375753

RESUMEN

Microscopic diffusion anisotropy imaging using diffusion-weighted MRI and multidimensional diffusion encoding is a promising method for quantifying clinically and scientifically relevant microstructural properties of neural tissue. Several methods for estimating microscopic fractional anisotropy (µFA), a normalized measure of microscopic diffusion anisotropy, have been introduced but the differences between the methods have received little attention thus far. In this study, the accuracy and precision of µFA estimation using q-space trajectory encoding and different signal models were assessed using imaging experiments and simulations. Three healthy volunteers and a microfibre phantom were imaged with five non-zero b-values and gradient waveforms encoding linear and spherical b-tensors. Since the ground-truth µFA was unknown in the imaging experiments, Monte Carlo random walk simulations were performed using axon-mimicking fibres for which the ground truth was known. Furthermore, parameter bias due to time-dependent diffusion was quantified by repeating the simulations with tuned waveforms, which have similar power spectra, and with triple diffusion encoding, which, unlike q-space trajectory encoding, is not based on the assumption of time-independent diffusion. The truncated cumulant expansion of the powder-averaged signal, gamma-distributed diffusivities assumption, and q-space trajectory imaging, a generalization of the truncated cumulant expansion to individual signals, were used to estimate µFA. The gamma-distributed diffusivities assumption consistently resulted in greater µFA values than the second order cumulant expansion, 0.1 greater when averaged over the whole brain. In the simulations, the generalized cumulant expansion provided the most accurate estimates. Importantly, although time-dependent diffusion caused significant overestimation of µFA using all the studied methods, the simulations suggest that the resulting bias in µFA is less than 0.1 in human white matter.


Asunto(s)
Anisotropía , Encéfalo/diagnóstico por imagen , Imagen de Difusión Tensora/instrumentación , Adulto , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/instrumentación , Masculino , Método de Montecarlo , Fantasmas de Imagen , Sustancia Blanca/diagnóstico por imagen
5.
Magn Reson Med ; 86(3): 1514-1530, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33960501

RESUMEN

PURPOSE: Recent advances in diffusion-weighted MRI provide "restricted diffusion signal fraction" and restricting pore size estimates. Materials based on co-electrospun oriented hollow cylinders have been introduced to provide validation for such methods. This study extends this work, exploring accuracy and repeatability using an extended acquisition on a 300 mT/m gradient human MRI scanner, in substrates closely mimicking tissue, that is, non-circular cross-sections, intra-voxel fiber crossing, intra-voxel distributions of pore-sizes, and smaller pore-sizes overall. METHODS: In a single-blind experiment, diffusion-weighted data were collected from a biomimetic phantom on a 3T Connectom system using multiple gradient directions/diffusion times. Repeated scans established short-term and long-term repeatability. The total scan time (54 min) matched similar protocols used in human studies. The number of distinct fiber populations was estimated using spherical deconvolution, and median pore size estimated through the combination of CHARMED and AxCaliber3D framework. Diffusion-based estimates were compared with measurements derived from scanning electron microscopy. RESULTS: The phantom contained substrates with different orientations, fiber configurations, and pore size distributions. Irrespective of one or two populations within the voxel, the pore-size estimates (~5 µm) and orientation-estimates showed excellent agreement with the median values of pore-size derived from scanning electron microscope and phantom configuration. Measurement repeatability depended on substrate complexity, with lower values seen in samples containing crossing-fibers. Sample-level repeatability was found to be good. CONCLUSION: While no phantom mimics tissue completely, this study takes a step closer to validating diffusion microstructure measurements for use in vivo by demonstrating the ability to quantify microgeometry in relatively complex configurations.


Asunto(s)
Biomimética , Imagen de Difusión por Resonancia Magnética , Encéfalo , Humanos , Microscopía Electrónica de Rastreo , Fantasmas de Imagen , Método Simple Ciego
6.
Neuroimage ; 181: 395-402, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29936312

RESUMEN

Grey and white matter mimicking phantoms are important for assessing variations in diffusion MR measures at a single time point and over an extended period of time. This work investigates the stability of brain-mimicking microfibre phantoms and reproducibility of their MR derived diffusion parameters. The microfibres were produced by co-electrospinning and characterized by scanning electron microscopy (SEM). Grey matter and white matter phantoms were constructed from random and aligned microfibres, respectively. MR data were acquired from these phantoms over a period of 33 months. SEM images revealed that only small changes in fibre microstructure occurred over 30 months. The coefficient of variation in MR measurements across all time-points was between 1.6% and 3.4% for MD across all phantoms and FA in white matter phantoms. This was within the limits expected for intra-scanner variability, thereby confirming phantom stability over 33 months. These specialised diffusion phantoms may be used in a clinical environment for intra and inter-site quality assurance purposes, and for validation of quantitative diffusion biomarkers.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/normas , Sustancia Gris/diagnóstico por imagen , Microscopía Electrónica de Rastreo , Fantasmas de Imagen/normas , Sustancia Blanca/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Control de Calidad , Reproducibilidad de los Resultados , Factores de Tiempo
7.
Magn Reson Med ; 80(1): 147-158, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29154442

RESUMEN

PURPOSE: To develop a biomimetic tumor tissue phantom which more closely reflects water diffusion in biological tissue than previously used phantoms, and to evaluate the stability of the phantom and its potential as a tool for validating diffusion-weighted (DW) MRI measurements. METHODS: Coaxial-electrospraying was used to generate micron-sized hollow polymer spheres, which mimic cells. The bulk structure was immersed in water, providing a DW-MRI phantom whose apparent diffusion coefficient (ADC) and microstructural properties were evaluated over a period of 10 months. Independent characterization of the phantom's microstructure was performed using scanning electron microscopy (SEM). The repeatability of the construction process was investigated by generating a second phantom, which underwent high resolution synchrotron-CT as well as SEM and MR scans. RESULTS: ADC values were stable (coefficients of variation (CoVs) < 5%), and varied with diffusion time, with average values of 1.44 ± 0.03 µm2 /ms (Δ = 12 ms) and 1.20 ± 0.05 µm2 /ms (Δ = 45 ms). Microstructural parameters showed greater variability (CoVs up to 13%), with evidence of bias in sphere size estimates. Similar trends were observed in the second phantom. CONCLUSION: A novel biomimetic phantom has been developed and shown to be stable over 10 months. It is envisaged that such phantoms will be used for further investigation of microstructural models relevant to characterizing tumor tissue, and may also find application in evaluating acquisition protocols and comparing DW-MRI-derived biomarkers obtained from different scanners at different sites. Magn Reson Med 80:147-158, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Asunto(s)
Biomimética , Imagen de Difusión por Resonancia Magnética , Neoplasias/diagnóstico por imagen , Fantasmas de Imagen , Algoritmos , Biomarcadores , Electroquímica , Diseño de Equipo , Humanos , Funciones de Verosimilitud , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Polímeros , Sincrotrones , Tomografía Computarizada por Rayos X , Agua
8.
Biotechnol Lett ; 40(2): 279-284, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29119355

RESUMEN

OBJECTIVES: To create a multifunctional medical material that combines the advantages of both nanofibers and macroyarns. RESULTS: A novel electrospinning-based approach was developed for creating polycaprolactone (PCL) nanofiber covered yarns (PCL-NCYs) in which polyglycolic acid multi-strand filaments (PGA-MFs) were used as the core. BALB/3T3 (mouse embryonic fibroblast cell line) cells were cultured on the PCL-NCYs substrate and cell morphology and proliferation were determined by methylthiazol tetrazolium (MTT) assay. Compared with PGA-MFs, PCL-NCYs had a higher porosity and tensile strength of 88 ± 8% and 348 ± 16 MPa and in particular, the porosity was four times higher. BALB/3T3 cells attached more easily onto the nanofiber structure and proliferated along the direction of nanofibers, indicating that PCL-NCYs can achieve better cell differentiation and proliferation. CONCLUSIONS: PCL-NCYs can be created by combining electrospinning covering and textile twisting, and have better mechanical property and higher porosity, and can be used as a novel scaffold in tissue engineering.


Asunto(s)
Materiales Biocompatibles , Técnicas Electroquímicas/métodos , Animales , Células 3T3 BALB , Materiales Biocompatibles/síntesis química , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Técnicas de Cultivo de Célula , Línea Celular , Proliferación Celular/efectos de los fármacos , Forma de la Célula/efectos de los fármacos , Técnicas Electroquímicas/instrumentación , Diseño de Equipo , Ratones , Nanofibras/química , Poliésteres/química , Ácido Poliglicólico/química , Porosidad , Andamios del Tejido/química
9.
Mater Des ; 137: 394-403, 2018 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-29307950

RESUMEN

Highly hydrophilic hollow polycaprolactone (PCL) microfibres were developed as building elements to create tissue-mimicking test objects (phantoms) for validation of diffusion magnetic resonance imaging (MRI). These microfibres were fabricated by the co-electrospinning of PCL-polysiloxane-based surfactant (PSi) mixture as shell and polyethylene oxide as core. The addition of PSi had a significant effect on the size of resultant electrospun fibres and the formation of hollow microfibres. The presence of PSi in both co-electrospun PCL microfibre surface and cross-section, revealed by X-ray energy dispersive spectroscopy (EDX), enabled water to wet these fibres completely (i.e., zero contact angle) and remained active for up to 12 months after immersing in water. PCL and PCL-PSi fibres with uniaxial orientation were constructed into water-filled phantoms. MR measurement revealed that water molecules diffuse anisotropically in the PCL-PSi phantom. Co-electrospun hollow PCL-PSi microfibres have desirable hydrophilic properties for the construction of a new generation of tissue-mimicking dMRI phantoms.

10.
Langmuir ; 33(46): 13262-13271, 2017 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-28901145

RESUMEN

We describe the co-electrospraying of hollow microspheres from a polycaprolactone (PCL) shell solution and various core solutions including water, cyclohexane, poly(ethylene oxide) (PEO), and polyethylene glycol (PEG), using different collectors. The morphologies of the resultant microspheres were characterized by scanning electron microscopy (SEM), confocal microscopy, and nano-X-ray computed tomography (nano-XCT). The core/shell solution miscibility played an important role in the co-electrospraying process and the formation of microsphere structures. Spherical particles were more likely to be produced from miscible combinations of core/shell solutions than from immiscible ones. Hollow PCL microspheres with a single hole in their surfaces were produced when an ethanol bath was used as the collector. The mechanism by which the core/shell structure is transformed into single-hole hollow microspheres is proposed to be primarily based on the evaporation through the shell and extraction by ethanol of the core solution and is described in detail. Additionally, we present a 3D macroscopic tubular structure composed of hollow PCL microspheres, directly assembled on a copper wire collector during co-electrospraying. SEM and nano-XCT confirm that microspheres in the 3D bulk structure remain hollow.

11.
J Magn Reson Imaging ; 43(3): 594-600, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26213152

RESUMEN

PURPOSE: Diffusion magnetic resonance imaging (MRI) is increasingly used to characterize cardiac tissue microstructure, necessitating the use of physiologically relevant phantoms for methods development. Existing phantoms are generally simplistic and mostly simulate diffusion in the brain. Thus, there is a need for phantoms mimicking diffusion in cardiac tissue. MATERIALS AND METHODS: A biomimetic phantom composed of hollow microfibers generated using co-electrospinning was developed to mimic myocardial diffusion properties and fiber and sheet orientations. Diffusion tensor imaging was carried out at monthly intervals over 4 months at 9.4T. 3D fiber tracking was performed using the phantom and compared with fiber tracking in an ex vivo rat heart. RESULTS: The mean apparent diffusion coefficient and fractional anisotropy of the phantom remained stable over the 4-month period, with mean values of 7.53 ± 0.16 × 10(-4) mm(2) /s and 0.388 ± 0.007, respectively. Fiber tracking of the 1st and 3rd eigenvectors generated analogous results to the fiber and sheet-normal direction respectively, found in the left ventricular myocardium. CONCLUSION: A biomimetic phantom simulating diffusion in the heart was designed and built. This could aid development and validation of novel diffusion MRI methods for investigating cardiac microstructure, decrease the number of animals and patients needed for methods development, and improve quality control in longitudinal and multicenter cardiac diffusion MRI studies.


Asunto(s)
Biomimética , Imagen de Difusión por Resonancia Magnética , Imagen de Difusión Tensora , Corazón/diagnóstico por imagen , Miocardio/patología , Fantasmas de Imagen , Animales , Anisotropía , Encéfalo , Diseño de Equipo , Ventrículos Cardíacos/patología , Microscopía Electrónica de Rastreo , Ratas
12.
Magn Reson Med ; 73(1): 299-305, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24469863

RESUMEN

PURPOSE: A range of advanced diffusion MRI (dMRI) techniques are currently in development which characterize the orientation of white matter fibers using diffusion tensor imaging (DTI). There is a need for a physical phantom with microstructural features of the brain's white matter to help validate these methods. METHODS: Hollow, co-electrospun, aligned fibers with a tuneable size distribution have been produced in bulk and with an MR visible solvent infused into the pores. The morphology and size of the phantoms was assessed using scanning electron microscopy (SEM) and compared with DTI results obtained on both a clinical and preclinical scanner. RESULTS: By varying inner diameter of the phantom fibers (from SEM: 9.5 µm, 11.9 µm, 13.4 µm) the radial diffusivity and fractional anisotropy, calculated from DTI, vary between 0.38 ± 0.05 × 10(3) and 0.61 ± 0.06 × 10(3) cm s(-1) and between 0.45 ± 0.05 and 0.33 ± 0.04, respectively. CONCLUSION: We envisage that these materials will be used for the validation of novel and established methods within the field of diffusion MRI, as well as for routine quality assurance purposes and for establishing scanner performance in multicenter trials.


Asunto(s)
Materiales Biomiméticos , Encéfalo/anatomía & histología , Imagen de Difusión Tensora/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Fantasmas de Imagen , Sustancia Blanca/anatomía & histología , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
Mater Charact ; 109: 25-35, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26702249

RESUMEN

The development of co-electrospun (co-ES) hollow microfibrous assemblies of an appreciable thickness is critical for many practical applications, including filtration membranes and tissue-mimicking scaffolds. In this study, thick uniaxially aligned hollow microfibrous assemblies forming fiber bundles and strips were prepared by co-ES of polycaprolactone (PCL) and polyethylene oxide (PEO) as shell and core materials, respectively. Hollow microfiber bundles were deposited on a fixed rotating disc, which resulted in non-controllable cross-sectional shapes on a macroscopic scale. In comparison, fiber strips were produced with tuneable thickness and width by additionally employing an x-y translation stage in co-ES. Scanning electron microscopy (SEM) images of cross-sections of fiber assemblies were analyzed to investigate the effects of production time (from 0.5 h to 12 h), core flow rate (from 0.8 mL/h to 2.0 mL/h) and/or translation speed (from 0.2 mm/s to 5 mm/s) on the pores and porosity. We observed significant changes in pore size and shape with core flow rate but the influence of production time varied; five strips produced under the same conditions had reasonably good size and porosity reproducibility; pore sizes didn't vary significantly from strip bottom to surface, although the porosity gradually decreased and then returned to the initial level.

14.
Int J Biol Macromol ; 274(Pt 1): 133269, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38906353

RESUMEN

In order to fulfill the demands for degradability, a broad working range, and heightened sensitivity in flexible sensors, biodegradable polyurethane (BTPU) was synthesized and combined with CNTs to produce BTPU/CNTs coated cotton fabric using an ultrasonic-assisted inkjet printing process. The synthesized BTPU displayed a capacity for degradation in a phosphate buffered saline solution, resulting in a weight loss of 25 % after 12 weeks of degradation. The BTPU/CNTs coated cotton fabric sensor achieved an extensive strain sensing range of 0-137.5 %, characterized by high linearity and a notable sensitivity (gauge factor (GF) of 126.8). Notably, it demonstrated a low strain detection limit (1 %), rapid response (within 280 ms), and robust durability, enabling precise monitoring of both large and subtle human body movements such as finger, wrist, neck, and knee bending, as well as swallowing. Moreover, the BTPU/CNTs coated cotton fabric exhibited favorable biocompatibility with human epidermis, enabling potential applications as wearable skin-contact sensors. This work provides insight into the development of degradable and high sensing performance sensors suitable for applications in electronic skins and health monitoring devices.

15.
Neuroimage ; 80: 273-82, 2013 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-23727318

RESUMEN

In recent years, diffusion MRI has become an extremely important tool for studying the morphology of living brain tissue, as it provides unique insights into both its macrostructure and microstructure. Recent applications of diffusion MRI aimed to characterize the structural connectome using tractography to infer connectivity between brain regions. In parallel to the development of tractography, additional diffusion MRI based frameworks (CHARMED, AxCaliber, ActiveAx) were developed enabling the extraction of a multitude of micro-structural parameters (axon diameter distribution, mean axonal diameter and axonal density). This unique insight into both tissue microstructure and connectivity has enormous potential value in understanding the structure and organization of the brain as well as providing unique insights to abnormalities that underpin disease states. The CONNECT (Consortium Of Neuroimagers for the Non-invasive Exploration of brain Connectivity and Tracts) project aimed to combine tractography and micro-structural measures of the living human brain in order to obtain a better estimate of the connectome, while also striving to extend validation of these measurements. This paper summarizes the project and describes the perspective of using micro-structural measures to study the connectome.


Asunto(s)
Encéfalo/citología , Encéfalo/fisiología , Conectoma/métodos , Imagen de Difusión Tensora/métodos , Aumento de la Imagen/métodos , Red Nerviosa/citología , Red Nerviosa/fisiología , Humanos , Modelos Anatómicos , Modelos Neurológicos
16.
Polymers (Basel) ; 15(3)2023 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-36772042

RESUMEN

In the field of water purification, membrane separation technology plays a significant role. Electrospinning has emerged as a primary method to produce nanofiber membranes due to its straightforward, low cost, functional diversity, and process controllability. It is possible to flexibly control the structural characteristics of electrospun nanofiber membranes as well as carry out various membrane material combinations to make full use of their various properties, including high porosity, high selectivity, and microporous permeability to obtain high-performance water treatment membranes. These water separation membranes can satisfy the fast and efficient purification requirements in different water purification applications due to their high filtration efficiency. The current research on water treatment membranes is still focused on creating high-permeability membranes with outstanding selectivity, remarkable antifouling performance, superior physical and chemical performance, and long-term stability. This paper reviewed the preparation methods and properties of electrospun nanofiber membranes for water treatment in various fields, including microfiltration, ultrafiltration, nanofiltration, reverse osmosis, forward osmosis, and other special applications. Lastly, various antifouling technologies and research progress of water treatment membranes were discussed, and the future development direction of electrospun nanofiber membranes for water treatment was also presented.

17.
Nanoscale Adv ; 5(4): 1043-1059, 2023 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-36798499

RESUMEN

Polyvinylidene fluoride (PVDF) has been considered as a promising piezoelectric material for advanced sensing and energy storage systems because of its high dielectric constant and good electroactive response. Electrospinning is a straightforward, low cost, and scalable technology that can be used to create PVDF-based nanofibers with outstanding piezoelectric characteristics. Herein, we summarize the state-of-the-art progress on the use of filler doping and structural design to enhance the output performance of electrospun PVDF-based piezoelectric fiber films. We divide the fillers into single filler and double fillers and make comments on the effects of various dopant materials on the performance and the underlying mechanism of the PVDF-based piezoelectric fiber film. The effects of highly oriented structures, core-shell structures, and multilayer composite structures on the output properties of PVDF-based piezoelectric nanofibers are discussed in detail. Furthermore, the perspectives and opportunities for PVDF piezoelectric nanofibers in the fields of health care, environmental monitoring, and energy collection are also discussed.

18.
ACS Appl Mater Interfaces ; 15(25): 30849-30858, 2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37326608

RESUMEN

With the rapid development of the economy and technology, intelligent wearable devices have gradually entered public life. Flexible sensors, as the main component of wearable devices, have been widely concerned. However, traditional flexible sensors need an external power supply, lacking flexibility and sustainable power supply. In this study, structured poly(vinylidene fluoride) (PVDF)-based composite nanofiber membranes doped with different mass fractions of MXene and zinc oxide (ZnO) were prepared by electrospinning and were then assembled to flexible self-powered friction piezoelectric sensors. The addition of MXene and ZnO endowed PVDF nanofiber membranes with better piezoelectric properties. The structured PVDF/MXene-PVDF/ZnO (PM/PZ) nanofiber membranes with a double-layer structure, interpenetrating structure, or core-shell structure could further enhance the piezoelectric properties of PVDF-based nanofiber membranes through the synergistic effects of filler doping and structural design. In particular, the output voltage of the self-powered friction piezoelectric sensor made of a core-shell PM/PZ nanofiber membrane showed a good linear relationship with the applied pressure and could produce a good piezoelectric response to the bending deformation caused by human motion.

19.
Polym Adv Technol ; 34(8): 2573-2584, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38505514

RESUMEN

Hollow polymer microfibers with variable microstructural and hydrophilic properties were proposed as building elements to create axon-mimicking phantoms for validation of diffusion tensor imaging (DTI). The axon-mimicking microfibers were fabricated in a mm-thick 3D anisotropic fiber strip, by direct jet coaxial electrospinning of PCL/polysiloxane-based surfactant (PSi) mixture as shell and polyethylene oxide (PEO) as core. Hydrophilic PCL-PSi fiber strips were first obtained by carefully selecting appropriate solvents for the core and appropriate fiber collector rotating and transverse speeds. The porous cross-section and anisotropic orientation of axon-mimicking fibers were then quantitatively evaluated using two ImageJ plugins-nearest distance (ND) and directionality based on their scanning electron microscopy (SEM) images. Third, axon-mimicking phantom was constructed from PCL-PSi fiber strips with variable porous-section and fiber orientation and tested on a 3T clinical MR scanner. The relationship between DTI measurements (mean diffusivity [MD] and fractional anisotropy [FA]) of phantom samples and their pore size and fiber orientation was investigated. Two key microstructural parameters of axon-mimicking phantoms including normalized pore distance and dispersion of fiber orientation could well interpret the variations in DTI measurements. Two PCL-PSi phantom samples made from different regions of the same fiber strips were found to have similar MD and FA values, indicating that the direct jet coaxial electrospun fiber strips had consistent microstructure. More importantly, the MD and FA values of the developed axon-mimicking phantoms were mostly in the biologically relevant range.

20.
J Funct Biomater ; 13(2)2022 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-35645266

RESUMEN

Peripheral nerve injury (PNI) is a neurological disorder that causes more than 9 million patients to suffer from dysfunction of moving and sensing. Using biodegradable polymers to fabricate an artificial nerve conduit that replicates the environment of the extracellular matrix and guides neuron regeneration through the damaged sites has been researched for decades and has led to promising but primarily pre-clinical outcomes. However, few peripheral nerve conduits (PNCs) have been constructed from controllable biodegradable polymeric materials that can maintain their structural integrity or completely degrade during and after nerve regeneration respectively. In this work, a novel PNC candidate material was developed via the electrospinning of polyhydroxy butyrate/chitosan (PHB/CS) composite polymers. An SEM characterisation revealed the resultant PHB/CS nanofibres with 0, 1 and 2 wt/v% CS had less and smaller beads than the nanofibres at 3 wt/v% CS. The water contact angle (WCA) measurement demonstrated that the wettability of PHB/CS electrospun fibres was significantly improved by additional CS. Furthermore, both the thermogravimetric analysis (TGA) and differentiation scanning calorimetry (DSC) results showed that PHB/CS polymers can be blended in a single phase with a trifluoracetic solvent in all compositions. Besides, the reduction in the degradation temperature (from 286.9 to 229.9 °C) and crystallinity (from 81.0% to 52.1%) with increasing contents of CS were further proven. Moreover, we found that the degradability of the PHB/CS nanofibres subjected to different pH values rated in the order of acidic > alkaline > phosphate buffer solution (PBS). Based on these findings, it can be concluded that PHB/CS electrospun fibres with variable blending ratios may be used for designing PNCs with controlled biodegradability.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA