RESUMEN
This study investigated the thyroidal response to administration of recombinant human thyroid stimulating hormone (rhTSH) by means of serum total thyroxine (TT(4)) concentration and pertechnetate uptake by the thyroid gland in six healthy euthyroid spayed female cats. A pertechnetate scan was performed on day 1 to calculate thyroid/salivary gland (T/S) uptake ratio. On day 3, 25 microg rhTSH was injected intravenously. Six hours later the thyroid scan was repeated as on day 1. Blood was drawn for serum TT(4) measurement prior to injection of rhTSH and performance of the pertechnetate scan. Statistically significant differences in mean serum TT(4) concentration, T/S uptake ratio before and 6h after rhTSH administration and T/S uptake ratio between left and right lobes were noted. We can conclude that 25 microg rhTSH increases pertechnetate uptake in the thyroid glands of cats, this should be taken into account when thyroid scintigraphy after rhTSH administration is interpreted.
Asunto(s)
Gatos/sangre , Proteínas Recombinantes/farmacocinética , Pertecnetato de Sodio Tc 99m/farmacología , Glándula Tiroides/efectos de los fármacos , Tirotropina/farmacocinética , Tiroxina/sangre , Animales , Enfermedades de los Gatos/sangre , Enfermedades de los Gatos/diagnóstico , Femenino , Hipotiroidismo/sangre , Hipotiroidismo/diagnóstico , Hipotiroidismo/veterinaria , Cintigrafía/métodos , Cintigrafía/veterinaria , Proteínas Recombinantes/administración & dosificación , Glándula Tiroides/fisiología , Tirotropina/administración & dosificación , Factores de TiempoRESUMEN
This study investigated the recombinant human thyrotropin (rhTSH) stimulation test in healthy cats (group 1), cats with non-thyroidal illness (group 2) and cats with low serum total T(4) (TT(4)) and azotaemia after (131)I treatment (group 3). Serum TT(4) responses and thyroidal pertechnetate uptake after administration of 25 microg rhTSH IV were assessed. Baseline serum TT(4) was significantly lower in group 3 compared with group 1, but not between other group pairs. Serum TT(4) increased significantly in groups 1 and 2 but not in group 3 after rhTSH administration. Post-rhTSH serum TT(4) concentrations differed significantly between groups 1 and 3 and groups 2 and 3, but not between groups 1 and 2. Thyroid/salivary gland uptake ratio (T/S uptake ratio) differed only significantly between groups 1 and 3. Stimulation with rhTSH is valuable to differentiate euthyroidism from iatrogenic hypothyroidism in cats.
Asunto(s)
Azotemia/veterinaria , Hipertiroidismo/veterinaria , Glándula Tiroides/fisiología , Tirotropina/farmacología , Tiroxina/sangre , Animales , Azotemia/sangre , Azotemia/diagnóstico , Azotemia/diagnóstico por imagen , Estudios de Casos y Controles , Enfermedades de los Gatos/sangre , Enfermedades de los Gatos/diagnóstico , Enfermedades de los Gatos/diagnóstico por imagen , Gatos , Diagnóstico Diferencial , Femenino , Hipertiroidismo/sangre , Hipertiroidismo/diagnóstico por imagen , Hipertiroidismo/tratamiento farmacológico , Hipotiroidismo/sangre , Hipotiroidismo/diagnóstico , Hipotiroidismo/diagnóstico por imagen , Hipotiroidismo/veterinaria , Radioisótopos de Yodo/uso terapéutico , Cintigrafía/veterinaria , Proteínas Recombinantes/farmacología , Pertecnetato de Sodio Tc 99m , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/efectos de los fármacosRESUMEN
Estimation of the glomerular filtration rate (GFR) is a useful tool in the evaluation of kidney function in feline medicine. GFR can be determined by measuring the rate of tracer disappearance from the blood, and although these measurements are generally performed by multi-sampling techniques, simplified methods are more convenient in clinical practice. The optimal times for a simplified sampling strategy with two blood samples (2BS) for GFR measurement in cats using plasma (51)chromium ethylene diamine tetra-acetic acid ((51)Cr-EDTA) clearance were investigated. After intravenous administration of (51)Cr-EDTA, seven blood samples were obtained in 46 cats (19 euthyroid and 27 hyperthyroid cats, none with previously diagnosed chronic kidney disease (CKD)). The plasma clearance was then calculated from the seven point blood kinetics (7BS) and used for comparison to define the optimal sampling strategy by correlating different pairs of time points to the reference method. Mean GFR estimation for the reference method was 3.7+/-2.5 ml/min/kg (mean+/-standard deviation (SD)). Several pairs of sampling times were highly correlated with this reference method (r(2) > or = 0.980), with the best results when the first sample was taken 30 min after tracer injection and the second sample between 198 and 222 min after injection; or with the first sample at 36 min and the second at 234 or 240 min (r(2) for both combinations=0.984). Because of the similarity of GFR values obtained with the 2BS method in comparison to the values obtained with the 7BS reference method, the simplified method may offer an alternative for GFR estimation. Although a wide range of GFR values was found in the included group of cats, the applicability should be confirmed in cats suspected of renal disease and with confirmed CKD. Furthermore, although no indications of age-related effect were found in this study, a possible influence of age should be included in future studies.
Asunto(s)
Radioisótopos de Cromo/farmacocinética , Ácido Edético/farmacocinética , Tasa de Filtración Glomerular/veterinaria , Animales , Enfermedades de los Gatos/sangre , Enfermedades de los Gatos/diagnóstico , Gatos , Radioisótopos de Cromo/sangre , Ácido Edético/sangre , Femenino , Enfermedades Renales/sangre , Enfermedades Renales/diagnóstico , Enfermedades Renales/veterinaria , Pruebas de Función Renal/métodos , Pruebas de Función Renal/veterinaria , Masculino , Tasa de Depuración Metabólica , Factores de TiempoRESUMEN
The study investigated plasma clearance of exogenous creatinine (PECCT), exo-iohexol (PexICT) and endo-iohexol (PenICT) in six healthy cats, four cats with chronic kidney disease (CKD) and six hyperthyroid (HT) cats to assess potential differences in glomerular filtration rate (GFR) measurement over a wide range of GFR values. The PECCT, PexICT and PenICT were performed in a combined protocol. There was a significant difference between PexICT and PenICT and PECCT in healthy cats. Differences between clearance techniques are suggested to be correlated to range in GFRs and should be taken into account when GFR is measured.