Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
PLoS One ; 14(6): e0218784, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31226142

RESUMEN

OBJECTIVE: Pulse transit time (PTT) refers to the time it takes a pulse wave to travel between two arterial sites. PTT can be estimated, amongst others, using the electrocardiogram (ECG) and photoplethysmogram (PPG). Because we observed a sawtooth artifact in the PTT while using standard patient monitoring equipment for ECG and PPG, we explored the reasons for this artifact. METHODS: PPG and ECG were simulated at a heartrate of both 100 and 160 beats per minute while using a Masimo PPG post-processing module and a Philips patient monitor setup at the neonatal intensive care unit. Two different post-processing modules were used. PTT was defined as the difference between the R-peak in the ECG and the point of 50% increase in the PPG. RESULTS: A sawtooth artifact was seen in all simulations. Both length (59.2 to 72.4 s) and amplitude (30.8 to 36.0 ms) of the sawtooth were dependent on the post-processing module used. Furthermore, the absolute PTT value differed up to 250 ms depending on post-processing module and heart rate. The sawtooth occurred because the PPG wave continuously showed a minimal prolongation during the length of the sawtooth, followed by a sudden shortening. Both artifacts were generated in the post-processing module containing Masimo algorithms. CONCLUSION: Post-processing of the PPG signal in the Masimo module of the Philips patient monitor introduces a sawtooth in PPG and derived PTT. This sawtooth, together with a large module-dependent absolute difference in PTT, renders the thus-derived PTT insufficient for clinical purposes.


Asunto(s)
Artefactos , Electrocardiografía/instrumentación , Monitoreo Fisiológico , Fotopletismografía/instrumentación , Análisis de la Onda del Pulso , Algoritmos , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/instrumentación , Determinación de la Presión Sanguínea/normas , Simulación por Computador , Electrocardiografía/normas , Frecuencia Cardíaca/fisiología , Humanos , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/normas , Fotopletismografía/normas , Análisis de la Onda del Pulso/instrumentación , Análisis de la Onda del Pulso/métodos , Análisis de la Onda del Pulso/normas , Estándares de Referencia , Procesamiento de Señales Asistido por Computador/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA