1.
Sensors (Basel) ; 23(8)2023 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-37112490

RESUMEN

Traditional cuff-based sphygmomanometers for measuring blood pressure can be uncomfortable and particularly unsuitable to use during sleep. A proposed alternative method uses dynamic changes in the pulse waveform over short intervals and replaces calibration with information from photoplethysmogram (PPG) morphology to provide a calibration-free approach using a single sensor. Results from 30 patients show a high correlation of 73.64% for systolic blood pressure (SBP) and 77.72% for diastolic blood pressure (DBP) between blood pressure estimated with the PPG morphology features and the calibration method. This suggests that the PPG morphology features could replace the calibration stage for a calibration-free method with similar accuracy. Applying the proposed methodology on 200 patients and testing on 25 new patients resulted in a mean error (ME) of -0.31 mmHg, a standard deviation of error (SDE) of 4.89 mmHg, a mean absolute error (MAE) of 3.32 mmHg for DBP and an ME of -4.02 mmHg, an SDE of 10.40 mmHg, and an MAE of 7.41 mmHg for SBP. These results support the potential for using a PPG signal for calibration-free cuffless blood pressure estimation and improving accuracy by adding information from cardiovascular dynamics to different methods in the cuffless blood pressure monitoring field.


Asunto(s)
Fotopletismografía , Análisis de la Onda del Pulso , Humanos , Presión Sanguínea/fisiología , Fotopletismografía/métodos , Análisis de la Onda del Pulso/métodos , Determinación de la Presión Sanguínea/métodos , Esfigmomanometros
2.
Sensors (Basel) ; 23(13)2023 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-37448029

RESUMEN

A new method for accurately estimating heart rates based on a single photoplethysmography (PPG) signal and accelerations is proposed in this study, considering motion artifacts due to subjects' hand motions and walking. The method comprises two sub-algorithms: pre-quality checking and motion artifact removal (MAR) via Hankel decomposition. PPGs and accelerations were collected using a wearable device equipped with a PPG sensor patch and a 3-axis accelerometer. The motion artifacts caused by hand movements and walking were effectively mitigated by the two aforementioned sub-algorithms. The first sub-algorithm utilized a new quality-assessment criterion to identify highly noise-contaminated PPG signals and exclude them from subsequent processing. The second sub-algorithm employed the Hankel matrix and singular value decomposition (SVD) to effectively identify, decompose, and remove motion artifacts. Experimental data collected during hand-moving and walking were considered for evaluation. The performance of the proposed algorithms was assessed using the datasets from the IEEE Signal Processing Cup 2015. The obtained results demonstrated an average error of merely 0.7345 ± 8.1129 beats per minute (bpm) and a mean absolute error of 1.86 bpm for walking, making it the second most accurate method to date that employs a single PPG and a 3-axis accelerometer. The proposed method also achieved the best accuracy of 3.78 bpm in mean absolute errors among all previously reported studies for hand-moving scenarios.


Asunto(s)
Ejercicio Físico , Fotopletismografía , Humanos , Frecuencia Cardíaca/fisiología , Fotopletismografía/métodos , Ejercicio Físico/fisiología , Procesamiento de Señales Asistido por Computador , Algoritmos , Artefactos
3.
Sensors (Basel) ; 23(17)2023 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-37687854

RESUMEN

Accurately measuring blood pressure (BP) is essential for maintaining physiological health, which is commonly achieved using cuff-based sphygmomanometers. Several attempts have been made to develop cuffless sphygmomanometers. To increase their accuracy and long-term variability, machine learning methods can be applied for analyzing photoplethysmogram (PPG) signals. Here, we propose a method to estimate the BP during exercise using a cuffless device. The BP estimation process involved preprocessing signals, feature extraction, and machine learning techniques. To ensure the reliability of the signals extracted from the PPG, we employed the skewness signal quality index and the RReliefF algorithm for signal selection. Thereafter, the BP was estimated using the long short-term memory (LSTM)-based neural network. Seventeen young adult males participated in the experiments, undergoing a structured protocol composed of rest, exercise, and recovery for 20 min. Compared to the BP measured using a non-invasive voltage clamp-type continuous sphygmomanometer, that estimated by the proposed method exhibited a mean error of 0.32 ± 7.76 mmHg, which is equivalent to the accuracy of a cuff-based sphygmomanometer per regulatory standards. By enhancing patient comfort and improving healthcare outcomes, the proposed approach can revolutionize BP monitoring in various settings, including clinical, home, and sports environments.


Asunto(s)
Determinación de la Presión Sanguínea , Ejercicio Físico , Masculino , Adulto Joven , Humanos , Presión Sanguínea , Reproducibilidad de los Resultados , Monitores de Presión Sanguínea
4.
Proc IEEE Inst Electr Electron Eng ; 110(3): 355-381, 2022 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-35356509

RESUMEN

Smart wearables provide an opportunity to monitor health in daily life and are emerging as potential tools for detecting cardiovascular disease (CVD). Wearables such as fitness bands and smartwatches routinely monitor the photoplethysmogram signal, an optical measure of the arterial pulse wave that is strongly influenced by the heart and blood vessels. In this survey, we summarize the fundamentals of wearable photoplethysmography and its analysis, identify its potential clinical applications, and outline pressing directions for future research in order to realize its full potential for tackling CVD.

5.
Sensors (Basel) ; 22(17)2022 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-36080924

RESUMEN

Heart sounds and heart rate (pulse) are the most common physiological signals used in the diagnosis of cardiovascular diseases. Measuring these signals using a device and analyzing their interrelationships simultaneously can improve the accuracy of existing methods and propose new approaches for the diagnosis of cardiovascular diseases. In this study, we have presented a novel smart stethoscope based on multimodal physiological signal measurement technology for personal cardiovascular health monitoring. The proposed device is designed in the shape of a compact personal computer mouse for easy grasping and attachment to the surface of the chest using only one hand. A digital microphone and photoplehysmogram sensor are installed on the bottom and top surfaces of the device, respectively, to measure heart sound and pulse from the user's chest and finger simultaneously. In addition, a high-performance Bluetooth Low Energy System-on-Chip ARM microprocessor is used for pre-processing of measured data and communication with the smartphone. The prototype is assembled on a manufactured printed circuit board and 3D-printed shell to conduct an in vivo experiment to test the performance of physiological signal measurement and usability by observing users' muscle fatigue variation.


Asunto(s)
Enfermedades Cardiovasculares , Ruidos Cardíacos , Estetoscopios , Ruidos Cardíacos/fisiología , Humanos , Procesamiento de Señales Asistido por Computador , Tecnología
6.
Sensors (Basel) ; 22(21)2022 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-36365837

RESUMEN

With the recent advancements in the field of wearable technologies, the opportunity to monitor stress continuously using different physiological variables has gained significant interest. The early detection of stress can help improve healthcare and minimizes the negative impact of long-term stress. This paper reports outcomes of a pilot study and associated stress-monitoring dataset, named the "Stress-Predict Dataset", created by collecting physiological signals from healthy subjects using wrist-worn watches with a photoplethysmogram (PPG) sensor. While wearing these watches, 35 healthy volunteers underwent a series of tasks (i.e., Stroop color test, Trier Social Stress Test and Hyperventilation Provocation Test), along with a rest period in-between each task. They also answered questionnaires designed to induce stress levels compatible with daily life. The changes in the blood volume pulse (BVP) and heart rate were recorded by the watch and were labelled as occurring during stress-inducing tasks or a rest period (no stress). Additionally, respiratory rate was estimated using the BVP signal. Statistical models and personalised adaptive reference ranges were used to determine the utility of the proposed stressors and the extracted variables (heart rate and respiratory rate). The analysis showed that the interview session was the most significant stress stimulus, causing a significant variation in heart rate of 27 (77%) participants and respiratory rate of 28 (80%) participants out of 35. The outcomes of this study contribute to the understanding the role of stressors and their association with physiological response and provide a dataset to help develop new wearable solutions for more reliable, valid, and sensitive physio-logical stress monitoring.


Asunto(s)
Dispositivos Electrónicos Vestibles , Humanos , Proyectos Piloto , Frecuencia Cardíaca/fisiología , Monitoreo Fisiológico , Frecuencia Respiratoria , Fotopletismografía
7.
Sensors (Basel) ; 21(21)2021 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-34770303

RESUMEN

Inertial sensors are widely used in the field of human activity recognition (HAR), since this source of information is the most informative time series among non-visual datasets. HAR researchers are actively exploring other approaches and different sources of signals to improve the performance of HAR systems. In this study, we investigate the impact of combining bio-signals with a dataset acquired from inertial sensors on recognizing human daily activities. To achieve this aim, we used the PPG-DaLiA dataset consisting of 3D-accelerometer (3D-ACC), electrocardiogram (ECG), photoplethysmogram (PPG) signals acquired from 15 individuals while performing daily activities. We extracted hand-crafted time and frequency domain features, then, we applied a correlation-based feature selection approach to reduce the feature-set dimensionality. After introducing early fusion scenarios, we trained and tested random forest models with subject-dependent and subject-independent setups. Our results indicate that combining features extracted from the 3D-ACC signal with the ECG signal improves the classifier's performance F1-scores by 2.72% and 3.00% (from 94.07% to 96.80%, and 83.16% to 86.17%) for subject-dependent and subject-independent approaches, respectively.


Asunto(s)
Fotopletismografía , Procesamiento de Señales Asistido por Computador , Acelerometría , Electrocardiografía , Actividades Humanas , Humanos
8.
Sensors (Basel) ; 21(5)2021 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-33800106

RESUMEN

Blood pressure (BP) monitoring has significant importance in the treatment of hypertension and different cardiovascular health diseases. As photoplethysmogram (PPG) signals can be recorded non-invasively, research has been highly conducted to measure BP using PPG recently. In this paper, we propose a U-net deep learning architecture that uses fingertip PPG signal as input to estimate arterial BP (ABP) waveform non-invasively. From this waveform, we have also measured systolic BP (SBP), diastolic BP (DBP), and mean arterial pressure (MAP). The proposed method was evaluated on a subset of 100 subjects from two publicly available databases: MIMIC and MIMIC-III. The predicted ABP waveforms correlated highly with the reference waveforms and we have obtained an average Pearson's correlation coefficient of 0.993. The mean absolute error is 3.68 ± 4.42 mmHg for SBP, 1.97 ± 2.92 mmHg for DBP, and 2.17 ± 3.06 mmHg for MAP which satisfy the requirements of the Association for the Advancement of Medical Instrumentation (AAMI) standard and obtain grade A according to the British Hypertension Society (BHS) standard. The results show that the proposed method is an efficient process to estimate ABP waveform directly using fingertip PPG.


Asunto(s)
Hipertensión , Fotopletismografía , Presión Arterial , Presión Sanguínea , Determinación de la Presión Sanguínea , Humanos , Hipertensión/diagnóstico
9.
Sensors (Basel) ; 21(4)2021 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-33567575

RESUMEN

Cardiopulmonary monitoring is important and useful for diagnosing and managing multiple conditions, such as stress and sleep disorders. Wearable ambulatory systems can provide continuous, comfortable, and inexpensive means for monitoring; it always has been a research subject in recent years. Being simple and cost-effective, electrocardiogram-based commercial products can be found in the market that provides cardiac diagnostic information for assessment, including heart rate measurement and atrial fibrillation identification. Based on a data-driven and self-adaptive approach, this study aims to estimate heart rate and respiratory rate simultaneously from one lead electrocardiogram signal. In contrast to ensemble empirical mode decomposition with principle component analysis, performed in the time domain, our method uses spectral data fusion, together with intrinsic mode functions using ensemble empirical mode decomposition obtains a more accurate heart rate and respiratory rate. Equipped with a rule-based selection of defined frequency levels for respiratory rate (RR) estimation, the proposed method obtains (0.92, 1.32) beat per minute for the heart rate and (2.20, 2.92) breath per minute for the respiratory rate as their mean absolute error and root mean square error, respectively outperforming other existing methods.


Asunto(s)
Algoritmos , Frecuencia Cardíaca , Frecuencia Respiratoria , Procesamiento de Señales Asistido por Computador , Arritmias Cardíacas , Electrocardiografía , Humanos
10.
IEEE Sens J ; 23(3): 1734-1751, 2020 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37655115

RESUMEN

Worldwide,an estimated 461 000 people die from asthma attacks each year. While there remain treatments to alleviate asthma symptoms and reduce deaths, patient deterioration needs to be identified in sufficient time. To prevent asthma deterioration, patients need to be aware of personal and environmental triggers and monitor their asthma symptoms. The aim of this article is to provide a comprehensive review of the current state-of-the-art wearable sensors and devices that use vital signs for asthma patient monitoring and management. Among all vital signs, breathing rate and airflow sound are key indicators of asthmatic patients' health that can be measured directly using wearable sensors to provide continuous and constant patient monitoring or indirectly by estimations based on proven algorithms using electrocardiogram (ECG), photoplethysmogram (PPG), and chest movements. ECG and PPG signals are widely used in smart watches and chest bands, enabling easy integration of a more extensive body sensor framework for asthmatic exacerbation prediction. Other vital signs used in asthma patient monitoring include blood oxygen saturation, temperature, blood pressure, verbal sound, and pain responses. The use of wearable vital signs enabled a broad range of wearable sensor application scenarios for asthma monitoring and management.

11.
Sensors (Basel) ; 20(19)2020 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-33007891

RESUMEN

Blood pressure monitoring is one avenue to monitor people's health conditions. Early detection of abnormal blood pressure can help patients to get early treatment and reduce mortality associated with cardiovascular diseases. Therefore, it is very valuable to have a mechanism to perform real-time monitoring for blood pressure changes in patients. In this paper, we propose deep learning regression models using an electrocardiogram (ECG) and photoplethysmogram (PPG) for the real-time estimation of systolic blood pressure (SBP) and diastolic blood pressure (DBP) values. We use a bidirectional layer of long short-term memory (LSTM) as the first layer and add a residual connection inside each of the following layers of the LSTMs. We also perform experiments to compare the performance between the traditional machine learning methods, another existing deep learning model, and the proposed deep learning models using the dataset of Physionet's multiparameter intelligent monitoring in intensive care II (MIMIC II) as the source of ECG and PPG signals as well as the arterial blood pressure (ABP) signal. The results show that the proposed model outperforms the existing methods and is able to achieve accurate estimation which is promising in order to be applied in clinical practice effectively.


Asunto(s)
Determinación de la Presión Sanguínea , Aprendizaje Profundo , Monitoreo Fisiológico , Presión Sanguínea , Electrocardiografía , Humanos , Fotopletismografía
12.
Sensors (Basel) ; 20(19)2020 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-33020401

RESUMEN

Due to the growing public awareness of cardiovascular disease (CVD), blood pressure (BP) estimation models have been developed based on physiological parameters extracted from both electrocardiograms (ECGs) and photoplethysmograms (PPGs). Still, in order to enhance the usability as well as reduce the sensor cost, researchers endeavor to establish a generalized BP estimation model using only PPG signals. In this paper, we propose a deep neural network model capable of extracting 32 features exclusively from PPG signals for BP estimation. The effectiveness and accuracy of our proposed model was evaluated by the root mean square error (RMSE), mean absolute error (MAE), the Association for the Advancement of Medical Instrumentation (AAMI) standard and the British Hypertension Society (BHS) standard. Experimental results showed that the RMSEs in systolic blood pressure (SBP) and diastolic blood pressure (DBP) are 4.643 mmHg and 3.307 mmHg, respectively, across 9000 subjects, with 80.63% of absolute errors among estimated SBP records lower than 5 mmHg and 90.19% of absolute errors among estimated DBP records lower than 5 mmHg. We demonstrated that our proposed model has remarkably high accuracy on the largest BP database found in the literature, which shows its effectiveness compared to some prior works.


Asunto(s)
Determinación de la Presión Sanguínea , Redes Neurales de la Computación , Fotopletismografía , Presión Sanguínea , Humanos , Análisis de la Onda del Pulso
13.
Sensors (Basel) ; 19(23)2019 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-31810275

RESUMEN

Embodied emotion is associated with interaction among a person's physiological responses, behavioral patterns, and environmental factors. However, most methods for determining embodied emotion has been considered on only fragmentary independent variables and not their inter-connectivity. This study suggests a method for determining the embodied emotion considering interactions among three factors: the physiological response, behavioral patterns, and an environmental factor based on life-logging. The physiological response was analyzed as heart rate variability (HRV) variables. The behavioral pattern was calculated from features of Global Positioning System (GPS) locations that indicate spatiotemporal property. The environmental factor was analyzed as the ambient noise, which is an external stimulus. These data were mapped with the emotion of that time. The emotion was evaluated on a seven-point scale for arousal level and valence level according to Russell's model of emotion. These data were collected from 79 participants in daily life for two weeks. Their relationships among data were analyzed by the multiple regression analysis, after pre-processing the respective data. As a result, significant differences between the arousal level and valence level of emotion were observed based on their relations. The contributions of this study can be summarized as follows: (1) The emotion was recognized in real-life for a more practical application; (2) distinguishing the interactions that determine the levels of arousal and positive emotion by analyzing relationships of individuals' life-log data. Through this, it was verified that emotion can be changed according to the interaction among the three factors, which was overlooked in previous emotion recognition.


Asunto(s)
Emociones/fisiología , Femenino , Sistemas de Información Geográfica , Humanos , Masculino , Fotopletismografía
14.
Sensors (Basel) ; 18(5)2018 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-29751681

RESUMEN

The photoplethysmogram (PPG) is a biomedical signal that can be used to estimate volumetric blood flow changes in the peripheral circulation. During the past few years, several works have been published in order to assess the potential for PPGs to be used in biometric authentication systems, but results are inconclusive. In this paper we perform an analysis of the feasibility of using the PPG as a realistic biometric alternative in the long term. Several feature extractors (based on the time domain and the Karhunen⁻Loève transform) and matching metrics (Manhattan and Euclidean distances) have been tested using four different PPG databases (PRRB, MIMIC-II, Berry, and Nonin). We show that the false match rate (FMR) and false non-match rate (FNMR) values remain constant in different time instances for a selected threshold, which is essential for using the PPG for biometric authentication purposes. On the other hand, obtained equal error rate (EER) values for signals recorded during the same session range from 1.0% for high-quality signals recorded in controlled conditions to 8% for those recorded in conditions closer to real-world scenarios. Moreover, in certain scenarios, EER values rise up to 23.2% for signals recorded over different days, signaling that performance degradation could take place with time.

15.
Heliyon ; 10(6): e27779, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38533045

RESUMEN

Background and objective: Hypertension is a potentially dangerous health condition that can be detected by measuring blood pressure (BP). Blood pressure monitoring and measurement are essential for preventing and treating cardiovascular diseases. Cuff-based devices, on the other hand, are uncomfortable and prevent continuous BP measurement. Methods: In this study, a new non-invasive and cuff-less method for estimating Systolic Blood Pressure (SBP), Mean Arterial Pressure (MAP), and Diastolic Blood Pressure (DBP) has been proposed using characteristic features of photoplethysmogram (PPG) signals and nonlinear regression algorithms. PPG signals were collected from 219 participants, which were then subjected to preprocessing and feature extraction steps. Analyzing PPG and its derivative signals, a total of 46 time, frequency, and time-frequency domain features were extracted. In addition, the age and gender of each subject were also included as features. Further, correlation-based feature selection (CFS) and Relief F feature selection (ReliefF) techniques were used to select the relevant features and reduce the possibility of over-fitting the models. Finally, support vector regression (SVR), K-nearest neighbour regression (KNR), decision tree regression (DTR), and random forest regression (RFR) were established to develop the BP estimation model. Regression models were trained and evaluated on all features as well as selected features. The best regression models for SBP, MAP, and DBP estimations were selected separately. Results: The SVR model, along with the ReliefF-based feature selection algorithm, outperforms other algorithms in estimating the SBP, MAP, and DBP with the mean absolute error of 2.49, 1.62 and 1.43 mmHg, respectively. The proposed method meets the Advancement of Medical Instrumentation standard for BP estimations. Based on the British Hypertension Society standard, the results also fall within Grade A for SBP, MAP, and DBP. Conclusion: The findings show that the method can be used to estimate blood pressure non-invasively, without using a cuff or calibration, and only by utilizing the PPG signal characteristic features.

16.
Bioengineering (Basel) ; 10(2)2023 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-36829661

RESUMEN

The continuous monitoring of respiratory rate (RR) and oxygen saturation (SpO2) is crucial for patients with cardiac, pulmonary, and surgical conditions. RR and SpO2 are used to assess the effectiveness of lung medications and ventilator support. In recent studies, the use of a photoplethysmogram (PPG) has been recommended for evaluating RR and SpO2. This research presents a novel method of estimating RR and SpO2 using machine learning models that incorporate PPG signal features. A number of established methods are used to extract meaningful features from PPG. A feature selection approach was used to reduce the computational complexity and the possibility of overfitting. There were 19 models trained for both RR and SpO2 separately, from which the most appropriate regression model was selected. The Gaussian process regression model outperformed all the other models for both RR and SpO2 estimation. The mean absolute error (MAE) for RR was 0.89, while the root-mean-squared error (RMSE) was 1.41. For SpO2, the model had an RMSE of 0.98 and an MAE of 0.57. The proposed system is a state-of-the-art approach for estimating RR and SpO2 reliably from PPG. If RR and SpO2 can be consistently and effectively derived from the PPG signal, patients can monitor their RR and SpO2 at a cheaper cost and with less hassle.

17.
Comput Methods Programs Biomed ; 229: 107294, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36528998

RESUMEN

BACKGROUND AND OBJECTIVE: Acquiring accurate and reliable health information using a PPG signal in wearable devices requires suppressing motion artifacts. This paper presents a method based on the Fractional Fourier transform (FrFT) to effectively suppress the motion artifacts in a Photoplethysmogram (PPG) signal for an accurate estimation of heart rate (HR). METHODS: By analyzing various PPG signals recorded under various physiological conditions and sampling frequencies, the proposed work determines an optimal value of the fractional order of the proposed FrFT. The proposed FrFT-based algorithm separates the motion artifacts component from the acquired PPG signal. Finally, the HR estimation accuracy during the strong motion artifact-affected windows is improved using a post-processing technique. The efficacy of the proposed method is evaluated by computing the root mean square error (RMSE). RESULTS: The performance of the proposed algorithm is compared with methods in recent studies using test and training datasets from the IEEE Signal Processing Cup (SPC). The proposed method provides the mean absolute error of 1.88 beats per minute (BPM) on all twenty-three recordings. CONCLUSIONS: The proposed method uses the Fourier method in the fractional domain. A noisy signal is rotated into an intermediate plane between the time and frequency domains to separate the signal from the noise. The algorithm incorporates FrFT analysis to suppress motion artifacts from PPG signals to estimate HR accurately. Further, a post-processing step is used to track the HR for accurate and reliable HR estimation. The proposed FrFT-based algorithm doesn't require additional reference accelerometers or hardware to estimate HR in real-time. The noise and signal separation is optimum for a fractional order (a) value in the vicinity of 0.6. The optimized value of fractional order is constant irrespective of the physical activity and sampling frequency.


Asunto(s)
Ejercicio Físico , Fotopletismografía , Análisis de Fourier , Frecuencia Cardíaca/fisiología , Fotopletismografía/métodos , Ejercicio Físico/fisiología , Procesamiento de Señales Asistido por Computador , Artefactos , Algoritmos
18.
Artif Intell Med ; 145: 102685, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37925216

RESUMEN

Reflectance-based photoplethysmogram (PPG) sensors provide flexible options of measuring sites for blood oxygen saturation (SpO2) measurement. But they are mostly limited by accuracy, especially when applied to different subjects, due to the diverse human characteristics (skin colors, hair density, etc.) and usage conditions of different sensor settings. This study addresses the estimation of SpO2 at non-standard measuring sites employing reflectance-based sensors. It proposes an automated construction of subject inclusion-exclusion criteria for SpO2 measuring devices, using a combination of unsupervised clustering, supervised regression, and model explanations. This is perhaps among the first adaptation of SHAP to explain the clusters gleaned from unsupervised learning methods. As a wellness application case study, we developed a pillow-based wearable device to collect reflectance PPGs from both the brachiocephalic and carotid arteries around the neck. The experiment was conducted on 33 subjects, each under totally 80 different sensor settings. The proposed approach addressed the variations of humans and devices, as well as the heterogeneous mapping between signals and SpO2 values. It identified effective device settings and characteristics of their applicable subject groups (i.e., subject inclusion-exclusion criteria). Overall, it reduced the root mean squared error (RMSE) by 16%, compared to an empirical formula and a plain SpO2 estimation model.


Asunto(s)
Oxígeno , Fotopletismografía , Humanos , Fotopletismografía/métodos , Oximetría/métodos , Aprendizaje Automático
19.
Bioengineering (Basel) ; 9(11)2022 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-36421093

RESUMEN

Cardiovascular diseases are one of the most severe causes of mortality, annually taking a heavy toll on lives worldwide. Continuous monitoring of blood pressure seems to be the most viable option, but this demands an invasive process, introducing several layers of complexities and reliability concerns due to non-invasive techniques not being accurate. This motivates us to develop a method to estimate the continuous arterial blood pressure (ABP) waveform through a non-invasive approach using Photoplethysmogram (PPG) signals. We explore the advantage of deep learning, as it would free us from sticking to ideally shaped PPG signals only by making handcrafted feature computation irrelevant, which is a shortcoming of the existing approaches. Thus, we present PPG2ABP, a two-stage cascaded deep learning-based method that manages to estimate the continuous ABP waveform from the input PPG signal with a mean absolute error of 4.604 mmHg, preserving the shape, magnitude, and phase in unison. However, the more astounding success of PPG2ABP turns out to be that the computed values of Diastolic Blood Pressure (DBP), Mean Arterial Pressure (MAP), and Systolic Blood Pressure (SBP) from the estimated ABP waveform outperform the existing works under several metrics (mean absolute error of 3.449 ± 6.147 mmHg, 2.310 ± 4.437 mmHg, and 5.727 ± 9.162 mmHg, respectively), despite that PPG2ABP is not explicitly trained to do so. Notably, both for DBP and MAP, we achieve Grade A in the BHS (British Hypertension Society) Standard and satisfy the AAMI (Association for the Advancement of Medical Instrumentation) standard.

20.
Front Public Health ; 10: 920946, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35844894

RESUMEN

Fiducial points of photoplethysmogram (PPG), first derivative PPG (VPG), and second derivative PPG (APG) are essential in extracting numerous parameters to diagnose cardiovascular disease. However, the fiducial points were usually detected using complex mathematical algorithms. Inflection points from derivatives waveforms are not thoroughly studied, whereas they can significantly assist in peak detection. This study is performed to investigate the derivative waveforms of PPG and use them to detect the important peaks of PPG, VPG, and APG. PPGs with different morphologies from 43 ischemic heart disease subjects are analyzed. Inflection points of the derivative waveforms up to the fourth level are observed, and consistent information (derivative markers) is used to detect the fiducial points of PPG, VPG, and APG with proper sequence. Moving average filter and simple thresholding techniques are applied to detect the primary points in VPG and the third derivative waveform. A total of twelve out of twenty derivative markers are found reliable in detecting fiducial points of two common types of PPG. Systolic peaks are accurately detected with 99.64% sensitivity and 99.38% positive predictivity using the 43 IHD dataset and Complex System Laboratory (CSL) Pulse Oximetry Artifact Labels database. The study has introduced the fourth derivative PPG waveform with four main points, which are significantly valuable for detecting the fiducial points of PPG, VPG, and APG.


Asunto(s)
Artefactos , Fotopletismografía , Algoritmos , Humanos , Fotopletismografía/métodos
SELECCIÓN DE REFERENCIAS