Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 616
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(11): 922-936, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38243773

RESUMEN

BACKGROUND AND AIMS: Risk stratification for mitral valve transcatheter edge-to-edge repair (M-TEER) is paramount in the decision-making process to appropriately select patients with severe secondary mitral regurgitation (SMR). This study sought to develop and validate an artificial intelligence-derived risk score (EuroSMR score) to predict 1-year outcomes (survival or survival + clinical improvement) in patients with SMR undergoing M-TEER. METHODS: An artificial intelligence-derived risk score was developed from the EuroSMR cohort (4172 and 428 patients treated with M-TEER in the derivation and validation cohorts, respectively). The EuroSMR score was validated and compared with established risk models. RESULTS: The EuroSMR risk score, which is based on 18 clinical, echocardiographic, laboratory, and medication parameters, allowed for an improved discrimination of surviving and non-surviving patients (hazard ratio 4.3, 95% confidence interval 3.7-5.0; P < .001), and outperformed established risk scores in the validation cohort. Prediction for 1-year mortality (area under the curve: 0.789, 95% confidence interval 0.737-0.842) ranged from <5% to >70%, including the identification of an extreme-risk population (2.6% of the entire cohort), which had a very high probability for not surviving beyond 1 year (hazard ratio 6.5, 95% confidence interval 3.0-14; P < .001). The top 5% of patients with the highest EuroSMR risk scores showed event rates of 72.7% for mortality and 83.2% for mortality or lack of clinical improvement at 1-year follow-up. CONCLUSIONS: The EuroSMR risk score may allow for improved prognostication in heart failure patients with severe SMR, who are considered for a M-TEER procedure. The score is expected to facilitate the shared decision-making process with heart team members and patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Inteligencia Artificial , Corazón , Ecocardiografía , Factores de Riesgo , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 103(1): 147-152, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37855205

RESUMEN

BACKGROUNDS: Transcatheter edge-to-edge repair (TEER) devices are used for primary mitral regurgitation (MR) and secondary MR. Despite the growing use of TEER devices, there have not been many studies on operator experience or procedure volumes by state. AIMS: We aimed to investigate nationwide operator volume trends and geographic variation in access to TEER. METHODS: The United States Center for Medicare and Medicaid Services (CMS) National Medicare Provider Utilization and Payment Database (MPUPD) was analyzed between 2015 and 2020 for initial TEER procedures. RESULTS: Procedure volume and total operators increased yearly from 2015 to 2019 but declined in 2020. Mean annual procedure volume per operator varied significantly by state, between 0 in multiple states and 35 in North Dakota. In 2019, 994 unique operators were identified, with 295 operators documented performing 10 or more procedures (29.68%). Operators performing 10 or more TEER procedures provided 68.46% of all operations in 2019, averaging 20.94 procedures per operator. CONCLUSIONS: TEER procedures are becoming increasingly common as more operators are being trained. However, significant variability exists in the procedural volume per operator.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Estados Unidos , Humanos , Medicare , Resultado del Tratamiento , Bases de Datos Factuales , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
3.
Catheter Cardiovasc Interv ; 103(4): 618-625, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38436540

RESUMEN

BACKGROUND: Mitral annular calcification (MAC) has been an exclusion for many of the earlier pivotal trials that were instrumental in gaining device approval and indications for mitral transcatheter edge-to-edge repair (M-TEER). AIMS: To evaluate the impact of MAC on the procedural durability and success of newer generation MitraClip® systems (G3 and G4 systems). METHODS: Data were collected from Northwell TEER registry. Patients that underwent M-TEER with third or fourth generation MitraClip device were included. Patients were divided into -MAC (none-mild) and +MAC (moderate-severe) groups. Procedural success was defined as ≤ grade 2 + mitral regurgitation (MR) postprocedure, and durability was defined as ≤ grade 2 + MR retention at 1 month and 1 year. Univariate analysis compared outcomes between groups. RESULTS: Of 260 M-TEER patients, 160 were -MAC and 100 were +MAC. Procedural success was comparable; however, there were three patients who required conversion to cardiac surgery during the index hospitalization in the +MAC group versus none in the -MAC group (though this was not statistically significant). At 1-month follow-up, there were no significant differences in MR severity. At 1-year follow-up, +MAC had higher moderate-severe MR (22.1% vs. 7.5%; p = 0.002) and higher mean transmitral gradients (5.3 vs. 4.0 mmHg; p = 0.001) with no differences in mortality, New York Heart Association functional class or ejection fraction. CONCLUSION: In selective patients with high burden of MAC, contemporary M-TEER is safe, and procedural success is similar to patients with none-mild MAC. However, a loss of procedural durability was seen in +MAC group at 1-year follow-up. Further studies with longer follow-ups are required to assess newer mTEER devices and their potential clinical implications in patients with a high burden of MAC.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Hospitalización , Sistema de Registros , Tecnología
4.
Catheter Cardiovasc Interv ; 103(2): 340-347, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38156508

RESUMEN

BACKGROUND: There is currently little evidence for transcatheter edge-to-edge mitral valve repair (TEER) for mitral regurgitation (MR) in patients with cardiogenic shock (CS). Therefore, this study investigated the characteristics and outcomes of CS patients who underwent TEER for MR. METHODS: PubMed, EMBASE were searched in July 2023. Case series and observational studies reporting clinical characteristics and outcomes in CS patients with MR who underwent TEER were included. We performed a one-group meta-analysis using a random effects model. RESULTS: A total of 4060 patients from 7 case series and 5 observational studies were included. The mean age was 68.2 (95% confidence interval [CI]: 64.1-72.2) years, and 41.4% of patients (95% CI: 39.1%-43.7%) were female. Pre-TEER, severe MR was present in 85.3% (95% CI: 76.1%-91.3%) of patients. Mean left ventricular ejection fraction was 36.7% (95% CI: 29.2%-44.2%), and 54.6% (95% CI: 36.9%-71.2%) of patients received mechanical circulatory support. The severity of MR post-TEER was less than 2+ in 88% (95% CI: 87%-89%) of patients. In-hospital mortality was 11% (95% CI: 10%-13%), whereas 30-day and 1-year mortality rates were 15% (95% CI: 13%-16%), and 36% (95% CI: 21%-54%), respectively. CONCLUSIONS: This systematic review and meta-analysis assessed the clinical characteristics and outcomes of TEER in CS patients with MR. TEER for MR in patients with CS has been successful in reducing MR in most of the patients, but with a high mortality rate. Randomized controlled trials of TEER for MR and CS are needed.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Anciano , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
5.
Catheter Cardiovasc Interv ; 103(7): 1138-1144, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38695165

RESUMEN

Following the introduction in the latest European and American guidelines, transcatheter edge-to-edge repair has become a valid alternative to surgery for ineligible patients. Among the available technologies, MitraClip (Abbott) was the first to be introduced for the percutaneous treatment of mitral regurgitation with the edge-to-edge technique. Although its safety and effectiveness has been widely demonstrated, the optimal procedural results are highly dependent from operators' experience. In this manuscript, we provide a full guide of advanced steering maneuvers of MitraClip in different scenarios of transseptal puncture.


Asunto(s)
Cateterismo Cardíaco , Catéteres Cardíacos , Insuficiencia de la Válvula Mitral , Válvula Mitral , Punciones , Humanos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Diseño de Equipo , Tabiques Cardíacos/cirugía , Tabiques Cardíacos/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 103(7): 1148-1151, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38639161

RESUMEN

The transcatheter edge-to-edge mitral valve repair (TEER) has been recommended as a reliable treatment option for selected patients with severe degenerative and functional mitral regurgitation (MR). Although MR patients with rheumatic etiology were excluded from two significant trials (EVEREST II and COAPT) that established a role for the TEER in degenerative and functional MR. However, it has been reported that the TEER procedure could be safely and effectively performed in carefully selected rheumatic MR patients. Therefore, we share a case report of successfully treating severe rheumatic MR using a novel-designed TEER system (JensClipTM).


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Cardiopatía Reumática , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/etiología , Cateterismo Cardíaco/instrumentación , Resultado del Tratamiento , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/cirugía , Cardiopatía Reumática/fisiopatología , Cardiopatía Reumática/terapia , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Femenino , Ecocardiografía Transesofágica , Ecocardiografía Doppler en Color , Diseño de Prótesis , Prótesis Valvulares Cardíacas , Persona de Mediana Edad , Masculino
7.
Artículo en Inglés | MEDLINE | ID: mdl-39049480

RESUMEN

Mitral regurgitation (MR) is the most common heart valve disease, and transcatheter edge-to-edge repair (TEER) has been recommended as a therapy for severe MR patients by guidelines. The classic Carpentier classification used to guide surgical mitral valve repair but is inadequate for mitral TEER (M-TEER). We herein proposed a new modified Carpentier classification named after "type + segment," which is suitable for M-TEER. We shared our strategies in M-TEER procedure for screening and performing the M-TEER according to the new modified Carpentier classification.

8.
Catheter Cardiovasc Interv ; 104(2): 390-400, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38736245

RESUMEN

BACKGROUND: Malnutrition is associated with poor prognosis in several cardiovascular diseases; however, its role in patients with secondary mitral regurgitation (SMR) is poorly known. AIMS: To evaluate the impact of nutritional status, assessed using different scores, on clinical outcomes in patients with SMR undergoing transcatheter edge-to-edge repair (TEER) in a real-world setting. METHODS: A total of 658 patients with SMR and complete nutritional data were identified from the MIVNUT registry. Nutritional status has been assessed using controlling nutritional status index (CONUT), prognostic nutritional index (PNI), and geriatric nutritional risk index (GNRI) scores. Outcomes of interest were all-cause mortality and all-cause mortality or heart failure (HF) hospitalization. RESULTS: Any malnutrition grade was observed in 79.4%, 16.7%, and 47.9% of patients by using CONUT, PNI, and GNRI, respectively, while moderate to severe malnutrition was noted in 24.7%, 16.7%, and 25.6% of patients, respectively. At a median follow-up of 2.2 years, 212 patients (32.2%) died. Moderate-severe malnutrition was associated with a higher rate of all-cause mortality (HR: 2.46 [95% CI: 1.69-3.58], HR: 2.18 [95% CI: 1.46-3.26], HR: 1.97 [95% CI: 1.41-2.74] for CONUT, PNI, and GNRI scores, respectively). The combined secondary endpoint of all-cause mortality and HF rehospitalization occurred in 306 patients (46.5%). Patients with moderate-severe malnutrition had a higher risk of the composite endpoint (HR: 1.56 [95% CI: 1.20-2.28], HR: 1.55 [95% CI: 1.01-2.19], HR: 1.36 [95% CI: 1.02-1.80] for CONUT, PNI, and GNRI scores, respectively). After adjustment for multiple confounders, moderate-severe malnutrition remained independently associated with clinical outcomes. CONCLUSIONS: Moderate-severe malnutrition was common in patients with SMR undergoing TEER. It was independently associated with poor prognosis regardless of the different scores used.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Desnutrición , Insuficiencia de la Válvula Mitral , Válvula Mitral , Evaluación Nutricional , Estado Nutricional , Sistema de Registros , Humanos , Desnutrición/mortalidad , Desnutrición/diagnóstico , Desnutrición/fisiopatología , Femenino , Masculino , Anciano , Factores de Riesgo , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Resultado del Tratamiento , Prevalencia , Factores de Tiempo , Medición de Riesgo , Anciano de 80 o más Años , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Estudios Retrospectivos
9.
Catheter Cardiovasc Interv ; 104(2): 378-389, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38829174

RESUMEN

BACKGROUND: Vasopressor test (VPT) might be useful in patients with functional mitral regurgitation (MR) and left ventricular dysfunction (MITRA-FR-like patients) during transcatheter edge-to-edge repair (TEER). AIMS: We aimed to evaluate the prognostic impact of VPT. METHODS: MR treated with TEER were included in a multicenter prospective registry. VPT was used intraprocedurally in patients with left ventricular dysfunction and/or hypotension. The 1-year echocardiographic and clinical outcomes were compared according to the use of VPT. The primary endpoint was a combination of mortality + heart failure (HF) readmission at 1-year. RESULTS: A total of 1115 patients were included, mean age was 72.8 ± 10.5 years and 30.4% were women. VPT was performed in 128 subjects (11.5%), more often in critically ill patients with biventricular dysfunction. Postprocedurally the VPT group had greater rate of MR ≥ 2+ (46.9% vs. 31.7%, p = 0.003) despite greater number of devices (≥2 clips, 52% vs. 40.6 p = 0.008) and device repositioning or new clip in 12.5%. At 1-year, the primary endpoint occurred more often in the VPT group (27.3% vs. 16.9%, p = 0.002) as well as all-cause mortality (21.9% vs. 8.1%, p ≤ 0.001) but no differences existed in HF readmission rate (14.8% vs. 13.2%, p = 0.610), cardiovascular mortality (4.4% vs. 3.9%, p = 0.713) or residual MR ≥ 2+ (51.1% vs 51.7%, p = 0.371). CONCLUSIONS: Dynamic evaluation of MR during TEER procedure through VPT was performed in patients with worse baseline risk who also presented higher all-cause mortality at 1-year follow-up. However, 1-year residual MR, cardiovascular mortality and HF readmission rate remained comparable suggesting that VPT might help in the management of MITRA-FR-like patients.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia de la Válvula Mitral , Válvula Mitral , Readmisión del Paciente , Valor Predictivo de las Pruebas , Sistema de Registros , Función Ventricular Izquierda , Humanos , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/cirugía , Femenino , Anciano , Masculino , Resultado del Tratamiento , Factores de Tiempo , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Estudios Prospectivos , Anciano de 80 o más Años , Factores de Riesgo , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Persona de Mediana Edad , Vasoconstrictores/uso terapéutico , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/diagnóstico , Recuperación de la Función , Medición de Riesgo , Hemodinámica
10.
Circ J ; 88(4): 531-538, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38008428

RESUMEN

BACKGROUND: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).Methods and Results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11-1.32; P=0.13). CONCLUSIONS: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Modelos de Riesgos Proporcionales , Cateterismo Cardíaco
11.
Circ J ; 88(4): 519-527, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38325820

RESUMEN

BACKGROUND: We investigated the efficacy of left ventricular (LV) myocardial damage by native T1mapping obtained with cardiac magnetic resonance (CMR) for patients undergoing transcatheter edge-to-edge repair (TEER).Methods and Results: We studied 40 symptomatic non-ischemic heart failure (HF) patients and ventricular functional mitral regurgitation (VFMR) undergoing TEER. LV myocardial damage was defined as the native T1Z-score, which was converted from native T1values obtained with CMR. The primary endpoint was defined as HF rehospitalization or cardiovascular death over 12 months after TEER. Multivariable Cox proportional hazards analysis showed that the native T1Z-score was the only independent parameter associated with cardiovascular events (hazard ratio 3.40; 95% confidential interval 1.51-7.67), and that patients with native T1Z-scores <2.41 experienced significantly fewer cardiovascular events than those with native T1Z-scores ≥2.41 (P=0.001). Moreover, the combination of a native T1Z-score <2.41 and more severe VFMR (effective regurgitant orifice area [EROA] ≥0.30 cm2) was associated with fewer cardiovascular events than a native T1Z-score ≥2.41 and less severe VFMR (EROA <0.30 cm2; P=0.002). CONCLUSIONS: Assessment of baseline LV myocardial damage based on native T1Z-scores obtained with CMR without gadolinium-based contrast media is a valuable additional parameter for better management of HF patients and VFMR following TEER.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Ventrículos Cardíacos , Corazón , Medios de Contraste , Cardiomiopatías/diagnóstico por imagen , Resultado del Tratamiento
12.
Echocardiography ; 41(6): e15861, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38853674

RESUMEN

BACKGROUND: Transesophageal echocardiography (TEE) is primarily used to guide transcatheter structural heart interventions, such as tricuspid transcatheter edge-to-edge repair (TEER). Although TEE has a good safety profile, it is still an invasive imaging technique that may be associated with complications, especially when performed during long transcatheter procedures or on frail patients. The aim of this study was to assess TEE-related complications during tricuspid TEER. METHODS: This is a prospective study enrolling 53 patients who underwent tricuspid TEER for severe tricuspid regurgitation (TR). TEE-related complications were assessed clinically and divided into major (life-threatening, major bleeding requiring transfusions or surgery, organ perforation, and persistent dysphagia) and minor (perioral hypesthesia, < 24 h dysphagia/odynophagia, minor intraoral bleeding and hematemesis not requiring transfusion) RESULTS: The median age of the patient population was 79 years; 43.4% had severe, 39.6% massive, and 17.6% torrential TR. 62.3% of patients suffered from upper gastrointestinal disorders. Acute procedural success (APS) was achieved in 88.7% in a median device time of 36 min. A negative association was shown between APS and lead-induced etiology (r = -.284, p = .040), baseline TR grade (r = -.410, p = .002), suboptimal TEE view (r = -.349, p = .012), device time (r = -.234, p = .043), and leaflet detachment (r = -.496, p < .0001). We did not observe any clinical manifest major or minor TEE-related complications during the hospitalization. CONCLUSIONS: Our study reinforces the good safety profile and efficacy of TEE guidance during tricuspid TEER. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious complications. Furthermore, suboptimal intraprocedural TEE views are associated with lower TR reduction rates. HIGHLIGHTS: Transesophageal echocardiography is a crucial and safe technique for guiding transcatheter structural heart interventions. A mix of mid/deep esophageal and trans gastric views, as well as real-time 3D imaging is generally used to guide the procedure. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious problems. A shorter device time is associated with more rarely probe-related complications. Suboptimal intraprocedural TEE views are associated with lower TR reduction rates.


Asunto(s)
Ecocardiografía Transesofágica , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Ecocardiografía Transesofágica/métodos , Femenino , Masculino , Estudios Prospectivos , Insuficiencia de la Válvula Tricúspide/cirugía , Anciano , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Anciano de 80 o más Años
13.
Eur Heart J Suppl ; 26(Suppl 1): i6-i10, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38867865

RESUMEN

The COAPT 5-year data demonstrate that compared with medical treatment transcatheter edge-to-edge repair (TEER) with the MitraClip in symptomatic patients with Grade 3+/Grade 4+ secondary mitral regurgitation (SMR) reduced by nearly half the annualized hospitalization risk (33 vs. 57%), by almost 30% the death rate (57 vs. 67%) and achieved significant and durable SMR reduction in 95% of patients. Control patients who crossed over to TEER at 2 years had better prognosis, but nearly half of them died before reaching crossover eligibility. Death or hospitalization for heart failure (HHF) occurred in 73.6% of TEER patients and 91.5% of controls within 5 years, pointing to a need for further study to address left ventricle (LV) dysfunction, the underlying cause of patient's disease. MTRA-FR targeted SMR using the same device and did not improve the composite endpoint of all-cause mortality or HHF at 12 months. Possible reasons for the discrepancy include enrolment of patients with more severe MR and less-advanced LV disease (dilation/dysfunction), less-procedural complications, and higher success in reducing MR in COAPT compared with MITRA-FR. Thus, the ideal patient for MitraClip treatment would be one with severe MR, but with no too severe LV dilation/dysfunction, which is what differentiates COAPT patients from those in MITRA-FR.

14.
J Biomech Eng ; 146(2)2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-37978048

RESUMEN

In recent years, transcatheter edge-to-edge repair (TEER) has been widely adopted as an effective treatment for mitral regurgitation (MR). The aim of this study is to develop a personalized in silico model to predict the effect of edge-to-edge repair in advance to the procedure for each individual patient. For this purpose, we propose a combination of a valve deformation model for computing the mitral valve (MV) orifice area (MVOA) and a lumped parameter model for the hemodynamics, specifically mitral regurgitation volume (RVol). Although we cannot obtain detailed information on the three-dimensional flow field near the mitral valve, we can rapidly simulate the important medical parameters for the clinical decision support. In the present method, we construct the patient-specific pre-operative models by using the parameter optimization and then simulate the postoperative state by applying the additional clipping condition. The computed preclip MVOAs show good agreement with the clinical measurements, and the correlation coefficient takes 0.998. In addition, the MR grade in terms of RVol also has good correlation with the grade by ground truth MVOA. Finally, we try to investigate the applicability for the predicting the postclip state. The simulated valve shapes clearly show the well-known double orifice and the improvement of the MVOA, compared with the preclip state. Similarly, we confirmed the improved reverse flow and MR grade in terms of RVol. A total computational time is approximately 8 h by using general-purpose PC. These results obviously indicate that the present in silico model has good capability for the assessment of edge-to-edge repair.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/cirugía , Resultado del Tratamiento , Simulación por Computador
15.
Curr Cardiol Rep ; 26(6): 459-474, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38884853

RESUMEN

PURPOSE OF REVIEW: Patients with severe tricuspid regurgitation (TR) are at risk for significant morbidity and mortality. Transcatheter tricuspid valve interventions (TTVI) may offer patients less invasive treatment alternatives to surgery. This review evaluates the most common class of device currently used worldwide to treat TR, tricuspid transcatheter edge-to-edge repair (T-TEER) and orthotopic transcatheter tricuspid valve replacement (TTVR), both of which are now approved in the USA and Europe. RECENT FINDINGS: The first pivotal randomized clinical trial, TRILUMINATE, demonstrated that T-TEER can safely reduce TR and is associated with improved health status outcomes. However, results of this trial have raised questions about whether this device can provide sufficient TR reduction to impact clinical outcomes. Orthotopic TTVR has recently gained attention with initial data suggesting near-complete TR elimination. The current review examines the technical features and anatomic limitations of the most commonly used devices for T-TEER and orthotopic TTVR, discusses the current clinical data for these devices, and offers a theoretical construct for device selection.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/instrumentación , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto
16.
Eur Heart J ; 44(44): 4650-4661, 2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-37632738

RESUMEN

BACKGROUND AND AIMS: Guideline-directed medical therapy (GDMT) is recommended before mitral valve transcatheter edge-to-edge repair (MTEER) in patients with heart failure (HF) and severe functional mitral regurgitation (FMR). Whether MTEER is being performed on the background of optimal GDMT in clinical practice is unknown. METHODS: Patients with left ventricular ejection fraction (LVEF) < 50% who underwent MTEER for FMR from 23 July 2019 to 31 March 2022 in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry were identified. Pre-procedure GDMT utilization was assessed. Cox proportional hazards models were constructed to evaluate associations between pre-MTEER therapy (no/single, double, or triple therapy) and risk of 1-year mortality or HF hospitalization (HFH). RESULTS: Among 4199 patients across 449 sites, beta-blockers, angiotensin-converting enzyme inhibitors/angiotensin receptor blockers, mineralocorticoid receptor antagonists, and angiotensin receptor-neprilysin inhibitors were used in 85.1%, 44.4%, 28.6%, and 19.9% before MTEER, respectively. Triple therapy was prescribed for 19.2%, double therapy for 38.2%, single therapy for 36.0%, and 6.5% were on no GDMT. Significant centre-level variation in the proportion of patients on pre-intervention triple therapy was observed (0%-61%; adjusted median odds ratio 1.48 [95% confidence interval (CI) 1.25-3.88]; P < .001). In patients eligible for 1-year follow-up (n = 2014; 341 sites), the composite rate of 1-year mortality or HFH was lowest in patients prescribed triple therapy (23.0%) compared with double (24.8%), single (35.7%), and no (41.1%) therapy (P < .01 comparing across groups). Associations persisted after accounting for relevant clinical characteristics, with lower risk in patients prescribed triple therapy [adjusted hazard ratio (aHR) 0.73, 95% CI .55-.97] and double therapy (aHR 0.69, 95% CI .56-.86) before MTEER compared with no/single therapy. CONCLUSIONS: Under one-fifth of patients with LVEF <50% who underwent MTEER for FMR in this US nationwide registry were prescribed comprehensive GDMT, with substantial variation across sites. Compared with no/single therapy, triple and double therapy before MTEER were independently associated with reduced risk of mortality or HFH 1 year after intervention.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Resultado del Tratamiento , Volumen Sistólico , Función Ventricular Izquierda , Insuficiencia de la Válvula Mitral/etiología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia Cardíaca/etiología , Sistema de Registros
17.
Angew Chem Int Ed Engl ; 63(5): e202316630, 2024 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-38063060

RESUMEN

Controlled assembly of nanoparticles into well-defined assembled architectures through precise manipulation of spatial arrangement and interactions allows the development of advanced mesoscale materials with tailored structures, hierarchical functionalities, and enhanced properties. Despite remarkable advancements, the controlled assembly of highly anisotropic 2Dnanosheets is significantly challenging, primarily due to the limited availability of selective edge-to-edge connectivity compared to the abundant large faces. Innovative strategies are needed to unlock the full potential of 2D-nanomaterialsin self-assembled structures with distinct and desirable properties. This research unveils the discovery of controlled self-assembly of 2D-silica nanosheets (2D-SiNSs) into hollow micron-sized soccer ball-like shells (SA-SiMS). The assembly is driven by the physical flexibility of the 2D-SiNSs and the differential electricdouble-layer charge gradient creating electrostatic bias on the edge and face regions. The resulting SA-SiMS structures exhibit high mechanical stability, even at high-temperatures, and exhibit excellent performance as catalyst support in the dry reforming of methane. The SA-SiMS structures facilitate improved mass transport, leading to enhanced reaction rates, while the thin silica shell prevents sintering of small catalyst nanocrystals, thereby preventing coke formation. This discovery sheds light on the controllable self-assembly of 2D nanomaterials and provides insights into the design and synthesis of advanced mesoscale materials with tailored properties.

18.
Rev Cardiovasc Med ; 24(5): 138, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-39076737

RESUMEN

Background: The MitraClip G4 system is the latest version of the transcatheter edge-to-edge repair (TEER) system for mitral regurgitation (MR). We aimed to investigate the impact of the new system on routine clinical practice and patient outcomes in the treatment of primary MR. Methods: Consecutive patients with primary MR who underwent TEER with either the MitraClip G2 or G4 between 2018 and 2021 were enrolled from a single center registry. Baseline clinical and echocardiographic characteristics as well as procedural and clinical outcomes up to 1 year were compared between groups. Technical and device success were defined in accordance with the Mitral Valve Academic Research Consortium criteria. Results: Among 71 patients with primary MR, 34 were treated with G2 and 37 were treated with G4. Patients treated with G4 had lower surgical risk (7.74 [5.04, 14.97] vs. 5.26 [3.98, 6.40]; p < 0.01) than those with G2. There were no significant differences in other baseline clinical variables between groups. On baseline echocardiography, MR volume and flail gap were significantly greater in the G4 group than in the G2 group (regurgitant volume: 63 [41-76] mL vs. 68 [62-84] mL; p = 0.04, flail gap: 4.5 [3.5-5.5] mm vs. 5.4 [4.5-7.1] mm; p = 0.04). Technical success was achieved in over 95% of both groups with no significant difference (p > 0.99). Device success was achieved in 61.8% of the G2 group, while in 70.3% of the G4 group (p = 0.47). Post-procedural MR severity was comparable (p = 0.42) and there was no significant difference in the occurrence of mitral stenosis (p = 0.61) between groups. Among patients who reached 1-year follow-up (n = 54), there was no significant difference between groups in a composite endpoint of death or heart failure rehospitalization (10.5% vs. 20.2%; HR 0.61; 95% CI 0.17-2.22; p = 0.45). Residual heart failure symptoms (NYHA ≥ 3) at 1 year were observed in 3.7% of the G2 group, while no patient in the G4 group (p > 0.99). Conclusions: The MitraClip G4 system achieved comparable device outcomes to the early-generation device (G2), despite treating more severe primary MR with a larger flail gap.

19.
Rev Cardiovasc Med ; 24(1): 15, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39076866

RESUMEN

Background: Transcatheter edge-to-edge repair of mitral valve (M-TEER) is reasonable consideration in symptomatic patients with severe degenerative mitral regurgitation (MR) who are at high or prohibitive risk of surgical repair or replacement. In symptomatic patients on maximally tolerated medical therapy with severe secondary MR from left ventricular systolic dysfunction, M-TEER is reasonable therapeutic option. Methods: In this review, we present a comprehensive overview of the most recent literature and considerations for M-TEER in patients excluded from key trials. These include patients with cardiogenic shock, acute ischemic MR, atrial functional MR, failed surgical mitral valve prosthesis and pulmonary hypertension. Conclusions: M-TEER is feasible and a reasonable alternative option for these patient populations with a significant clinical benefit. However, randomized clinical trials are needed to ascertain findings from these observational studies.

20.
Catheter Cardiovasc Interv ; 101(3): 596-604, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36740240

RESUMEN

BACKGROUND: Limited data exist regarding the performance of the Society of Thoracic Surgeons (STS) risk score among transcatheter mitral edge-to-edge repair (TEER) patients. OBJECTIVE: Evaluate STS score accuracy, and the incremental value of post-procedural left atrial pressure (LAP). METHODS: A retrospective analysis of TEER patients between 2013 and 2020. Patients were allocated into 3 groups: high (≥8% [n = 298, 31%]), intermediate (4%-8% [n = 318, 33%]), and low (<4% [n = 344, 36%]). Primary outcomes included 1-year mortality or cardiovascular hospitalizations. Cox proportional hazards regression modeling was used to determine the hazard ratio of the primary outcome, and STS score accuracy was assessed by receiver operating characteristic. A spline curve was used to display the relationship between LAP and the primary endpoint. Continuous net reclassification improvement (NRI) was used to determine the incremental value of LAP. RESULTS: We included 960 patients, primarily elderly (79 [70-85]), with a median STS risk of 5.6 (3-9). High-risk patients were older (83 [75-89], 81 [74-87], 72 [64-79], p < 0.001), and had more comorbidities compared to intermediate and low-risk groups. Upon Cox regression, STS score (high vs. low: HR 2.5 [1.7-3.8]; Intermediate vs. low: HR 1.8 [1.2-2.7] and LAP HR 1.03 [1.01-1.06], p = 0.007) were associated with the outcome. C statistics analysis revealed low accuracy of the STS score (AUC-0.61 [0.58-0.65, p < 0.001]). Continuous NRI analysis indicated an improvement in risk prediction of 17% (6.9-26.2), p < 0.001. CONCLUSION: STS risk score has low accuracy in predicting clinical outcomes after TEER. Adding LAP measurements can improve reclassification and identify those prone to adverse outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cirujanos , Humanos , Anciano , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Presión Atrial , Estudios Retrospectivos , Resultado del Tratamiento , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA