Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.427
Filtrar
Más filtros

Intervalo de año de publicación
1.
J Infect Dis ; 229(1): 252-261, 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-37882788

RESUMEN

BACKGROUND: Delayed diagnosis and improper therapy for intraocular infections usually result in poor prognosis. Due to limitations of conventional culture and polymerase chain reaction methods, most causative pathogens cannot be identified from vitreous humor (VH) or aqueous humor (AH) samples with limited volume. METHODS: Patients with suspected intraocular infections were enrolled from January 2019 to August 2021. Metagenomic next-generation sequencing (mNGS) was used to detected causative pathogens. RESULTS: This multicenter prospective study enrolled 488 patients, from whom VH (152) and AH (336) samples were respectively collected and analyzed using mNGS of cell-free DNA (cfDNA). Taking final comprehensive clinical diagnosis as the gold standard, there were 39 patients with indefinite final diagnoses, whereas 288 and 161 patients were diagnosed as definite infectious and noninfectious diseases, respectively. Based on clinical adjudication, the sensitivity (92.2%) and total coincidence rate (81.3%) of mNGS using VH samples were slightly higher than those of mNGS using AH samples (85.4% and 75.4%, respectively). CONCLUSIONS: Using mNGS of cfDNA, an era with clinical experience for more rapid, independent, and impartial diagnosis of bacterial and other intraocular infections can be expected.


Asunto(s)
Ácidos Nucleicos Libres de Células , Infecciones del Ojo , Humanos , Humor Acuoso , Ácidos Nucleicos Libres de Células/genética , Estudios Prospectivos , Secuenciación de Nucleótidos de Alto Rendimiento , Metagenómica , Sensibilidad y Especificidad
2.
Am J Physiol Cell Physiol ; 326(5): C1505-C1519, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38557355

RESUMEN

Glaucoma is a blinding disease. Reduction of intraocular pressure (IOP) is the mainstay of treatment, but current drugs show side effects or become progressively ineffective, highlighting the need for novel compounds. We have synthesized a family of perhydro-1,4-oxazepine derivatives of digoxin, the selective inhibitor of Na,K-ATPase. The cyclobutyl derivative (DcB) displays strong selectivity for the human α2 isoform and potently reduces IOP in rabbits. These observations appeared consistent with a hypothesis that in ciliary epithelium DcB inhibits the α2 isoform of Na,K-ATPase, which is expressed strongly in nonpigmented cells, reducing aqueous humor (AH) inflow. This paper extends assessment of efficacy and mechanism of action of DcB using an ocular hypertensive nonhuman primate model (OHT-NHP) (Macaca fascicularis). In OHT-NHP, DcB potently lowers IOP, in both acute (24 h) and extended (7-10 days) settings, accompanied by increased aqueous humor flow rate (AFR). By contrast, ocular normotensive animals (ONT-NHP) are poorly responsive to DcB, if at all. The mechanism of action of DcB has been analyzed using isolated porcine ciliary epithelium and perfused enucleated eyes to study AH inflow and AH outflow facility, respectively. 1) DcB significantly stimulates AH inflow although prior addition of 8-Br-cAMP, which raises AH inflow, precludes additional effects of DcB. 2) DcB significantly increases AH outflow facility via the trabecular meshwork (TM). Taken together, the data indicate that the original hypothesis on the mechanism of action must be revised. In the OHT-NHP, and presumably other species, DcB lowers IOP by increasing AH outflow facility rather than by decreasing AH inflow.NEW & NOTEWORTHY When applied topically, a cyclobutyl derivative of digoxin (DcB) potently reduces intraocular pressure in an ocular hypertensive nonhuman primate model (Macaca fascicularis), associated with increased aqueous humor (AH) flow rate (AFR). The mechanism of action of DcB involves increased AH outflow facility as detected in enucleated perfused porcine eyes and, in parallel, increased (AH) inflow as detected in isolated porcine ciliary epithelium. DcB might have potential as a drug for the treatment of open-angle human glaucoma.


Asunto(s)
Humor Acuoso , Digoxina , Presión Intraocular , Macaca fascicularis , Hipertensión Ocular , Animales , Presión Intraocular/efectos de los fármacos , Digoxina/farmacología , Humor Acuoso/metabolismo , Humor Acuoso/efectos de los fármacos , Hipertensión Ocular/tratamiento farmacológico , Hipertensión Ocular/fisiopatología , Hipertensión Ocular/metabolismo , Modelos Animales de Enfermedad , Glaucoma/tratamiento farmacológico , Glaucoma/metabolismo , Glaucoma/fisiopatología , Conejos , Humanos , Cuerpo Ciliar/efectos de los fármacos , Cuerpo Ciliar/metabolismo , ATPasa Intercambiadora de Sodio-Potasio/metabolismo , ATPasa Intercambiadora de Sodio-Potasio/antagonistas & inhibidores , Masculino , Malla Trabecular/efectos de los fármacos , Malla Trabecular/metabolismo
3.
Am J Physiol Cell Physiol ; 327(2): C403-C414, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38881423

RESUMEN

Aqueous humor drainage from the anterior eye determines intraocular pressure (IOP) under homeostatic and pathological conditions. Swelling of the trabecular meshwork (TM) alters its flow resistance but the mechanisms that sense and transduce osmotic gradients remain poorly understood. We investigated TM osmotransduction and its role in calcium and chloride homeostasis using molecular analyses, optical imaging, and electrophysiology. Anisosmotic conditions elicited proportional changes in TM cell volume, with swelling, but not shrinking, evoking elevations in intracellular calcium concentration [Ca2+]TM. Hypotonicity-evoked calcium signals were sensitive to HC067047, a selective blocker of TRPV4 channels, whereas the agonist GSK1016790A promoted swelling under isotonic conditions. TRPV4 inhibition partially suppressed hypotonicity-induced volume increases and reduced the magnitude of the swelling-induced membrane current, with a substantial fraction of the swelling-evoked current abrogated by Cl- channel antagonists 4,4'-diisothiocyanato-2,2'-stilbenedisulfonic acid (DIDS) and niflumic acid. The transcriptome of volume-sensing chloride channel candidates in primary human was dominated by ANO6 transcripts, with moderate expression of ANO3, ANO7, and ANO10 transcripts and low expression of LTTRC genes that encode constituents of the volume-activated anion channel. Imposition of 190 mosM but not 285 mosM hypotonic gradients increased conventional outflow in mouse eyes. TRPV4-mediated cation influx thus works with Cl- efflux to sense and respond to osmotic stress, potentially contributing to pathological swelling, calcium overload, and intracellular signaling that could exacerbate functional disturbances in inflammatory disease and glaucoma.NEW & NOTEWORTHY Intraocular pressure is dynamically regulated by the flow of aqueous humor through paracellular passages within the trabecular meshwork (TM). This study shows hypotonic gradients that expand the TM cell volume and reduce the outflow facility in mouse eyes. The swelling-induced current consists of TRPV4 and chloride components, with TRPV4 as a driver of swelling-induced calcium signaling. TRPV4 inhibition reduced swelling, suggesting a novel treatment for trabeculitis and glaucoma.


Asunto(s)
Tamaño de la Célula , Canales de Cloruro , Canales Catiónicos TRPV , Malla Trabecular , Canales Catiónicos TRPV/metabolismo , Canales Catiónicos TRPV/genética , Canales Catiónicos TRPV/agonistas , Malla Trabecular/metabolismo , Malla Trabecular/efectos de los fármacos , Canales de Cloruro/metabolismo , Canales de Cloruro/genética , Animales , Ratones , Tamaño de la Célula/efectos de los fármacos , Humanos , Calcio/metabolismo , Ratones Endogámicos C57BL , Presión Osmótica , Señalización del Calcio/efectos de los fármacos , Masculino , Presión Intraocular/fisiología , Presión Intraocular/efectos de los fármacos , Células Cultivadas , Femenino , Leucina/análogos & derivados , Morfolinas , Pirroles , Sulfonamidas
4.
Glia ; 72(9): 1555-1571, 2024 09.
Artículo en Inglés | MEDLINE | ID: mdl-38829008

RESUMEN

As one of the top causes of blindness worldwide, glaucoma leads to diverse optic neuropathies such as degeneration of retinal ganglion cells (RGCs). It is widely accepted that the level of intraocular pressure (IOP) is a major risk factor in human glaucoma, and reduction of IOP level is the principally most well-known method to prevent cell death of RGCs. However, clinical studies show that lowering IOP fails to prevent RGC degeneration in the progression of glaucoma. Thus, a comprehensive understanding of glaucoma pathological process is required for developing new therapeutic strategies. In this study, we provide functional and histological evidence showing that optic nerve defects occurred before retina damage in an ocular hypertension glaucoma mouse model, in which oligodendroglial lineage cells were responsible for the subsequent neuropathology. By treatment with clemastine, an Food and Drug Administration (FDA)-approved first-generation antihistamine medicine, we demonstrate that the optic nerve and retina damages were attenuated via promoting oligodendrocyte precursor cell (OPC) differentiation and enhancing remyelination. Taken together, our results reveal the timeline of the optic neuropathies in glaucoma and highlight the potential role of oligodendroglial lineage cells playing in its treatment. Clemastine may be used in future clinical applications for demyelination-associated glaucoma.


Asunto(s)
Clemastina , Glaucoma , Ratones Endogámicos C57BL , Remielinización , Retina , Animales , Clemastina/farmacología , Clemastina/uso terapéutico , Glaucoma/patología , Glaucoma/tratamiento farmacológico , Retina/patología , Retina/efectos de los fármacos , Remielinización/efectos de los fármacos , Remielinización/fisiología , Ratones , Nervio Óptico/efectos de los fármacos , Nervio Óptico/patología , Modelos Animales de Enfermedad , Enfermedades del Nervio Óptico/tratamiento farmacológico , Enfermedades del Nervio Óptico/patología , Oligodendroglía/efectos de los fármacos , Oligodendroglía/patología , Células Ganglionares de la Retina/efectos de los fármacos , Células Ganglionares de la Retina/patología
5.
Small ; 20(24): e2309785, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38377279

RESUMEN

Wearable soft contact lens sensors for continuous and nondestructive intraocular pressure (IOP) monitoring are highly desired as glaucoma and postoperative myopia patients grow, especially as the eyestrain crowd increases. Herein, a smart closed-loop system is presented that combines a Ti3C2Tx MXene-based soft contact lens (MX-CLS) sensor, wireless data transmission units, display, and warning components to realize continuous and nondestructive IOP monitoring/real-time display. The fabricated MX-CLS device exhibits an extremely high sensitivity of 7.483 mV mmHg-1, good linearity on silicone eyeballs, excellent stability under long-term pressure-release measurement, sufficient transparency with 67.8% transmittance under visible illumination, and superior biocompatibility with no discomfort when putting the MX-CLS sensor onto the Rabbit eyes. After integrating with the wireless module, users can realize real-time monitoring and warning of IOP via smartphones, the demonstrated MX-CLS device together with the IOP monitoring/display system opens up promising platforms for Ti3C2Tx materials as the base for multifunctional contact lens-based sensors and continuous and nondestructive IOP measurement system.


Asunto(s)
Lentes de Contacto Hidrofílicos , Presión Intraocular , Titanio , Presión Intraocular/fisiología , Animales , Conejos , Titanio/química , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación
6.
J Transl Med ; 22(1): 791, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39198903

RESUMEN

Glaucoma, a blinding eye disease with optic neuropathy, is usually associated with elevated intraocular pressure (IOP). The currently available pharmacological and surgical treatments for glaucoma have significant limitations and side effects, which include systemic reactions to medications, patient non-compliance, eye infections, surgical device failure, and damage to the eye. Here, we present Sensor-Actuator-Modulator (SAM), an engineered double mutant version of the bacterial stretch-activated mechanosensitive channel of large conductance (MscL) that directly senses tension in the membrane lipid bilayer of cells and in response, transiently opens its large nonspecific pore to release cytoplasmic fluid. The heterologously expressed mechanosensitive SAM channel acts as a tension-activated pressure release valve in trabeculocytes. In the trabecular meshwork (TM), SAM is activated by membrane stretch caused by elevated IOP. We have identified several SAM variants that are activated at physiologically relevant pressures. Using this barogenetic technology, we have demonstrated that SAM is functional in cultured TM cells, and successfully transduced in vivo in TM cells by use of AAV2/8. Further, it is effective in enhancing aqueous humor outflow facility leading to lowering the IOP in a mouse model of ocular hypertension.


Autoregulation of intraocular pressure via expression of a mechanosensitive channel of large conductance in trabecular meshwork serves as a mutation-agnostic gene therapy for glaucoma.


Asunto(s)
Humor Acuoso , Terapia Genética , Glaucoma de Ángulo Abierto , Animales , Glaucoma de Ángulo Abierto/genética , Glaucoma de Ángulo Abierto/terapia , Humor Acuoso/metabolismo , Humanos , Malla Trabecular/metabolismo , Presión Intraocular , Ratones
7.
Ophthalmology ; 131(10): 1196-1206, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38754556

RESUMEN

PURPOSE: To report the cumulative incidence of complications and to describe refractive error and visual acuity (VA) outcomes in children undergoing secondary intraocular lens (IOL) implantation after previous surgery for nontraumatic cataract. DESIGN: Pediatric cataract registry. PARTICIPANTS: Eighty children (108 eyes: 60 bilateral, 48 unilateral) undergoing lensectomy at younger than 13 years of age. METHODS: Annual data collection from medical record review through 5 years after lensectomy. MAIN OUTCOME MEASURES: Cumulative incidence of newly emergent complications after secondary IOL implantation; refractive error and VA by 5 years after lensectomy. RESULTS: Median follow-up after secondary IOL implantation was 2.7 years (interquartile range [IQR], 0.8-3.3 years; range, 0.6-5.0 years) for bilateral and 2.1 years (range, 0.5-6.4 years) for unilateral cases. A common complication after secondary IOL implantation was a glaucoma-related adverse event (GRAE; glaucoma or glaucoma suspect); the cumulative incidence was 17% (95% confidence interval [CI], 3%-29%) in bilateral cases and 12% (95% CI, 0%-23%) in unilateral cases. The cumulative incidence of surgery for visual axis opacification was 2% (95% CI, 0%-7%) for bilateral cases and 4% (95% CI, 0%-10%) for unilateral cases. The median prediction error within 90 days of implantation was 0.88 diopter (D; IQR, -0.50 to +3.00 D) less hyperopic than intended among 21 eyes for bilateral cases and 1.50 D (IQR, -0.25 to +2.38 D) less among 19 unilateral cases. The median spherical equivalent refractive error at 5 years (at a median of 5.1 years of age) in eyes receiving a secondary IOL was +0.50 D (IQR, -2.38 to +2.94 D) for 48 bilateral cases and +0.06 D (IQR, -2.25 to +0.75 D) for 22 unilateral cases. Median monocular VA at 5 years was 20/63 (IQR, 20/50-20/100) for bilateral cases (n = 42) and 20/400 (IQR, 20/160-20/800) for unilateral cases (n = 33). CONCLUSIONS: Eyes with secondary IOL implantation have a risk of developing new GRAEs. Five years after lensectomy (approximately 2.5 years after secondary IOL implantation), the average refractive error was less hyperopic than desired given the anticipated further myopic shift before refraction stabilizes. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Afaquia Poscatarata , Implantación de Lentes Intraoculares , Complicaciones Posoperatorias , Errores de Refracción , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Preescolar , Femenino , Masculino , Niño , Incidencia , Afaquia Poscatarata/fisiopatología , Afaquia Poscatarata/cirugía , Errores de Refracción/fisiopatología , Errores de Refracción/etiología , Estudios de Seguimiento , Lactante , Extracción de Catarata/efectos adversos , Sistema de Registros , Refracción Ocular/fisiología , Reoperación , Catarata/congénito , Adolescente , Estudios Retrospectivos
8.
Ophthalmology ; 131(9): 1021-1032, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38423216

RESUMEN

PURPOSE: To evaluate the safety and intraocular pressure (IOP)-lowering efficacy of 2 models of the travoprost intraocular implant (fast-eluting [FE] and slow-eluting [SE] types) from 1 of 2 phase 3 trials (the GC-010 trial). DESIGN: Multicenter, randomized, double-masked, sham-controlled, noninferiority trial. PARTICIPANTS: Patients with open-angle glaucoma or ocular hypertension having an unmedicated baseline mean diurnal IOP (average of 8 am, 10 am, and 4 pm time points) of ≥ 21 mmHg, and IOP of ≤ 36 mmHg at each of the 8 am, 10 am, and 4 pm timepoints at baseline. METHODS: Study eyes were randomized to the travoprost intraocular implant (FE implant [n = 200] or SE implant [n = 197] model) or to timolol ophthalmic solution 0.5% twice daily (n = 193). MAIN OUTCOME MEASURES: The primary outcome was mean change from baseline IOP in the study eye at 8 am and 10 am, at each of day 10, week 6, and month 3. Safety outcomes included adverse events (AEs) and ophthalmic assessments. RESULTS: Mean IOP reduction from baseline over the 6 time points ranged from 6.6 to 8.4 mmHg for the FE implant group, from 6.6 to 8.5 mmHg for the SE implant group, and from 6.5 to 7.7 mmHg for the timolol group. The primary efficacy end point was met; the upper limit of the 95% confidence interval of the difference between the implant groups and the timolol group was < 1 mmHg at all 6 time points. Study eye AEs, most of mild or moderate severity, were reported in 21.5%, 27.2%, and 10.8% of patients in the FE implant, SE implant, and timolol groups, respectively. The most common AEs included iritis (FE implant, 0.5%; SE implant, 5.1%), ocular hyperemia (FE implant, 3.0%; SE implant, 2.6%), reduced visual acuity (FE implant, 1.0%; SE implant, 4.1%; timolol, 0.5%), and IOP increased (FE implant, 3.5%; SE implant, 2.6%; timolol, 2.1%). One serious study eye AE occurred (endophthalmitis). CONCLUSIONS: The travoprost intraocular implant demonstrated robust IOP reduction over the 3-month primary efficacy evaluation period after a single administration. The IOP-lowering efficacy in both implant groups was statistically and clinically noninferior to that in the timolol group, with a favorable safety profile. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Antihipertensivos , Implantes de Medicamentos , Glaucoma de Ángulo Abierto , Presión Intraocular , Hipertensión Ocular , Tonometría Ocular , Travoprost , Humanos , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Glaucoma de Ángulo Abierto/fisiopatología , Presión Intraocular/efectos de los fármacos , Presión Intraocular/fisiología , Hipertensión Ocular/tratamiento farmacológico , Hipertensión Ocular/fisiopatología , Travoprost/uso terapéutico , Travoprost/administración & dosificación , Antihipertensivos/administración & dosificación , Antihipertensivos/uso terapéutico , Antihipertensivos/efectos adversos , Femenino , Masculino , Método Doble Ciego , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Agudeza Visual/fisiología , Timolol/administración & dosificación , Timolol/uso terapéutico , Timolol/efectos adversos , Soluciones Oftálmicas , Anciano de 80 o más Años , Adulto
9.
Ophthalmology ; 131(4): 403-411, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37858872

RESUMEN

PURPOSE: To assess risk factors for worse visual acuity (VA) outcomes after intraocular lens (IOL) exchange, and the most common postsurgical complications. DESIGN: Retrospective cohort study. PARTICIPANTS: Eyes from patients 18 years of age and older in the IRIS® Registry (Intelligent Research in Sight) that underwent IOL exchange in the United States between 2013 and 2019. METHODS: Vision improvement compared with baseline was determined at 1 year after surgery. A multivariable generalized estimating equation model adjusting for demographic factors and baseline vision was used to identify factors associated with VA worse than 20/40 at 1 year. MAIN OUTCOME MEASURES: Visual outcomes and postoperative complications after lens exchange. RESULTS: A total of 46 063 procedures (n = 41 925 unique patients) were included in the analysis. Overall, VA improved from a mean ± standard deviation (SD) of 0.53 ± 0.58 logarithm of the minimum angle of resolution (logMAR; Snellen equivalent, 20/70) before surgery to a mean ± SD of 0.31 ± 0.40 logMAR (Snellen equivalent, 20/40) at 1 year. Among eyes with VA recorded at both baseline and 1 year after surgery, 60.5% achieved VA of 20/40 or better at 1 year. Vision of worse than 20/40 at 1 year was associated with greater age (odds ratio [OR], 1.16 per 5-year increase; 95% confidence interval [CI], 1.14-1.18) and higher logMAR baseline VA (OR, 1.14 per 0.1-logMAR increase; 95% CI, 1.14-1.15), as well as Black or African American (OR, 1.96; 95% CI, 1.68-2.28), Hispanic (OR, 1.82; 95% CI, 1.59-2.08), and Asian (OR, 1.48; 95% CI, 1.21-1.81) race or ethnicity versus White race, Medicaid (OR, 1.78; 95% CI, 1.40-2.25) versus private insurance, smoking history (OR, 1.22; 95% CI, 1.11-1.35), and concurrent anterior (OR, 1.65; 95% CI, 1.51-1.81) and posterior (OR, 1.53; 95% CI, 1.41-1.66) vitrectomy versus no vitrectomy. Female sex was associated with better VA at 1 year. At 1 year, epiretinal membrane (10.9%), mechanical lens complication (9.4%), and dislocation of the replacement lens (7.1%) were the most common complications. CONCLUSIONS: In this large national cohort, the annual number of IOL exchanges rose steadily over time. Vision improved in 60.2% of patients; worse visual outcomes were associated with greater age, worse baseline vision, Black race, Hispanic ethnicity, Medicaid insurance, smoking, and concurrent vitrectomy. Epiretinal membrane was the most common complication. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Membrana Epirretinal , Lentes Intraoculares , Humanos , Femenino , Adolescente , Adulto , Implantación de Lentes Intraoculares/efectos adversos , Estudios Retrospectivos , Membrana Epirretinal/etiología , Agudeza Visual , Sistema de Registros
10.
Ophthalmology ; 131(7): 836-844, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38215990

RESUMEN

TOPIC: Sympathetic ophthalmia (SO) is a rare bilateral granulomatous panuveitis that can present after trauma or intraocular surgery (IOS). The incidence of SO after IOS varies among studies. The purpose of this review was to determine the incidence proportion of SO after IOS. CLINICAL RELEVANCE: The incidence proportion of SO after IOS can provide physicians and patients with information on the risk of SO during the consent process before surgery. METHODS: In this systematic review and meta-analysis, MEDLINE, EMBASE, and Cochrane databases were searched from inception to January 1, 2023 for population-based studies of SO after IOS. Two reviewers independently screened the results. Random-effects meta-analyses calculated incidence proportion. Subgroup analysis assessed SO incidence based on IOS type and technological advancements. Study quality and bias were assessed using the Newcastle-Ottawa scale and the Grades of Recommendation, Assessment, Development, and Evaluation framework. RESULTS: The final meta-analyses included 19 studies, with 118 cases of SO occurring after 505 178 inciting events. The estimated overall incidence proportion of SO after IOS was 0.061% (95% confidence interval [CI], 0.033%-0.111%; I2 = 83%), and the estimated incidence rate was 9.24 cases per 100 000 person-years (95% CI, 4.03-21.19; I2 = 88%). The average study duration across these studies was 10.8 years. Within the reviewed literature, SO after glaucoma and vitreoretinal IOS was studied most, with 9 and 6 studies, respectively. Observed differences in incidence between glaucoma (0.098%; 95% CI, 0.042%-0.232%; I2 = 40%) and vitreoretinal (0.043%; 95% CI, 0.022%-0.085%; I2 = 88%) IOS were not statistically significant (P = 0.14). Also, no significant difference was found in the incidence proportion before and after 1975, when modern intraocular surgical techniques emerged (0.060% vs. 0.058%; P = 0.98). The outcome measures showed low-certainty Grades of Recommendation, Assessment, Development, and Evaluation evidence. DISCUSSION: Sympathetic ophthalmia after IOS is rare and might not have changed over the past 5 decades. The estimated incidence proportion of SO may be useful during the consent process before surgery. Also, no significant difference may exist in the incidence of SO between glaucoma and vitreoretinal IOS, based on low-certainty evidence. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.


Asunto(s)
Oftalmía Simpática , Humanos , Oftalmía Simpática/epidemiología , Oftalmía Simpática/etiología , Incidencia , Complicaciones Posoperatorias/epidemiología , Procedimientos Quirúrgicos Oftalmológicos/efectos adversos
11.
Ophthalmology ; 131(3): 383-392, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38149945

RESUMEN

PURPOSE: To review the published literature evaluating the visual and refractive outcomes and rotational stability of eyes implanted with toric monofocal intraocular lenses (IOLs) for the correction of keratometric astigmatism during cataract surgery and to compare those outcomes with outcomes of eyes implanted with nontoric monofocal IOLs and other astigmatism management methods performed during cataract surgery. This assessment was restricted to the toric IOLs available in the United States. METHODS: A literature search of English-language publications in the PubMed database was last conducted in July 2022. The search identified 906 potentially relevant citations, and after review of the abstracts, 63 were selected for full-text review. Twenty-one studies ultimately were determined to be relevant to the assessment criteria and were selected for inclusion. The panel methodologist assigned each a level of evidence rating; 12 studies were rated level I and 9 studies were rated level II. RESULTS: Eyes implanted with toric IOLs showed excellent postoperative uncorrected distance visual acuity (UCDVA), reduction of postoperative refractive astigmatism, and good rotational stability. Uncorrected distance visual acuity was better and postoperative cylinder was lower with toric IOLs, regardless of manufacturer, when compared with nontoric monofocal IOLs. Correcting pre-existing astigmatism with toric IOLs was more effective and predictable than using corneal relaxing incisions (CRIs), especially in the presence of higher magnitudes of astigmatism. CONCLUSIONS: Toric monofocal IOLs are effective in neutralizing pre-existing corneal astigmatism at the time of cataract surgery and result in better UCDVA and significant reductions in postoperative refractive astigmatism compared with nontoric monofocal IOLs. Toric IOLs result in better astigmatic correction than CRIs, particularly at high magnitudes of astigmatism. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Astigmatismo , Catarata , Lentes Intraoculares , Oftalmología , Facoemulsificación , Humanos , Astigmatismo/cirugía , Implantación de Lentes Intraoculares , Diseño de Prótesis , Refracción Ocular
12.
Ophthalmology ; 131(4): 445-457, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37914042

RESUMEN

PURPOSE: To evaluate the influence of a capsular tension ring (CTR) on rotational stability, decentration, tilt, and axial stability of an 11.0-mm plate haptic intraocular lens (IOL). DESIGN: Intraindividual, randomized, double-masked, controlled clinical trial. PARTICIPANTS: Patients scheduled for sequential same-day bilateral cataract surgery. METHODS: All patients were randomized to receive a CTR and a plate haptic IOL in one eye and a plate haptic IOL in the fellow eye only. Intraocular lens axis assessment was performed at the end of surgery, 1 hour, 1 week, 1 month, and 6 months using a high-precision evaluation method. Decentration and tilt of the crystalline and pseudophakic lenses were assessed before surgery and at 1 week and 6 months using an anterior segment OCT. MAIN OUTCOME MEASURES: Rotational stability from the end of surgery to 6 months and at all follow-up visits, decentration and tilt at 6 months, and differences in axial shift between 1 week and 6 months. RESULTS: One hundred thirty eyes of 65 patients were included in the study. Absolute rotation from the end of surgery to 6 months was 2.8 ± 3.9° and 3.2 ± 5.3° for the CTR and control groups, respectively (P = 0.613). Intraocular lens decentration and IOL tilt at 6 months were 0.29 ± 0.1 mm and 0.24 ± 0.1 mm and 6.7 ± 2.8° and 5.6 ± 1.6° for the CTR and control groups, respectively (P = 0.058; P < 0.01). A posterior IOL shift of 0.31 ± 0.31 mm and 0.19 ± 0.14 mm was observed in the CTR and control groups, respectively. CONCLUSIONS: Concomitant implantation of a CTR and a plate haptic IOL did not improve the overall rotational stability of the IOL compared with the control group. Against expectations, higher values of decentration, tilt, and axial shift were observed in the CTR group. The simultaneous use of a CTR and a plate haptic IOL in the absence of zonular weakness at the time of cataract surgery should be considered with caution. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Catarata , Cápsula del Cristalino , Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares/métodos , Tecnología Háptica , Facoemulsificación/métodos , Cápsula del Cristalino/cirugía
13.
Ophthalmology ; 131(7): 780-789, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38246424

RESUMEN

PURPOSE: To evaluate risk factors for intraocular pressure (IOP) spike after cataract surgery using the IRIS® Registry (Intelligent Research in Sight). DESIGN: Retrospective clinical cohort study. PARTICIPANTS: Adults with IRIS Registry data who underwent stand-alone phacoemulsification from January 1, 2013, through September 30, 2019. METHODS: Intraocular pressure spike was defined as postoperative IOP of > 30 mmHg and > 10 mmHg from the baseline within the first postoperative week. Odds ratios (ORs) for demographic and clinical characteristics were calculated with univariable and multivariable logistic regression analyses. MAIN OUTCOME MEASURES: Incidence and OR of IOP spike. RESULTS: We analyzed data from 1 191 034 eyes (patient mean age, 71.3 years; 61.2% female sex; and 24.8% with glaucoma). An IOP spike occurred in 3.7% of all eyes, 5.2% of eyes with glaucoma, and 3.2% of eyes without glaucoma (P < 0.0001). Multivariable analyses of all eyes indicated a greater risk of IOP spike with higher baseline IOP (OR, 1.57 per 3 mmHg), male sex (OR, 1.79), glaucoma (OR, 1.20), Black race (OR, 1.39 vs. Asian and 1.21 vs. Hispanic), older age (OR, 1.07 per 10 years), and complex surgery coding (OR, 1.22; all P < 0.0001). Diabetes (OR, 0.90) and aphakia after surgery (OR, 0.60) seemed to be protective against IOP spike (both P < 0.0001). Compared with glaucoma suspects, ocular hypertension (OR, 1.55), pigmentary glaucoma (OR, 1.56), and pseudoexfoliative glaucoma (OR, 1.52) showed a greater risk of IOP spike and normal-tension glaucoma (OR, 0.55), suspected primary angle closure (PAC; OR, 0.67), and PAC glaucoma (OR, 0.81) showed less risk (all P < 0.0001). Using more baseline glaucoma medications was associated with IOP spike (OR, 1.18 per medication), whereas topical ß-blocker use (OR, 0.68) was protective (both P < 0.0001). CONCLUSIONS: Higher baseline IOP, male sex, glaucoma, Black race, older age, and complex cataract coding were associated with early postoperative IOP spike, whereas diabetes and postoperative aphakia were protective against a spike after stand-alone phacoemulsification. Glaucomatous eyes demonstrated different risk profiles dependent on glaucoma subtype. The findings may help surgeons to stratify and mitigate the risk of IOP spike after cataract surgery. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Presión Intraocular , Facoemulsificación , Sistema de Registros , Humanos , Masculino , Presión Intraocular/fisiología , Femenino , Anciano , Estudios Retrospectivos , Factores de Riesgo , Persona de Mediana Edad , Anciano de 80 o más Años , Tonometría Ocular , Incidencia , Complicaciones Posoperatorias , Implantación de Lentes Intraoculares , Hipertensión Ocular/fisiopatología , Hipertensión Ocular/etiología , Glaucoma/fisiopatología , Glaucoma/cirugía
14.
Ophthalmology ; 131(1): 37-47, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37702635

RESUMEN

PURPOSE: To review the current published literature for high-quality studies on the use of selective laser trabeculoplasty (SLT) for the treatment of glaucoma. This is an update of the Ophthalmic Technology Assessment titled, "Laser Trabeculoplasty for Open-Angle Glaucoma," published in November 2011. METHODS: Literature searches in the PubMed database in March 2020, September 2021, August 2022, and March 2023 yielded 110 articles. The abstracts of these articles were examined to include those written since November 2011 and to exclude reviews and non-English articles. The panel reviewed 47 articles in full text, and 30 were found to fit the inclusion criteria. The panel methodologist assigned a level I rating to 19 studies and a level II rating to 11 studies. RESULTS: Data in the level I studies support the long-term effectiveness of SLT as primary treatment or as a supplemental therapy to glaucoma medications for patients with open-angle glaucoma. Several level I studies also found that SLT and argon laser trabeculoplasty (ALT) are equivalent in terms of safety and long-term efficacy. Level I evidence indicates that perioperative corticosteroid and nonsteroidal anti-inflammatory drug eye drops do not hinder the intraocular pressure (IOP)-lowering effect of SLT treatment. The impact of these eye drops on lowering IOP differed in various studies. No level I or II studies exist that determine the ideal power settings for SLT. CONCLUSIONS: Based on level I evidence, SLT is an effective long-term option for the treatment of open-angle glaucoma and is equivalent to ALT. It can be used as either a primary intervention, a replacement for medication, or an additional therapy with glaucoma medications. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Oftalmología , Trabeculectomía , Humanos , Glaucoma/cirugía , Glaucoma de Ángulo Abierto/cirugía , Rayos Láser , Soluciones Oftálmicas , Malla Trabecular/cirugía , Estados Unidos
15.
Ophthalmology ; 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39127407

RESUMEN

Minimally invasive glaucoma surgery (MIGS) refers to a group of procedures generally characterized by an ab interno approach, minimal trauma to ocular tissue, moderate efficacy, an excellent safety profile, and rapid recovery. The number of MIGS procedures continues to increase, and their use has become widespread among glaucoma and cataract specialists. Standardization of the methodology and reporting of clinical endpoints in MIGS investigations enhances interpretation and comparison across different studies. The assessment of surgical interventions not only should consider statistical significance, but also whether the outcome is meaningful to patients. Minimal clinically important difference (MCID) is defined as the smallest change in a treatment outcome that is considered beneficial for an individual patient and prompts a change in their clinical management. Expert consensus is an accepted approach to determine the MCID. The American Academy of Ophthalmology's Glaucoma Preferred Practice Pattern® Committee is an expert panel that develops guidelines identifying characteristics and components of quality eye care. The Committee recommends that the cumulative probability of surgical success at 2 years with Kaplan-Meier survival analysis be used as the primary efficacy endpoint in MIGS studies. The Committee suggests that surgical success for standalone MIGS be defined as intraocular pressure (IOP) of 21 mmHg or less and reduced by 20% or more from baseline without an increase in glaucoma medications, additional laser or incisional glaucoma surgery, loss of light perception vision, or hypotony. The proposed MCID for the cumulative probability of success of standalone MIGS at 2 years is 50%. The panel recommends that surgical success for MIGS combined with cataract extraction with intraocular lens implantation (CE-IOL) be defined as a decrease in glaucoma medical therapy of 1 medication or more from baseline without an increase in IOP or IOP of 21 mmHg or less and reduced by 20% or more from baseline without an increase in glaucoma medications, additional laser or incisional glaucoma surgery, loss of light perception vision, or hypotony. The suggested MCID for the cumulative probability of success for MIGS combined with CE-IOL at 2 years is 65%. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

16.
Ophthalmology ; 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39128550

RESUMEN

PURPOSE: We used a polygenic risk score (PRS) to identify high-risk groups for primary open-angle glaucoma (POAG) within population-based cohorts. DESIGN: Secondary analysis of 4 prospective population-based studies. PARTICIPANTS: We included four European-ancestry cohorts: the United States-based Nurses' Health Study, Nurses' Health Study 2, and the Health Professionals Follow-up Study and the Rotterdam Study (RS) in The Netherlands. The United States cohorts included female nurses and male health professionals ≤ 55 years of age. The RS included residents ≤ 45 years of age living in Rotterdam, The Netherlands. METHODS: Polygenic risk score weights were estimated by applying the lassosum method on imputed genotype and phenotype data from the UK Biobank. This resulted in 144 020 variants, single nucleotide polymorphism and insertions or deletions, with nonzero ßs that we used to calculate a PRS in the target populations. Using multivariable Cox proportional hazard models, we estimated the relationship between the standardized PRS and relative risk for POAG. Additionally, POAG prediction was tested by calculating these models' concordance (Harrell's C statistic). Finally, we assessed the association between PRS tertiles and glaucoma-related traits. MAIN OUTCOME MEASURES: The relative risk for POAG and Harrell's C statistic. RESULTS: Among 1046 patients and 38 809‬ control participants, the relative risk (95% confidence interval) for POAG for participants in the highest PRS quintile was 3.99 (3.08-5.18) times higher in the United States cohorts and 4.89 (2.93-8.17) times higher in the RS, compared with participants with median genetic risk (third quintile). Combining age, sex, intraocular pressure of more than 25 mmHg, and family history resulted in a meta-analyzed concordance of 0.75 (95% CI, 0.73-0.75). Adding the PRS to this model improved the concordance to 0.82 (95% CI, 0.80-0.84). In a meta-analysis of all cohorts, patients in the highest tertile showed a larger cup-to-disc ratio at diagnosis, by 0.10 (95% CI, 0.06 0.14), and a 2.07-fold increased risk of requiring glaucoma surgery (95% CI, 1.19-3.60). CONCLUSIONS: Incorporating a PRS into a POAG predictive model improves identification concordance from 0.75 up to 0.82, supporting its potential for guiding more cost-effective screening strategies. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

17.
Ophthalmology ; 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38964719

RESUMEN

PURPOSE: The Laser in Glaucoma and Ocular Hypertension Trial demonstrated the efficacy and safety of selective laser trabeculoplasty (SLT) compared with topical hypotensive medication as first-line therapy for ocular hypertension and open-angle glaucoma. This substudy explored the impact of pretreatment (baseline) intraocular pressure (IOP) on treatment response. DESIGN: Post hoc analysis of randomized control trial data. PARTICIPANTS: A total of 1146 eyes from 662 patients were included in this analysis: 559 eyes in the SLT group and 587 in the medication group. METHODS: Intraocular pressure reduction at 8 weeks after treatment with either SLT or prostaglandin analog (PGA) eye drops was assessed at different levels of baseline IOP, and the groups were compared. Differences in absolute and percentage IOP lowering between SLT and PGA groups were tested with a linear mixed-effects model. Differences in the probability of achieving ≥ 20% IOP lowering between SLT and PGA groups, at different levels of baseline IOP, were estimated using a logistic mixed-effects model. MAIN OUTCOME MEASURE: Intraocular pressure-lowering response to SLT versus PGA eye drops. RESULTS: Mean IOP was not significantly different between the groups at baseline or 8 weeks after treatment initiation. Both treatments showed greater IOP lowering at higher baseline IOP and less IOP lowering at lower baseline IOP. Selective laser trabeculoplasty tended to achieve more IOP lowering than PGA drops at higher baseline IOP. Prostaglandin analog drops performed better at lower baseline IOP, and the difference compared with SLT, in terms of percentage IOP reduction, was significant at baseline IOP of ≤ 17 mmHg. A significant difference was found in the relationship between baseline IOP and probability of ≥ 20% IOP lowering between the two treatments (P = 0.01), with SLT being more successful than PGA at baseline IOP of more than 22.5 mmHg. CONCLUSIONS: We confirm previous reports of greater IOP lowering with higher baseline IOP for both SLT and PGA drops. In treatment-naïve eyes, at higher baseline IOP, SLT was more successful at achieving ≥ 20% IOP lowering than PGA drops. At lower baseline IOP, a statistically greater percentage, but not absolute, IOP lowering was seen with PGA drops compared with SLT, although the clinical significance of this is uncertain. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

18.
Ophthalmology ; 131(7): 759-770, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38199528

RESUMEN

PURPOSE: To determine whether primary trabeculectomy or medical treatment produces better outcomes in terms of quality of life (QoL), clinical effectiveness, and safety in patients with advanced glaucoma. DESIGN: Multicenter randomized controlled trial. PARTICIPANTS: Between June 3, 2014, and May 31, 2017, 453 adults with newly diagnosed advanced open-angle glaucoma in at least 1 eye (Hodapp classification) were recruited from 27 secondary care glaucoma departments in the United Kingdom. Two hundred twenty-seven were allocated to trabeculectomy, and 226 were allocated medical management. METHODS: Participants were randomized on a 1:1 basis to have either mitomycin C-augmented trabeculectomy or escalating medical management with intraocular pressure (IOP)-reducing drops as the primary intervention and were followed up for 5 years. MAIN OUTCOME MEASURES: The primary outcome was vision-specific QoL measured with the 25-item Visual Function Questionnaire (VFQ-25) at 5 years. Secondary outcomes were general health status, glaucoma-related QoL, clinical effectiveness (IOP, visual field, and visual acuity), and safety. RESULTS: At 5 years, the mean ± standard deviation VFQ-25 scores in the trabeculectomy and medication arms were 83.3 ± 15.5 and 81.3 ± 17.5, respectively, and the mean difference was 1.01 (95% confidence interval [CI], -1.99 to 4.00; P = 0.51). The mean IOPs were 12.07 ± 5.18 mmHg and 14.76 ± 4.14 mmHg, respectively, and the mean difference was -2.56 (95% CI, -3.80 to -1.32; P < 0.001). Glaucoma severity measured with visual field mean deviation were -14.30 ± 7.14 dB and -16.74 ± 6.78 dB, respectively, with a mean difference of 1.87 (95% CI, 0.87-2.87 dB; P < 0.001). Safety events occurred in 115 (52.2%) of patients in the trabeculectomy arm and 124 (57.9%) of patients in the medication arm (relative risk, 0.92; 95% CI, 0.72-1.19; P = 0.54). Serious adverse events were rare. CONCLUSIONS: At 5 years, the Treatment of Advanced Glaucoma Study demonstrated that primary trabeculectomy surgery is more effective in lowering IOP and preventing disease progression than primary medical treatment in patients with advanced disease and has a similar safety profile. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Antihipertensivos , Glaucoma de Ángulo Abierto , Presión Intraocular , Mitomicina , Calidad de Vida , Trabeculectomía , Agudeza Visual , Campos Visuales , Humanos , Trabeculectomía/métodos , Masculino , Presión Intraocular/fisiología , Femenino , Agudeza Visual/fisiología , Anciano , Antihipertensivos/uso terapéutico , Campos Visuales/fisiología , Glaucoma de Ángulo Abierto/fisiopatología , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Persona de Mediana Edad , Mitomicina/administración & dosificación , Encuestas y Cuestionarios , Estudios de Seguimiento , Resultado del Tratamiento , Tonometría Ocular , Perfil de Impacto de Enfermedad , Soluciones Oftálmicas , Alquilantes/administración & dosificación , Anciano de 80 o más Años
19.
Exp Eye Res ; 241: 109855, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38453040

RESUMEN

Transgenic C57BL/6 mice expressing human myocilinY437 (Tg-MYOCY437H) are a well-established model for primary open-angle glaucoma (POAG). While the reduced trabecular meshwork (TM) cellularity due to severe endoplasmic reticulum (ER) stress has been characterized as the etiology of this model, there is a limited understanding of how glaucomatous phenotypes evolve over the lifespan of Tg-MyocY437H mice. In this study, we compiled the model's intraocular pressure (IOP) data recorded in our laboratory from 2017 to 2023 and selected representative eyes to measure the outflow facility (Cr), a critical parameter indicating the condition of the conventional TM pathway. We found that Tg-MYOCY437H mice aged 4-12 months exhibited significantly higher IOPs than age-matched C57BL/6 mice. Notably, a decline in IOP was observed in Tg-MYOCY437H mice at 17-24 months of age, a phenomenon not attributable to the gene dosage of mutant myocilin. Measurements of the Cr of Tg-MYOCY437H mice indicated that the age-related IOP reduction was not a result of ongoing TM damage. Instead, Hematoxylin and Eosin staining, immunohistochemistry analysis, and transmission electron microscopic examination revealed that this reduction might be induced by degenerations of the non-pigmented epithelium in the ciliary body of aged Tg-MYOCY437H mice. Overall, our findings provide a comprehensive profile of mutant myocilin-induced ocular changes over the Tg-MYOCY437H mouse lifespan and suggest a specific temporal window of elevated IOP that may be ideal for experimental purposes.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Animales , Humanos , Ratones , Proteínas del Ojo/genética , Proteínas del Ojo/metabolismo , Glaucoma/metabolismo , Glaucoma de Ángulo Abierto/genética , Glaucoma de Ángulo Abierto/metabolismo , Presión Intraocular , Longevidad , Ratones Endogámicos C57BL , Malla Trabecular/metabolismo
20.
Exp Eye Res ; 244: 109917, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38697276

RESUMEN

In glaucoma, scleral fibroblasts are exposed to IOP-associated mechanical strain and elevated TGFß levels. These stimuli, in turn, lead to scleral remodeling. Here, we examine the scleral fibroblast migratory and transcriptional response to these stimuli to better understand mechanisms of glaucomatous scleral remodeling. Human peripapillary scleral (PPS) fibroblasts were cultured on parallel grooves, treated with TGFß (2 ng/ml) in the presence of vehicle or TGFß signaling inhibitors, and exposed to uniaxial strain (1 Hz, 5%, 12-24 h). Axis of cellular orientation was determined at baseline, immediately following strain, and 24 h after strain cessation with 0° being completely aligned with grooves and 90° being perpendicular. Fibroblasts migration in-line and across grooves was assessed using a scratch assay. Transcriptional profiling of TGFß-treated fibroblasts with or without strain was performed by RT-qPCR and pERK, pSMAD2, and pSMAD3 levels were measured by immunoblot. Pre-strain alignment of TGFß-treated cells with grooves (6.2 ± 1.5°) was reduced after strain (21.7 ± 5.3°, p < 0.0001) and restored 24 h after strain cessation (9.5 ± 2.6°). ERK, FAK, and ALK5 inhibition prevented this reduction; however, ROCK, YAP, or SMAD3 inhibition did not. TGFß-induced myofibroblast markers were reduced by strain (αSMA, POSTN, ASPN, MLCK1). While TGFß-induced phosphorylation of ERK and SMAD2 was unaffected by cyclic strain, SMAD3 phosphorylation was reduced (p = 0.0004). Wound healing across grooves was enhanced by ROCK and SMAD3 inhibition but not ERK or ALK5 inhibition. These results provide insight into the mechanisms by which mechanical strain alters the cellular response to TGFß and the potential signaling pathways that underlie scleral remodeling.


Asunto(s)
Movimiento Celular , Fibroblastos , Esclerótica , Estrés Mecánico , Factor de Crecimiento Transformador beta , Humanos , Fibroblastos/metabolismo , Fibroblastos/efectos de los fármacos , Células Cultivadas , Factor de Crecimiento Transformador beta/farmacología , Factor de Crecimiento Transformador beta/metabolismo , Esclerótica/metabolismo , Transducción de Señal , Reacción en Cadena en Tiempo Real de la Polimerasa , Regulación de la Expresión Génica , Glaucoma/metabolismo , Glaucoma/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA