Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.267
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(3): 198-210, 2024 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-37874971

RESUMEN

BACKGROUND AND AIMS: Transcatheter pulmonary valve implantation (TPVI) is indicated to treat right-ventricular outflow tract (RVOT) dysfunction related to congenital heart disease (CHD). Outcomes of TPVI with the SAPIEN 3 valve that are insufficiently documented were investigated in the EUROPULMS3 registry of SAPIEN 3-TPVI. METHODS: Patient-related, procedural, and follow-up outcome data were retrospectively assessed in this observational cohort from 35 centres in 15 countries. RESULTS: Data for 840 consecutive patients treated in 2014-2021 at a median age of 29.2 (19.0-41.6) years were obtained. The most common diagnosis was conotruncal defect (70.5%), with a native or patched RVOT in 50.7% of all patients. Valve sizes were 20, 23, 26, and 29 mm in 0.4%, 25.5%, 32.1%, and 42.0% of patients, respectively. Valve implantation was successful in 98.5% [95% confidence interval (CI), 97.4%-99.2%] of patients. Median follow-up was 20.3 (7.1-38.4) months. Eight patients experienced infective endocarditis; 11 required pulmonary valve replacement, with a lower incidence for larger valves (P = .009), and four experienced pulmonary valve thrombosis, including one who died and three who recovered with anticoagulation. Cumulative incidences (95%CI) 1, 3, and 6 years after TPVI were as follows: infective endocarditis, 0.5% (0.0%-1.0%), 0.9% (0.2%-1.6%), and 3.8% (0.0%-8.4%); pulmonary valve replacement, 0.4% (0.0%-0.8%), 1.3% (0.2%-2.4%), and 8.0% (1.2%-14.8%); and pulmonary valve thrombosis, 0.4% (0.0%-0.9%), 0.7% (0.0%-1.3%), and 0.7% (0.0%-1.3%), respectively. CONCLUSIONS: Outcomes of SAPIEN 3 TPVI were favourable in patients with CHD, half of whom had native or patched RVOTs.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Cardiopatías Congénitas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Trombosis , Adulto , Humanos , Cateterismo Cardíaco/efectos adversos , Endocarditis/epidemiología , Endocarditis Bacteriana/complicaciones , Cardiopatías Congénitas/complicaciones , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Diseño de Prótesis , Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/epidemiología , Insuficiencia de la Válvula Pulmonar/cirugía , Sistema de Registros , Estudios Retrospectivos , Trombosis/etiología , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 103(4): 612-617, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38419395

RESUMEN

While newer self-expanding pulmonic valves were primarily designed for larger right ventricular outflow tracks, there are instances where even larger anatomies cannot accommodate these devices. In this report, we describe the successful implantation of two Harmony™ valves in bilateral branch pulmonary arteries after exhausting other options.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Pulmonar , Humanos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Arteria Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco
3.
Catheter Cardiovasc Interv ; 103(4): 660-669, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38419402

RESUMEN

Transcatheter pulmonary valve replacement (TPVR), also known as percutaneous pulmonary valve implantation, refers to a minimally invasive technique that replaces the pulmonary valve by delivering an artificial pulmonary prosthesis through a catheter into the diseased pulmonary valve under the guidance of X-ray and/or echocardiogram while the heart is still beating not arrested. In recent years, TPVR has achieved remarkable progress in device development, evidence-based medicine proof and clinical experience. To update the knowledge of TPVR in a timely fashion, and according to the latest research and further facilitate the standardized and healthy development of TPVR in Asia, we have updated this consensus statement. After systematical review of the relevant literature with an in-depth analysis of eight main issues, we finally established eight core viewpoints, including indication recommendation, device selection, perioperative evaluation, procedure precautions, and prevention and treatment of complications.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Válvula Pulmonar , Humanos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Resultado del Tratamiento , Asia , Catéteres
4.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38597297

RESUMEN

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Asunto(s)
Cateterismo Cardíaco , Análisis de Elementos Finitos , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Modelos Cardiovasculares , Modelación Específica para el Paciente , Diseño de Prótesis , Válvula Pulmonar , Humanos , Válvula Pulmonar/fisiopatología , Válvula Pulmonar/cirugía , Válvula Pulmonar/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Medición de Riesgo , Adolescente , Resultado del Tratamiento , Factores de Riesgo , Masculino , Niño , Estudios Retrospectivos , Femenino , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Adulto Joven , Valor Predictivo de las Pruebas , Hemodinámica , Stents , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Obstrucción del Flujo Ventricular Externo/fisiopatología , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Toma de Decisiones Clínicas , Adulto
5.
Catheter Cardiovasc Interv ; 104(2): 256-263, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38967206

RESUMEN

BACKGROUND: The Alterra adaptive prestent is a novel self-expanding device designed to provide a landing zone for the 29 mm SAPIEN 3 valve to treat pulmonary regurgitation in patients with a right ventricular outflow tract that is too large for a balloon expandable valve alone. The mechanism of fixation for the Alterra prestent is radial force from the self-expanding stent frame, combined with a unique set of flared "tines" that protrude from both ends of the stent. AIMS, METHODS, AND RESULTS: In this report, we describe 6 patients who underwent uncomplicated transcatheter pulmonary valve replacement with an Alterra adaptive prestent and SAPIEN 3 valve and had surveillance chest computed tomography (CT) scans performed 1 day to 21 months after implant. In each patient, the CT scan demonstrated extravascular extension of a portion of the Alterra prestent, without clinical sequelae, but with extension into the ascending aorta in 1 patient and contact with the ascending aorta, left pulmonary vein, or left atrial appendage in 3 others. CONCLUSIONS: Surveillance CT imaging shows that the Alterra prestent can perforate the pulmonary artery and/or right ventricle. Although no sequelae were seen in these patients, prestent perforation has the potential to be clinically important. Implanters should be aware of this finding and its potential implications. As experience with the Alterra prestent grows, it will be important to further define the risk factors, incidence, and implications of this phenomenon.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Valor Predictivo de las Pruebas , Diseño de Prótesis , Humanos , Masculino , Femenino , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Factores de Tiempo , Adulto , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Adulto Joven , Angiografía por Tomografía Computarizada , Adolescente , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/fisiopatología , Tomografía Computarizada por Rayos X
6.
Artículo en Inglés | MEDLINE | ID: mdl-39033329

RESUMEN

BACKGROUND: Patients with d-transposition of the great arteries (d-TGA) who have undergone an arterial switch operation (ASO) can develop right ventricular outflow tract (RVOT) dysfunction with pulmonary regurgitation (PR) or stenosis. In these patients, treatment may include transcatheter pulmonary valve replacement (TPVR). Coronary compression is a contraindication occurring in 5% of typical TPVR cases. After ASO, there are various anatomical considerations that can confound TPVR, including potential coronary artery compression. Our goal is to understand feasibility of TPVR in patients following ASO. METHODS: This was a retrospective multicenter cohort study of patients with RVOT dysfunction after ASO who underwent cardiac catheterization with intention to perform TPVR from 2008 to 2020. RESULTS: Across nine centers, 33 patients met inclusion criteria. TPVR was successful in 22 patients (66%), 19 receiving a Melody valve and 3 a SAPIEN valve. RVOT stenosis in isolation or with PR dictated need for TPVR in nearly all patients. One serious adverse event occurred with valve embolization. After TPVR, the RVOT peak gradient decreased from 43 to 9 mm Hg (p < 0.001); PR was trivial/none in all but one patient, in whom it was mild. Coronary compression prohibiting TPVR occurred in eight patients (24%) and two patients (6%) had severe aortic regurgitation from aortic root deformation precluding TPVR. Seven patients underwent RVOT reintervention with a median of 5.3 years post-TPVR. CONCLUSIONS: TPVR in patients with d-TGA after ASO is feasible, but in this cohort, coronary compression or aortic root distortion precluded TPVR in one-third of patients. The rate of RVOT reintervention after TPVR was higher in this cohort of ASO patients that in prior studies.

7.
Catheter Cardiovasc Interv ; 103(4): 587-596, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38341624

RESUMEN

BACKGROUND: Pulsta valve is increasingly used for percutaneous pulmonary valve implantation (PPVI) in patients with a large native right ventricular outflow tract (RVOT). This study aims to elucidate the outcomes of Pulsta valve implantation within the native RVOT and assess its adaptability to various native main pulmonary artery (PA) anatomies. METHODS: A multicenter retrospective study included 182 patients with moderate to severe pulmonary regurgitation in the native RVOT who underwent PPVI with Pulsta valves® between February 2016 and August 2023 at five Korean and Taiwanese tertiary referral centers. RESULTS: Pulsta valve implantation was successful in 179 out of 182 patients (98.4%) with an average age of 26.7 ± 11.0 years. The median follow-up duration was 29 months. Baseline assessments revealed enlarged right ventricle (RV) volume (mean indexed RV end-diastolic volume: 163.1 (interquartile range, IQR: 152.0-180.3 mL/m²), which significantly decreased to 123.6(IQR: 106.6-137.5 mL/m2  after 1 year. The main PA types were classified as pyramidal (3.8%), straight (38.5%), reverse pyramidal (13.2%), convex (26.4%), and concave (18.1%) shapes. Pulsta valve placement was adapted, with distal main PA for pyramidal shapes and proximal or mid-PA for reverse pyramidal shapes. Two patients experienced Pulsta valve embolization to RV, requiring surgical removal, and one patient encountered valve migration to the distal main PA, necessitating surgical fixation. CONCLUSIONS: Customized valve insertion sites are pivotal in self-expandable PPVI considering diverse native RVOT shape. The rather soft and compact structure of the Pulsta valve has characteristics to are adaptable to diverse native RVOT geometries.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Humanos , Adolescente , Adulto Joven , Adulto , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Ventrículos Cardíacos , Estudios Retrospectivos , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Resultado del Tratamiento , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Cateterismo Cardíaco
8.
Catheter Cardiovasc Interv ; 103(3): 455-463, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38204358

RESUMEN

This manuscript describes the feasibility and approach to the assessment and performance of transcatheter pulmonary valve replacement (tPVR) in patients with surgically-created "double-barrel" right ventricular outflow tracts (RVOT). Patients with tetralogy of Fallot may have coronary anomalies which prohibit the performance of traditional tetralogy of Fallot repair. In certain cases, this may necessitate the placement of a right ventricle to pulmonary artery conduit in addition to the native RVOT, which is left in situ, creating so-called "double-barrel" RVOTs. When these patients develop RVOT dysfunction later in life, they would typically be referred for reoperation due to concerns for risk of coronary compression associated with a transcatheter approach. However, whether a transcatheter approach with valve replacement in the native RVOT is feasible or safe is unknown. This was a retrospective review of patients with a surgically created "double-barrel" RVOTs who underwent cardiac catheterization for assessment of tPVR at Boston Children's Hospital. From July 2012 to July 2022, there were four patients with "double-barrel" RVOTs who underwent assessment for tPVR. The age at catheterization ranged between 22 and 39 years. In three out of four patients, coronary compression testing was negative. These three patients had successful tPVR in the native RVOT. At follow up, all three patients were free of greater than mild regurgitation by echocardiogram and had a maximum instantaneous gradient across the RVOT ranging between 20 and 33 mmHg. Performance of tPVR in patients with surgically created "double-barrel" RVOTs is feasible. The safety of this procedure depends crucially on coronary artery assessment at all stages.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Tetralogía de Fallot , Niño , Humanos , Adulto Joven , Adulto , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Ventrículos Cardíacos/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Estudios Retrospectivos , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía
9.
Catheter Cardiovasc Interv ; 103(4): 597-606, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38440908

RESUMEN

BACKGROUND: Current heart valve implants entail major disadvantages in the treatment for younger patients or those with congenital heart defects. AIM: Evaluation of novel transcatheter pulmonary valve implant made from autologous pericardium with natural crosslinking agent in an in vitro setup and in vivo animal model METHODS: Valves were tested in a pulse duplicator according to ISO-standard 5840. For in vivo studies computer tomography was performed to measure sheep's native pulmonary valve dimensions. Pericardium was harvested by thoracotomy, personalized implants were manufactured and deployed in pulmonary valve position of the same sheep. Every 3 months implant functionality was evaluated by intracardiac echocardiography, intracardiac pressure measurements and cardiac magnetic resonance imaging (cMRI). Implants were explanted for macroscopic and histological examination. RESULTS: In vitro experiments showed compliance with regulatory requirements in terms of valve opening and insufficiency. Five sheep successfully received an autologous valve implant. Two animals had to be euthanized due to trauma sustained in the stable. Long-term valve function was excellent in three out of four animals with median implant cMRI regurgitation fraction of 9% (n = 4) at 3 months, 8% (n = 3) at 6, 8% (n = 3) at 9, 12% (n = 3) at 13, 8% (n = 2) at 17% and 8% (n = 2) at 20.5 months after implantation. Despite good adherence to neighboring tissue and endothelization, histological assessment revealed some signs of degeneration. CONCLUSION: Transcatheter pulmonary valve implants showed promising function for up to 20.5 months encouraging research to further improve this approach.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Pulmonar , Humanos , Adulto , Animales , Ovinos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Válvulas Cardíacas/cirugía , Modelos Animales
10.
BMC Cardiovasc Disord ; 24(1): 301, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38872098

RESUMEN

BACKGROUND: Studies of transcatheter pulmonary valve replacement (TPVR) with the Melody valve have demonstrated good clinical and hemodynamic outcomes. Our study analyzes the midterm clinical and hemodynamic outcomes for patients who underwent Melody valve implantation in Southeast Asia. METHODS: Patients with circumferential conduits or bioprosthetic valves and experiencing post-operative right ventricular outflow tract (RVOT) dysfunction were recruited for Melody TPVR. RESULTS: Our cohort (n = 14) was evenly divided between pediatric and adult patients. The median age was 19 years (8-38 years), a male-to-female ratio of 6:1 with a median follow-up period of 48 months (16-79 months), and the smallest patient was an 8-year-old boy weighing 18 kg. All TPVR procedures were uneventful and successful with no immediate mortality or conduit rupture. The primary implant indication was combined stenosis and regurgitation. The average conduit diameter was 21 ± 2.3 mm. Concomitant pre-stenting was done in 71.4% of the patients without Melody valve stent fractures (MSFs). Implanted valve size included 22-mm (64.3%), 20-mm (14.3%), and 18-mm (21.4%). After TPVR, the mean gradient across the RVOT was significantly reduced from 41 mmHg (10-48 mmHg) to 16 mmHg (6-35 mmHg) at discharge, p < 0.01. Late follow-up infective endocarditis (IE) was diagnosed in 2 patients (14.3%). Overall freedom from IE was 86% at 79 months follow-up. Three patients (21.4%) developed progressive RVOT gradients. CONCLUSION: For patients in Southeast Asia with RVOT dysfunction, Melody TPVR outcomes are similar to those reported for patients in the US in terms of hemodynamic and clinical improvements. A pre-stenting strategy was adopted and no MSFs were observed. Post-implantation residual stenosis and progressive stenosis of the RVOT require long term monitoring and reintervention. Lastly, IE remained a concern despite vigorous prevention and peri-procedural bacterial endocarditis prophylaxis.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Válvula Pulmonar , Recuperación de la Función , Humanos , Masculino , Niño , Femenino , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Adolescente , Válvula Pulmonar/cirugía , Válvula Pulmonar/fisiopatología , Válvula Pulmonar/diagnóstico por imagen , Resultado del Tratamiento , Adulto Joven , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Factores de Tiempo , Adulto , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Bioprótesis , Estenosis de la Válvula Pulmonar/cirugía , Estenosis de la Válvula Pulmonar/fisiopatología , Estenosis de la Válvula Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , Factores de Riesgo , Asia Sudoriental
11.
BMC Cardiovasc Disord ; 24(1): 15, 2024 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-38172687

RESUMEN

BACKGROUND: Patients with repaired Tetralogy of Fallot (rTOF) often develop pulmonary regurgitation (PR) and right ventricle (RV) dysfunction, experiencing increased mortality and morbidity rates in adulthood. Pulmonary valve replacement (PVR) timing to address PR is controversial. Cardiac Magnetic Resonance (CMR) is the gold standard for morpho-functional evaluation of complex cardiopathies. This study aims to identify CMR parameters predictive of adverse outcomes to help defining the best therapeutic management of rTOF patients. METHODS: 130 rTOF patients who underwent CMR (2006-2019) were enrolled in this retrospective single-center study. CMR, clinical, ECG and exercise data were analyzed. Univariate and multivariate analyses identified clinical and CMR parameters predictive of adverse outcomes both individually (e.g., death, arrhythmias, heart failure (HF), pharmacological therapy, QRS ≥ 160ms) and as composite outcome. RESULTS: Univariate analysis confirmed RV volumes and RV ejection fraction corrected for PR as adverse outcome predictors and identified interesting correlations: pulmonary artery bifurcation geometry and abnormal interventricular septum (IVS) motion with arrhythmias (p < .001; p = .037), HF (p = .049; p = .005), composite outcome (p = .039; p = .009); right atrium (RA) dimensions with the composite outcome and the outcomes individually (p < .001). The best predictive models by multivariate analysis included sex (male), RV and RA dilation for QRS ≥ 160ms, time form repair to CMR, age at TOF repair and IVS fibrosis for pharmacological therapy. CONCLUSIONS: Besides RV volumes, new adverse prognostic factors could guide rTOF therapeutic management: pulmonary arteries morphology, abnormal IVS motion, RV dysfunction, RA dilation. Perspective multicentric evaluation is needed to specify their effective role.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Pulmonar , Tetralogía de Fallot , Disfunción Ventricular Derecha , Humanos , Masculino , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Estudios Retrospectivos , Imagen por Resonancia Magnética , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Espectroscopía de Resonancia Magnética , Función Ventricular Derecha , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/etiología
12.
Echocardiography ; 41(2): e15765, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38341768

RESUMEN

BACKGROUND: Mixed pulmonary disease with pulmonary regurgitation (PR) and stenosis (PS) in repaired tetralogy of Fallot (rTOF) can negatively impact ventricular health. Myocardial strain has been shown to be more sensitive at detecting occult ventricular dysfunction compared to right ventricular ejection fraction (RV EF). We hypothesize that rTOF patients with predominant PS will have lower RV global longitudinal strain (RV GLS) prior to and post-transcatheter pulmonary valve replacement (TPVR). METHODS: A retrospective cohort of rTOF patients who underwent cardiac magnetic resonance (CMR) and cardiac catheterization for right ventricular pressure (RVSP) measurement were analyzed at three time points: before valve implantation, at discharge and within 18 months post-TPVR. Patients were dichotomized into three groups based on RVSP: 0%-49%, 50%-74%, and >75%. RV GLS and left ventricular (LV) GLS by speckle tracking echocardiography (STE) were obtained from the apical 4-chamber using TomTec software (TOMTEC IS, Germany). RESULTS: Forty-eight patients were included. Every 14.3% increase in preimplantation RVSP above 28% was associated with an absolute magnitude 1% lower RV GLS (p = .001). Preimplantation RVSP when 75% or higher had 3.36% worse RV GLS than the lowest bin (p = .014). Overall, average RV strain magnitude was higher when preimplantation RVSP was less than 50% and had greater improvement over the three time points. Higher post implantation RVSP correlated with lower strain magnitude. CONCLUSION: Patients with significant PS (>50%) may benefit from earlier PVR and not depend solely on RV size and EF. Myocardial strain may be a more sensitive marker of function; however, larger, prospective studies are needed.


Asunto(s)
Insuficiencia de la Válvula Pulmonar , Estenosis de la Válvula Pulmonar , Válvula Pulmonar , Tetralogía de Fallot , Disfunción Ventricular Derecha , Humanos , Tetralogía de Fallot/complicaciones , Tetralogía de Fallot/cirugía , Tensión Longitudinal Global , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Volumen Sistólico , Estudios Retrospectivos , Función Ventricular Derecha , Estenosis de la Válvula Pulmonar/complicaciones , Estenosis de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/complicaciones , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/cirugía , Disfunción Ventricular Derecha/complicaciones , Disfunción Ventricular Derecha/diagnóstico por imagen
13.
Curr Cardiol Rep ; 26(9): 1031-1045, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39212775

RESUMEN

PURPOSE OF REVIEW: Present an updated overview of the prevention, diagnosis, and management of infective endocarditis in adult patients with congenital heart disease. RECENT FINDINGS: Care for patients with infective endocarditis is changing in the areas of specialized teams, diagnostics, and prevention. Endocarditis teams should be involved in the care of ACHD patients. The 2023 Duke Criteria for Infective Endocarditis and the 2023 European Society of Cardiology Guidelines have updated the criteria for diagnosis including new major criteria such as CT and positron emission computed tomography with 18F-fluorodeoxyglucose (FDG) scans. Immunological, PCR, and nucleic acid-based tests are now acceptable means to isolate infective organisms. Clindamycin is no longer recommended for antibiotic prophylaxis due to resistance and side effect profile. Special considerations for antibiotic prophylaxis and management must be made for specific congenital heart diseases in adulthood and pregnant ACHD patients. Infective endocarditis (IE), a potentially devastating clinical entity, is a feared threat to the health of adults with congenital heart disease (ACHD). IE needs a systematic approach for its prevention, early diagnosis and management with a multidisciplinary IE team's involvement. There have been changes in the diagnostics and management of IE, which is reflected in updated diagnostic criteria. Timely blood cultures and imaging continue to be the mainstay of diagnosis, however the timing of blood cultures, microbiological testing, and types of diagnostic imaging such as the positron emission computed tomography with 18F-fluorodeoxyglucose (FDG) scan are new. Bicuspid aortic valves, ventricular septal defects, transcatheter pulmonary valve replacements, and tetralogy of Fallot are diagnoses at higher risk for IE in the ACHD population. The following article will focus on the preventive strategies, in addition to novel diagnostic and therapeutic approaches of IE in ACHD patients.


Asunto(s)
Endocarditis , Cardiopatías Congénitas , Humanos , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/cirugía , Endocarditis/prevención & control , Endocarditis/diagnóstico , Endocarditis/complicaciones , Adulto , Profilaxis Antibiótica , Antibacterianos/uso terapéutico , Embarazo
14.
Pediatr Cardiol ; 45(2): 446-451, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37955720

RESUMEN

Absent pulmonary valve with tricuspid atresia or tricuspid stenosis (APV-TA/TS) is an extremely rare congenital heart defect associated with significant morbidity and mortality. Compared to Tetralogy of Fallot with Absent Pulmonary Valve Syndrome, branch pulmonary arteries are not typically significantly dilated. We present the case of a newborn male prenatally diagnosed APV-TA with intact ventricular septum (IVS) and nearly discontinuous branch pulmonary arteries, the surgical strategy employed, and the salient hemodynamic factors considered in the medical decision-making.


Asunto(s)
Cardiopatías Congénitas , Atresia Pulmonar , Válvula Pulmonar , Atresia Tricúspide , Tabique Interventricular , Recién Nacido , Masculino , Humanos , Atresia Tricúspide/diagnóstico por imagen , Atresia Tricúspide/cirugía , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/anomalías , Arteria Pulmonar/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Atresia Pulmonar/diagnóstico por imagen , Atresia Pulmonar/cirugía
15.
Pediatr Cardiol ; 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39043954

RESUMEN

Candidacy for transcatheter pulmonary valve replacement utilizing newer valve platforms is aided by industry-driven fit analyses. We report augmentation of this decision-making process by visualization of 4-dimensional cine imaging of patient-specific right ventricular outflow tract anatomy and a virtual valve model within a virtual reality platform.

16.
Pediatr Cardiol ; 45(4): 722-728, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38411710

RESUMEN

Pulmonary balloon valvuloplasty (PBV) is the treatment of choice for subjects with isolated pulmonary valve stenosis (IPS). The purpose of this study was to define fetal echocardiographic features associated with an inpatient PBV prior to newborn hospital discharge and characterize resource utilization of IPS fetuses among participating centers. Six center, retrospective case series of singleton fetuses identified between 2010 and 2020 with IPS. Third-trimester echocardiogram data was compared with postnatal data, included pulmonary valve Doppler velocities, pulmonary valve insufficiency and ductus arteriosus flow direction. Comparison between subjects who underwent inpatient PBV during their newborn hospital admission versus those infants referred for outpatient PBV after initial hospital discharge. We analyzed data by logistic regression, student t test and Chi-Square testing with a p value of ≤ 0.05 considered statistically significant. Forty-nine IPS fetuses were identified. Thirty-eight (78%) underwent inpatient PBV at 5 (range 1-58) days and 11 (22%) underwent outpatient PBV at 51.8 (11-174) days. Newborns requiring an inpatient PBV were more likely to have one or more characteristics on 3rd-trimester fetal echocardiogram: left to right or bidirectional ductus arteriosus flow (61% vs 0%), and/or a peak pulmonary valve velocity > 3.0 m/s (odds ratio 16.9, 95% confidence interval 3.02-94.17) with a sensitivity of 90.4% and specificity of 97.7%. Ductus arteriosus flow direction and pulmonary valve peak velocity in the 3rd trimester can successfully predict the need for newborn inpatient PBV. We speculate these findings may be useful in choosing delivery site for the pregnancy complicated by fetal IPS.


Asunto(s)
Valvuloplastia con Balón , Conducto Arterioso Permeable , Conducto Arterial , Estenosis de la Válvula Pulmonar , Lactante , Femenino , Embarazo , Humanos , Recién Nacido , Estudios Retrospectivos , Ecocardiografía , Tercer Trimestre del Embarazo , Estenosis de la Válvula Pulmonar/diagnóstico por imagen , Estenosis de la Válvula Pulmonar/cirugía , Ultrasonografía Prenatal
17.
Pediatr Cardiol ; 45(3): 570-579, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38296854

RESUMEN

Transcatheter pulmonary valve implantation (TPVI) is a surgical alternative for correcting dysfunctional right ventricular outflow tract in previously operated patients. MyVal transcatheter heart valve (THV) (Meril Life Sciences, India), a new transcatheter valve designed for aortic position has recently been reported to be implanted in pulmonary position. Myval transcatheter valve were implanted in patients with stenosed dysfunctional conduits, severe regurgitation from transannular patch or dysfunctional surgical pulmonary valves (Bioprosthesis). Procedural details and post-TPVI follow-up were analysed. Myval TPVI was used in Fifty three patients with median age of 15 years (IQR 12-19.5 years). Almost sixty percent of the patients were male, with a median weight of 50 kg (31-63 kg). Prestenting was used in more than 80 percent of patients (n = 45 patients), while 6 patients had a prior surgical valve implantation. After Myval TPVI implantation, the peak instantaneous gradient across the RVOT decreased from a median of 23.5 mmHg (IQR 10-53 mmHg) pre-procedure to 10 mmHg (IQR 5-16 mmHg) post-procedure. The median fluoroscopy time for the procedure was 35 min (IQR 23.5-44 min). The large sizes-mainly the 29-mm and 32 mm Myval (Navigator, Meril Life Sciences Pvt Ltd, India), were the most used size in 40% (n = 22) of the cases each. The median contrast volume used during the procedure was 247 mL (IQR 120-300 mL). Patients were followed for a median period of 360 days (IQR 164-525 days). At the last clinic follow-up, there was no tricuspid valve regurgitation. Moderate neo-pulmonary valve regurgitation was reported in three cases. Early experience of TPVI with MyVal is encouraging with procedural success in all patients and acceptable mid-term outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Humanos , Masculino , Niño , Adolescente , Adulto Joven , Adulto , Femenino , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Diseño de Prótesis , Cateterismo Cardíaco/métodos
18.
Pediatr Cardiol ; 45(3): 588-590, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38315220

RESUMEN

In this review, we provide a brief description of recently published articles addressing topics relevant to pediatric cardiologists. Our hope is to provide a summary of the latest articles published recently in other journals in our field. The articles address (1) A new index for prenatal diagnosis of total anomalous pulmonary venous return, (2) Outcomes of patients with Tetralogy of Fallot after pulmonary valve replacement (PVR), and (3) Short-term outcomes of the self expanding Harmony valve for transcatheter PVR.

19.
Cardiol Young ; : 1-3, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38528794

RESUMEN

We report the case of a 9-year-old male with severe congenital pulmonary valve stenosis referred to our centre for percutaneous valvotomy. On admission, trans-thoracic echocardiogram confirmed a unicuspid pulmonary valve with a peak/mean pulmonary valve gradient of 91/53 mmHg and a pulmonary annulus of 13.8 mm (-0.8 Z Score). It also showed an enlarged RV (RV/LV ratio 0,9). During cardiac catheterisation, an additional atrial septal defect (secundum) with significant left to right shunt (Qp/Qs > 2) was diagnosed, which was not amenable to percutaneous closure. The patient was referred for surgical repair.The atrial septal defect was closed by a direct running suture. The repair of the unicuspid valve consisted in bicuspidisation by a large commissurotomy to the left anterior wall of the pulmonary artery. The neo-commissure was created with two separate patches of autologous pericardium secured to the wall of the pulmonary root. The adjustment of the effective height of the pulmonary valve leaflets was done by trimming the patches and a triangular plication of the newly created posterior leaflet. Perioperative echocardiogram showed a peak gradient of 15 mm Hg and trivial pulmonary regurgitation. The total cross-clamp time was 92 min and the bypass time 123 min with a favourable evolution after the surgery.The particularity of the case is represented by the complexity of the bicuspidisation procedure. Using this technique, a tailored approach is needed for every patient.

20.
Cardiol Young ; 34(4): 865-869, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37921218

RESUMEN

BACKGROUND AND AIM: Pulmonary regurgitation is the most common complication in repaired tetralogy of Fallot patients. Severe chronic pulmonary regurgitation can be tolerated for decades, but if not treated, it can progress to symptomatic, irreversible right ventricular dilatation and dysfunction. We investigated clinical associations with pulmonary valve replacement among patients with significative pulmonary regurgitation and how interventional developments can change their management. METHODS: All adult patients with repaired tetralogy of Fallot who were followed at an adult CHD Clinic at a single centre from 1980 to 2022 were included on their first outpatient visit. Follow-up was estimated from the time of correction surgery until one of the following events occurred first: pulmonary valve replacement, death, loss to follow-up or conclusion of the study. RESULTS: We included 221 patients (116 males) with a median age of 19 (18-25). At a median age of 33 (10) years old, 114 (51%) patients presented significant pulmonary regurgitation. Among patients with significant pulmonary regurgitation, pulmonary valve replacement was associated with male gender, older age at surgical repair, and longer QRS duration in adulthood. Pulmonary valve replacement was performed in 50 patients, including four transcatheter pulmonary valve implantations, at a median age of 34 (14) years. CONCLUSION: Pulmonary regurgitation affects a large percentage of tetralogy of Fallot adult patients, requiring a long-term clinical and imaging follow-up. Sex, age at surgical repair and longer QRS are associated with the need of PVR among patients with significative pulmonary regurgitation. Clinical practice and current literature support TPVI as the future gold standard intervention.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Tetralogía de Fallot , Adulto , Humanos , Masculino , Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Tetralogía de Fallot/complicaciones , Tetralogía de Fallot/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Resultado del Tratamiento , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA