1.
Eur Radiol ; 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060493

RESUMEN

OBJECTIVES: The objective of this study is to prospectively assess the effectiveness of shoulder magnetic resonance (MR) arthrograms with positional manoeuvres in detecting posterior synovial folds. METHODS: Two radiologists independently assessed all axial MR arthrograms in internal rotation, neutral position, and external rotation for the presence of a posterior synovial fold. The diagnostic performances of the MR arthrograms were then compared, with results validated through arthroscopy. RESULTS: Arthroscopy was performed on 81 of the 150 patients included in the study. A posterior synovial fold was identified arthroscopically in eleven of these patients. Measurements of the posterior synovial fold obtained in external rotation and the neutral position of the arm showed a significant correlation with arthroscopic results (p < 0.05). For detecting the posterior synovial fold with arthroscopic correlation, the sensitivity and specificity values for observer 1 and observer 2 were 100-81.4% and 100-88.6%, respectively, for MR arthrograms in the neutral position; 100-52.9% and 100-62.9% for MR arthrograms in external rotation; and 100-95.7% and 81.8-98.6% for MR arthrograms in internal rotation. There was a fair agreement for MR arthrography in external rotation for detecting posterior synovial folds, while MR arthrograms in internal rotation and neutral position showed near-perfect and significant interobserver agreement. CONCLUSION: The rotational positions of the humeral neck during MR arthrographic examination can influence the diagnostic specificity and sensitivity of axial MR arthrograms in detecting the posterior synovial fold. CLINICAL RELEVANCE STATEMENT: The posterior synovial fold can mimic a posterior labral detachment. Therefore, its correct identification is crucial in order to avoid unnecessary surgical procedures. KEY POINTS: Movement of the shoulder may introduce variability in MR arthrography appearance. Rotation of the humeral neck during MR arthrography can affect diagnoses in posterior synovial fold detection. Given that posterior synovial folds can imitate posterior labral detachment, their correct identification is crucial to avoid unnecessary surgical procedures.

2.
Dement Geriatr Cogn Disord ; : 1-8, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39197430

RESUMEN

INTRODUCTION: Dementia is caused by various diseases, including Alzheimer's disease dementia (ADD) and dementia with Lewy bodies (DLB). We often encounter patients with dementia who have limited shoulder joint range of motion (ROM), especially those with behavioral and psychological symptoms of dementia (BPSD). But the relationship between the diseases of dementia and restricted shoulder joint ROM is currently unclear. METHODS: We examined cognitive function and shoulder joint ROM in 234 new outpatients at 7 memory clinics in Japan. We assessed cognitive function using the Mini-Mental State Examination (MMSE) and Revised Hasegawa Dementia Scale (HDS-R) and BPSD using the Neuropsychiatric Inventory Questionnaire (NPI-Q). Patients were categorized by dementia diagnosis (ADD, DLB, other dementia, and control). Right, left, and total shoulder joint ROM was assessed using validated the Japanese Orthopaedic Association (JOA) score. RESULTS: We found significant associations of lower right, left, and total shoulder joint ROM scores with male sex, advanced age, higher NPI-Q score, lower HDS-R, and MMSE scores. Little difference was found between right and left shoulder joint ROM scores. Restricted shoulder joint ROM was related to serial 7, verbal frequency domain scores on the HDS-R and repeat score on the MMSE. It was also related to the hallucinations, irritability/lability and nighttime disturbances scores on the NPI-Q. Furthermore, the dementia groups, especially the DLB group, showed worse shoulder joint ROM than the control group. CONCLUSIONS: Dementia was significantly related to restricted shoulder joint ROM. Maintaining communication and social interaction may help maintain shoulder joint ROM.

3.
BMC Womens Health ; 24(1): 160, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38443932

RESUMEN

BACKGROUND: Approximately 30% of post-operative breast cancer patients develop shoulder joint movement disorders affecting routine upper limb movement. This study discusses the impact of a neuromuscular joint facilitation (NJF) method on the physical function of breast cancer patients experiencing shoulder dysfunction during chemotherapy after radical surgery. METHODS: This study included 162 female patients who have unilateral breast cancer in a cancer hospital in China. They developed shoulder joint mobility disorders during chemotherapy within 1-3 months postoperatively. These patients were divided into three groups: NJF, conventional rehabilitation (conventional group), and control groups. The clinical examination included the maximum passive and active range of motion (ROM) of the shoulder (flexion, extension, abduction, adduction, and external and internal rotation). Other evaluations included a pain score using a visual analog scale (VAS), grip strength, and supraspinatus muscle thickness. All tests were evaluated pre-and post-intervention. RESULTS: The NJF group showed a significant increase in all shoulder ROM angles post-intervention. In the conventional group, all other ROM values increased significantly, except passive external rotation ROM. In the control group, all other ROM values increased significantly, except passive and active external rotation ROM. All three groups had decreased VAS scores, increased grip strength, and supraspinatus muscle thickness post-intervention during active abduction. In the control group, the supraspinatus contraction rate decreased significantly at 60° and 90° abduction post-intervention compared to that at pre-intervention. CONCLUSION: This study revealed that NJF during chemotherapy had positive clinical intervention effects, improving shoulder joint mobility disorders, pain, grip strength, and external rotation following radical breast cancer surgery. CLINICAL TRIAL REGISTRATION: Chinese Clinical Trial Registry; https://www.chictr.org.cn/ (ChiCTR2300073170), registered (03/07/2023).


Asunto(s)
Neoplasias de la Mama , Entrenamiento de Fuerza , Humanos , Femenino , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/cirugía , Mama , Pueblo Asiatico , Dolor
4.
Artículo en Inglés | MEDLINE | ID: mdl-38897400

RESUMEN

OBJECTIVE: To systematically review the literature on the efficacy of addressing glenohumeral internal rotation deficit (GIRD) and risk of upper-extremity injury in overhead athletes. DATA SOURCES: A search was conducted for relevant studies published in PubMed, Medline, CINAHL, Cochrane, Embase, Ovid, Google Scholar, and Web of Science. STUDY SELECTION: The review focused on randomized controlled trials (RCTSs) and quasi-experiments conducted in English language that assessed the effectiveness of GIRD and the risk of upper-extremity injury in athletes performing overhead movements. The review included 7 RCTs and 2 quasi-experiments out of 5403, which involved a total of 360 participants. DATA EXTRACTION: Two reviewers independently screened the articles, assessed methodological quality, and extracted data for analysis. The review was conducted and reported according to the Preferred Reporting Items for Systematic Reviews. All studies were assessed in duplicate for risk of bias using the Physiotherapy Evidence Database Scale for RCTs. DATA SYNTHESIS: The efficacy of different types of techniques was evaluated, including joint mobilization, sleeper stretch, cross-body stretch, myofascial release, kinesio taping, and rigid taping. These techniques showed improvement in pain score and range of motion. Furthermore, self-myofascial release tends to improve internal rotation; sleeper stretch and cross-body stretch tend to improve internal rotation with 40 percent decline in pain. However, kinesio taping and rigid taping showed positive results for internal rotation. Acute results determined that the metabolic equivalent (MET) group had significantly more horizontal adduction range of motion posttreatment compared with the control group (P=.04). No significant differences existed between MET and joint mobilizations or between joint mobilizations and the control group for horizontal adduction (P>.16). No significant between-group differences existed acutely for internal rotation (P>.28). There were no significant between-group differences for either horizontal adduction or internal rotation at the 15-minute posttests (P>.70). CONCLUSIONS: The study evaluated the efficacy of various techniques in improving pain score and range of motion in individuals with GIRD. Joint mobilization, sleeper stretch, cross-body stretch, myofascial release, kinesio taping, and rigid taping all showed improvements in pain score and range of motion. However, no significant between-group differences were found for horizontal adduction or internal rotation at the 15-minute posttests. These findings suggest that a combination of these techniques may be effective in treating individuals with GIRD.

5.
J Biomech Eng ; 146(8)2024 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-38470378

RESUMEN

Muscle torque generators (MTGs) have been developed as an alternative to muscle-force models, reducing the muscle-force model complexity to a single torque at the joint. Current MTGs can only be applied to single Degree-of-freedom (DoF) joints, leading to complications in modeling joints with multiple-DoFs such as the shoulder. This study aimed to develop an MTG model that accounts for the coupling between 2-DoF at the shoulder joint: shoulder plane of elevation (horizontal abduction/adduction) and shoulder elevation (flexion/extension). Three different 2-DoF MTG equations were developed to model the coupling between these two movements. Net joint torques at the shoulder were determined for 20 participants (10 females and 10 males) in isometric, isokinetic, and passive tests. Curve and surface polynomial fitting were used to find the best general fit for the experimental data in terms of the different degrees of coupling. The models were validated against experimental isokinetic torque data. It was determined that implicit coupling that used interpolation between single-DoF MTGs resulted in the lowest root-mean-square percent error of 8.5%. The work demonstrated that general MTG models can predict torque results that are dependent on multiple-DoFs of the shoulder.


Asunto(s)
Articulación del Hombro , Masculino , Femenino , Humanos , Articulación del Hombro/fisiología , Torque , Hombro , Músculos , Movimiento/fisiología , Fenómenos Biomecánicos
6.
BMC Musculoskelet Disord ; 25(1): 618, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39095725

RESUMEN

INTRODUCTION: Upper cross syndrome is one of the most common disorders of the upper part of body, often associated with abnormalities of forward head, forward shoulders, elevated and protracted of scapula, and increased thoracic kyphosis. Conducting research on upper cross syndrome, especially in girls, is of highly significant, considering this issue and lack of examination of complications and consequences of this syndrome; therefore, this study aims to compare the balance and proprioception of the shoulder joint in girls with and without upper cross syndrome.Method The statistical population included two groups of 10-12-year-old female students, i.e., healthy and those with upper cross syndrome in the city of Khalkhal in Iran in 2022-2023. A total of 60 girl children were included in this study. The subjects were screened using a checker board and after quantitative evaluations of posture, they were assigned into two groups: healthy group (No. 30) and the one suffering from upper cross syndrome (No. 30). Forward head and forward shoulder angle were assessed using photography and kinovea software, kyphosis angle using Goniometer-pro app, static and dynamic balance using BESS and Y tests, also proprioception at angles of 45- and 80-degrees external rotation of the shoulder joint through photography and kinovea software. Data were analyzed through independent t-test in SPSS software version 26 at the significance level of 0.05.Results Healthy girls were in a better position in all variables of static balance (1.14 95% CI: [0.96, 1.70], p = 0.001), dynamic balance (0.81, 95% CI: [0.73,1.24], p = 0.001), proprioception of external rotation of shoulder joint at 45- (0.78, 95% CI: [0.64, 1.14], p = 0.001) and 80-degrees (0.89, 95% CI: [0.59, 1.34], p = 0.001) angles than those with upper cross syndrome.Conclusion It can be concluded that upper cross syndrome causes a decrease in balance and proprioception of the shoulder joint in female students; therefore, along with correcting the abnormalities, special attention should be paid to strengthening and improving these components. It is recommended for rehabilitation professionals to apply exercise training programs to improve the balance and proprioception and correct of the upper cross syndrome: that the strengthening of these components prevents musculoskeletal disorders.Implications for clinical practice• It is recommended for rehabilitation professionals to apply exercise training programs to improve the balance and proprioception of individual with upper cross syndrome.• It is recommended for rehabilitation professionals to apply exercise training programs to correct of the upper cross syndrome in order to prevents musculoskeletal disorders.


Asunto(s)
Equilibrio Postural , Propiocepción , Articulación del Hombro , Humanos , Femenino , Propiocepción/fisiología , Niño , Articulación del Hombro/fisiopatología , Equilibrio Postural/fisiología , Cifosis/fisiopatología , Irán , Escápula/fisiopatología , Rango del Movimiento Articular/fisiología
7.
BMC Musculoskelet Disord ; 25(1): 535, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38997654

RESUMEN

BACKGROUND: The study aimed to determine the grade of retraction and atrophy according to the time elapsed in traumatic isolated full-thickness supraspinatus (SS) tears in young patients. METHODS: One thousand twenty-six patients, who underwent arthroscopic shoulder surgery, were retrospectively reviewed. Pre-operative magnetic resonance imaging (MRI) of 69 patients aged 18 to 40 years with isolated traumatic full-thickness SS lesions remaining after exclusion criteria were evaluated for tendon retraction and atrophy grades. SS retraction was determined from a T2-weighted oblique coronal MRI slice, and the atrophy grade was determined from the T1-weighted oblique sagittal MRI slice. The patients were divided into four groups 0-1 month, 1-3 months, 3-6 months, and 6-12 months according to the time between trauma and MRI. The relationship of tendon retraction and muscle atrophy with elapsed time was evaluated, in addition, comparisons between groups were made. RESULTS: Thirty-one (45%) of the patients were female and their mean age was 30 ± 7.3 (18-40) years. The mean age of men was 30.5 ± 6.9 (18-39) years (p = 0.880). The time between rupture and MRI was moderately correlated with retraction and strongly correlated with atrophy grades (r = 0.599, 0.751, respectively). It was observed that there was a statistically significant difference between the 1st (0-1 month) and 2nd (1-3 months) groups (p = 0.003, 0.001, respectively), and between the 2nd and 3rd (3-6 months) groups (p = 0.032, 0.002, respectively), but there was no significant difference between the 3rd and 4th (6-12 months) groups (p = 0.118, 0.057, respectively). In addition, there was a moderate correlation between tendon retraction and atrophy grades (r = 0.668). Power (1- b) in post hoc analysis was calculated as 0.826. CONCLUSIONS: The current study, supported by arthroscopy, showed that there is a moderate and strong positive correlation between the time elapsed after trauma and the level of retraction and degree of atrophy in traumatic full-thickness SS tears, and demonstrated the importance of early surgical intervention in young patients.


Asunto(s)
Imagen por Resonancia Magnética , Atrofia Muscular , Lesiones del Manguito de los Rotadores , Humanos , Femenino , Masculino , Adulto , Adolescente , Adulto Joven , Estudios Retrospectivos , Lesiones del Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/patología , Atrofia Muscular/patología , Atrofia Muscular/diagnóstico por imagen , Atrofia Muscular/etiología , Factores de Tiempo , Manguito de los Rotadores/patología , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/cirugía , Artroscopía/métodos , Traumatismos de los Tendones/diagnóstico por imagen , Traumatismos de los Tendones/patología , Traumatismos de los Tendones/cirugía
8.
Artículo en Inglés | MEDLINE | ID: mdl-39109503

RESUMEN

PURPOSE: The aim of this study was to analyse clinical, functional and shoulder kinematics results using subacromial balloon spacer in nonreparable massive rotator cuff tears. Subacromial balloon spacer was hypothesised to improve shoulder kinematics and increases clinical and functional outcomes scores in nonreparable massive rotator cuff tears. METHODS: This is a prospective study in massive rotator cuff tears. From October 2021 to October 2022, a total of 127 shoulders suffering massive rotator cuff tears were initially evaluated. All patients were evaluated preoperatively, at 6 and 12 months. Patients' patient-reported outcome measures (PROM) subjective values using visual analogue scale (VAS) and the Spanish Western Ontario Rotator Cuff Index (WORC) version were analysed. We also evaluated objective outcomes: constant score, range of movement and kinematic shoulder analysis (isokinetic test to evaluate internal and external rotation forces). Statistical analysis was conducted using SPSS software; continuous variables were presented as means and standard deviations (SDs). RESULTS: Seventeen nonrepairable massive rotator cuff tears were finally included. Three patients required reverse shoulder arthroplasty before 6 months postoperative. After 1-year follow-up, objective and subjective (PROM) outcome scores and isokinetic measurements improved in 13 patients. Preoperative VAS improved from 6.5 ± 2.1 to 2 ± 1.9 points on average at 1-year follow-up and WORC index from 1603 ± 217.3 to 699 ± 361.6. Constant score from 42.1 ± 13.1 on average and at 1-year follow-up increased to 60.8 ± 14.7. Range of movement also improved in elevation 122.2 ± 39.3 to 166.9 ± 25.8, abduction 120.3 ± 38.6 to 134.6 ± 21.1, external rotation 30.3 ± 19.7 to 86.1 ± 13.8 and internal rotation L4-T12 on average at 1-year follow-up. Isokinetic evaluation showed functional improvement 1 year after implantation. Both internal and external rotation improved compared with their healthy shoulder. External rotation improved from 30.3° ± 19.7° preoperatively to 86.1° ± 13.8° (43.7% in the isokinetic study) and internal rotation from L4 preoperatively to L1 (49.8% in isokinetic study) on average. CONCLUSION: Among the different alternatives for irreparable rotator cuff injuries surgical treatment, subacromial balloon spacer is an effective alternative in selected patients, both in terms of clinical-functional improvement and short-term isokinetic results. LEVEL OF EVIDENCE: Level II.

9.
BMC Med Educ ; 24(1): 1103, 2024 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-39375643

RESUMEN

BACKGROUND: The integration of Virtual Reality (VR) with Case-Based Learning (CBL) has the potential to revolutionise undergraduate medical education, particularly in complex subjects such as the anatomy and rehabilitation of the shoulder joint. This study aimed to explore the effectiveness of this innovative approach in enhancing learning outcomes and knowledge retention. METHODS: This study employed a parallel-group, assessor-blinded randomised controlled trial (RCT) design. A comprehensive five-week educational programme was developed, combining traditional lecture-based learning with VR-enhanced CBL. The study involved 82 undergraduate students from China Medical University, who were divided into groups receiving different combinations of VR and CBL. Student performance was evaluated through tests and questionnaires. RESULTS: In the anatomy-related courses, the integration of VR technology with CBL yielded significantly higher results (87.71 ± 5.60) compared to traditional methods (82.59 ± 6.64), with a statistically significant difference (P < 0.05). This provides compelling evidence of VR's potential to enhance student engagement and knowledge retention. In the context of physiotherapy-related courses, however, while the test scores of the VR-combined CBL group (81.85 ± 5.99) were marginally higher than those of the traditional CBL group (79.02 ± 7.57), this difference was not statistically significant (P > 0.05). CONCLUSION: The present study provides preliminary evidence for the benefits of incorporating VR into medical education, particularly in anatomy. While the results are promising, further research is needed to explore the optimal integration of VR and CBL in rehabilitation studies and to assess their long-term impact on student learning and clinical performance. TRIAL REGISTRATION: The study was registered with Chinese Clinical Trials Registry (Registration Number: ChiCTR2400089295) on 05/09/2024.


Asunto(s)
Educación de Pregrado en Medicina , Articulación del Hombro , Realidad Virtual , Humanos , Educación de Pregrado en Medicina/métodos , Masculino , Femenino , Estudiantes de Medicina , Adulto Joven , Aprendizaje Basado en Problemas/métodos , China , Evaluación Educacional , Anatomía/educación , Curriculum
10.
Sensors (Basel) ; 24(11)2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38894058

RESUMEN

The integration of artificial intelligence (AI) models in the classification of electromyographic (EMG) signals represents a significant advancement in the design of control systems for prostheses. This study explores the development of a portable system that classifies the electrical activity of three shoulder muscles in real time for actuator control, marking a milestone in the autonomy of prosthetic devices. Utilizing low-power microcontrollers, the system ensures continuous EMG signal recording, enhancing user mobility. Focusing on a case study-a 42-year-old man with left shoulder disarticulation-EMG activity was recorded over two days using a specifically designed electronic board. Data processing was performed using the Edge Impulse platform, renowned for its effectiveness in implementing AI on edge devices. The first day was dedicated to a training session with 150 repetitions spread across 30 trials and three different movements. Based on these data, the second day tested the AI model's ability to classify EMG signals in new movement executions in real time. The results demonstrate the potential of portable AI-based systems for prosthetic control, offering accurate and swift EMG signal classification that enhances prosthetic user functionality and experience. This study not only underscores the feasibility of real-time EMG signal classification but also paves the way for future research on practical applications and improvements in the quality of life for prosthetic users.


Asunto(s)
Electromiografía , Aprendizaje Automático , Hombro , Humanos , Electromiografía/métodos , Adulto , Masculino , Hombro/fisiología , Músculo Esquelético/fisiología , Procesamiento de Señales Asistido por Computador
11.
Arch Orthop Trauma Surg ; 144(5): 2093-2099, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38653836

RESUMEN

OBJECTIVE: The objective of this study was to evaluate clinical and radiological outcomes of a short stem reverse shoulder prosthesis with metaphyseal fixation specifically in older patients. METHODS: All patients, older than 70 years, submitted to a Reverse Shoulder Arthroplasty (RSA) using a cementless onlay short stem (Aequalis Ascend™ Flex Convertible Shoulder System (Stryker®)) from January 2017 to December 2021, with a minimum follow-up of 2 years, were included. Postoperative radiographs were assessed for stem loosening, subsidence, and varus-valgus tilt. Range of motion, visual analogue scale for pain, constant score, complication rate and revision rate were also analysed. RESULTS: A total of 34 patients with a mean age of 75 years (range 71-83 years) were submitted to a cementless onlay short stem RSA with a Bone Increased Off-Set (BIO-RSA) construct. The mean follow-up period was 61 months (range 54-87). Significant improvements (p < 0.001) were observed for the constant score and range of motion from the preoperative state to final follow-up. One case exhibited a significant varus deviation (> 5˚) during the follow-up period. No case of stem loosening was identified. There was only one case of complication because of post-traumatic dislocation, but the stem didn't need revision. CONCLUSION: Short stem RSA, even in patients older than 70 years, can yield a stable fixation with a good clinical and radiological outcome at short-medium term follow-up. LEVEL OF EVIDENCE: Level III; Retrospective Study.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Diseño de Prótesis , Prótesis de Hombro , Humanos , Anciano , Artroplastía de Reemplazo de Hombro/métodos , Anciano de 80 o más Años , Femenino , Masculino , Rango del Movimiento Articular , Estudios Retrospectivos , Radiografía , Resultado del Tratamiento , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen
12.
Arch Orthop Trauma Surg ; 144(3): 1149-1159, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38231206

RESUMEN

INTRODUCTION: Despite being the most used exam today, few studies have evaluated the accuracy of findings on non-contrast magnetic resonance imaging (MRI). The primary objective of the study was to evaluate the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of non-contrast MRI findings in frozen shoulder, isolated and in combination. The secondary objectives were to define the interobserver and intraobserver agreement of the assessments and the odds ratio for frozen shoulder because of the various findings of MRI. METHODS: A retrospective diagnostic accuracy study comparing non-contrast MRI findings between the frozen shoulder group and the control group. Sensitivity, specificity, positive and negative predictive value, accuracy, odds ratio, interobserver and intraobserver agreement were calculated for each finding and their possible associations. RESULTS: The hyperintensity on capsule in the axillary recess presented 84% sensitivity, 94% specificity, and 89% accuracy. The obliteration of the subcoracoid fat triangle in the rotator interval had sensitivity 34%, specificity 82% and accuracy 58%. For coracohumeral ligament thickness ≥ 2 mm had specificity 66%, 48% specificity and 57% accuracy. Capsule thickness in the axillary recess ≥ 4 mm resulted in 54% sensitivity, 82% specificity, and 68% accuracy. Regarding interobserver agreement, only the posteroinferior and posterosuperior quadrants showed moderate results, and all the others showed strong reliability. The odds ratio for hyperintensity in the axillary recess was 82.3 for frozen shoulder. The association of these findings increased specificity (95%). CONCLUSION: The accuracy of non-contrast magnetic resonance imaging is high for diagnosing frozen shoulder, especially when evaluating the hyperintensity of the axillary recess. The exam has high reliability and reproducibility. The presence of an association of signs increases the specificity of the test. LEVEL OF EVIDENCE: Level III, study of diagnostic test.


Asunto(s)
Bursitis , Articulación del Hombro , Humanos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Articulación del Hombro/patología , Imagen por Resonancia Magnética/métodos , Bursitis/diagnóstico por imagen , Sensibilidad y Especificidad
13.
Prague Med Rep ; 125(2): 158-162, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38761049

RESUMEN

The coracoclavicular joint is a diarthrodial synovial joint that is eventually located between the upper surface of the horizontal part of the coracoid process and the conoid tubercle of the clavicle, and is considered an unusual anatomical alteration. The coracoclavicular joint has a low prevalence and can be diagnosed by imaging tests - radiography and computed tomography. Treatment can be performed both conservatively and surgically. We report a case of an 81-year-old female patient presenting of pain in her left shoulder due to coracoclavicular joint arthrosis. A radiograph of the left shoulder was performed, which detected a deformity in the lower portion of the middle third of the clavicle and the upper portion of the coracoid process, corresponding to the coracoclavicular joint, a finding confirmed by computed tomography. The patient was treated conservatively with analgesics (Dipyrone) and anti-inflammatories (Ibuprofen) with improvement in symptoms.


Asunto(s)
Dolor de Hombro , Humanos , Femenino , Anciano de 80 o más Años , Dolor de Hombro/etiología , Dolor de Hombro/diagnóstico , Apófisis Coracoides , Tomografía Computarizada por Rayos X
14.
Medicina (Kaunas) ; 60(8)2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39202613

RESUMEN

Background and Objectives: This study aimed to evaluate the relationship between SLAP lesions and the shoulder joint capsule thickness via MR arthrography. Understanding the relationship between SLAP lesions and the joint capsule thickness is important because an increased capsule thickness may indicate chronic inflammation and contribute to persistent pain and dysfunction. These findings have significant clinical implications for the diagnosis, management, and treatment strategies of shoulder joint pathologies. Materials and Methods: We retrospectively analyzed the MR arthrography results of 78 patients who underwent shoulder imaging at Düzce University Medical Faculty between October 2021 and November 2024. The study included patients diagnosed with SLAP lesions and compared them with a control group without such pathology. Data on joint capsule thickness at the level of the axillary recess, SLAP lesion type, cuff pathology, and demographic information were collected and analyzed. Results: The study included 32 patients with SLAP lesions and 46 control subjects. The mean age of the patients was 44.75 ± 14.18 years, whereas the control group had a mean age of 38.76 ± 13 years. The patient group presented a significantly greater mean anterior capsule thickness (3.13 ± 1.28 mm vs. 1.72 ± 0.7 mm, p = 0.0001), posterior capsule thickness (3.35 ± 1.32 mm vs. 1.95 ± 1.06 mm, p = 0.0001), and maximum capsule thickness (3.6 ± 1.32 mm vs. 2.06 ± 1.01 mm, p = 0.0001) in the axillary recess. SLAP type 2 lesions were the most common type (43.76%) in the patient group. Conclusions: This study revealed a significant association between SLAP lesions and an increased shoulder joint capsule thickness. These findings suggest that MR arthrography is an effective tool for assessing the joint capsule changes associated with labral tears, contributing to the better diagnosis and management of shoulder joint pathologies in clinical practice.


Asunto(s)
Cápsula Articular , Imagen por Resonancia Magnética , Articulación del Hombro , Humanos , Femenino , Masculino , Adulto , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiopatología , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Cápsula Articular/diagnóstico por imagen , Cápsula Articular/patología , Estudios Retrospectivos , Artrografía/métodos , Estudios de Casos y Controles , Lesiones del Hombro/diagnóstico por imagen
15.
J Sport Rehabil ; 33(5): 376-380, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38663843

RESUMEN

CLINICAL SCENARIO: The fascial relationship between scapular muscles and abdominal muscles has been documented from previous studies. However, it is not yet clear whether voluntary abdominal contraction has a beneficial effect on scapular muscle activity during shoulder exercises. CLINICAL QUESTION: Do scapulothoracic muscle activation levels increase if shoulder exercises are performed with voluntary abdominal activation? Summary of Key Finding: After the literature review, 4 cross-sectional studies met the inclusion criteria and were included in this critically appraised topic. CLINICAL BOTTOM LINE: There is moderate evidence to support dynamic shoulder exercises with voluntary abdominal contraction can increase trapezius and serratus anterior muscle activation level in asymptomatic shoulders. Strength and Recommendation: Findings from 4 cross-sectional trials indicate that there is moderate evidence supporting that dynamic shoulder exercises performed with voluntary abdominal contraction can increase scapular muscle activity.


Asunto(s)
Músculos Abdominales , Contracción Muscular , Escápula , Humanos , Músculos Abdominales/fisiología , Escápula/fisiología , Contracción Muscular/fisiología , Hombro/fisiología , Músculo Esquelético/fisiología , Ejercicio Físico/fisiología
16.
Eur Radiol ; 33(3): 1513-1525, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36166084

RESUMEN

OBJECTIVES: To compare the image quality and diagnostic performance of conventional motion-corrected periodically rotated overlapping parallel line with enhanced reconstruction (PROPELLER) MRI sequences with post-processed PROPELLER MRI sequences using deep learning-based (DL) reconstructions. METHODS: In this prospective study of 30 patients, conventional (19 min 18 s) and accelerated MRI sequences (7 min 16 s) using the PROPELLER technique were acquired. Accelerated sequences were post-processed using DL. The image quality and diagnostic confidence were qualitatively assessed by 2 readers using a 5-point Likert scale. Analysis of the pathological findings of cartilage, rotator cuff tendons and muscles, glenoid labrum and subacromial bursa was performed. Inter-reader agreement was calculated using Cohen's kappa statistic. Quantitative evaluation of image quality was measured using the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). RESULTS: Mean image quality and diagnostic confidence in evaluation of all shoulder structures were higher in DL sequences (p value = 0.01). Inter-reader agreement ranged between kappa values of 0.155 (assessment of the bursa) and 0.947 (assessment of the rotator cuff muscles). In 17 cases, thickening of the subacromial bursa of more than 2 mm was only visible in DL sequences. The pathologies of the other structures could be properly evaluated by conventional and DL sequences. Mean SNR (p value = 0.01) and CNR (p value = 0.02) were significantly higher for DL sequences. CONCLUSIONS: The accelerated PROPELLER sequences with DL post-processing showed superior image quality and higher diagnostic confidence compared to the conventional PROPELLER sequences. Subacromial bursa can be thoroughly assessed in DL sequences, while the other structures of the shoulder joint can be assessed in conventional and DL sequences with a good agreement between sequences. KEY POINTS: • MRI of the shoulder requires long scan times and can be hampered by motion artifacts. • Deep learning-based convolutional neural networks are used to reduce image noise and scan time while maintaining optimal image quality. The radial k-space acquisition technique (PROPELLER) can reduce the scan time and has potential to reduce motion artifacts. • DL sequences show a higher diagnostic confidence than conventional sequences and therefore are preferred for assessment of the subacromial bursa, while conventional and DL sequences show comparable performance in the evaluation of the shoulder joint.


Asunto(s)
Aprendizaje Profundo , Articulación del Hombro , Humanos , Articulación del Hombro/diagnóstico por imagen , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Artefactos
17.
BMC Geriatr ; 23(1): 743, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37964210

RESUMEN

BACKGROUND: Many older persons with degenerative physical functions use walking aids to improve their ambulation ability. The aim of this study was to investigate the effects of walking aids with different configurations on shoulder joint motion in older persons. METHODS: The 3D motion capture system VICON was applied to collect data on gait parameters and shoulder motion characteristics of 6 older persons walking either independently or with the assistance of a footed walking frame and a wheeled walking frame. The different effects of walking aids on gait parameters and the shoulder joint motion of older individuals were quantitatively analyzed. RESULTS: The gait parameters of the older individuals changed significantly when they used walking frames to assist walking. Compared to independent walking, the range of motion of the shoulder joint was reduced by 79.92% in flexion when walking with a wheeled walking frame. Meanwhile, the range of motion in flexion, extension, and external rotation increased by 76.04%, 85.55%, and 110.99%, respectively, when walking with a footed walking frame. CONCLUSION: The motion characteristics of shoulder joints in older persons were significantly affected by using different walking aids. These changes in shoulder joint motion characteristics will lead to potential diseases related to the shoulder musculoskeletal system. These findings are beneficial to determine a walking aid for older people.


Asunto(s)
Articulación del Hombro , Humanos , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Caminata , Marcha , Pie
18.
Acta Radiol ; 64(5): 1919-1926, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36775984

RESUMEN

BACKGROUND: The effect of different computed tomography (CT) scanning methods of the shoulder on image quality is uncertain. PURPOSE: To compare the effect of different methods of CT scanning of the right shoulder on image quality and radiation dose. MATERIAL AND METHODS: A total of 30 adults were divided into five groups. Group A received scans centered on the body's long axis, a scout direction of 0° + 90°, and automatic tube current modulation (ATCM). The other four groups (B, C, D, E) received isocenter scans centered on the shoulder with different scout directions (B and C: 0° + 90°, D: 0°, E: 0° + 270°) and tube currents (B: 420 mA; C, D, E: ATCM). The volume CT dose index (CTDIvol), dose-length product (DLP), image objective noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared. Three subjective measures were also compared (noise, stripe artifacts, diagnostic confidence). RESULTS: The five groups differed significantly in all subjective and objective indexes. The CTDIvol and DLP decreased in the order of groups C, A, B, E, and D; the differences between groups A and B were not significant (P > 0.05). Groups B, C, and E had better SNR and CNR than groups A and D (P < 0.01). Subjective evaluations indicated group D was worse than groups B, C, and E (P < 0.05). CONCLUSION: In the ATCM system that uses the last scout view, CT of the shoulder should use isocenter scanning with the lateral scout view when the tube is away from the long axis of the body as the last execution direction.


Asunto(s)
Hombro , Tomografía Computarizada por Rayos X , Adulto , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Relación Señal-Ruido , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
19.
BMC Musculoskelet Disord ; 24(1): 201, 2023 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-36932406

RESUMEN

BACKGROUND: Capsular contracture is a well-known etiology in the primary stiff shoulder; thus capsular contracture and resultant decreased joint volume could lead to postoperative stiffness, which is a commonly reported morbidity after arthroscopic rotator cuff repair (ARCR). The purpose of this study was (1) to quantify the joint volume (total joint volume and each quadrant compartmental volume) using computed tomography arthrography (CTA) and (2) to demonstrate the relationship between joint volume and postoperative range of motion (ROM) after ARCR. MATERIALS AND METHODS: Eighty-three patients (60 ± 5.11 years, men = 26, women = 57) who had undergone ARCR between January 2015 to December 2020 due to small to medium full-thickness tear and followed by CTA 6 months postoperatively were retrospectively reviewed. An image reconstruction program (3D Slicer, version 4.11.2 software) was used to calculate the joint volume (total joint volume and quadrant compartment joint volumes; anteroinferior, anterosuperior, posterosuperior and posteroinferior). For shoulder ROM, data including scaption (Sc), external rotation on side (ERs), external rotation at 90° (ER90), and internal rotation on back (IRb) were collected 6 months postoperatively. An evaluation of the correlation between joint volume and each shoulder motion was performed. RESULTS: There were moderate correlations between the total joint volume and each motion (Sc: Pearson coefficient, 0.32, p = 0.0047; ERs: Pearson coefficient, 0.24, p = 0.0296; ER90: Pearson coefficient, 0.33, p = 0.0023; IRb: Pearson coefficient, 0.23, p = 0.0336). Among the quadrant compartments, the anteroinferior (Sc: Pearson coefficient, 0.26, p = 0.0199; ERs: Pearson coefficient, 0.23, p = 0.0336; ER90: Pearson coefficient, 0.25, p = 0.0246; IRb: Pearson coefficient, 0.26, p = 0.0168) and posterosuperior (Sc: Pearson coefficient, 0.24, p = 0.029; ER90: Pearson coefficient, 0.29, p = 0.008; IRb: Pearson coefficient, 0.22, p = 0.0491) and posteroinferior (Sc: Pearson coefficient, 0.30, p = 0.0064; ER90: Pearson coefficient, 0.29, p = 0.0072) showed moderate correlations with each shoulder motion. CONCLUSION: Total joint volume, anteroinferior compartment joint volume, posterosuperior compartment joint volume and posteroinferior compartment joint volume were related to postoperative ROM after ARCR. Perioperative methods to increase the joint volume, especially the anteroinferior, posterosuperior and posteroinferior parts of the capsule may prevent postoperative stiffness after ARCR. LEVEL OF EVIDENCE: Level III; Retrospective Case-Control Study.


Asunto(s)
Contractura , Lesiones del Manguito de los Rotadores , Articulación del Hombro , Masculino , Humanos , Femenino , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/cirugía , Estudios Retrospectivos , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Estudios de Casos y Controles , Resultado del Tratamiento , Artroscopía/efectos adversos , Artroscopía/métodos , Rango del Movimiento Articular
20.
Skeletal Radiol ; 52(11): 2283-2296, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36287234

RESUMEN

Glenohumeral osteoarthritis (GHOA) is a widely prevalent disease with increasing frequency due to population aging. Both clinical manifestations and radiography play key roles in the initial diagnosis, staging, and management decisions. Radiographic disease progression evaluation is performed using validated staging systems, such as Kellgren and Lawrence, Samilson, and Hamada. For young patients with mild to moderate GHOA and failed conservative treatment, arthroscopic preservation surgery (APS) is usually considered. Older patients and those with severe GHOA benefit from different types of arthroplasties. Preoperative magnetic resonance imaging (MRI) is essential for APS surgical planning, as it maps repairable labral, cartilage, and rotator cuff lesions. For arthroplasty planning, the status of glenoid cartilage and intactness of rotator cuff as well as glenoid morphology represent key factors guiding the decision regarding the most suitable hardware design, whether resurfacing, partial, total, or reverse joint replacement. Pre-surgical MRI or alternatively computed tomography arthrogram is employed to evaluate the cartilage and rotator cuff. Finally, three-dimensional computed tomography (3D CT) is indicated to optimally assess the glenoid morphology (to determine Walch classification, version, inclination, and bone loss) and analyze the necessity for glenoid osteotomy or graft augmentation to correct the glenoid structural abnormalities for future success and longevity of the shoulder implants or chosen constructs. Understanding the purpose of each imaging and treatment modality allows more efficient image interpretation. This article reviews the above concepts and details what a surgeon needs from a radiologist and could benefit from accurate reporting of preoperative imaging studies.


Asunto(s)
Artroplastia de Reemplazo , Osteoartritis , Articulación del Hombro , Cirujanos , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Articulación del Hombro/patología , Artroplastia de Reemplazo/métodos , Osteoartritis/diagnóstico por imagen , Osteoartritis/cirugía , Radiólogos , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA