Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 177
Filtrar
1.
Ann Noninvasive Electrocardiol ; 29(1): e13104, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38288512

RESUMEN

OBJECTIVE: This study aimed to investigate the structure of the mitral valve in patients undergoing mitral valvuloplasty (MVP) using real-time three-dimensional transesophageal echocardiography (RT-3D-TEE). The main objective was to study the relationship between intraoperative annuloplasty ring size and mitral valve structure dimensions, with a focus on exploring the application value of RT-3D-TEE in MVP. METHODS: A total of 28 patients with degenerative mitral regurgitation (DMR), who underwent MVP between February and September 2022, as well as 12 normal control cases, were enrolled in this study. The MV annulus and leaflets were quantitatively analyzed using MVN software. RESULTS: The DMR group exhibited significantly greater dimensions in various parameters of the mitral valve, including the anterolateral-to-posteromedial diameter (DAlPm ), anterior-to-posterior diameter (DAP ), annulus height (HA ), three-dimensional annulus circumference (CA3D ), two-dimensional annulus area (AA2D ), anterior leaflet area (Aant ), posterior leaflet area (Apost ), anterior leaflet length (Lant ), posterior leaflet length (Lpost ), and tenting volume (Vtent ) compared to the control group. CONCLUSION: Real-time three-dimensional transesophageal echocardiography provides valuable insights into the morphological structure of the mitral valve and lesion location. It can aid in surgical decision-making, validate the success of MVP, and potentially reduce mortality and complications associated with mitral valve repair procedures.


Asunto(s)
Valvuloplastia con Balón , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Insuficiencia de la Válvula Mitral , Humanos , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Electrocardiografía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
2.
Echocardiography ; 41(10): e15945, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39432316

RESUMEN

Infective endocarditis (IE) continues to have high rates of adverse outcomes, despite recent advances in diagnosis and management. Although the use of computer tomography and nuclear imaging appears to be increasing, echocardiography, widely available in most centers, is the recommended initial modality of choice to diagnose and consequently guide the management of IE in a timely-dependent fashion. Echocardiographic imaging should be performed as soon as the IE diagnosis is suspected. Several factors may delay diagnosis, for example, echocardiography findings may be negative early in the disease course. Thus, repeated echocardiography is recommended in patients with negative initial echocardiography if high suspicion for IE persists in patients at high risk. However, systematic echocardiographic screening should not be utilized as a common tool for fever, but only in the presence of a reasonable clinical suspicion of IE. It may increase the risk of false-positive rates of patients requiring IE therapy or may exacerbate diagnostic uncertainty about subtle findings. Considering the complexity of the disease, the echocardiographic use should be increasingly time-efficient and should focus on the correct identification of IE lesions and associated complications. The path to identify patients who need surgery passes through an echocardiographic skill ensuring the identification of the cardiac anatomical structures and their involvement in the destructive infective extension. We pointed out the role of echocardiography focused on the correct identification of IE distinctive lesions and the associated complications, as part of a diagnostic strategy, within an integrated multimodality imaging, managed by an "endocarditis team".


Asunto(s)
Ecocardiografía , Endocarditis , Humanos , Endocarditis/diagnóstico por imagen , Ecocardiografía/métodos
3.
Echocardiography ; 41(10): e15943, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39387642

RESUMEN

BACKGROUND/AIM: Mitral regurgitation (MR) is frequently observed in non-valvular atrial fibrillation (NVAF) patients and is a significant risk factor for its progression. This study aims to investigate the three-dimensional anatomical characteristics of the mitral valve (MV) in patients with different types of NVAF to elucidate the underlying mechanisms of MR. METHODS: A retrospective analysis was conducted on 82 paroxysmal atrial fibrillation patients (PAF group) and 66 persistent atrial fibrillation patients (PerAF group) who underwent real-time three-dimensional transesophageal echocardiography (RT 3D-TEE) before initial ablation. Additionally, 30 patients undergoing RT 3D-TEE for the assessment of patent foramen ovale were selected as the control group. Basic echocardiographic variables were measured, left atrioventricular volume and strain parameters were calculated using automated software (Dynamic-HeartModel and AutoStrain). MV anatomic features were analyzed using the 4D-MV Assessment software (TomTec Imaging Systems). RESULTS: The maximum left atrial volume (LAVmax) was highest in the PerAF group, followed by the PAF and control groups, with statistically significant differences (p < 0.01). Left atrial reservoir strain (LASr) showed an opposite trend, being the lowest in the PerAF group (p < 0.01). The proportion of moderate to severe MR was significantly higher in the PerAF group (27.3%) compared to the PAF group (11.0%) (p < 0.01). Compared to controls, the AF groups exhibited mitral annular (MA) dilation, flattening of the MA plane, and increased leaflet area (all p < 0.05). Correlation analysis between effective regurgitant orifice area (EROA) and left atrioventricular structure and function parameters, as well as various annular parameters, showed that EROA was significantly correlated with left ventricular end-diastolic volume (LVEDV), LAVmax, LASr, anterior and posterior diameter, annular area, ratio of annular height to commissural diameter (AH/CD ratio), posterior leaflet area, posterior leaflet length, and the C-shaped annulus length (all p < 0.05). CONCLUSIONS: Significant remodeling of the MV apparatus occurs in NVAF patients, with more pronounced changes in PerAF patients, contributing to a higher incidence of moderate to severe MR. RT 3D-TEE-based MV automated assessment offers significant advantages in accurately diagnosing MV remodeling and supporting the evaluation of MR in NVAF patients.


Asunto(s)
Fibrilación Atrial , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Insuficiencia de la Válvula Mitral , Válvula Mitral , Humanos , Femenino , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Masculino , Ecocardiografía Transesofágica/métodos , Válvula Mitral/diagnóstico por imagen , Persona de Mediana Edad , Estudios Retrospectivos , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Programas Informáticos , Reproducibilidad de los Resultados , Interpretación de Imagen Asistida por Computador/métodos , Anciano
4.
Acta Cardiol Sin ; 40(3): 331-339, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38779166

RESUMEN

Background: The Laceration of the Anterior Mitral leaflet to Prevent Outflow ObtructioN (LAMPOON) procedure may be performed from the leaflet tip to base to prevent left ventricular outflow tract obstruction (LVOTO) in patients with high-risk anatomy undergoing valve-in-valve (VIV) or valve-in-(complete)-ring (VIR) transcatheter mitral valve replacement (TMVR). Methods and Results: Thirteen consecutive patients (6 females, average age 67.7 years) with a mean left ventricular ejection fraction of 60%, a median STS score of 3.2%, and degenerative surgical mitral bioprosthesis or ring were treated with a combined, single-stage procedure of preventive LAMPOON and trans-septal TMVR with SAPIEN 3 valves (Edwards Lifesciences, Irvine, CA). Under real-time 3-dimensional transesophageal echocardiography (RT 3D-TEE) guidance, we included the rendezvous technique in the LAMPOON procedure, and all 13 patients were successfully treated by tip-to-base LAMPOON and TMVR. The use of a modified LAMPOON procedure, aided by a rendezvous technique and guided by RT 3D-TEE imaging, offers precise guidance for positioning and aligning the guidewire. This approach not only reduces the need for fluoroscopy and shortens procedure times, but also significantly increases the likelihood of a successful outcome. Importantly, none of the patients in our study experienced unintentional aortic or aortic valve injuries, nor did they develop significant LVOTO following TMVR. In 11 of the 13 (85%) patients, we used a transcatheter SENTINELTM cerebral protection device (Boston Scientific, Marlborough, MA) for stroke prevention and capture of debris ≥ 2 mm were detected in 8/11 (73%) of the cases. Conclusions: Utilizing intra-operative RT 3D-TEE in conjunction with the rendezvous technique can make the tip-to-base LAMPOON procedure even safer and more effective for patients undergoing VIV or VIR TMVR. Our study also suggests that cerebral protection is indicated in patients undergoing TMVR.

5.
Cardiovasc Ultrasound ; 21(1): 6, 2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37076858

RESUMEN

BACKGROUND: Anatomical characteristics of the left atrium and the pulmonary veins (PVs) may be relevant to the success rate of cryoballoon (CB)-ablation for atrial fibrillation (AF). Cardiac computed tomography (CCT) is considered as the gold standard for preablation imaging. Recently, three-dimensional transesophageal echocardiography (3DTOE) has been proposed for preprocedural assessment of cardiac structures relevant to CB-ablation. The accuracy of 3DTOE has not been validated by other imaging modalities. OBJECTIVE: We prospectively evaluated the feasibility and the accuracy of 3DTOE imaging for the assessment of left atrial and PV structures prior to pulmonary vein isolation (PVI). In addition, CCT was used to validate the measurements obtained with 3DTOE. METHODS: PV anatomy of 67 patients (59.7% men, mean age 58.5 ± 10.5 years) was assessed using both 3DTOE and CCT scan prior to PVI with the Arctic Front CB. The following parameters were measured bilaterally: PV ostium area (OA), the major and minor axis diameters of the ostium (a > b) and the width of the carina between the superior and the inferior PVs. In addition, the width of the left lateral ridge (LLR) between the left atrial appendage and the left superior PV. Evaluation of inter-technique agreement was based on linear regression with Pearson correlation coefficient (PCC) and Bland-Altman analysis of biases and limits of agreement. RESULTS: Moderate positive correlation (PCC 0.5-0.7) was demonstrated between the two imaging methods for the right superior PV's OA and both axis diameters, the width of the LLR and left superior PV (LSPV) minor axis diameter (b) with limits of agreement ˂50% and no significant biases. Low positive or negligible correlation (PCC < 0.5) was found for both inferior PV parameters. CONCLUSIONS: Detailed assessment of the right superior PV parameters, LLR and LSPV b is feasible with 3DTOE prior to AF ablation. This 3DTOE measurements demonstrated a clinically acceptable inter-technique agreement with those obtained with CCT.


Asunto(s)
Fibrilación Atrial , Criocirugía , Venas Pulmonares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Ecocardiografía Transesofágica/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Criocirugía/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
6.
Echocardiography ; 39(7): 985-1000, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-33305429

RESUMEN

Three-dimensional echocardiography (3DE) has emerged in recent decades from a conceptual, research tool to an important, useful imaging technique that can informatively impact daily clinical practice. However, its adoption into the modern-day echo laboratory requires the acknowledgment of its value, coupled with proper leadership, education, and resources to implement and integrate its use with conventional echo techniques. 3DE integration involves important updates regarding equipment and patient selection, assimilation of 3D protocols into current clinical routine, laboratory workflow adaptation, storage, and reporting. This review will provide a practical blueprint and key points of how to integrate 3DE into today's echo laboratory, necessary resources to implement 3D workflow, logistical challenges that remain, and future directions to further improve assimilation of this relevant echo technique into the laboratory.


Asunto(s)
Ecocardiografía Tridimensional , Ecocardiografía Tridimensional/métodos , Humanos
7.
Echocardiography ; 39(7): 975-984, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-33095471

RESUMEN

The growth of transcatheter structural heart disease interventions has created a subspecialty of interventional imagers who focus on preprocedural planning and the periprocedural guidance of these complex cases. In particular interventional imagers who focus on periprocedural guidance have developed a specific expertise in interventional transesophageal echocardiography (iTEE). This nascent field has challenges in training, reimbursement, and occupational hazards which are unique to this field. This review encompasses the evolution of iTEE, current challenges, and future opportunities.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Ecocardiografía , Ecocardiografía Transesofágica , Humanos
8.
J Cardiothorac Vasc Anesth ; 36(11): 4001-4009, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35811278

RESUMEN

OBJECTIVE: The aim of the present study was to investigate the mitral annulus (MA) geometry and dynamic motion changes in patients with aortic regurgitation (AR) before and after aortic valve replacement (AVR). Moreover, the difference in the effect of the type of prosthetic aortic valve on MA was compared. DESIGN: Prospective observational study. SETTING: Cardiac operating room at a single hospital. PARTICIPANTS: Eighty-two patients with isolated moderate-to-severe AR who underwent AVR. Forty patients with normal valves were enrolled as controls. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The MA geometry and dynamic motion throughout the cardiac cycle were evaluated semiautomatically by three-dimensional transesophageal echocardiography. The severity of functional mitral regurgitation was intraoperatively evaluated. All patients were divided into 2 groups depending on the type of prosthetic valve (mechanical valve and bioprosthetic valve groups). Before AVR, compared with the control group without AR, the AR group demonstrated larger MA dimensions and the MA geometry was flatter. The contraction fraction of the MA area, perimeter, and height during the whole cardiac cycle were larger in the AR group (p < 0.05 for all). After AVR, most MA geometric and dynamic parameters decreased and functional mitral regurgitation also improved. In the postoperative subset analyses, the mechanical valve group showed a larger contraction fraction of the MA area and perimeter than the bioprosthetic valve group (p < 0.05 for both). CONCLUSIONS: The MA geometry and dynamic motion changed markedly in patients with AR. These spatial and dynamic changes were restored to a certain extent after surgical correction of the aortic valve. However, the effects produced by mechanical and bioprosthetic valves on MA were different.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
9.
J Cardiothorac Vasc Anesth ; 36(7): 2090-2097, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34275733

RESUMEN

The use of intraoperative three-dimensional (3D) transesophageal echocardiography (TEE) has grown exponentially in recent years. Three-dimensional TEE technology has evolved to allow for real-time display of 3D images and, thus, has become the standard of care for the evaluation of cardiac anatomy and function. Its use has provided a new dimension of clinical insight when managing patients for cardiac surgery or structural heart interventions. While the intraoperative utility of 3D TEE has expanded, there has been a slower advancement in the area of training and, specifically, simulator-based training in 3D TEE. This training is essential, as the skill set involved in acquiring 3D data sets differs from that of two-dimensional (2D) TEE and requires users to be able to appreciate how 3D anatomic display differs from that of tomographic cross-sectional 2D imaging. This added skill set requires mental reconstruction and spatial reorientation to appreciate the added elevational dimension in frustum-based imaging and is best achieved in a simulation environment rather than the busy operating room. In this review article, the authors evaluate the functionality of a 3D TEE simulator and how simulators such as this can establish preclinical proficiency in novices in the expanding area of advanced 3D TEE imaging.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ecocardiografía Tridimensional , Estudios Transversales , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Humanos
10.
BMC Cardiovasc Disord ; 21(1): 315, 2021 06 28.
Artículo en Inglés | MEDLINE | ID: mdl-34182931

RESUMEN

BACKGROUND: Our goal was to determine the accuracy of 3-dimensional transesophageal echocardiography (3D-TEE) compared with that of computed tomography (CT) in the preoperative evaluation for transcatheter aortic valve replacement (TAVR) when the errors caused by inconsistent software and method have been eliminated and the representativeness of the sample has been improved. We also investigated the influence of aortic root calcification on the accuracy of 3D-TEE in aortic annulus evaluations. METHODS: Part I: 45 of 233 patients who underwent TAVR in the department of cardiovascular surgery at the Xijing hospital from January 2016 to August 2019 were studied retrospectively. Materialise Mimics software and the multiplanar reconstruction method were used for evaluation, based on 3D-TEE and CT. The annulus area-derived diameter, the annulus perimeter-derived diameter (Dp), the annulus mean diameter, the left ventricular outflow tract Dp diameter, the sinotubular junction (STJ) diameter-Dp, and the aortic sinus diameter were compared and analyzed. Part II: 31 of 233 patients whose 3D-TEE and CT data were well preserved and in the required format were included. HU450 and HU850 were used as indicators to measure the severity of calcification. The Spearman rank correlation and Linear regression were used to analyze the correlation between aortic root calcification and the accuracy of 3D-TEE in aortic annulus measurement. RESULTS: The measurement results based on 3D-TEE were significantly lower than those obtained using CT (P < 0.05), except for the STJ diameter-Dp in diastole (P = 0.11). The correlation coefficient of the two groups was 0.699-0.954 (P < 0.01), which also indicated a significant correlation between the two groups. A Bland-Altman plot showed that the ordinate values were mostly within the 95% consistency limit; the consistency of the two groups was good. By establishing the linear regression equation, the two groups can be inferred from each other. The Spearman rank correlation analysis and the Linear regression analysis showed that the influence of aortic calcification on the accuracy of the 3D-TEE annulus evaluation was limited. CONCLUSIONS: Although an evaluation based on 3D-TEE underestimated the results, we can deduce CT results from 3D-TEE because the two methods exhibit considerable correlation and consistency. TRIAL REGISTRATION: Name: Surgery and Transcatheter Intervention for Structural Heart Diseases. Number: NCT02917980. URL: https://clinicaltrials.gov/ct2/results?term=NCT02917980 .


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Calcinosis/diagnóstico por imagen , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Calcinosis/fisiopatología , Calcinosis/cirugía , Toma de Decisiones Clínicas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X
11.
Echocardiography ; 38(6): 1070-1073, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33982822

RESUMEN

The use of 3D technology has significantly improved the diagnostic accuracy of echocardiography by overcoming the limitation of 2D echocardiography. Transillumination 3D image post processing technique enhances shadows and contrast of cardiac structures with a movable virtual light source improving further the clarity and detail provided by conventional 3D imaging. In this report, we present 3 cases, one of mobile atherosclerotic aortic root plaque, another of small thrombi on ICD lead, and a third case of bicuspid aortic valve perforation due to infective endocarditis in whom TEE 3D transillumination further improved the diagnostic quality of conventional 3D imaging and lead to accurate clinical diagnosis.


Asunto(s)
Ecocardiografía Tridimensional , Endocarditis , Ecocardiografía Transesofágica , Humanos , Iluminación , Transiluminación
12.
J Cardiothorac Vasc Anesth ; 35(6): 1663-1669, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33268041

RESUMEN

OBJECTIVE: This study aimed to compare measurements of right ventricular function using three-dimensional transesophageal echocardiography (3D TEE), and pulmonary artery catheters (PACs) in patients undergoing cardiac surgery. The authors examined the practicality of using the 3D TEE. DESIGN: Prospective observational. SETTING: Cardiac operating room at a single university hospital. PARTICIPANTS: All adult patients undergoing elective cardiac surgery at a single tertiary care university hospital over two years. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Right ventricular end-diastolic volume (RVEDV), right ventricular end-systolic volume (RVESV), stroke volume (SV), and right ventricular ejection fraction (RVEF) were measured with both 3D TEE and PACs. Assessments were performed using correlation coefficients, paired t tests, and Bland-Altman plots. Thirty-one patients participated in this study. Each measurement showed good agreement. RVEDV and RVESV were slightly lower on 3D TEE than on PAC (205.9 mL v 220.2 mL, p = 0.0018; 143.0 mL v 155.5 mL, p = 0.0143, respectively), whereas no significant differences were observed for SV and RVEF (31.0% v 31.1%, p = 0.0569; 61.6 mL v 66.9 mL, p = 0.92, respectively). Linear regression analysis showed high correlation between 3D TEE and PAC for RVEDV (r = 0.87) and RVESV (r = 0.81), and moderate correlation for SV (r = 0.67) and RVEF (r = 0.67). In the Bland-Altman plot, most patients were within the 95% limits of the agreement throughout all measurements. CONCLUSION: A high correlation was found between measurements made with a PAC and with 3D TEE in the assessment of right ventricular function. Three-dimensional TEE would be a potential alternative to PAC for assessment of right ventricular function during intraoperative periods.


Asunto(s)
Ecocardiografía Tridimensional , Función Ventricular Derecha , Adulto , Catéteres , Ecocardiografía Transesofágica , Humanos , Arteria Pulmonar/diagnóstico por imagen , Volumen Sistólico
13.
J Cardiothorac Vasc Anesth ; 35(9): 2723-2731, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33436281

RESUMEN

OBJECTIVES: The primary objective of the present study was to compare cardiac output derived with four methods of QLab (Philips, Amsterdam, Netherlands) software using real-time three-dimensional (3D) transesophageal echocardiography, with cardiac output obtained with the 3D left ventricular outflow tract (LVOT) cardiac output method. The secondary objective was to assess left ventricular (LV) volumes, LV ejection fraction, and cardiac output derived with four different methods of real time 3D transesophageal echocardiography processed in QLab software and to determine whether these parameters differed among these four methods. DESIGN: A prospective observational study. SETTING: A tertiary referral center and a university level teaching hospital. PARTICIPANTS: The study comprised 50 patients scheduled for elective coronary artery bypass surgery without any concomitant valvular lesions. MEASUREMENTS AND MAIN RESULTS: Three-dimensional full-volume datasets were obtained in optimum conditions. The 3D datasets were analyzed using four different methods in QLab, version 9. In method A, LV volumes were derived without endocardial border adjustment. In method B, LV volumes were obtained after endocardial border adjustment in the long-axis view alone. In method C, the iSlice tool (Philips) was used to adjust the endocardial borders in 16 short-axis slices. In method D, endocardial borders were adjusted after dataset processing to obtain LV volumes. The cardiac output derived with the 3D echocardiography LVOT method was 3.93 ± 1.44 L/min, with method A was 3.26 ± 1.42 L/min, with method B was 3.51 ± 1.2 L/min, with method C was 4.01 ± 1.40 L/min, and with method D was 4.18 ± 1.58 L/min. There was a significant positive correlation between the cardiac output derived using the 3D LVOT method and method C (r = 0.71). CONCLUSIONS: Readjusting the endocardial border contours resulted in higher LV volumes than the volumes estimated using semiautomated border algorithms. The iSlice method produced the highest and the most accurate LV volumes, although it required the longest time to analyze and derive results. The ejection fraction obtained with all four methods of QLab demonstrated no statistical differences and had a strong correlation with the two-dimensional echocardiography-derived left ventricular ejection fraction.


Asunto(s)
Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Reproducibilidad de los Resultados , Volumen Sistólico , Función Ventricular Izquierda
14.
Medicina (Kaunas) ; 58(1)2021 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-35056331

RESUMEN

Despite advances in diagnosis, imaging methods, and medical and surgical interventions, prosthetic valve endocarditis (PVE) remains an extremely serious and potentially fatal complication of heart valve surgery. Characteristic changes of PVE are more difficult to detect by transthoracic echocardiography (TTE) than those involving the native valve. We reviewed advances in transesophageal echocardiography (TEE) in the diagnosis of PVE. Three-dimensional (3D) TEE is becoming an increasingly available imaging method combined with two-dimensional TEE. It contributes to faster and more accurate diagnosis of PVE, assessment of PVE-related complications, monitoring effectiveness of antibiotic treatment, and determining optimal time for surgery, sometimes even before or without previous TTE. In this article, we present advances in the treatment of patients with mitral PVE due to 3D TEE application.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Ecocardiografía , Ecocardiografía Transesofágica , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/tratamiento farmacológico , Prótesis Valvulares Cardíacas/efectos adversos , Humanos
15.
Artif Organs ; 44(11): 1192-1201, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32530056

RESUMEN

Right ventricular (RV) failure is significantly associated with morbidity and mortality after left ventricular assist device (LVAD) implantation. However, it remains unclear whether LVAD implantation could worsen RV function. Therefore, we aimed to investigate the effect of LVAD implantation on RV function by comparing RV energetics derived from the RV pressure-volume curve between before and after LVAD implantation. This exploratory observational study was performed between September 2016 and January 2018 at a national center in Japan. Twenty-two patients who underwent LVAD implantation were included in the analysis. We measured RV energetics parameters: RV stroke work index (RVSWI), which was calculated by integrating the area within the RV pressure-volume curve; RV minute work index (RVMWI), which was calculated as RVSWI × heart rate; and right ventriculo-arterial coupling, which was estimated as RV stroke volume/RV end-systolic volume. We compared RV energetics between before and after LVAD implantation. Although RVSWI was similar [424.4 mm Hg · mL/m2 (269.5-510.3) vs. 379.9 mm Hg · mL/m2 (313.1-608.8), P = 0.485], RVMWI was significantly higher after LVAD implantation [29 834.1 mm Hg · mL/m2 /min (18 272.2-36 357.1) vs. 38 544.8 mm Hg · mL/m2 /min (29 016.0-57 282.8), P = 0.001], corresponding to a significantly higher cardiac index [2.0 L/min/m2 (1.4-2.2) vs. 3.7 L/min/m2 (3.3-4.1), P < 0.001] to match LVAD flow. Right ventriculo-arterial coupling was significantly higher after LVAD implantation [0.360 (0.224-0.506) vs. 0.480 (0.343-0.669), P = 0.025], suggesting that the efficiency of RV performance improved. In conclusion, higher RVMWI with higher cardiac index to match LVAD flow and improved efficiency of RV performance indicate that LVAD implantation might not worsen RV function.


Asunto(s)
Ventrículos Cardíacos/cirugía , Corazón Auxiliar , Función Ventricular Derecha , Adulto , Femenino , Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Disfunción Ventricular Derecha/etiología , Presión Ventricular
16.
Echocardiography ; 37(11): 1860-1863, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33007127

RESUMEN

A patient with heart failure due to dilated ischemic cardiomyopathy presented in cardiogenic shock for institution of veno-arterial extracorporeal membrane oxygenation as a bridge to cardiac transplantation. To provide adequate venous drainage and simultaneous decompression of the left atrium (indirect left ventricular venting), a single venous cannula was placed across the interatrial septum so that the distal orifice and side ports were located within the left atrium and the proximal set of side ports were positioned at the cavoatrial junction. Three-dimensional transesophageal echocardiography demonstrated utility in guiding cannula placement and appropriate positioning within the left atrium.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Cánula , Drenaje , Ecocardiografía Transesofágica , Humanos , Choque Cardiogénico/diagnóstico por imagen , Choque Cardiogénico/terapia
17.
Echocardiography ; 37(11): 1828-1837, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33007129

RESUMEN

BACKGROUND: The aim of this study was to investigate the utility of perimeter-derived diameter (PDD) measured by three-dimensional (3D) transesophageal echocardiography (TEE) in predicting the size of left atrial appendage (LAA) occluder. METHODS AND RESULTS: Left atrial appendage landing zone diameter (LZD) was measured by two-dimensional (2D) TEE, 3DTEE, and digital subtraction angiography (DSA) as LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD, LZD-DSAmax, respectively, before and during transcatheter LAA closure with Watchman devices in 100 patients. A difference of one or more device size intervals between the predicted size and the size actually implanted was defined as mismatching. Seventy-eight patients were followed up by TEE to obtain occluder compression ratio. The correlation between LZD and the final implanted occluder size was 0.559, 0.641, 0.754, 0.760, 0.782, and 0.848 for LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD and LZD-DSAmax, respectively (P < .001). Matching ratio between the size predicted by retrospective measurements of LZD and the device size actually implanted was 65%, 57%, 66%, 63%, 70%, and 83% for LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD and LZD-DSAmax, respectively. There was no significant difference in LZD value, matching ratio, and compression ratio between the patients with eccentric and noneccentric LAA landing zone (P > .05). Compression ratio of the mismatching subjects was higher than that in the matching subjects when evaluated by LZD-2Dmean, LZD-3Dmean, and LZD-PDD (P < .05). CONCLUSIONS: Landing zone diameter derived from LAA perimeter measured by preprocedure 3DTEE showed reference value for LAA occluder size selection, providing superior correlation and matching ratio with the final implanted size and indicating the adjustment of oversizing.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ecocardiografía Tridimensional , Dispositivo Oclusor Septal , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Humanos , Valores de Referencia , Estudios Retrospectivos , Resultado del Tratamiento
18.
Echocardiography ; 37(6): 954-964, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32449807

RESUMEN

Prosthetic paravalvular leak (PVL) is a well-known serious complication following surgically as well as percutaneously implanted prosthetic valves. It usually happens due to incomplete sealing of the prosthetic ring to the native cardiac tissue whether immediately postoperative or considerably later as a complication of infective endocarditis, etc Surgery has been always the treatment of choice for clinically significant PVLs. However, percutaneous transcatheter closure therapy has become a successful alternative in carefully selected group of patients. Echocardiography is a cornerstone in the initial diagnosis, assessment of the severity and location of the PVL. Furthermore, it plays a crucial role in the assessment of the feasibility for percutaneous closure and during intra-procedural guidance. Transesophageal echocardiography (TEE) has the advantage over transthoracic echocardiography (TTE) of not being affected by the acoustic shadow of the mitral prosthesis that usually hides the regurgitation jets and makes TTE evaluation difficult. Three-dimensional (3D) TEE has been shown to provide better diagnostic accuracy compared to two-dimensional (2D) TEE as regard to evaluation of PVLs especially in patients with more than one PVL. This is due to better delineation of the location, shape, and size of the PVL and equally important during guiding the transcatheter percutaneous closure.


Asunto(s)
Ecocardiografía Tridimensional , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco , Ecocardiografía , Ecocardiografía Transesofágica , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
19.
Echocardiography ; 37(1): 142-146, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31841222

RESUMEN

INTRODUCTION: Patients with apical myocardial infarction are at higher risk of developing left ventricular (LV) thrombi. Standard transesophageal echocardiography (TEE) is commonly used in assessing cardiac source of embolic cerebrovascular accident (CVA). Contrast-enhanced transthoracic echocardiography (TTE) improves sensitivity for thrombus detection compared with noncontrast TTE, and however for LV apical thrombi, contrast-enhanced magnetic resonance imaging (MRI) and/or contrast-enhanced computed tomography (CT) outperform both TTE and TEE in some studies. CASE: A 67-year-old man with history of prior myocardial infarction (MI), four-vessel coronary artery bypass surgery, congestive heart failure with LV ejection fraction of 30%, and diabetes mellitus presented to our facility with acute right occipital-parietal stroke and recent history of left lower extremity ischemia. Head and neck MRI and MR angiography found multiple posterior circulation infarcts suggestive of cardio-embolic etiology. TTE image quality was suboptimal even after contrast use to evaluate for LV thrombus, and due to renal insufficiency, MRI or CT was precluded and 3DTEE identified large LV apical thrombus with mobile components. CONCLUSION: 3DTEE may increase the detection of LV apical thrombi as well as evaluating its characteristics by live imaging as well as by offline reconstruction. TEE may be a useful diagnostic modality, especially in patients with decreased renal function, where iodinated contrast for cardiac CT or Gadolinium for MRI may be contraindicated. Multimodality imaging studies may further prove the utility of 3D echocardiographic imaging in the detection of LV apical thrombus.


Asunto(s)
Ecocardiografía Tridimensional , Trombosis , Anciano , Ecocardiografía , Ecocardiografía Transesofágica , Humanos , Masculino , Volumen Sistólico , Trombosis/diagnóstico por imagen
20.
Echocardiography ; 37(7): 1049-1055, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32634292

RESUMEN

BACKGROUND: Detailed multidimensional assessment of patent foramen ovale (PFO) size with transesophageal echocardiography (TOE) may help to determine PFO pathogenicity in cryptogenic stroke patients. We explored the potential additive value of Live xPlane and three-dimensional (3D) TOE anatomical PFO sizing techniques. METHODS: Imaging data of 45 patients who underwent a 3D TOE-assisted percutaneous PFO closure were studied. The two-dimensional (2D) PFO separation distance and right-to-left (RL) contrast shunt magnitude were assessed on preprocedural TOE recordings. Peri-procedural measurements of the triangular anatomical PFO opening (base, height, and area) were performed after positioning of a stiff guidewire (SW) through the PFO, using Live xPlane imaging and 3D Zoom mode. RESULTS: The PFO SW base appeared on average 5 times larger than the preprocedural 2D PFO separation (median difference [IQR] = 13[5] mm; P < .001). For a same PFO separation, the width of the PFO base may vary significantly. The PFO SW base was significantly larger in patients with a large versus a small-to-moderate PFO RL contrast shunt (18 vs 15 mm; P = .007) and in those with a spontaneous versus a provoked shunt (18 vs 14 mm; P = .003). CONCLUSION: Live xPlane and 3D Zoom TOE allow peri-procedural measurement of the largest dimension of a PFO, which is the PFO base. Patients with a large or spontaneous RL contrast shunt appear to have a larger PFO base. The anatomical PFO base dimension may be taken into account for optimization of device and patient selection strategies.


Asunto(s)
Ecocardiografía Tridimensional , Foramen Oval Permeable , Accidente Cerebrovascular , Cateterismo Cardíaco , Ecocardiografía , Ecocardiografía Transesofágica , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/diagnóstico por imagen , Humanos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA