Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38989913

RESUMEN

AIMS: Transvenous lead extraction (TLE) is potentially complicated by significant tricuspid valve regurgitation increase (TRI). However, there are limited data on the effect of the bidirectional rotational mechanical sheaths on significant TRI. The aim of the present study was to investigate the rate of significant changes in tricuspid regurgitation (TR) severity following mechanical rotational TLE and their outcomes. METHODS AND RESULTS: In 158 patients (mean age 66 ± 16.9 years) undergoing mechanical rotational TLE, acute changes in TR severity were assessed by echocardiography evaluation. A significant acute TRI was defined as an increase of at least one grade with a post-extraction severity at least moderate. A total of 290 leads were extracted (mean implant duration, 93 ± 65 months). Significant TRI was noted in 5.7% of patients, and it was linked to tricuspid valve damage, TLE infection indication, and longer lead implant duration. Univariate predictors of significant TRI included implant duration of all leads [odds ratio (OR) 1.01; 95% confidence interval (CI) 1.003-1.018; P = 0.001] and right ventricular leads (OR 1.01; 95% CI 1.004-1.017; P = 0.002). Severe increase of TR following TLE was an independent predictor of mortality [hazard ratio (HR) 5.20; 95% CI 1.44-18.73; P = 0.012 ] along with severe systolic dysfunction (HR 2.37; 95% CI 1.01-5.20; P = 0.032), and systemic infection (HR 2.28; 95% CI 1.06-4.89; P = 0.035). CONCLUSION: Significant TRI was detected in 5.7% of patients following transvenous rotational mechanical lead extraction. The duration of lead implantation emerged as the sole predictor of significant TRI. Physicians engaged in TLE should exercise greater vigilance for this potential complication.


Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/etiología , Masculino , Femenino , Remoción de Dispositivos/efectos adversos , Anciano , Persona de Mediana Edad , Desfibriladores Implantables/efectos adversos , Anciano de 80 o más Años , Índice de Severidad de la Enfermedad , Factores de Riesgo , Resultado del Tratamiento , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Factores de Tiempo
3.
Artículo en Inglés | MEDLINE | ID: mdl-36231579

RESUMEN

BACKGROUND: Damage to the tricuspid valve (TVD) is now considered either a major or minor complication of the transvenous lead extraction procedure (TLE). As yet, the risk factors and long-term survival after TLE in patients with TVD have not been analyzed in detail. METHODS: This post hoc analysis used clinical data of 2631 patients (mean age 66.86 years, 39.64% females) who underwent TLE procedures performed in three high-volume centers. The risk factors and long-term survival of patients with worsening tricuspid valve (TV) function after TLE were analyzed. RESULTS: In most procedures (90.31%), TLE had no negative influence on TV function, but in 9.69% of patients, a worsening of tricuspid regurgitation (TR) to varying degrees was noted, including significant dysfunction in 2.54% of patients. Risk factors of TLE relating to severe TVD were: TLE of pacing leads (5.264; p = 0.029), dwell time of the oldest extracted lead (OR = 1.076; p = 0.032), strong connective scar tissue connecting a lead with tricuspid apparatus (OR = 5.720; p < 0.001), and strong connective scar tissue connecting a lead with the right ventricle wall (OR = 8.312; p < 0.001). Long-term survival (1650 ± 1201 [1-5519] days) of patients with severe TR was comparable to patients without tricuspid damage related to TLE. CONCLUSIONS: Severe tricuspid valve damage related to TLE is relatively rare (2.5%). The main risk factors for the worsening of TV function are associated with a longer lead dwell time (more often the pacing lead), causing stronger connective tissue scars connecting the lead to the tricuspid apparatus and right ventricle. TVD is unlikely to affect long-term survival after TLE.


Asunto(s)
Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Anciano , Cicatriz/complicaciones , Femenino , Humanos , Plomo , Masculino , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología
4.
Cardiovasc Diagn Ther ; 11(2): 394-410, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33968618

RESUMEN

BACKGROUND: In patients undergoing transvenous lead extraction (TLE) transesophageal echocardiography (TEE) provide valuable information after procedure. METHODS: We analyzed data from 936 TEE performed in patients undergoing TLE between 2015 and 2019 (mean follow-up 566.23±224.47 days) and assessed the role of echocardiographic phenomena after procedure. RESULTS: Increment in tricuspid regurgitation (TR) was observed in 9% of patients after TLE. Factors increasing the risk of TR were: binding sites between lead and right ventricle (RV) (OR: 5.429), tricuspid valve (TV) (OR: 3.42), superior vena cava (SVC) (OR: 3.30) and lead-to-lead adhesions (OR: 2.88). Predisposing factors of residual structures after TLE were: asymptomatic masses on the leads (AMEL) (OR: 1.68), binding sites between SVC and cardiac structures (OR: 1.72), and multiple leads (OR: 1.30). Probability of vegetation remnants increased in the presence of abandoned leads (OR: 7.91). The risk factors of tamponade were: dwell time of the oldest lead (OR: 1.17), lead-to-lead adhesion (OR: 22.47), binding sites between lead and TV (OR: 6.08), RA (OR: 11.50), SVC (OR: 4.47), higher LVEF (OR: 2.35; P=0.006), female gender (OR: 5.43), multiple leads (OR: 2.11), looped leads (OR: 4.90) and AMEL (OR: 6.42). The risk of lead fracture was increased by: lead-to-lead adhesion (OR: 5.69), fibrosis binding the lead to RV (OR: 5.16), RA (OR: 2.39) and dwell time of the oldest lead (OR: 1.068). The mortality rate was 11.97% during follow-up. The risk of death was increased by: severe TR and vegetation remnants. CONCLUSIONS: The most important phenomena evaluated after TLE are: tricuspid valve function, residual fibrosis and vegetation remnants, progression of pericardial effusion and retained lead fragments. Postoperative TEE provides information about the results of TLE and helps establish further management.

5.
Artículo en Inglés | MEDLINE | ID: mdl-34639716

RESUMEN

Background: Transvenous lead extraction (TLE) is the preferred management strategy for complications related to cardiac implantable electronic devices. TLE sometimes can cause serious complications. Methods: Outcomes of TLE procedures using non-powered mechanical sheaths were analyzed in 1500 patients (mean age 68.11 years; 39.86% females) admitted to two high-volume centers. Results: Complete procedural success was achieved in 96.13% of patients; clinical success in 98.93%, no periprocedural death occurred. Mean lead dwell time in the study population was 112.1 months. Minor complications developed in 115 (7.65%), major complications in 33 (2.20%) patients. The most frequent minor complications were tricuspid valve damage (TVD) (3.20%) and pericardial effusion that did not necessitate immediate intervention (1.33%). The most common major complication was cardiac laceration/vascular tear (1.40%) followed by an increase in TVD by two or three grades to grade 4 (0.80%). Conclusions: Despite the long implant duration (112.1 months) satisfying results without procedure-related death can be obtained using mechanical tools. Lead remnants or severe tricuspid regurgitation was the principal cause of lack of clinical and procedural success. Worsening TR(Tricuspid regurgitation) (due to its long-term consequences), but not cardiac/vascular wall damage; is still the biggest TLE-related problem; when non-powered mechanical sheaths are used as first-line tools.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Anciano , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos , Femenino , Humanos , Plomo , Masculino , Derivación y Consulta , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA