Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 448
Filtrar
1.
J Neuroeng Rehabil ; 21(1): 127, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39080666

RESUMEN

OBJECTIVE: The objective of this study was to analyze the safety and efficacy of using a robotic hip exoskeleton designed by Samsung Electronics Co., Ltd., Korea, called the Gait Enhancing and Motivating System-Hip (GEMS-H), in assistance mode only with the poststroke population in an outpatient-rehabilitation setting. METHODS: Forty-one participants with an average age of 60 and average stroke latency of 6.5 years completed this prospective, single arm, interventional, longitudinal study during the COVID-19 pandemic. Significant modifications to the traditional outpatient clinical environment were made to adhere to organizational physical distancing policies as well as guidelines from the Centers for Disease Control. All participants received gait training with the GEMS-H in assistance mode for 18 training sessions over the course of 6-8 weeks. Performance-based and self-reported clinical outcomes were assessed at four time points: baseline, midpoint (after 9 training sessions), post (after 18 training sessions), and 1-month follow up. Daily step count was also collected throughout the duration of the study using an ankle-worn actigraphy device. Additionally, corticomotor excitability was measured at baseline and post for 4 bilateral lower limb muscles using transcranial magnetic stimulation. RESULTS: By the end of the training program, the primary outcome, walking speed, improved by 0.13 m/s (p < 0.001). Secondary outcomes of walking endurance, balance, and functional gait also improved as measured by the 6-Minute Walk Test (47 m, p < 0.001), Berg Balance Scale (2.93 points, p < 0.001), and Functional Gait Assessment (1.80 points, p < 0.001). Daily step count significantly improved with and average increase of 1,750 steps per day (p < 0.001). There was a 35% increase in detectable lower limb motor evoked potentials and a significant decrease in the active motor threshold in the medial gastrocnemius (-5.7, p < 0.05) after training with the device. CONCLUSIONS: Gait training with the GEMS-H exoskeleton showed significant improvements in walking speed, walking endurance, and balance in persons with chronic stroke. Day-to-day activity also improved as evidenced by increased daily step count. Additionally, corticomotor excitability changes suggest that training with this device may help correct interhemispheric imbalance typically seen after stroke. TRIAL REGISTRATION: This study is registered with ClinicalTrials.gov (NCT04285060).


Asunto(s)
Dispositivo Exoesqueleto , Rehabilitación de Accidente Cerebrovascular , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Marcha/fisiología , Cadera , Estudios Longitudinales , Pacientes Ambulatorios , Estudios Prospectivos , Accidente Cerebrovascular , Rehabilitación de Accidente Cerebrovascular/instrumentación , Rehabilitación de Accidente Cerebrovascular/métodos , Estimulación Magnética Transcraneal/instrumentación , Resultado del Tratamiento
2.
Sensors (Basel) ; 24(12)2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38931623

RESUMEN

As a noninvasive neuromodulation technique, transcranial magnetic stimulation (TMS) has important applications both in the exploration of mental disorder causes and the treatment of mental disorders. During the stimulation, the TMS system generates the intracranial time-varying induced E-field (E-field), which alters the membrane potential of neurons and subsequently exerts neural regulatory effects. The temporal waveform of the induced E-fields is directly related to the stimulation effect. To meet the needs of scientific research on diversified stimulation waveforms and flexible adjustable stimulation parameters, a novel efficient pulse magnetic stimulation circuit (the EPMS circuit) design based on asymmetric cascaded multilevel technology is proposed in this paper. Based on the transient analysis of the discharge circuit, this circuit makes it possible to convert the physical quantity (the intracranial induced E-field) that needs to be measured after magnetic stimulation into easily analyzable electrical signals (the discharge voltage at both ends of the stimulation coil in the TMS circuit). This EPMS circuit can not only realize monophasic and biphasic cosine-shaped intracranial induced E-fields, which are widely used in the market, but also realize three types of new intracranial induced E-field stimulation waveform with optional amplitude and adjustable pulse width, including monophasic near-rectangular, biphasic near-rectangular and monophasic/biphasic ladder-shaped stimulation waveform, which breaks through the limitation of the stimulation waveform of traditional TMS systems. Among the new waveforms produced by the EPMS circuit, further research was conducted on the dynamic response characteristics of neurons under the stimulation of the biphasic four-level waveform (the BFL waveform) with controllable parameters. The relationship between TMS circuit parameters (discharge voltage level and duration) and corresponding neural response characteristics (neuron membrane potential change and neuronal polarizability ratio) was explained from a microscopic perspective. Accordingly, the biological physical quantities (neuronal membrane potential) that are difficult to measure can be transformed into easily analyzable electrical signals (the discharge voltage level and duration). Results showed that compared with monophasic and biphasic cosine induced E-fields with the same energy loss, the neuron polarization ratio is decreased by 54.5% and 87.5%, respectively, under the stimulation of BFL waveform, which could effectively enhance the neuromodulation effect and improve the stimulation selectivity.


Asunto(s)
Estimulación Magnética Transcraneal , Estimulación Magnética Transcraneal/métodos , Estimulación Magnética Transcraneal/instrumentación , Humanos , Neuronas/fisiología , Animales , Diseño de Equipo
3.
Sensors (Basel) ; 24(10)2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38793907

RESUMEN

(1) Background: This study evaluates the effectiveness of low-frequency repetitive transcranial magnetic stimulation (LF-rTMS) in improving gait in post-stroke hemiplegic patients, using wearable sensor technology for objective gait analysis. (2) Methods: A total of 72 stroke patients were randomized into control, sham stimulation, and LF-rTMS groups, with all receiving standard medical treatment. The LF-rTMS group underwent stimulation on the unaffected hemisphere for 6 weeks. Key metrics including the Fugl-Meyer Assessment Lower Extremity (FMA-LE), Berg Balance Scale (BBS), Modified Barthel Index (MBI), and gait parameters were measured before and after treatment. (3) Results: The LF-rTMS group showed significant improvements in the FMA-LE, BBS, MBI, and various gait parameters compared to the control and sham groups (p < 0.05). Specifically, the FMA-LE scores improved by an average of 5 points (from 15 ± 3 to 20 ± 2), the BBS scores increased by 8 points (from 35 ± 5 to 43 ± 4), the MBI scores rose by 10 points (from 50 ± 8 to 60 ± 7), and notable enhancements in gait parameters were observed: the gait cycle time was reduced from 2.05 ± 0.51 s to 1.02 ± 0.11 s, the stride length increased from 0.56 ± 0.04 m to 0.97 ± 0.08 m, and the walking speed improved from 35.95 ± 7.14 cm/s to 75.03 ± 11.36 cm/s (all p < 0.001). No adverse events were reported. The control and sham groups exhibited improvements but were not as significant. (4) Conclusions: LF-rTMS on the unaffected hemisphere significantly enhances lower-limb function, balance, and daily living activities in subacute stroke patients, with the gait parameters showing a notable improvement. Wearable sensor technology proves effective in providing detailed, objective gait analysis, offering valuable insights for clinical applications in stroke rehabilitation.


Asunto(s)
Marcha , Rehabilitación de Accidente Cerebrovascular , Accidente Cerebrovascular , Estimulación Magnética Transcraneal , Dispositivos Electrónicos Vestibles , Humanos , Masculino , Femenino , Estimulación Magnética Transcraneal/métodos , Estimulación Magnética Transcraneal/instrumentación , Persona de Mediana Edad , Accidente Cerebrovascular/fisiopatología , Accidente Cerebrovascular/terapia , Marcha/fisiología , Anciano , Rehabilitación de Accidente Cerebrovascular/instrumentación , Rehabilitación de Accidente Cerebrovascular/métodos , Análisis de la Marcha/métodos
4.
Neuroimage ; 241: 118437, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34332043

RESUMEN

The Transcranial Magnetic Stimulation (TMS) inverse problem (TMS-IP) investigated in this study aims to focus the TMS induced electric field close to a specified target point defined on the gray matter interface in the M1HAND area while otherwise minimizing it. The goal of the study is to numerically evaluate the degree of improvement of the TMS-IP solutions relative to the well-known sulcus-aligned mapping (a projection approach with the 90∘ local sulcal angle). In total, 1536 individual TMS-IP solutions have been analyzed for multiple target points and multiple subjects using the boundary element fast multipole method (BEM-FMM) as the forward solver. Our results show that the optimal TMS inverse-problem solutions improve the focality - reduce the size of the field "hot spot" and its deviation from the target - by approximately 21-33% on average for all considered subjects, all observation points, two distinct coil types, two segmentation types, two intracortical observation surfaces under study, and three tested values of the field threshold. The inverse-problem solutions with the maximized focality simultaneously improve the TMS mapping resolution (differentiation between neighbor targets separated by approximately 10 mm) although this improvement is quite modest. Coil position/orientation and conductivity uncertainties have been included into consideration as the corresponding de-focalization factors. The present results will change when the levels of uncertainties change. Our results also indicate that the accuracy of the head segmentation critically influences the expected TMS-IP performance.


Asunto(s)
Mapeo Encefálico/normas , Encéfalo/fisiología , Campos Electromagnéticos , Solución de Problemas/fisiología , Estimulación Magnética Transcraneal/normas , Mapeo Encefálico/instrumentación , Mapeo Encefálico/métodos , Conectoma/instrumentación , Conectoma/métodos , Conectoma/normas , Fenómenos Electromagnéticos , Humanos , Estimulación Magnética Transcraneal/instrumentación , Estimulación Magnética Transcraneal/métodos
5.
Acta Neuropsychiatr ; 33(5): 242-253, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33926587

RESUMEN

OBJECTIVES: Previous studies have examined the effect of transcranial direct current stimulation (tDCS) on the in-vivo concentrations of neuro-metabolites assessed through magnetic resonance spectroscopy (MRS) in neurological and psychiatry disorders. This review aims to systematically evaluate the data on the effect of tDCS on MRS findings and thereby attempt to understand the potential mechanism of tDCS on neuro-metabolites. METHODS: The relevant literature was obtained through PubMed and cross-reference (search till June 2020). Thirty-four studies were reviewed, of which 22 reported results from healthy controls and 12 were from patients with neurological and psychiatric disorders. RESULTS: The evidence converges to highlight that tDCS modulates the neuro-metabolite levels at the site of stimulation, which, in turn, translates into alterations in the behavioural outcome. It also shows that the baseline level of these neuro-metabolites can, to a certain extent, predict the outcome after tDCS. However, even though tDCS has shown promising effects in alleviating symptoms of various psychiatric disorders, there are limited studies that have reported the effect of tDCS on neuro-metabolite levels. CONCLUSIONS: There is a compelling need for more systematic studies examining patients with psychiatric/neurological disorders with larger samples and harmonised tDCS protocols. More studies will potentially help us to understand the tDCS mechanism of action pertinent to neuro-metabolite levels modulation. Further, studies should be conducted in psychiatric patients to understand the neurological changes in this population and potentially unravel the neuro-metabolite × tDCS interaction effect that can be translated into individualised treatment.


Asunto(s)
Espectroscopía de Resonancia Magnética/métodos , Trastornos Mentales/metabolismo , Enfermedades del Sistema Nervioso/metabolismo , Estimulación Transcraneal de Corriente Directa/efectos adversos , Adulto , Anciano , Estudios de Casos y Controles , Corteza Cerebelosa/metabolismo , Corteza Prefontal Dorsolateral/metabolismo , Femenino , Humanos , Masculino , Trastornos Mentales/terapia , Enfermedades del Sistema Nervioso/terapia , Lóbulo Parietal/metabolismo , Lóbulo Temporal/metabolismo , Estimulación Transcraneal de Corriente Directa/métodos , Estimulación Magnética Transcraneal/instrumentación , Estimulación Magnética Transcraneal/métodos , Ácido gamma-Aminobutírico/sangre
6.
Bull Exp Biol Med ; 171(3): 379-383, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34292446

RESUMEN

This article discusses the contribution of fMRI- and fMRI-EEG-neurofeedback into recovery of motor function in two subacute stroke patients during the early post-stroke period. Premotor and supplementary motor zones of the cortex were chosen as the targets of voluntary control. Patient 1 received 6 sessions of motor imagery-based fMRI neurofeedback of secondary motor areas activity and Patient 2 received a similar course with the addition of µ- and ß-EEG activity suppression. Both reduced the motor deficit severity, improved on the quality of life, and increased the C3/C4 coherence to other central leads within EEG µ-band. Patient 1 reliably increased the fMRI signal in target areas and improved on the strength and speed of hand movements. Patient 2 (fMRI-EEG) mastered the EEG activity regulation to a greater degree. The authors conclude that pure fMRI neurofeedback and bi-modal fMRI-EEG neurofeedback produce different clinical effects in motor rehabilitation, which confirms the prospect of the closed-loop stroke treatment.


Asunto(s)
Imágenes en Psicoterapia/métodos , Corteza Motora/fisiopatología , Neurorretroalimentación/métodos , Rehabilitación de Accidente Cerebrovascular/métodos , Accidente Cerebrovascular/terapia , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Electroencefalografía , Fuerza de la Mano/fisiología , Humanos , Imágenes en Psicoterapia/instrumentación , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Corteza Motora/diagnóstico por imagen , Neurorretroalimentación/instrumentación , Desempeño Psicomotor/fisiología , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/fisiopatología , Rehabilitación de Accidente Cerebrovascular/instrumentación , Estimulación Magnética Transcraneal/instrumentación , Estimulación Magnética Transcraneal/métodos , Resultado del Tratamiento
7.
Alzheimers Dement ; 16(4): 641-650, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31879235

RESUMEN

INTRODUCTION: This clinical trial evaluates the efficacy and safety of a 6-week course of daily neuroAD™ therapy. METHODS: 131 subjects between 60 and 90 years old, unmedicated for Alzheimer's disease (AD), or on stable doses of an acetylcholinesterase inhibitor and/or memantine, with Mini-Mental State Examination scores between 18 and 26, clinical dementia rating scale scores of 1 or 2, enrolled for a prospective, randomized, double-blind, sham-controlled, multicenter clinical trial. Structural brain MRIs were obtained for transcranial magnetic stimulation targeting. Baseline Alzheimer's disease assessment scale-cognitive (ADAS-Cog) and Clinical Global Impression of Change were assessed. 129 participants were randomized to active treatment plus standard of care (SOC) or sham treatments plus SOC. RESULTS: Subjects with baseline ADAS-Cog ≤ 30 (~85% of study population) showed a statistically significant benefit favoring active over sham. Responder analysis showed 31.7% participants in the active group with ≤ -4 point improvement on ADAS-Cog versus 15.4% in the sham group. DISCUSSION: neuroAD™ Therapy System provides a low-risk therapeutic benefit for patients with milder AD (baseline ADAS-Cog ≤30) beyond pharmacologic SOC.


Asunto(s)
Enfermedad de Alzheimer/terapia , Estimulación Magnética Transcraneal/instrumentación , Anciano , Anciano de 80 o más Años , Inhibidores de la Colinesterasa/uso terapéutico , Método Doble Ciego , Femenino , Humanos , Masculino , Memantina/uso terapéutico , Escala del Estado Mental , Persona de Mediana Edad , Estudios Prospectivos
8.
Neuromodulation ; 23(3): 324-334, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31353780

RESUMEN

BACKGROUND: Rodent models are fundamental in unraveling cellular and molecular mechanisms of transcranial magnetic stimulation (TMS)-induced effects on the brain. However, proper translation of human TMS protocols to animal models have been restricted by the lack of rodent-specific focal TMS coils. OBJECTIVE: We aimed to improve TMS focalization in rodent brain with a novel small, cooled, and rodent-specific TMS coil. METHODS: A rodent-specific 25-mm figure-of-eight TMS coil was developed. Stimulation focalization was simulated in silico for the rodent coil and a commercial human 50-mm figure-of-eight TMS coil. Both coils were also compared in vivo by electromyography measurements of brachialis motor evoked potential (MEP) responses to TMS at different brain sites in anesthetized rats (n = 6). Focalization was determined from the coils' level of stimulation laterality. Differences in MEPs were statistically analyzed with repeated-measures, within-subjects, ANOVA. RESULTS: In silico simulation results deemed the human coil insufficient for unilateral stimulation of the rat motor cortex, whereas lateralized electrical field induction was projected attainable with the rodent coil. Cortical, in vivo MEP amplitude measurements from multiple points in each hemisphere, revealed unilateral activation of the contralateral brachialis muscle, in absence of ipsilateral brachialis activation, with both coils. CONCLUSION: Computer simulations motivated the design of a smaller rodent-specific TMS coil, but came short in explaining the capability of a larger commercial human coil to induce unilateral MEPs in vivo. Lateralized TMS, as demonstrated for both TMS coils, corroborates their use in translational rodent studies, to elucidate mechanisms of action of therapeutic TMS protocols.


Asunto(s)
Simulación por Computador , Diseño de Equipo/métodos , Modelos Animales , Estimulación Magnética Transcraneal/instrumentación , Animales , Potenciales Evocados Motores/fisiología , Masculino , Ratas , Ratas Sprague-Dawley
9.
Neuromodulation ; 23(3): 384-392, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31645087

RESUMEN

OBJECTIVE: Insula neurocircuitry alterations are reported in a range of neuropsychiatric disorders holding promise for clinical interventions. We measured, in a pilot study, acute neuroplastic modulations resulting from high- and low-frequency stimulation with repetitive transcranial magnetic stimulation (rTMS) delivered via an H-coil that targeted the right insula and overlying prefrontal cortex. METHODS: Healthy, nonsmoking, adult participants (N = 28), in a within-participant, sham-controlled experiment, received a single rTMS session on four separate days. Participants received one session each of low- (1 Hz) and high (10 Hz)-frequency stimulation and two sessions of sham stimulation matched to each rTMS frequency. After each rTMS session, participants completed a functional magnetic resonance imaging (fMRI) scan while performing two cognitive tasks and a resting-state scan. The effect of rTMS was examined on task behavior as well as blood oxygenated level-dependent (BOLD) response during task performance and resting state. We expected low- and high-frequency stimulation to decrease and increase, respectively, insula and overlying cortical BOLD signal and network connectivity. RESULTS/CONCLUSIONS: There was no effect of rTMS, regardless of frequency, on task behavior or task-based BOLD response. There was an effect of rTMS compared to sham on rsFC between insula and medial prefrontal cortex, with connectivity reduced after rTMS compared to sham, regardless of frequency. Implications for using rTMS to the insula as a treatment for neuropsychiatric disorders are discussed in light of insula-medial prefrontal cortex connectivity.


Asunto(s)
Corteza Cerebral/fisiología , Vías Nerviosas/fisiología , Corteza Prefrontal/fisiología , Estimulación Magnética Transcraneal/instrumentación , Adulto , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Proyectos Piloto , Adulto Joven
10.
J Stroke Cerebrovasc Dis ; 29(6): 104816, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32321651

RESUMEN

BACKGROUND AND PURPOSE: Repetitive transcranial magnetic stimulation (rTMS) may promote recovery of motor function after stroke by inducing functional reorganization of cortical circuits. The objective of this study was to examine whether multifocal cortical stimulation using a new wearable transcranial rotating permanent magnet stimulator (TRPMS) can promote recovery of motor function after stroke by inducing functional reorganization of cortical circuits. METHODS: Thirty30 patients with chronic ischemic stroke and stable unilateral weakness were enrolled in a Phase 1/2a randomized double-blind sham-controlled clinical trial to evaluate safety and preliminary efficacy. Bilateral hemispheric stimulation was administered for 20 sessions 40 min each over 4 weeks. The primary efficacy endpoint was the change in functional MRI BOLD activation immediately after end of treatment. Secondary efficacy endpoints were clinical scales of motor function, including the Fugl-Meyer motor arm score, ARAT, grip strength, pinch strength, gait velocity, and NIHSS. RESULTS: TRPMS treatment was well-tolerated with no device-related adverse effects. Active treatment produced a significantly greater increase in the number of active voxels on fMRI than sham treatment (median +48.5 vs -30, p = 0.038). The median active voxel number after active treatment was 8.8-fold greater than after sham (227.5 vs 26, p = 0.016). Although the statistical power was inadequate to establish clinical endpoint benefits, numerical improvements were demonstrated in 5 of 6 clinical scales of motor function. The treatment effects persisted over a 3-month duration of follow-up. CONCLUSIONS: Multifocal bilateral TRPMS was safe and showed significant fMRI changes suggestive of functional reorganization of cortical circuits in patients with chronic ischemic stroke. A larger randomized clinical trial is warranted to verify recovery of motor function.


Asunto(s)
Isquemia Encefálica/terapia , Actividad Motora , Corteza Motora/fisiopatología , Accidente Cerebrovascular/terapia , Estimulación Magnética Transcraneal , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/fisiopatología , Enfermedad Crónica , Evaluación de la Discapacidad , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Corteza Motora/diagnóstico por imagen , Recuperación de la Función , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/fisiopatología , Texas , Factores de Tiempo , Estimulación Magnética Transcraneal/efectos adversos , Estimulación Magnética Transcraneal/instrumentación , Resultado del Tratamiento , Dispositivos Electrónicos Vestibles
11.
Neuroimage ; 203: 116194, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31525495

RESUMEN

Short-interval intracortical inhibition (SICI) has been studied with paired-pulse transcranial magnetic stimulation (TMS) by administering two pulses at a millisecond-scale interstimulus interval (ISI) to a single cortical target. It has, however, been difficult to study the interaction of nearby cortical targets with paired-pulse TMS. To overcome this limitation, we have developed a multi-locus TMS (mTMS) device, which allows controlling the stimulus location electronically. Here, we applied mTMS to study SICI in primary motor cortex with paired pulses targeted to adjacent locations, aiming to quantify the extent of the cortical region producing SICI in the location of a test stimulus. We varied the location and timing of the conditioning stimulus with respect to a test stimulus targeted to the cortical hotspot of the abductor pollicis brevis (APB) in order to study their effects on motor evoked potentials. We further applied a two-coil protocol with the conditioning stimulus given by an oval coil only to the surroundings of the APB hotspot, to which a subsequent test stimulus was administered with a figure-of-eight coil. The strongest SICI occurred at ISIs below 1 ms and at ISIs around 2.5 ms. These ISIs increased when the conditioning stimulus receded from the APB hotspot. Our two-coil paired-pulse TMS study suggests that SICI at ISIs of 0.5 and 2.5 ms originate from different mechanisms or neuronal elements.


Asunto(s)
Corteza Motora/fisiología , Inhibición Neural , Estimulación Magnética Transcraneal/instrumentación , Estimulación Magnética Transcraneal/métodos , Adulto , Potenciales Evocados Motores , Femenino , Humanos , Masculino , Adulto Joven
12.
BMC Psychiatry ; 19(1): 139, 2019 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-31064328

RESUMEN

BACKGROUND: The current study aims to systematically assess and compare the antidepressant outcomes of repetitive transcranial magnetic stimulation (rTMS) with the figure-of-eight (F8)-coil and deep transcranial magnetic stimulation (DTMS) with the H1-coil in studies matched on stimulation frequency in unipolar major depressive disorder (MDD). METHODS: Electronic search of Medline and PsycInfo identified 19 studies with stimulation frequency of 18-20 Hz using F8-coil (k = 8 randomised sham-controlled trials, RCTs, k = 3 open-label; n = 168 patients) or H1-coil (k = 1 RCT, k = 7 open-label; n = 200). Depression severity (the primary outcome) and response/remission rates (the secondary outcomes) were assessed at session 10. RESULTS: Effects pooled with random-effects meta-analysis showed a large reduction in depression severity, 29% response, and 15% remission rates after 10 sessions of active stimulation with either coil relative to baseline. Reduction in depression severity was greater in studies with younger patients using either coil. The comparison between coils showed a larger reduction in depression severity in H1-coil vs. F8-coil studies (independent of the study design or the concurrent pharmacotherapy) and a trend towards higher remission rates in F8-coil vs. H1-coils studies. These effects are based on a low volume of studies, are not controlled for placebo, and may not be clinically-relevant. The stimulation protocols differed systematically because stimulation was more focal but less intense (80-110% of the resting motor threshold, MT) in the F8-coil studies and less focal but more intense (120% MT) in the H1-coil studies. Two seizures occurred in the H1-coil studies relative to none in the F8-coil studies. CONCLUSION: When matched on frequency, the higher-intensity and less focal stimulation with the H1-coil reduces depression more than the lower-intensity and more focal stimulation with the F8-coil. Head-to-head trials should compare the antidepressant outcomes of F8-coil and H1-coil to identify the most optimal stimulation protocols for acute and longer-lasting efficacy.


Asunto(s)
Trastorno Depresivo Mayor/psicología , Trastorno Depresivo Mayor/terapia , Estimulación Magnética Transcraneal/instrumentación , Estimulación Magnética Transcraneal/métodos , Femenino , Humanos , Lenguaje , Masculino , Proyectos de Investigación , Retratamiento , Resultado del Tratamiento
13.
Neurosurg Focus ; 47(6): E10, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31786549

RESUMEN

Maximal safe resection is the modern goal for surgery of intrinsic brain tumors located in or close to brain eloquent areas. Nowadays different neuroimaging techniques provide important anatomical and functional information regarding the brain functional organization that can be used to plan a customized surgical strategy to preserve functional networks, and to increase the extent of tumor resection. Among these techniques, navigated transcranial magnetic stimulation (nTMS) has recently gained great favor among the neurosurgical community for preoperative mapping and planning prior to brain tumor surgery. It represents an advanced neuroimaging technique based on the neurophysiological mapping of the functional cortical brain organization. Moreover, it can be combined with other neuroimaging techniques such as diffusion tensor imaging tractography, thus providing a reliable reconstruction of brain eloquent networks. Consequently, nTMS mapping may provide reliable noninvasive brain functional mapping, anticipating information that otherwise may be available to neurosurgeons only in the operating theater by using direct electrical stimulation. The authors describe the reliability and usefulness of the preoperative nTMS-based approach in neurosurgical practice, and briefly discuss their experience using nTMS as well as currently available evidence in the literature supporting its clinical use. In particular, special attention is reserved for the discussion of the role of nTMS as a novel tool for the preoperative neurophysiological mapping of motor and language networks prior to surgery of intrinsic brain tumors located in or close to eloquent networks, as well as for future and promising applications of nTMS in neurosurgical practice.


Asunto(s)
Mapeo Encefálico/métodos , Neoplasias Encefálicas/diagnóstico por imagen , Glioma/diagnóstico por imagen , Neuronavegación/métodos , Cuidados Preoperatorios/métodos , Estimulación Magnética Transcraneal/métodos , Adulto , Anciano , Neoplasias Encefálicas/secundario , Neoplasias Encefálicas/cirugía , Imagen de Difusión Tensora/métodos , Potenciales Evocados Motores , Femenino , Glioma/cirugía , Humanos , Lenguaje , Masculino , Persona de Mediana Edad , Corteza Motora/diagnóstico por imagen , Habla/fisiología , Estimulación Magnética Transcraneal/instrumentación
14.
Neuromodulation ; 22(8): 867-870, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30506758

RESUMEN

INTRODUCTION: Approximately 15% of all people will experience a depressive episode throughout their lives, and by 2020, depression will be the second largest cause of disability around the world. Transcranial magnetic stimulation (TMS) has been shown to be an effective option for treating this condition. Devices such as the double-cone coil may bring new insights regarding depression treatment. METHODS: A literature search was performed on PubMed, ScienceDirect, Cochrane, LILACS, and Google Scholar by applying the descriptors "depression" AND "transcranial magnetic stimulation" AND "double cone-coil." RESULTS: Six studies were considered eligible (three clinical trials, two case series, and one isolated case report). All of them described treatments with transcranial magnetic stimulation by double-cone coil (DC-TMS) at 10 Hz over the dorsomedial prefrontal cortex, achieving response and remission rates of 40-52.4% and 34.7-47.6%, respectively. Two clinical trials investigated both intermittent theta-burst stimulation and 10 Hz TMS, suggesting a slight advantage of the latter. They also found no additional gains by combining both techniques. CONCLUSION: Despite the small number of controlled clinical trials and the small sample sizes, which limit the generalization of the obtained results, the collected data provide an optimistic perspective on the effectiveness of using DC-TMS for depression treatment.


Asunto(s)
Trastorno Depresivo/terapia , Estimulación Magnética Transcraneal/instrumentación , Estimulación Magnética Transcraneal/métodos , Ensayos Clínicos como Asunto , Trastorno Depresivo/psicología , Humanos , Resultado del Tratamiento
15.
Neuromodulation ; 22(8): 851-866, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30411429

RESUMEN

BACKGROUND: Repetitive transcranial magnetic stimulation (rTMS) has become increasingly popular during the last decades mainly driven by the antidepressant effects of dorsolateral prefrontal cortex stimulation with "butterfly" coils. Only recently, alternative targets such as the dorsomedial prefrontal cortex (dmPFC) have been brought into focus and innovative coil designs such as the angled geometry of the double cone coil (DCC) have raised hope to reach even deeper located targets. OBJECTIVE: To provide a systematic and comprehensive review on the application of rTMS stimulation of the dmPFC using the DCC in neuropathological and healthy samples. METHODS: We systematically searched the MEDLINE® database (http://www.ncbi.nlm.nih.gov/pubmed/). Due to the heterogeneous naming of DCC stimulation over the dmPFC a variety of search terms was applied resulting in a numeral quantity of 340 hits. RESULTS: DCC stimulation over the dmPFC has been proven to be safe and feasible in various neuropsychiatric disorders and in healthy subjects. Clinical results are encouraging, but have to be considered as preliminary as data from sham-controlled clinical trials and knowledge about the neurobiological underpinnings are still scarce. CONCLUSION: DCC stimulation over the dmPFC represents a promising approach in the fast evolving noninvasive brain stimulation techniques aiming at the functional modulation of brain areas vitally involved in affect, sensory autonomic, cognitive, and salience regulation. This may hold potential for both neuroscientific research and clinical applications in the treatment of psychiatric disorders.


Asunto(s)
Trastorno Depresivo/terapia , Corteza Prefrontal , Estimulación Magnética Transcraneal/métodos , Trastorno Depresivo/psicología , Humanos , Estimulación Magnética Transcraneal/instrumentación , Resultado del Tratamiento
16.
Magn Reson Med ; 79(1): 582-587, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28185321

RESUMEN

PURPOSE: To demonstrate the feasibility of turning transcranial magnetic stimulation (TMS) coil for MRI signal reception. METHODS: A critically coupled network was formed by using a resonated turn of TMS coil as the secondary and a regular radiofrequency (RF) coil as the primary. A third coil was positioned between the two coils for detuning during RF transmission. Bench measurement, numerical simulation, and MRI experiment were performed for validation. RESULTS: The signal-to-noise ratio of the proposed 2-in-1 coil is 35% higher in its field of view, compared with a MRI-only reference coil of the same size, made by the same material, and backed up by an untuned TMS coil, but lower than a RF surface coil of the same size without any TMS coil nearby. Spin-echo images of the human brain further validated its performance. CONCLUSIONS: The proposed method can transform TMS coil for MRI signal acquisition with virtually no modifications on the TMS side. It not only enables flexible and close positioning of TMS coil inside MRI scanner, but also improves the signal-to-noise ratio compared with conventional implementations. It can be applied as a building block for developing advanced concurrent TMS/MRI hardware. Magn Reson Med 79:582-587, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/instrumentación , Estimulación Magnética Transcraneal/instrumentación , Diseño de Equipo , Humanos , Modelos Teóricos , Fantasmas de Imagen , Ondas de Radio , Relación Señal-Ruido , Programas Informáticos
17.
Cerebellum ; 17(5): 540-549, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29730789

RESUMEN

Cerebellar brain inhibition (CBI) describes the inhibitory tone the cerebellum exerts on the primary motor cortex (M1). CBI can be indexed via a dual-coil transcranial magnetic stimulation protocol, whereby a conditioning stimulus (CS) is delivered to the cerebellum in advance of a test stimulus (TS) to M1. The CS is typically delivered at intensities over 60% maximum stimulus output (MSO) via a double-cone coil. This is reportedly uncomfortable for participants, reducing the reliability and validity of outcomes. This feasibility study investigates the reliability and tolerability of eliciting CBI across a range of CS intensities using both a double-cone and high-powered figure-of-8 coil, the D702. It was expected that the double-cone coil would elicit CBI at intensities upwards of 60%MSO. The range for the D702 coil was exploratory. The double-cone coil was expected to be less tolerable than the D702 coil. CBI was assessed in 13 participants (25.92 ± 5.42 years, six female) using each coil (randomized) over intensities 40, 50, 60, 70, 80%MSO. Tolerability was assessed via visual analog scales. Comparisons across intensities and tolerability were assessed non-parametrically and via a linear model. The double-cone coil elicited CBI at intensities 60, 70, and 80%MSO (p < .05), with suppression elicited at 60%MSO not significantly different to that at higher intensities. CBI was not reliably elicited by the D702 coil at any intensity. The double-cone coil was significantly less tolerable than the D702. A CS of 60%MSO with a double-cone coil provides a balance between the reliability and tolerability of CBI.


Asunto(s)
Cerebelo/fisiología , Inhibición Neural , Estimulación Magnética Transcraneal/instrumentación , Estimulación Magnética Transcraneal/métodos , Adulto , Electromiografía , Potenciales Evocados Motores/fisiología , Femenino , Humanos , Masculino , Corteza Motora/fisiología , Músculo Esquelético/fisiología , Inhibición Neural/fisiología , Vías Nerviosas/fisiología , Dolor/etiología , Reproducibilidad de los Resultados , Estimulación Magnética Transcraneal/efectos adversos
18.
J Neuropsychiatry Clin Neurosci ; 30(3): 242-245, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29366375

RESUMEN

Four transcranial magnetic stimulation (TMS) devices are currently approved for use in treatment-resistant depression. The authors present the first data-driven study examining the patient- and technician-experience using three of these distinct devices. A retrospective survey design with both patient and technician arms was utilized. The study population included patients who received TMS for treatment-resistant depression at the Berenson Allen Center for Noninvasive Brain Stimulation for the first time between 2013 and 2016 and technicians who worked in the program from 2009 to 2017. Statistical analysis included t tests and analyses of variance to assess differences between and across the multiple groups, respectively. Patients treated with the NeuroStar device reported greater confidence that the treatment was being performed correctly compared with those treated with the Magstim device. Conversely, with regard to tolerability, patients treated with the Magstim device reported less pain in the last week and less pain on average compared with those treated with the NeuroStar device. On average, technicians reported feeling that both the Magstim and NeuroStar devices were significantly easier to use than the Brainsway Deep TMS H-Coil device. Additionally, they found the former two devices to be more reliable and better tolerated. Furthermore, the technicians reported greater confidence in the Magstim and NeuroStar devices compared with the Brainsway Deep TMS H-Coil device and indicated that they would be more likely to recommend the two former devices to other treatment centers.


Asunto(s)
Actitud del Personal de Salud , Trastorno Depresivo Resistente al Tratamiento/psicología , Trastorno Depresivo Resistente al Tratamiento/terapia , Estimulación Magnética Transcraneal/psicología , Análisis de Varianza , Femenino , Conocimientos, Actitudes y Práctica en Salud , Humanos , Masculino , Estudios Retrospectivos , Estimulación Magnética Transcraneal/instrumentación , Cumplimiento y Adherencia al Tratamiento
19.
J Neuropsychiatry Clin Neurosci ; 30(3): 173-179, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29685065

RESUMEN

Noninvasive brain stimulation refers to a set of technologies and techniques with which to modulate the excitability of the brain via transcranial stimulation. Two major modalities of noninvasive brain stimulation are transcranial magnetic stimulation (TMS) and transcranial current stimulation. Six TMS devices now have approved uses by the U.S. Food and Drug Administration and are used in clinical practice: five for treating medication refractory depression and the sixth for presurgical mapping of motor and speech areas. Several large, multisite clinical trials are currently underway that aim to expand the number of clinical applications of noninvasive brain stimulation in a way that could affect multiple clinical specialties in the coming years, including psychiatry, neurology, pediatrics, neurosurgery, physical therapy, and physical medicine and rehabilitation. In this article, the authors review some of the anticipated challenges facing the incorporation of noninvasive brain stimulation into clinical practice. Specific topics include establishing efficacy, safety, economics, and education. In discussing these topics, the authors focus on the use of TMS in the treatment of medication refractory depression when possible, because this is the most widely accepted clinical indication for TMS to date. These challenges must be thoughtfully considered to realize the potential of noninvasive brain stimulation as an emerging specialty that aims to enhance the current ability to diagnose and treat disorders of the brain.


Asunto(s)
Estimulación Transcraneal de Corriente Directa , Estimulación Magnética Transcraneal , Encefalopatías/diagnóstico , Encefalopatías/terapia , Trastorno Depresivo/diagnóstico , Trastorno Depresivo/terapia , Humanos , Estimulación Transcraneal de Corriente Directa/efectos adversos , Estimulación Transcraneal de Corriente Directa/economía , Estimulación Transcraneal de Corriente Directa/instrumentación , Estimulación Transcraneal de Corriente Directa/métodos , Estimulación Magnética Transcraneal/efectos adversos , Estimulación Magnética Transcraneal/economía , Estimulación Magnética Transcraneal/instrumentación , Estimulación Magnética Transcraneal/métodos
20.
Epilepsy Behav ; 88S: 25-32, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30558717

RESUMEN

Epilepsy is often associated with comorbid psychiatric illnesses that can significantly impact its long-term course. The most frequent of these psychiatric comorbidities is major depressive disorder, which affects an estimated 40% of patients with epilepsy. Many patients are underdiagnosed or undertreated, yet managing their mood symptoms is critical to improving their outcomes. When conventional psychiatric treatments fail in the management of depression, neuromodulation techniques may offer promise, including electroconvulsive therapy (ECT), vagus nerve stimulation (VNS), and repetitive transcranial magnetic stimulation (rTMS), as discussed in this review. "This article is part of the Supplement issue Neurostimulation for Epilepsy."


Asunto(s)
Trastorno Depresivo Mayor/terapia , Epilepsia Refractaria/terapia , Terapia Electroconvulsiva/métodos , Neuroestimuladores Implantables , Ensayos Clínicos como Asunto/métodos , Trastorno Depresivo Mayor/epidemiología , Trastorno Depresivo Mayor/psicología , Epilepsia Refractaria/epidemiología , Epilepsia Refractaria/psicología , Terapia Electroconvulsiva/instrumentación , Humanos , Psicoterapia/instrumentación , Psicoterapia/métodos , Estimulación Magnética Transcraneal/instrumentación , Estimulación Magnética Transcraneal/métodos , Estimulación del Nervio Vago/instrumentación , Estimulación del Nervio Vago/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA