Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 981
Filtrar
1.
J Sep Sci ; 45(1): 172-184, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34453482

RESUMEN

The separation and purification of biomacromolecules such as nucleic acid is a perpetual topic in separation processes and bioengineering (fine chemicals, biopharmaceutical engineering, diagnostics, and biological characterization). In principle, the solid-phase extraction for nucleic acid exhibits efficient phase separation, low pollution risk, and small sample demand, compared to the conventional liquid-phase extraction. Herein, solid-phase extraction methods are systematically reviewed to outline research progress and explore additional solid-phase sorbents and devices for novel, flexible, and high-efficiency nucleic acid separation processes. The functional materials capture nucleic acid, magnetic and magnetic-free solid-phase extraction methods, separation device design and optimization, and high-throughput automatable applications based on high-performance solid-phase extraction are summarized. Finally, the current challenges and promising topics are discussed.


Asunto(s)
Ácidos Nucleicos/aislamiento & purificación , Extracción en Fase Sólida/métodos , Adsorción , Magnetismo/instrumentación , Magnetismo/métodos , Ácidos Nucleicos/genética , Extracción en Fase Sólida/instrumentación
2.
J Sep Sci ; 45(1): 149-165, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34347938

RESUMEN

In multiresidue analysis, the QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) is one of the most popular techniques routinely used by researchers during pesticide analysis of food and vegetable samples. Originally, the QuEChERS method was developed for analysis of pesticide residues from fruits and vegetables, but rapidly gained popularity in the extraction of analytes from different matrices. This analytical approach shows several advantages over traditional extraction techniques: it requires lower sample and solvent amounts while shortening the time of sample preparation. However, it presents some limitations for complex matrices such as those containing high amounts of chlorophyll. To overcome the problem of strong matrix effect and influence of interferences, different approaches are applied. Most are concerning modifications of the cleanup step, that is, sorbent type and its amount. Optimization of other parameters, such as sample size, hydration level, extraction solvent, and buffering, also has an impact on overall performance. Combining proper sample preparation with modern highly sensitive and selective detection techniques enables receiving desired limits of quantification. This article presents an overview of strategies employed by researchers for analysis of green, high chlorophyll content commodities and results obtained in their studies.


Asunto(s)
Clorofila/análisis , Análisis de los Alimentos/métodos , Contaminación de Alimentos/análisis , Residuos de Plaguicidas/análisis , Residuos de Plaguicidas/aislamiento & purificación , Extracción en Fase Sólida/métodos , Análisis de los Alimentos/economía , Contaminación de Alimentos/economía , Extracción en Fase Sólida/economía , Extracción en Fase Sólida/instrumentación
3.
J Sci Food Agric ; 102(3): 995-1001, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34302362

RESUMEN

BACKGROUND: Recently, methods have been developed for the better quality control, fraud detection and analytical investigation of olive oil. Magnetic graphene oxide (GO) material is known for its reusability, high adsorption capability and stability in food sample preparation. Monopalmitine or 2-glycerol monopalmitate (2-GMP) is one of the main parameters in the quality assay and classification of olive oil, which can be classified as extra virgin ≤ 0.9% and olive pomace ≤ 1.2. Hence, newly synthesized magnetic GO (MGO) and commercial silica-gel were used as a dispersive solid-phase clean-up (d-SPE) sorbent to determine 2-GMP value in olive oil samples prior to gas chromatography (GC) analysis. The d-SPE method is validated with olive oil certified reference material (CRM) with respect to silica-gel and a MGO nanocomposite. RESULTS: The developed d-SPE method was applied for various virgin, refined and pomace olive oil samples to determine the value of 2-GMP%. The presence of 2-GMP in the samples was confirmed by GC-mass spectrometry analysis based on silylation derivatives of the analyte. Finally, the d-SPE-MGO method was determined 2-GMP% as 1.9% for pomace olive oil, 0.6% for refined olive oil, 0.4% for virgin olive oil and 3.1% for CRM. The MGO provided satisfactory clean-up recovery (124%) in the acceptable data range for CRM2018, and silica-gel also provided satisfactory recovery (83%) for CRM2018. The proposed method performed with higher sensitivity and efficiency for screening 2-GMP% in olive oil. CONCLUSION: The MGO based d-SPE method was applied for clean-up purposes to determine 2-GMP%. It proved superior via its advantageous features of super quickness, easy isolation with an external magnet and the highly efficient exclusion of all the coexisting interfering peaks conventionally generated with a standard silica-gel material. These methods based on MGO and silica-gel are reflected in the dispersive mode of extraction and can be used as alternatives to conventional methods. Considering the benefits of the consumption of significantly fewer sorbents and less time required regarding the dispersive methods, the methods can be utilized as alternatives in contrast to conventional techniques. © 2021 Society of Chemical Industry.


Asunto(s)
Grafito/química , Nanocompuestos/química , Aceite de Oliva/química , Palmitatos/química , Extracción en Fase Sólida/métodos , Adsorción , Cromatografía de Gases y Espectrometría de Masas , Gel de Sílice/química , Extracción en Fase Sólida/instrumentación
4.
J Chem Ecol ; 47(12): 930-940, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34415499

RESUMEN

Complex inter-organismal communication among plants, insects, and microbes in natural and agricultural ecological systems is typically governed by emitted and perceived semiochemicals. To understand and ultimately utilize the role of volatile semiochemicals in these interactions, headspace volatiles are routinely collected and analyzed. Numerous collection systems are available (e.g., static or dynamic; adsorption or absorption) where the choice of technique should be dependent upon the plant, insect, or microbial ecological system studied, the information sought, and the limitations of each method. Within these constraints, it remains necessary that each method detects and provides the accurate in situ, or in vitro, volatile profile of the studied system. Herein, we analyzed and compared the pros and cons of three solventless, thermal desorption systems (SPME, Tenax/cold trap, SPDE) using a synthetic standard blend of compounds mimicking a simple natural blend (benzaldehyde, b-caryophyllene, (Z)-3-hexenol, 6-methyl-5-hepten-2-one, and limonene). Direct splitless injection and Super Q collections of the standard blend were used as controls. The results indicated that related qualitative, as well as quantitative differences, could be correlated with adsorbent sampling capacity and structural bias. The results for Tenax/cold trap and SPDE also were affected by sampled headspace volumes. All solventless techniques exhibited high analytical reproducibility, with SPME and SPDE providing ease of use, low cost, and minimal instrument modifications. The more complex Tenax/cold trap technique provided higher collection efficiency. Using these results, we provide guidance for technique selection for chemical communication applications.


Asunto(s)
Extracción en Fase Sólida/métodos , Manejo de Especímenes/métodos , Compuestos Orgánicos Volátiles/análisis , Reproducibilidad de los Resultados , Extracción en Fase Sólida/instrumentación , Manejo de Especímenes/instrumentación
5.
J Sep Sci ; 44(10): 2143-2152, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33734567

RESUMEN

In this work, a magnetic graphene material coated with mesoporous silica was selected as the substrate, 3-glycidoxypropyltrimethoxysilane and polyethyleneimine were sequentially bonded through chemical reactions, and then carrageenan was successfully introduced by electrostatic interaction; finally, hydrophilic nanocomposite material was prepared. Due to the large number of hydrophilic groups, and polyethyleneimine was connected by means of chemical bonds, this material exhibits good hydrophilicity and stability for glycopeptide enrichment. In the actual enrichment process, nanomaterial exhibits high selectivity (1:500), high sensitivity (2 fmol), and good repeatability (five cycles). In addition, the synthesized material also shows a good enrichment effect in the face of actual complex biological samples, which captured 40 N-glycopeptides from human saliva, indicating the application potential for enrichment of N-glycopeptides.


Asunto(s)
Carbono/química , Carragenina/química , Glicopéptidos/aislamiento & purificación , Polietileneimina/química , Saliva/química , Silanos/química , Extracción en Fase Sólida/métodos , Glicopéptidos/análisis , Grafito/química , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Magnetismo , Nanocompuestos , Nanoestructuras/química , Extracción en Fase Sólida/instrumentación , Electricidad Estática
6.
J Sep Sci ; 44(10): 2121-2130, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33720499

RESUMEN

In this study, a new floating dispersive solid phase extraction method based on deep eutectic solvents has been developed in a home-made extraction device for the extraction of four tetracycline antibiotics from milk samples. In this approach, the sorbent (activated carbon) was dispersed in whole parts of solution with the aid of air stream and floated on top of the solution with the aid of the surfactant (lauryl betaine) and air bubbles. After collection of the sorbent, the adsorbed analytes were eluted with tetrabutyl ammonium chloride-propionic acid deep eutectic solvent under sonication. In this method, there was no need of organic dispersive and extraction solvents and the used sorbent was collected on top of the solution and collected without centrifugation. The validation parameters showed that low limits of detection (0.1-0.3 µg/kg) and quantification (0.6-1.0 µg/kg), acceptable enrichment factors (52-60), efficient extraction recoveries (80-91%), and satisfactory relative standard deviations (≤9.8%) were obtained. Eventually, the method was successfully applied on different milk samples and tetracycline was determined in them.


Asunto(s)
Antibacterianos/aislamiento & purificación , Residuos de Medicamentos/aislamiento & purificación , Leche/química , Extracción en Fase Sólida/métodos , Tetraciclinas/aislamiento & purificación , Adsorción , Animales , Antibacterianos/análisis , Bovinos , Residuos de Medicamentos/análisis , Contaminación de Alimentos/análisis , Límite de Detección , Extracción en Fase Sólida/instrumentación , Solventes , Tensoactivos/química , Tetraciclinas/química
7.
J Sep Sci ; 44(10): 2131-2142, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33721391

RESUMEN

In this work, a green strategy was developed to prepare molecularly imprinted polymers functionalized magnetic carbon nanotubes in aqueous phase under mild conditions for cyclic adenosine monophosphate. Thanks to water solubility of chitosan, a natural polysaccharide which is rich in amino and hydroxyl groups, provided the feasibility to synthesize the green molecularly imprinted polymers for water soluble template in aqueous media. Coupled with high-performance liquid chromatography, the method exhibited a short equilibrium time (6 min), high adsorption capacity (22.42 µg/mg), high magnetic susceptibility, and good selectivity to template molecule with the imprinting factor of 2.94. A good linearity in the range of 0.020-3.0 mg/mL for target was obtained with a correlation coefficient of 0.9998. The limit of detection (signal-to-noise ratio = 3) and limit of quantitation (signal-to-noise ratio = 10) of the magnetic solid phase extraction method for cyclic adenosine monophosphate were 5 and 15 ng/mg, respectively. And the practical application of chitosan-based molecularly imprinted polymers as adsorbent to isolate and determine cyclic adenosine monophosphate in real natural samples (winter jujube) was demonstrated.


Asunto(s)
Adenosina Monofosfato/aislamiento & purificación , Magnetismo/métodos , Polímeros Impresos Molecularmente/química , Extractos Vegetales/aislamiento & purificación , Extracción en Fase Sólida/métodos , Ziziphus/química , Adenosina Monofosfato/análisis , Adsorción , Cromatografía Líquida de Alta Presión , Frutas/química , Interacciones Hidrofóbicas e Hidrofílicas , Magnetismo/instrumentación , Impresión Molecular , Polímeros Impresos Molecularmente/síntesis química , Nanotubos de Carbono/química , Extractos Vegetales/análisis , Extracción en Fase Sólida/instrumentación
8.
Mikrochim Acta ; 188(6): 189, 2021 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-33991231

RESUMEN

There are a lot of review papers of sample pretreatment, but the comprehensive review on pipette-tip solid-phase extraction (PT-SPE) is lacking. This review (133 references) is mainly devoted to the development of different types of micro- and nanosorbent-based PT-SPE, including silica materials, carbon materials, organic polymers, molecularly imprinted polymers, and metal-organic frameworks. Each section mainly introduces and discusses the preparation methods, advantages and limitations of adsorbents, and their applications to environmental, biological, and food samples. This review also demonstrates the advantages of PT-SPE like convenience, speed, less organic solvent, and low cost. Finally, the future application and development trend of PT-SPE are prospected.


Asunto(s)
Nanotubos de Carbono/química , Extracción en Fase Sólida/métodos , Adsorción , Animales , Grafito/química , Humanos , Estructuras Metalorgánicas/química , Polímeros Impresos Molecularmente/química , Dióxido de Silicio/química , Extracción en Fase Sólida/instrumentación
9.
Int J Mol Sci ; 22(16)2021 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-34445079

RESUMEN

Solid-phase extraction (SPE) coupled to LC/MS/MS analysis is a valid approach for the determination of organic micropollutants (OMPs) in liquid samples. To remove the greatest number of OMPs from environmental matrices, the development of innovative sorbent materials is crucial. Recently, much attention has been paid to inorganic nanosystems such as graphite-derived materials. Graphene oxide has been employed in water-purification processes, including the removal of several micropollutants such as dyes, flame retardants, or pharmaceutical products. Polysaccharides have also been widely used as convenient media for the dispersion of sorbent materials, thanks to their unique properties such as biodegradability, biocompatibility, nontoxicity, and low cost. In this work, chitosan-graphene oxide (CS_GO) composite membranes containing different amounts of GO were prepared and used as sorbents for the SPE of pesticides. To improve their dimensional stability in aqueous medium, the CS_GO membranes were surface crosslinked with glutaraldehyde. The composite systems were characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, thermogravimetric analysis, swelling degree, contact angle, and mechanical measurements. As the GO content increased, a decrease in surface homogeneity, an improvement of mechanical properties, and a reduction of thermal stability of the CS-based membranes were observed. The increased dimensional stability in water, together with the presence of high GO amounts, made the prepared composite membranes more efficacious than the ones based just on CS in isolating and preconcentrating different hydrophilic/hydrophobic pollutants.


Asunto(s)
Quitosano/química , Grafito/química , Membranas Artificiales , Plaguicidas/aislamiento & purificación , Extracción en Fase Sólida/instrumentación , Contaminantes Químicos del Agua/aislamiento & purificación , Cromatografía Líquida de Alta Presión , Plaguicidas/análisis , Extracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem , Agua/análisis , Contaminantes Químicos del Agua/análisis
10.
Molecules ; 26(14)2021 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-34299560

RESUMEN

Environmental pollutants, such as mycotoxins, pesticides, and pharmaceuticals, are a group of contaminates that occur naturally, while others are produced from anthropogenic sources. With increased research on the adverse ecological and human health effects of these pollutants, there is an increasing need to regularly monitor their levels in food and the environment in order to ensure food safety and public health. The application of magnetic nanomaterials in the analyses of these pollutants could be promising and offers numerous advantages relative to conventional techniques. Due to their ability for the selective adsorption, and ease of separation as a result of magnetic susceptibility, surface modification, stability, cost-effectiveness, availability, and biodegradability, these unique magnetic nanomaterials exhibit great achievement in the improvement of the extraction of different analytes in food. On the other hand, conventional methods involve longer extraction procedures and utilize large quantities of environmentally unfriendly organic solvents. This review centers its attention on current applications of magnetic nanomaterials and their modifications in the extraction of pollutants in food commodities.


Asunto(s)
Imanes/química , Micotoxinas/aislamiento & purificación , Nanoestructuras/química , Plaguicidas/aislamiento & purificación , Preparaciones Farmacéuticas/aislamiento & purificación , Extracción en Fase Sólida/métodos , Animales , Contaminantes Ambientales/análisis , Contaminantes Ambientales/aislamiento & purificación , Contaminación de Alimentos/análisis , Inocuidad de los Alimentos , Humanos , Micotoxinas/análisis , Plaguicidas/análisis , Preparaciones Farmacéuticas/análisis , Extracción en Fase Sólida/instrumentación
11.
J Sci Food Agric ; 101(5): 1767-1771, 2021 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-32888337

RESUMEN

BACKGROUND: Patulin is a mycotoxin that mainly contaminates apple juice, which is a typical high sugar matrix. Many different adsorbents have been utilized to develop a sample pretreatment method to minimize the matrix interference from apple juice. RESULTS: A simple and reliable extraction method for the determination of patulin in apple juice has been developed. The sample preparation involves a simple one-step cleanup procedure using amine-functionalized polymeric solid-phase extraction cartridges (Retain AX) that effectively remove interferences and facilitate the quantification. Isotope dilution liquid chromatography tandem mass spectrometry (ID-LC-MS/MS) was employed to minimize the matrix effect and ensure reliable results. The limit of detection was as low as 0.2 µg kg-1 , which was satisfactory with regard to current European, US, and Chinese legislation. Matrix-matched linearity (r2 = 0.9997) was established in the range of 1-400 µg kg-1 . Recovery was performed in samples spiked at three levels, and results were between 97.2% and 100.2%. CONCLUSION: The results indicated that, with one-step cleanup, the matrix effect was negligible and sensitivity was satisfactory. Our work provided a simple and reliable method for patulin detection in apple juice and is also very promising in routine quality control. © 2020 Society of Chemical Industry.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Jugos de Frutas y Vegetales/análisis , Malus/química , Patulina/análisis , Patulina/aislamiento & purificación , Extracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/métodos , Aminas/química , Contaminación de Alimentos/análisis , Frutas/química , Extracción en Fase Sólida/instrumentación
12.
J Sci Food Agric ; 101(4): 1666-1675, 2021 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-32888325

RESUMEN

BACKGROUND: Endocrine disrupting chemicals (EDCs), proved to be potential carcinogenic threats to human health, have received great concerns in food field. It was essential to develop effective methods to detect EDCs in food samples. The present study proposed an efficient method to determine trace EDCs including estrone (E1), 17ß-estradiol (E2), estriol (E3) and bisphenol A (BPA) based on magnetic solid-phase extraction (MSPE) coupled high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) in meat samples. RESULTS: Fe3 O4 @COF(TpBD)/TiO2 nanocomposites were synthesized via functionalization of magnetic covalent organic frameworks (COFs) with titanium dioxide (TiO2 ) nanoparticles, and used as absorbents of MSPE to enrich EDCs. The efficient EDCs enrichment relies on π-π stacking interaction, hydrogen bonding, and the interaction between titanium ions (IV, Ti4+ ) and hydroxyl groups in EDCs, which improves the selectivity and sensitivity. Under the optimized conditions, target EDCs were rapidly extracted through MSPE with 5 min. Combining Fe3 O4 @COF(TpBD)/TiO2 based MSPE and HPLC-MS/MS to determine EDCs, good linearities were observed with correlation coefficient (R2 ) ≥ 0.9989. The limits of detection (LODs) and limits of quantification (LOQs) were 0.13-0.41 µg kg-1 and 0.66-1.49 µg kg-1 , respectively. Moreover, the proposed method was successfully applied to real samples analysis. CONCLUSIONS: The established MSPE-HPLC-MS/MS method was successfully applied to determine EDCs in meat samples with rapidness, improved selectivity and sensitivity. It shows great prospects for EDCs detection in other complicated matrices. © 2020 Society of Chemical Industry.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Disruptores Endocrinos/análisis , Disruptores Endocrinos/aislamiento & purificación , Contaminación de Alimentos/análisis , Extracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/métodos , Compuestos de Bencidrilo/análisis , Compuestos de Bencidrilo/aislamiento & purificación , Estradiol/análisis , Estradiol/aislamiento & purificación , Estriol/análisis , Estriol/aislamiento & purificación , Estrona/análisis , Estrona/aislamiento & purificación , Límite de Detección , Fenoles/análisis , Fenoles/aislamiento & purificación , Extracción en Fase Sólida/instrumentación
13.
Anal Chem ; 92(16): 11232-11241, 2020 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-32662265

RESUMEN

The application of Pb isotopes to marine geochemistry is currently hindered by challenges associated with the analysis of Pb isotopes in seawater. The current study evaluates the performance of multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements of seawater Pb isotope compositions following Pb separation by either solid-phase extraction with Nobias Chelate PA-1 resin or coprecipitation with Mg(OH)2 and using either a Pb double spike or external normalization to Tl for mass bias correction. The four analytical combinations achieve results of similar quality when measuring 1-7 ng of seawater Pb, with reproducibilities (two standard deviations, 2SD) of 100-1200 ppm for 206Pb/207Pb and 208Pb/207Pb and 300-1700 ppm for ratios involving the minor 204Pb isotope. All four procedures enable significantly improved sample throughput compared to an established thermal ionization mass spectrometry (TIMS) double-spike method and produce unbiased seawater Pb isotope compositions with similar or improved precision. Nobias extraction is preferable to coprecipitation due to its greater analytical throughput and suitability for analyses of large seawater samples with high Si(OH)4 contents. The most accurate Pb isotope data are produced following Nobias extraction and double-spike correction as such analyses are least susceptible to matrix effects. However, Nobias extraction with Tl normalization constitutes an attractive alternative as, unlike the double-spike procedure, only a single mass spectrometric measurement is required, which improves analytical throughput and optimizes Pb consumption for analysis. Despite the advantages of solid-phase extraction, coprecipitation represents a useful Pb separation technique for samples with low to moderate Si contents as it is inexpensive, simple to implement, and the data are only marginally less accurate, especially when combined with a Pb double spike for mass bias correction.


Asunto(s)
Isótopos/análisis , Plomo/análisis , Agua de Mar/análisis , Isótopos/aislamiento & purificación , Plomo/aislamiento & purificación , Hidróxido de Magnesio/química , Espectrometría de Masas/métodos , Extracción en Fase Sólida/instrumentación , Extracción en Fase Sólida/métodos
14.
Anal Chem ; 92(1): 859-866, 2020 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-31790196

RESUMEN

Neuropeptide Y (NPY) is a 36-amino acid peptide circulating at a subpicomolar concentration participating in multiple physiological and pathological processes. NPY is prone to peptidolysis, generating metabolites with modified affinity for the five known receptors of NPY that mediate distinct effects. It is, therefore, crucial to distinguish each metabolite to understand the multiple functions of NPY. Since immunoassays are not able to distinguish NPY from its metabolites, we have validated a microliquid chromatography tandem mass spectrometry (micro-LC-MS/MS) assay for the quantification of endogenous NPY, NPY2-36, NPY3-36, NPY1-35, and NPY3-35 in human plasma. Sample preparation relies on immunoextraction in 96-well plates, followed by solid-phase extraction prior to micro-LC-MS/MS. The LLOQ ranged from 0.03 to 0.16 pM, intra- and inter-assay precision were <27% and trueness <22%. We determined reference intervals in 155 healthy volunteers and 40 hypertensive patients. We found that NPY3-36 is the main circulating peptide in resting conditions and that NPY and catecholamines are simultaneously increased during orthostasis. We also showed that the concentrations of NPY and its metabolites are similar in healthy volunteers and hypertensive patients. NPY is the prototype peptide that circulates in concentrations expected to be beyond instrumental capacities. We have been successful in developing a high-throughput specific and sensitive assay by including a deep knowledge of the physicochemical properties of these peptides to an efficient multistep sample preparation, and a micro-LC chromatography. We believe that our methodological approach opens the possibility to selectively quantify other endogenous peptides cleaved by peptidases whose concentrations are below 1 pM.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Neuropéptido Y/sangre , Espectrometría de Masas en Tándem/métodos , Anticuerpos Inmovilizados/química , Cromatografía Líquida de Alta Presión/instrumentación , Diseño de Equipo , Humanos , Límite de Detección , Neuropéptido Y/análisis , Neuropéptido Y/metabolismo , Extracción en Fase Sólida/instrumentación , Extracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/instrumentación
15.
Biomed Microdevices ; 22(3): 44, 2020 06 22.
Artículo en Inglés | MEDLINE | ID: mdl-32572586

RESUMEN

We present a disposable polymeric microfluidic device capable of reversibly binding and purifying Salmonella DNA through solid phase extraction (SPE). The microfluidic channels are first oxygen plasma treated and simultaneously micro-nanotextured, and then functionalized with amine groups via modification with L-histidine or poly-L-histidine. L-Histidine and poly-L-histidine bind on the plasma treated chip surface, and are not detached when rinsing with DNA purification protocol buffers. A pH-dependent protocol is applied on-chip to purify Salmonella DNA, which is first bound on the protonated amines at a pH (5.0) lower than their pKa of surface amine-groups which is 6.0 and then released at a pH higher than the pKa value (10.5). It was found that modification with poly-L-histidine resulted in higher surface density of amine groups onto microfluidic channel. Using the chip modified with poly-L-histidine, high recovery efficiency of at least 550 ng of isolated Salmonella DNA as well as DNA purification from Salmonella cell lysates corresponding to less than 5000 cells or 0.026 ng of Salmonella DNA was achieved. The protocol developed does not require ethanol or chaotropic solutions typically used in DNA purification, which are known inhibitors for downstream operations such as polymerase chain reactions (PCR) and which can also attack some polymeric microfluidic materials. Therefore, the microfluidic device and the related protocol hold promise for facile incorporation in microfluidics and Lab-on-a-chip (LOC) platforms for pathogen detection or in general for DNA purification.


Asunto(s)
ADN Bacteriano/aislamiento & purificación , Histidina/química , Dispositivos Laboratorio en un Chip , Extracción en Fase Sólida/instrumentación , Aminas/química , ADN Bacteriano/química , Salmonella/citología , Salmonella/genética
16.
Anal Bioanal Chem ; 412(2): 473-480, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31792597

RESUMEN

A phenyl-based polymer monolithic column was prepared via free radical polymerization in a stainless steel column with the size of 4.6 mm i.d. × 50 mm, using ethylene glycol phenyl ether acrylate as the monomer. The resulting monolithic column shows high porosity of 73.42% and relative uniform pore structure, as characterized by mercury porosimetry and scanning electron microscopy, respectively. The optimized polymer monolith column was used for on-line solid-phase extraction prior to the reversed phase mode HPLC-UV analysis for the determination of dioscin in human plasma, using a COSMOSIL C18 column (4.6 mm × 150 mm, 4.5 µm). Water was used to wash non-retained components from the SPE sorbent, and methanol water (80:20, V/V) was used as the mobile phase for isocratic elution of dioscin. The maximum adsorbed quantity of dioscin to the SPE column is 6.79 mg/g, which is high enough for the quantitative analysis of dioscin in plasma, due to the low content of dioscin in plasma. The method was validated by assessing the linearity, lower limit of quantification, intra- and inter-day precision, accuracy, and repeatability. The developed method was applied for the analysis of dioscin in plasma from a volunteer who had orally administered an aqueous extract of dioscorea nipponica rhizome, showing the method capable of detecting dioscin in the plasma. These results show that the developed method is a rapid method for on-line solid-phase extraction and determination of dioscin from plasma, exhibiting good selectivity with hydrogen bond interaction and hydrophobic interaction, good clean-up ability, cost-saving, and time-saving. Graphical abstract.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Diosgenina/análogos & derivados , Extracción en Fase Sólida/métodos , Diosgenina/sangre , Diosgenina/normas , Humanos , Límite de Detección , Estándares de Referencia , Reproducibilidad de los Resultados , Extracción en Fase Sólida/instrumentación
17.
Anal Bioanal Chem ; 412(1): 129-138, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31773230

RESUMEN

A novel lab-on-chip integrated microfluidic device for solid-phase extraction (SPE) and spectrophotometric detection of morphine (MOR), codeine (COD), and papaverine (PAP) was developed. The extracted analytes were analyzed with a miniature UV-Vis spectrophotometer. The SPE adsorptive phase composed of polyurethane/polyaniline (PU/PANI) nanofibers was fabricated by electrospinning and in situ oxidative polymerization techniques. The sorbent was characterized by Fourier transform infrared (FTIR) spectroscopy and scanning electron microscopy (SEM). The main factors of extraction such as desorption conditions, pH, salt effect, and extraction time were investigated. The partial least square (PLS) regression was applied to improve the quantification of analytes. The linear dynamic ranges (LDRs) for MOR, COD, and PAP were 4-240, 4-210, and 1-150 ng mL-1, respectively. Finally, the proposed method was successfully applied for the determination of MOR, COD, and PAP in human urine samples and the extraction recoveries were obtained in the range of 66.7-85.0% with RSDs < 8.3%.


Asunto(s)
Codeína/orina , Dispositivos Laboratorio en un Chip , Morfina/orina , Papaverina/orina , Extracción en Fase Sólida/instrumentación , Espectrofotometría Ultravioleta/métodos , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Humanos , Microscopía Electrónica de Rastreo , Reproducibilidad de los Resultados
18.
Anal Bioanal Chem ; 412(19): 4713-4724, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32468278

RESUMEN

Exosomes, a subset of the extracellular vesicle (EV) group of organelles, hold great potential for biomarker detection, therapeutics, disease diagnosis, and personalized medicine applications. The promise and potential of these applications are hindered by the lack of an efficient means of isolation, characterization, and quantitation. Current methods for exosome and EV isolation (including ultracentrifugation, microfiltration, and affinity-based techniques) result in impure recoveries with regard to remnant matrix species (e.g., proteins, genetic material) and are performed on clinically irrelevant time and volume scales. To address these issues, a polyethylene terephthalate (PET) capillary-channeled polymer (C-CP) fiber stationary phase is employed for the solid-phase extraction (SPE) of EVs from various matrices using a micropipette tip-based format. The hydrophobic interaction chromatography (HIC) processing and a spin-down workflow are carried out using a table-top centrifuge. Capture and subsequent elution of intact, biologically active exosomes are verified via electron microscopy and bioassays. The performance of this method was evaluated by capture and elution of exosome standards from buffer solution and three biologically relevant matrices: mock urine, reconstituted non-fat milk, and exosome-depleted fetal bovine serum (FBS). Recoveries were evaluated using UV-Vis absorbance spectrophotometry and ELISA assay. The dynamic binding capacity (50%) for the 1-cm-long (~ 5 µL bed volume) tips was determined using a commercial exosome product, yielding a value of ~ 7 × 1011 particles. The novel C-CP fiber spin-down tip approach holds promise for the isolation of exosomes and other EVs from various matrices with high throughput, low cost, and high efficiency. Graphical abstract.


Asunto(s)
Exosomas/química , Poliésteres/química , Extracción en Fase Sólida/métodos , Animales , Bovinos , Diseño de Equipo , Humanos , Leche/química , Tereftalatos Polietilenos/química , Suero/química , Extracción en Fase Sólida/instrumentación , Orina/química
19.
J Sep Sci ; 43(15): 3146-3163, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32573988

RESUMEN

The structural information and spatial distribution of molecules in biological tissues are closely related to the potential molecular mechanisms of disease origin, transfer, and classification. Ambient ionization mass spectrometry imaging is an effective tool that provides molecular images while describing in situ information of biomolecules in complex samples, in which ionization occurs at atmospheric pressure with the samples being analyzed in the native state. Ambient ionization mass spectrometry imaging can directly analyze tissue samples at a fairly high resolution to obtain molecules in situ information on the tissue surface to identify pathological features associated with a disease, resulting in the wide applications in pharmacy, food science, botanical research, and especially clinical research. Herein, novel ambient ionization techniques, such as techniques based on spray and solid-liquid extraction, techniques based on plasma desorption, techniques based on laser desorption ablation, and techniques based on acoustic desorption were introduced, and the data processing of ambient ionization mass spectrometry imaging was briefly reviewed. Besides, we also highlight recent applications of this imaging technology in clinical researches and discuss the challenges in this imaging technology and the perspectives on the future of the clinical research.


Asunto(s)
Investigación Biomédica , Enfermedad , Proyectos de Investigación , Presión Atmosférica , Pruebas Diagnósticas de Rutina/instrumentación , Humanos , Extracción Líquido-Líquido/instrumentación , Pronóstico , Extracción en Fase Sólida/instrumentación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación
20.
J Sep Sci ; 43(4): 774-781, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31742883

RESUMEN

A simple method for the determination of phenolic acids in Chinese Wolfberry drink based on polyethyleneimine modified porous aromatic framework and graphene oxide composite sorbent for pipette-tip solid-phase extraction was developed. Porous aromatic framework and raphene oxide composite materials were grafted by silane coupling agent (3-Chloropropyl)-trimethoxysilane. The modified materials were characterized by five kinds of characterization. Experimental results showed that the prepared p-phenylenediamine, cyanuric chloride, and graphene oxide composite material had a loose structure combined with the framework which improved hydrophobicity, and polyethyleneimine to increase the selectivity with the targets. The parameters of the pipette-tip solid-phase extraction procedure including the amount of sorbents, volumes and types of washing solvents and elution solvents were optimized to achieve optimal extraction efficiency. Good linearity of best material was achieved in the range of 0.1-400 µg/mL with correlation coefficient of chlorogenic acid (0.9994), caffeic acid (0.9997), and ferulic acid (0.9998). Recoveries between 93.5 and 102.3% were obtained at three spiked levels with relative standard deviation ≤3.1%. The proposed method was successfully applied for the determination of phenolic acids in Chinese Wolfberry drink sample.


Asunto(s)
Jugos de Frutas y Vegetales/análisis , Hidroxibenzoatos/análisis , Lycium/química , Extractos Vegetales/aislamiento & purificación , Silanos/química , Extracción en Fase Sólida/métodos , Cromatografía Líquida de Alta Presión , Grafito/química , Extractos Vegetales/análisis , Polietileneimina/química , Porosidad , Extracción en Fase Sólida/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA