Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 287
Filtrar
1.
BMC Surg ; 24(1): 194, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38907190

RESUMEN

BACKGROUND: posterior pedicle screw fixation is common method, one of the most severe complications is iatrogenic vascular damage, no report investigated association of different introversion angles (INTAs) and length of pedicle screw. The aims were to investigate the optimal introversion angle and length of pedicle screw for improving the safety of the operation, and to analyze the differences of vascular damage types at L1-S1. METHODS: Lumbar CT imaging data from110 patients were analyzed by DICOM software, and all parameters were measured by new Cartesian coordinate system, INTAs (L1-L5:5°,10°,15°,S1: 0°, 5°,10°,15°), DO-AVC (the distance between the origin (O) with anterior vertebral cortex (AVC)), DAVC-PGVs (the distance between AVC and the prevertebral great vessels (PGVs)), DO-PGVs (the distance between the O and PGVs). At different INTAs, DAVC-PGVs were divided into four grades: Grade III: DAVC-PGVs ≤ 3 mm, Grade II: 3 mm < DAVC-PGVs ≤ 5 mm, Grade I: DAVC-PGVs > 5 mm, and N: the not touching PGVs. RESULTS: The optimal INTA was 5° at L1-L3, the left was 5° and the right was 15° at L4, and screw length was less than 50 mm at L1-L4. At L5, the left optimal INTA was 5° and the right was 10°, and screw length was less than 45 mm. The optimal INTA was 15° at S1, and screw length was less than 50 mm. However, screw length was less than 40 mm when the INTA was 0° or 5° at S1. CONCLUSIONS: At L5-S1, the risk of vascular injury is the highest. INTA and length of the pedicle screw in lumbar operation are closely related. 3 mm interval of screw length may be more preferable to reduce vascular damage.


Asunto(s)
Vértebras Lumbares , Tornillos Pediculares , Fusión Vertebral , Lesiones del Sistema Vascular , Humanos , Femenino , Masculino , Persona de Mediana Edad , Vértebras Lumbares/cirugía , Vértebras Lumbares/diagnóstico por imagen , Anciano , Lesiones del Sistema Vascular/prevención & control , Lesiones del Sistema Vascular/etiología , Adulto , Fusión Vertebral/métodos , Fusión Vertebral/instrumentación , Tomografía Computarizada por Rayos X , Sacro/cirugía , Sacro/diagnóstico por imagen , Sacro/lesiones , Estudios Retrospectivos
2.
J Arthroplasty ; 39(4): 1088-1092, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37918488

RESUMEN

BACKGROUND: Iatrogenic vascular injury during total hip arthroplasty (THA) is rare, reported at rates of 0.05 to 0.3%, but a potentially limb-threatening and life-threatening complication. We aimed to describe safe and danger zones for the superior gluteal vessel bundle (SGV bundle) with reference to different THA approaches. METHODS: There were 27 formalin-fixed cadavers with 49 hemipelves dissected. The course and distribution of the SGV bundle were investigated with the help of anatomical landmarks like the greater trochanter, the iliac tubercle (IT), and the ischial tuberosity. RESULTS: We found and exposed the SGV bundle in all 49 specimens with no sex-specific differences. No SGV bundle was encountered up to 28 mm from the greater trochanter and up to 16 mm below the IT. The zone with the highest probability of finding the vessels was 25 to 65 mm below the IT in 39 (80%) cases - defining a danger zone (in relation to the skin incision) in the proximal fourth for the direct anterior approach, in the proximal half for the antero-lateral approach, in the proximal fifth for the direct lateral approach, and almost no danger zone for the posterior approach. CONCLUSIONS: Special care in proximal instrument placement should be taken during THA. When extending one of the surgical approaches, manipulations in the proximal, cranial surgical window should be performed with the utmost care to avoid SGV bundle injury.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Lesiones del Sistema Vascular , Humanos , Nalgas/cirugía , Cadáver , Fémur , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/prevención & control
3.
Arch Orthop Trauma Surg ; 144(5): 2119-2125, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38492060

RESUMEN

INTRODUCTION: The aim of this study is to assess the risk of peroneal artery injury of hardware placement at the fixation of syndesmotic injuries. MATERIALS AND METHODS: The lower extremity computed tomography angiography was used to design the study. The syndesmosis screw placement range was simulated every 0.5 cm, from 0.5 to 5 cm proximal to the ankle joint. The screw axes were drawn as 20°, 30° or individual angle according to the femoral epicondylar axis. The proximity between the screw axis and the peroneal artery was measured in millimeters. Potential peroneal artery injury was noted if the distance between the peroneal artery to the axis of the simulated screw was within the outer shaft radius of the simulated screw. The Pearson chi-square test was used and a p-value < 0.05 was considered significant. RESULTS: The potential for injury to the peroneal artery increased as the syndesmosis screw level rose proximally from the ankle joint level or as the diameter of the syndesmosis screw increasds. In terms of syndesmosis screw trajection, the lowest risk of injury was observed with the syndesmosis screw angle of 20°. Simulations with a screw diameter of 3.5 mm exhibited the least potential for peroneal artery injury. CONCLUSION: Thanks to this radiological anatomy simulation study, we believe that we have increased the awareness of the peroneal artery potential in syndesmosis screw application. Each syndesmosis screw placement option may have different potential for injury to the peroneal artery. To decrease the peroneal artery injury potential, we recommend the followings. If individual syndesmosis screw angle trajection can be measured, place the screw 1.5 cm proximal to the ankle joint using a 3.5 mm screw shaft. If not, fix it with 30° trajection regardless of the screw diameter at the same level. If the most important issue is the peroneal artery circulation, use the screw level up to 1 cm proximal to the ankle joint regardless of the screw angle trajection and screw diameter.


Asunto(s)
Tornillos Óseos , Angiografía por Tomografía Computarizada , Humanos , Tornillos Óseos/efectos adversos , Angiografía por Tomografía Computarizada/métodos , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/prevención & control , Lesiones del Sistema Vascular/diagnóstico por imagen , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/efectos adversos , Traumatismos del Tobillo/cirugía , Traumatismos del Tobillo/diagnóstico por imagen , Arterias/lesiones , Arterias/diagnóstico por imagen , Arterias/anatomía & histología
4.
Pak J Pharm Sci ; 37(5): 917-926, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39369441

RESUMEN

We investigated the effect of Sanhuang ointment on the indwelling time and vein injury repair in patients receiving intravenous infusion via peripheral venous indwelling needles. Patients (n=120) who received infusion via peripheral venous indwelling needles were randomized into Sanhuang ointment, Hirudoid and blank control groups. The indwelling time, venous injury and repair rate, venous intimal roughness rate, vascular wall thickening rate, thrombosis rate and blood flow velocity were compared within 24h and on day 4 post-needle removal. The indwelling time in the Sanhuang ointment group was 7 (6,8) days, significantly longer than that in the Hirudoid (5(4,6) days) and blank control groups (4(3,5) days) (P<0.01). Within 24h of needle removal, differences in venous injury and repair grades, intimal roughness, wall thickening, thrombosis and blood flow were not significant (P>0.05). On day 4, the rates of venous intimal roughness, vascular wall thickening and thrombosis were significantly lower, while the blood flow velocity and venous repair rates were significantly higher in the Sanhuang ointment group than those in the Hirudoid and blank control groups (P<0.05). Sanhuang ointment application extends peripheral venous indwelling time and promotes vein repair without increased injury risk.


Asunto(s)
Medicamentos Herbarios Chinos , Pomadas , Humanos , Masculino , Femenino , Persona de Mediana Edad , Infusiones Intravenosas , Adulto , Medicamentos Herbarios Chinos/administración & dosificación , Venas/efectos de los fármacos , Agujas , Factores de Tiempo , Lesiones del Sistema Vascular/prevención & control , Anciano , Velocidad del Flujo Sanguíneo/efectos de los fármacos
5.
J Pediatr Orthop ; 42(8): e847-e851, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35819314

RESUMEN

BACKGROUND: Displaced pediatric tibial tubercle fractures are commonly stabilized with screws directed posteriorly toward neurovascular structures. Here, we (1) characterize the variation of the popliteal artery among pediatric patients; and (2) recommend a safe screw trajectory for fixation of tibial tubercle fractures. METHODS: We retrospectively identified 42 patients (42 knees; 29 female) aged 12-17 years with lower-extremity magnetic resonance imaging (MRI) at a tertiary academic center. The mean patient age was 14.5 (range: 12-17) years, and the mean body mass index value was 19.1 (range: 14.9-25.1). We included patients with open physes or visible physeal scars and excluded those with prior instrumentation or lower-extremity injury. Using sagittal MRI, we measured the distances from 5 levels each on the anterior and posterior tibial cortex to the popliteal artery (level 1, midpoint of proximal tibial epiphysis; level 2, the proximal extent of the tubercle; level 3, tubercle prominence; level 4, 2 cm distal to the proximal extent of the tubercle; level 5, 4 cm distal to the proximal extent of the tubercle). Using coronal MRI, we measured the width of the tibia at each level and the distance from the lateral-most and medial-most cortex to the artery. RESULTS: The popliteal artery was laterally positioned in all knees. The mean distance between the artery and lateral-most aspect of the tibia at each level ranged from 1.9 to 2.4 cm, and from 2.3 to 3.9 cm from the medial-most aspect of the tibia. The mean distance that a screw can advance before vascular injury was 5.1 cm at level 1. The shortest mean distance to the popliteal artery was 1.7 cm, at level 5. There is minimal distance between the posterior tibial cortex and the artery at all levels. CONCLUSIONS: Understanding the position of the popliteal artery in pediatric patients can help when stabilizing tibial tubercle fractures. Because the artery is close to the posterior cortex, a drill exiting in line with the popliteal artery risks vascular injury. Therefore, we recommend that screws exit within the medial 60% of the tibia. LEVEL OF EVIDENCE: IV.


Asunto(s)
Fracturas de la Tibia , Lesiones del Sistema Vascular , Niño , Femenino , Humanos , Articulación de la Rodilla/cirugía , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/lesiones , Estudios Retrospectivos , Tibia/diagnóstico por imagen , Tibia/cirugía , Fracturas de la Tibia/complicaciones , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/prevención & control
6.
Artif Organs ; 45(2): E14-E25, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32866998

RESUMEN

Limb ischemia is a major complication associated with peripheral venoarterial extracorporeal membrane oxygenation (VA-ECMO). The high velocity jet from arterial cannulae can cause "sandblasting" injuries to the arterial endothelium, with the potential risk of distal embolization and end organ damage. The aim of this study was to identify, for a range of clinically relevant VA-ECMO cannulae and flow rates, any regions of peak flow velocity on the aortic wall which may predispose to vascular injury, and any regions of low-velocity flow which may predispose to thrombus formation. A silicone model of the aortic and iliac vessels was sourced and the right external iliac artery was cannulated. Cannulae ranged from 15 to 21 Fr in size. Simulated steady state ECMO flow rates were instituted using a magnetically levitated pump (CentriMag pump). Adaptive particle image velocimetry was performed for each cannula at 3, 3.5, 4, and 4.5 L/min. For all cannulae, in both horizontal and vertical side hole orientations, the peak velocity on the aortic wall ranged from 0.3 to 0.45 m/s, and the regions of lowest velocity flow were 0.05 m/s. The magnitude of peak velocity flow on the aortic wall was not different between a single pair versus multiple pairs of side holes. Maximum velocity flow on the aortic wall occurred earlier at a lower pump flow rate in the vertical orientation of distal side holes compared to a horizontal position. The presence of multiple paired side holes was associated with fewer low-velocity flow regions, and some retrograde flow, in the distal abdominal aorta compared to cannulae with a single pair of side holes. From this in vitro visualization study, the selection of a cannula design with multiple versus single pairs of side holes did not change the magnitude of peak velocity flow delivered to the vessel wall. Cannulae with multiple side holes were associated with fewer regions of low-velocity flow in the distal abdominal aorta. Further in vivo studies, and ideally clinical data would be required to assess any correlation of peak velocity flows with incidence of vascular injury, and any low-velocity flow regions with incidence of thrombosis.


Asunto(s)
Oxigenación por Membrana Extracorpórea/efectos adversos , Extremidades/irrigación sanguínea , Isquemia/prevención & control , Modelos Cardiovasculares , Lesiones del Sistema Vascular/prevención & control , Aorta Abdominal/lesiones , Velocidad del Flujo Sanguíneo , Cánula/efectos adversos , Diseño de Equipo , Oxigenación por Membrana Extracorpórea/instrumentación , Humanos , Arteria Ilíaca/lesiones , Isquemia/etiología , Isquemia/fisiopatología , Reología , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/fisiopatología
7.
Dermatol Surg ; 47(6): 785-790, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33941736

RESUMEN

BACKGROUND: When performing filler injection procedures to the nasojugal groove, there is the risk of iatrogenic damage to the detoured facial artery. OBJECTIVE: To determine the 3-dimensional location of the detoured facial artery. MATERIALS AND METHODS: The branches of the facial arteries from 118 cadaveric hemifaces were scanned using computed tomography and reconstructed using the Mimics software program. RESULTS: Detoured facial arteries were found in 47 of the 118 hemifaces (39.8%). Two main arterial patterns were identified: in Type I (29 of 47 cases), there were both detoured and nasolabial trunks where the facial artery originated, whereas in Type II (18 of 47 cases), there was only a detoured trunk. The detoured trunk originated 32.0 ± 5.3 mm from the midsagittal line, 5.0 ± 2.8 mm from the occlusion plane, and 5.9 ± 3.5 mm below the skin layer; the inflection of the detoured trunk was located 30.0 ± 5.6 mm laterally, 26.2 ± 4.4 mm superiorly, and 5.7 ± 2.6 mm deep. The meeting point with the inferior orbital rim plane was located 17.1 ± 3.4 mm laterally, 43.4 ± 3.1 mm superiorly, and 2.8 ± 1.7 mm deep. CONCLUSION: The 3-dimensional location of the detoured facial artery as reported here will help clinicians to avoid iatrogenic damage when they are performing filler injection procedures.


Asunto(s)
Arterias/anatomía & histología , Técnicas Cosméticas/efectos adversos , Rellenos Dérmicos/efectos adversos , Cara/irrigación sanguínea , Lesiones del Sistema Vascular/prevención & control , Adolescente , Adulto , Anciano , Variación Anatómica , Arterias/diagnóstico por imagen , Arterias/lesiones , Cadáver , Rellenos Dérmicos/administración & dosificación , Femenino , Humanos , Imagenología Tridimensional , Inyecciones Subcutáneas/efectos adversos , Inyecciones Subcutáneas/métodos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Lesiones del Sistema Vascular/etiología , Adulto Joven
8.
Surg Today ; 51(10): 1577-1582, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33575949

RESUMEN

PURPOSE: Among the variations of the right hepatic artery (RHA), the identification of an aberrant RHA arising from the gastroduodenal artery (GDA) is vital for avoiding damage to the RHA during surgery, since ligation of the GDA is necessary during pancreaticoduodenectomy (PD). However, this variation is not frequently reported. The purpose of this study was to focus on an aberrant RHA arising from the GDA, which was not noted in the classifications reported by Michels and Hiatt. METHODS: A total of 574 patients undergoing a PD between Jan 2001 and Dec 2015 at a tertiary care hospital in Switzerland (n = 366) and between Jan 2009 and May 2015 at a hospital in Japan (n = 208) were included in the analysis. Of these, preoperative CT angiography or/and MRI angiography findings were available for 532 patients. We retrospectively analyzed the hepatic artery variations, patient demographics, and surgical outcomes. RESULTS: Among the 532 patients who received a PD, an RHA originating from the GDA was observed in 19 cases (3.5%). Eleven patients (2.1%) had both an aberrant RHA and an aberrant left hepatic artery (LHA) (Hiatt Type 4). Six patients (1.2%) had a replaced CHA arising from the SMA (Hiatt Type 5). We could, therefore, correctly identify the aberration in all cases. CONCLUSIONS: We observed rarely reported but important aberrant RHA variations arising from the GDA. To prevent injury during PD in patients with this type of aberrant RHA, intensive preparations using CT and/or MRI imaging before surgery and intraoperative liver Doppler ultrasonography are considered to be essential.


Asunto(s)
Duodeno/irrigación sanguínea , Arteria Hepática/anomalías , Complicaciones Intraoperatorias/prevención & control , Pancreaticoduodenectomía/métodos , Estómago/irrigación sanguínea , Lesiones del Sistema Vascular/prevención & control , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Femenino , Arteria Hepática/diagnóstico por imagen , Arteria Hepática/lesiones , Humanos , Ligadura , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Periodo Perioperatorio , Tomografía Computarizada por Rayos X , Ultrasonografía Doppler , Adulto Joven
9.
Int J Mol Sci ; 22(16)2021 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-34445671

RESUMEN

C-type natriuretic peptide (CNP) is an important vascular regulator that is present in the brain. Our previous study demonstrated the innate neuroprotectant role of CNP in the neonatal brain after hypoxic-ischemic (HI) insults. In this study, we further explored the role of CNP in cerebrovascular pathology using both in vivo and in vitro models. In a neonatal mouse HI brain injury model, we found that intracerebroventricular administration of recombinant CNP dose-dependently reduces brain infarct size. CNP significantly decreases brain edema and immunoglobulin G (IgG) extravasation into the brain tissue, suggesting a vasculoprotective effect of CNP. Moreover, in primary brain microvascular endothelial cells (BMECs), CNP dose-dependently protects BMEC survival and monolayer integrity against oxygen-glucose deprivation (OGD). The vasculoprotective effect of CNP is mediated by its innate receptors NPR2 and NPR3, in that inhibition of either NPR2 or NPR3 counteracts the protective effect of CNP on IgG leakage after HI insult and BMEC survival under OGD. Of importance, CNP significantly ameliorates brain atrophy and improves neurological deficits after HI insults. Altogether, the present study indicates that recombinant CNP exerts vascular protection in neonatal HI brain injury via its innate receptors, suggesting a potential therapeutic target for the treatment of neonatal HI brain injury.


Asunto(s)
Hipoxia-Isquemia Encefálica/patología , Péptido Natriurético Tipo-C/farmacología , Lesiones del Sistema Vascular/prevención & control , Animales , Animales Recién Nacidos , Encéfalo/metabolismo , Edema Encefálico/patología , Infarto Encefálico/metabolismo , Lesiones Encefálicas/patología , Células Cultivadas , Células Endoteliales/metabolismo , Femenino , Hipoxia-Isquemia Encefálica/metabolismo , Infusiones Intraventriculares , Masculino , Ratones , Péptido Natriurético Tipo-C/metabolismo , Péptido Natriurético Tipo-C/fisiología , Fármacos Neuroprotectores , Lesiones del Sistema Vascular/metabolismo
10.
J Vasc Surg ; 71(1): 229-241, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31204215

RESUMEN

OBJECTIVE: Intimal hyperplasia (IH) is the main cause of therapeutic failure after vascular and endovascular surgery. However, there is currently no targeted therapy for the treatment of IH. We recently reported that the inhibition of cyclic adenosine monophosphate response element (CRE) binding protein (CREB) activation is important in vein graft IH. We focused on a decoy oligodeoxynucleotide (ODN) therapeutic strategy for suppressing IH as a clinical application. The objective of this study was to confirm the therapeutic effect of a CRE decoy ODN in an animal model as a novel therapy for preventing intimal hyperplasia as the first step of the preclinical study of our strategy. METHODS: We designed two phosphorothioate CREs and two scramble decoy ODNs and screened them using a CREB transcription assay to check their ability to bind to a CRE sequence. We chose a CRE decoy ODN with high first-binding ability and transfected it into vascular smooth muscle cells (VSMCs) in vitro. Proliferation and migration were assessed using MTS (3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium) assays and modified Boyden chamber assays. We examined CRE activity using a luciferase reporter gene assay. We assessed the expression of messenger RNAs by quantitative real-time polymerase chain reaction. In a wire-injury mouse model (C57BL6, n = 6), CRE decoy ODN was transfected into the injured vessel wall using an ultrasound-sonoporation method in vivo. Mitogen-activated protein kinase-activated protein kinase 3 (MAPKAPK3) and four and a half LIM domains 5 (FHL5) expression of pregrafting vein remnants were assessed by immunohistologic analyses. RESULTS: Compared with scramble decoy ODN, the selected CRE decoy ODN could significantly decrease CRE activity (mean ± standard error of the mean: 0.20 ± 0.03 vs 1.00 ± 0.16, n = 6; P < .05) as shown by a luciferase reporter gene assay, VSMC proliferation (0.73 ± 0.04 vs 0.89 ± 0.02, n = 6; P < .05) and migration (96.4 ± 6.1 vs 311.4 ± 19.1 migrated VSMCs/well, n = 6; P < .05) after 24-hour transfection. The CRE decoy ODN significantly suppressed the formation of IH at injured vessel walls in an animal model, as analyzed by pathologic staining (0.20 ± 0.02 vs 0.56 ± 0.08, area of the intima/area of the artery vs the control after 21 days' transfection, n = 6; P < .05). Furthermore, MAPKAPK3 and FHL5, which are CREB activators, were significantly expressed in pregrafting vein remnants in diabetes mellitus patients. CONCLUSIONS: CREB-CRE signaling is an important mechanism of IH formation, and CRE decoy therapy can help preventing IH. This study is the first part of the preclinical study of our strategy.


Asunto(s)
AMP Cíclico/metabolismo , Músculo Liso Vascular/metabolismo , Miocitos del Músculo Liso/metabolismo , Neointima , Oligodesoxirribonucleótidos/genética , Elementos de Respuesta/genética , Lesiones del Sistema Vascular/prevención & control , Animales , Proteína de Unión a CREB/genética , Proteína de Unión a CREB/metabolismo , Movimiento Celular , Proliferación Celular , Células Cultivadas , Modelos Animales de Enfermedad , Humanos , Péptidos y Proteínas de Señalización Intracelular/genética , Péptidos y Proteínas de Señalización Intracelular/metabolismo , Proteínas con Dominio LIM/genética , Proteínas con Dominio LIM/metabolismo , Masculino , Ratones Endogámicos C57BL , Músculo Liso Vascular/lesiones , Músculo Liso Vascular/patología , Miocitos del Músculo Liso/patología , Oligodesoxirribonucleótidos/metabolismo , Proteínas Serina-Treonina Quinasas/genética , Proteínas Serina-Treonina Quinasas/metabolismo , Factores de Transcripción/genética , Factores de Transcripción/metabolismo , Lesiones del Sistema Vascular/genética , Lesiones del Sistema Vascular/metabolismo , Lesiones del Sistema Vascular/patología
11.
J Biomed Sci ; 27(1): 79, 2020 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-32635910

RESUMEN

5-methoxytryptophan (5-MTP) is an endothelial factor with anti-inflammatory properties. It is synthesized from L-tryptophan via two enzymatic steps: tryptophan hydroxylase-1 (TPH-1) and hydroxyindole O-methyltransferase. Lipopolysaccharide (LPS) and pro-inflammatory cytokines suppress endothelial 5-MTP production by inhibiting TPH-1 expression. 5-MTP protects endothelial barrier function and promotes endothelial repair, while it blocks vascular smooth muscle cell migration and proliferation by inhibiting p38 MAPK activation. 5-MTP controls macrophage transmigration and activation by inhibiting p38 MAPK and NF-κB activation. 5-MTP administration attenuates arterial intimal hyperplasia, defends against systemic inflammation and prevents renal fibrosis in relevant murine models. Serum 5-MTP level is depressed in human sepsis as well as in mice with sepsis-like disorder. It is reduced in chronic kidney disease and acute myocardial infarction in humans. The reported data suggest that serum 5-MTP may be a theranostic biomarker. In summary, 5-MTP represents a new class of tryptophan metabolite which defends against inflammation and inflammation-mediated tissue damage and fibrosis. It may be a valuable lead compound for developing new drugs to treat complex human inflammatory disorders.


Asunto(s)
Antiinflamatorios/farmacología , Inflamación/prevención & control , Triptófano/análogos & derivados , Lesiones del Sistema Vascular/prevención & control , Animales , Humanos , Ratones , Triptófano/farmacología
12.
Catheter Cardiovasc Interv ; 96(3): 620-625, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32112611

RESUMEN

OBJECTIVE: To compare the outer diameter (OD) of conventional and radial sheaths from different manufacturers for sizes typically used in infant catheterization. BACKGROUND: The smallest sheath size is recommended to minimize risk of arterial injury in infants. However, sheath size refers to its internal diameter (ID), but it is the larger OD that determines risk. The OD varies between manufacturers and is frequently not known to the end user. METHODS: Three authors measured the OD of 3, 3.3, 4, 5, and 6 French (Fr) sheaths from different manufacturers using a Mitutoyo digital micrometer. Continuous variables are reported as mean ± SD. The midshaft and proximal-shaft sheath measurements were compared using an independent samples t test. Agreement between author measurements was tested using intra- and inter-rater reliability analysis. Manufacturer sheath OD measurements were obtained. Statistical significance was set at p < .05. RESULTS: There was no difference in the measured sheath diameters at the midpoint and proximally (p < .05). The intra-rater and inter-rater reliability were excellent (Intraclass correlation coefficient 1.0). Among conventional sheaths the OD varied between manufacturers, Terumo sheaths had the smallest and Galt sheaths had the largest OD. Radial sheaths had the smallest OD (1 Fr smaller) when compared to similar sized conventional sheaths. For instance, the OD of 4 Fr radial sheath (1.610 ± 0.006 mm) is essentially the same as the OD of the conventional 3 Fr (1.644 ± 0.016 mm) and 3.3 Fr (1.635 ± 0.005 mm) sheaths. CONCLUSIONS: Our study shows variation in the OD of sheaths used in infant catheterization. The radial sheaths offer the smallest OD across sizes.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Cateterismo Periférico/instrumentación , Arteria Radial , Dispositivos de Acceso Vascular , Factores de Edad , Tamaño Corporal , Cateterismo Cardíaco/efectos adversos , Catéteres Cardíacos , Cateterismo Periférico/efectos adversos , Diseño de Equipo , Humanos , Lactante , Recién Nacido , Punciones , Arteria Radial/lesiones , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/prevención & control
13.
J Endovasc Ther ; 27(1): 102-108, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31724469

RESUMEN

Purpose: To evaluate a new scoring balloon, the non-slip element (NSE) percutaneous transluminal angioplasty (PTA) balloon, in the treatment of femoropopliteal lesions by comparing angiographic dissection patterns to those of a conventional balloon. Methods: This retrospective, single-center study included 71 symptomatic patients (mean age 77.4±8.8 years; 33 men) with de novo femoropopliteal lesions <20 cm long treated with balloon angioplasty between January 2017 and May 2018. Thirty-four patients were treated with 3 inflations of an NSE balloon and 37 patients were treated with a conventional balloon. Results: Severe dissections were fewer (8.8% vs 29.7%, p=0.027) and the total dissection length was shorter (11.5±12.8 vs 35.7±24.1 mm, p=0.027) in the NSE group. The bailout stenting rate was also lower in the NSE group (17.6% vs 40.5%, p=0.035). There were no significant differences between the groups regarding lesion length (70.3±50.4 vs 77.8±56.6 mm, p=0.28), inflation time (294±162 vs 353±179 seconds, p=0.08), or inflation pressure (10.6±5.0 vs 11.3±5.3 atm, p=0.31). Conclusion: Three NSE balloon inflations may reduce severe dissections induced by balloon angioplasty in femoropopliteal lesions.


Asunto(s)
Angioplastia de Balón/instrumentación , Arteria Femoral/lesiones , Enfermedad Arterial Periférica/terapia , Arteria Poplítea/lesiones , Dispositivos de Acceso Vascular , Lesiones del Sistema Vascular/prevención & control , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/efectos adversos , Diseño de Equipo , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Japón , Masculino , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Stents , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/fisiopatología
14.
Ann Vasc Surg ; 62: 191-194, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31449950

RESUMEN

BACKGROUND: Percutaneous endovascular aortic repairs (pEVARs) are associated with access site complications. Two-device technique using 2 Perclose devices has been well established. Combined Perclose and Angioseal technique has been described as well. We sought to determine whether a hybrid Perclose and Angioseal closure technique would safely and effectively establish hemostasis in large-bore arteriotomies up to 20F. METHODS: Patients were identified as candidates for percutaneous access based on preoperative computed tomography findings, perioperative ultrasound of femoral vessels, or a combination of the 2 modalities. Prior to sheath insertion, 1 Perclose device was predeployed. At the end of pEVAR, device sheath and introducer were withdrawn over a 0.035″ wire, and partially deployed Perclose was fully deployed. The sheath and introducer were fully withdrawn and the arteriotomy was closed with a 6F Angioseal vascular closure device and completion deployment of the Perclose. Patients were followed at day 1 and day 30 and at least 1 year postintervention. RESULTS: A composite end point of complications was defined as an access site-related bleed or hematoma that required blood transfusion or an extended hospital stay, pseudoaneurysm, arteriovenous fistula, dissection, or retroperitoneal hematoma. The combined technique was initially successful in 44/45 arteriotomies (97.8%) in 24/25 patients (96.0%) with no conversions to cutdown. Sheath sizes ranged from 10F to 20F outer diameter (OD), with an average of 15.89F OD. The single-device failure was caused by a failure of the footplate to catch during deployment in the Angioseal with a 20F arteriotomy. Consequently, that was the only patient in which this closure was attempted for an arteriotomy larger than 19F. There were no early or late complications in this series. CONCLUSIONS: Large-bore arteriotomies may be safely and effectively closed using a hybrid percutaneous closure technique for sheaths up to 19F OD. Evaluation of this technique in closure of large-bore arteriotomies is ongoing and further investigation is needed to assess the value of this closure in 20F OD sheaths and above.


Asunto(s)
Enfermedades de la Aorta/cirugía , Cateterismo Periférico , Procedimientos Endovasculares , Hemorragia/prevención & control , Técnicas Hemostáticas/instrumentación , Dispositivos de Cierre Vascular , Enfermedades de la Aorta/diagnóstico por imagen , Transfusión Sanguínea , Cateterismo Periférico/efectos adversos , Procedimientos Endovasculares/efectos adversos , Diseño de Equipo , Hematoma/etiología , Hematoma/prevención & control , Hemorragia/etiología , Técnicas Hemostáticas/efectos adversos , Humanos , Tiempo de Internación , Punciones , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/prevención & control
15.
Arthroscopy ; 36(2): 492-498, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31901385

RESUMEN

PURPOSE: We assessed the risk of injury to the popliteal neurovascular bundle (PNVB) while suturing the posterior horn of the lateral meniscus (PHLM). METHODS: We simulated all-inside suturing of the PHLM using magnetic resonance imaging of 60 knees. Lines were drawn from the medial and the lateral edges of the patellar tendon to the PHLM at increasing distances from the posterior cruciate ligament (PCL) to simulate suturing device trajectory. Distance from each line to the PNVB was measured (d). A similar analysis was performed using lines drawn from 1 cm medial and 1 cm lateral to the patellar tendon. We compared the average "d" at increasing distances from the PCL, between the different simulated portal entry points. We have also analyzed the association between different demographic characteristics and the shortest distance from the PVNB to the PHLM. RESULTS: Of 1200 measurements performed, the simulated suturing trajectory transected the PNVB 343 times (28.6%). At 0 mm from the PCL, the safest portal was the 1-cm lateral portal (P < .001), with an average "d" of 2.7 mm. At 3 mm, 6 mm, 9 mm, and 12 mm from the PCL, the safest portal was the 1-cm medial portal (P < .001), with average "d" of 3.8 mm, 6.9 mm, 10.1 mm, and 13.5 mm, respectively. Average distance between the PHLM and the PNVB was 7.8 mm. Shorter distance between the PHLM and the PNVB was associated with younger age and female sex (P = .014 and .001, respectively). CONCLUSIONS: All-inside suturing of the PHLM at 0 mm from the PCL is safer with a more lateral portal. Beyond 3 mm from the PCL, a more medial portal carries a lower risk to the PNVB. Young and female patients have a shorter distance between the PHLM and the PNVB, suggesting a greater risk for injury to the PNVB. Careful preoperative magnetic resonance imaging assessment may assist in safer portal selection when planning repair of the PHLM. CLINICAL RELEVANCE: This study describes a magnetic resonance imaging-based risk assessment for injury of the PVNB while suturing the PHLM. It allows the orthopaedic surgeon a better understanding of the anatomic relationship between the popliteal neurovascular bundle and the lateral meniscus and can assist in portal selection and safety.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Meniscos Tibiales/cirugía , Arteria Poplítea/lesiones , Ligamento Cruzado Posterior/cirugía , Técnicas de Sutura/instrumentación , Suturas , Lesiones de Menisco Tibial/cirugía , Lesiones del Sistema Vascular/prevención & control , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Meniscos Tibiales/diagnóstico por imagen , Persona de Mediana Edad , Ligamento Rotuliano/cirugía , Arteria Poplítea/diagnóstico por imagen , Lesiones de Menisco Tibial/diagnóstico , Lesiones del Sistema Vascular/diagnóstico , Adulto Joven
16.
Phytother Res ; 34(4): 836-845, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31793706

RESUMEN

Hypertension is recognized to be associated with low-grade inflammation. Baicalin (BAI) is reported to possess various pharmacological including anti-inflammatory activities. This research explored the molecular mechanism by which BAI functions in human aortic endothelial cells (HAECs). HAECs were pretreated with BAI. Cell viability, apoptosis, and expressions of crucial proteins were respectively evaluated using cell counting kit-8 assay, flow cytometry, and western blot. Productions of cytokines were respectively assessed employing quantitative real-time polymerase chain reaction and enzyme-linked immunosorbent assay. Cell transfection was utilized to alter miR-145 expression. The expressions of proteins participated in JNK and p38MAPK pathways were analyzed utilizing western blot. TNF-α inducement successfully evoked inflammatory injury in HAECs, exhibiting as prominently suppressed viability, while facilitated apoptosis and productions of cytokines. However, BAI pretreatment significantly ameliorated TNF-α-triggered inflammatory injuries. Besides, miR-145 expression was markedly inhibited by TNF-α inducement, while notably elevated by BAI pretreatment. Although miR-145 overexpression had no significant influence on apoptosis, miR-145 silence observably reversed BAI pretreatment-evoked protective influences on TNF-α-induced HAECs, as well as the inhibited impacts on the levels of key proteins involved in JNK and p38MAPK pathways. This investigation illustrated that BAI relieved TNF-α-triggered injuries through upregulating miR-145 via suppressing JNK and p38MAPK pathways.


Asunto(s)
Aorta/efectos de los fármacos , Células Endoteliales/efectos de los fármacos , Flavonoides/farmacología , MicroARNs/genética , Factor de Necrosis Tumoral alfa/metabolismo , Aorta/lesiones , Aorta/metabolismo , Aorta/patología , Apoptosis/efectos de los fármacos , Apoptosis/genética , Supervivencia Celular/efectos de los fármacos , Supervivencia Celular/genética , Células Cultivadas , Enfermedad de la Arteria Coronaria/genética , Enfermedad de la Arteria Coronaria/metabolismo , Enfermedad de la Arteria Coronaria/prevención & control , Células Endoteliales/metabolismo , Humanos , Inflamación/tratamiento farmacológico , MicroARNs/metabolismo , Activación Transcripcional/efectos de los fármacos , Regulación hacia Arriba/efectos de los fármacos , Regulación hacia Arriba/genética , Lesiones del Sistema Vascular/genética , Lesiones del Sistema Vascular/metabolismo , Lesiones del Sistema Vascular/prevención & control , Proteínas Quinasas p38 Activadas por Mitógenos/metabolismo
17.
Knee Surg Sports Traumatol Arthrosc ; 28(5): 1425-1435, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31119339

RESUMEN

PURPOSE: (1) To analyse popliteal artery (PA) movement in a three-dimensional (3D) coordinate system in relation to knee flexion and high tibial osteotomy (HTO) techniques (lateral closed wedge HTO [LCHTO], uniplane medial open wedge HTO [UP-MOHTO], biplane medial open wedge HTO [BP-MOHTO]) and (2) to identify safe zones of the PA in each osteotomy plane. METHODS: Sixteen knees of patients who underwent magnetic resonance imaging with extension and 90° flexion were used to develop subject-specific 3D knee flexion models. Displacement of the PA during knee flexion was measured along the X- and Y-axis, as was the distance between the posterior tibial cortex and PA parallel to the Y-axis (d-PCA). Frontal plane safety index (FPSI) and maximal axial safe angles (MASA) of osteotomy, which represented safe zones for the osteotomy from the PA injury, were analysed. All measurements were performed along virtual osteotomy planes. Differences among the three osteotomy methods were analysed for each flexion angle using a linear mixed model. RESULTS: The average increments in d-PCA during knee flexion were 1.3 ± 2.3 mm in LCHTO (n.s.), 1.4 ± 1.2 mm in UP-MOHTO (P < 0.0001), and 1.7 ± 2.0 mm in BP-MOHTO (P = 0.015). The mean FPSIs in knee extension were 37.6 ± 5.9%, 46.4 ± 5.8%, and 45.1 ± 8.1% for LCHTO, UP-MOHTO, and BP-MOHTO, respectively. The mean MASA values in knee extension were 45.8° ± 4.4°, 37.3° ± 6.1°, and 38.9° ± 6.5° for LCHTO, UP-MOHTO, and BP-MOHTO, respectively. CONCLUSION: Although the PA moved posteriorly during knee flexion, the small (1.7 mm) increment thereof and inconsistent movements in subjects would not be of clinical relevance to PA safety during HTO. LEVEL OF EVIDENCE: Diagnostic study, Level II.


Asunto(s)
Osteoartritis de la Rodilla/cirugía , Osteotomía/efectos adversos , Osteotomía/métodos , Arteria Poplítea/lesiones , Lesiones del Sistema Vascular/prevención & control , Adulto , Simulación por Computador , Femenino , Humanos , Imagenología Tridimensional , Rodilla/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Rango del Movimiento Articular , Lesiones del Sistema Vascular/etiología , Adulto Joven
18.
Clin Anat ; 33(4): 552-557, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31301242

RESUMEN

Cerclage wiring of the humeral diaphysis entails particular danger to the radial nerve and the deep brachial artery. We sought to delineate safe zones for minimally invasive cerclage wiring of the humeral diaphysis, specifically in relation to the radial nerve and accompanying vasculature. Cerclage wires were percutaneously inserted into three groups of fresh-frozen cadaveric humeri. Group 1-proximal midshaft humerus at 30% of humeral height (n = 4); Group 2-midshaft spiral groove at 45% of humeral height (n = 4); and Group 3-distal midshaft humerus at 60% of humeral height (n = 4). Subsequently, an extensive surgical exploration of the arteries and nerves around the humerus was performed, noting any disturbance to the vessels or nerves and measuring the distance from the cerclage wire to the radial nerve. Neurovascular structures were injured in 75% of specimens when the cerclage wire was inserted at the level of the spiral groove. Both posterior structures, e.g. the radial nerve and the deep brachial artery, and medial structures, e.g., the median nerve and brachial artery, were incarcerated. Application of the cerclage at 30% or 60% of humeral height did not cause neurovascular injury. Minimally invasive application of the cerclage wire at the spiral groove, which is at 45% of humeral height, is likely to cause injury to neurovascular structures. Application of the cerclage at the proximal or distal midshaft humeral areas is associated with less risk of such injury. Clin. Anat. 33:552-557, 2020. © 2019 Wiley Periodicals, Inc.


Asunto(s)
Hilos Ortopédicos , Diáfisis/cirugía , Fijación Interna de Fracturas/métodos , Fracturas del Húmero/cirugía , Cadáver , Diáfisis/irrigación sanguínea , Diáfisis/inervación , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Traumatismos de los Nervios Periféricos/prevención & control , Lesiones del Sistema Vascular/prevención & control
19.
Surg Radiol Anat ; 42(8): 871-875, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32052161

RESUMEN

PURPOSE: Fractures of the clavicle, which has an important location and function in the upper extremity and shoulder joint, compose 10% of all fracture cases. During the osteosynthesis of clavicle fractures and in the post-operative period of patients, considering the detailed morphometric and topographic properties of the nutrient foramen of clavicle is important to avoid the disruption of arterial nutrition of the clavicle and prevent unexpected injuries. The aim of this study was to investigate the morphometric properties of the nutrient foramen of clavicle in more detail using computedtomography images. METHODS: Computed tomography images of 116 healthy individuals (56 women/60 men) who had no pathology history were included in the presented study. Computed tomography images were reconstructed three-dimensionally using free-licensed Horos v3.3.3 software. Then, distances from clavicle's nutrient foramen to sternal end, anterior and posterior edges of the clavicle were measured. Statistical analyses were completed using SPSS v21 software. RESULTS: Our results demonstrated that the nutrient foramen of clavicle was located closer to the sternal end of the clavicle. The shortest distance to the sternal edge of clavicle was measured as 3.3 cm. Analyses of gender differences indicated that statistically significant differences were in favor of men. However, topographic properties of the clavicle's nutrient foramen were not affected by age. CONCLUSION: Nutrient foramen is mostly located closer to the sternal end of clavicle. Especially during osteosynthesis of clavicle fractures at the sternal end, maintaining the arterial supply of clavicle is of great importance for increasing the post-operative life quality of patients.


Asunto(s)
Arterias/anatomía & histología , Clavícula/irrigación sanguínea , Osteón/anatomía & histología , Adulto , Anciano , Anciano de 80 o más Años , Arterias/lesiones , Clavícula/diagnóstico por imagen , Clavícula/lesiones , Clavícula/cirugía , Femenino , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Osteón/diagnóstico por imagen , Voluntarios Sanos , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Estudios Retrospectivos , Factores Sexuales , Tomografía Computarizada por Rayos X , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/prevención & control , Adulto Joven
20.
J Foot Ankle Surg ; 59(1): 95-99, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31882155

RESUMEN

Recent evidence suggests that the use of suture button devices for ankle syndesmosis fixation is increasing. Multiple studies have shown some concern about damaging the greater saphenous neurovasculature with placement of the anchor point on the medial tibial cortex. We hypothesized that an all-inside button deployment technique would allow for a low risk to medial soft tissue structures. A total of 40 syndesmosis suture buttons were placed into 10 separate cadaveric lower limbs, using the newly developed technique. Four suture buttons were sequentially placed from distal to proximal in each limb within the zone of typical syndesmosis fixation, using fluoroscopic guidance. A medial incision was then performed to evaluate the relationship of the suture buttons to the medial soft tissue structures and the medial malleolus. Thirteen of 40 suture buttons (32.5%) were placed anterior, 7 (17.5%) posterior, and 20 (50%) with a portion of the button directly deep to the saphenous vein. Two of 40 buttons (5%) were placed within the tibial periosteum, and 38 (95%) were subfascial and directly superficial to the periosteum. Four of 40 (10%) limbs revealed a perforation in the saphenous vein from the guidepin. In conclusion, risks to the medial neurovascular structures exist with the medial deployment technique, but they appear to be mitigated compared with previous publications. The necessity of a medial incision to evaluate for soft tissue entrapment may not be necessary in all patients, as this technique appears to be safe, accurate, and reproducible.


Asunto(s)
Traumatismos del Tobillo/cirugía , Articulación del Tobillo/cirugía , Traumatismos de los Nervios Periféricos/prevención & control , Anclas para Sutura , Técnicas de Sutura/efectos adversos , Lesiones del Sistema Vascular/prevención & control , Articulación del Tobillo/irrigación sanguínea , Articulación del Tobillo/inervación , Cadáver , Humanos , Masculino , Persona de Mediana Edad , Traumatismos de los Nervios Periféricos/etiología , Lesiones del Sistema Vascular/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA