Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 197
Filtrar
1.
Arch Orthop Trauma Surg ; 144(1): 197-204, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37726417

RESUMEN

INTRODUCTION: Distal radius fractures are the most commonly reported fractures in adults. Treatment has changed in recent years to open reduction and palmar plate fixation. Penetration of the dorsal screw, however, is a well-known complication. Intraoperative anteroposterior and lateral radiographs lack the exact assessment of dorsal screw length and intraoperative measurement is therefore very likely to be inaccurate in a comminuted dorsal radial cortex. Secondary extensor tendon ruptures are reported in up to 6% following palmar plate fixation of distal radius fracture. MATERIALS AND METHODS: A prospective randomized trial was performed to assess the value of the dorsal horizon view. The hypothesis was that the traditional anteroposterior and lateral fluoroscopic views aided by an axial view of the dorsal part of the radius, named dorsal horizon view, could prevent dorsal screw penetration. A total of 40 patients, 6 male and 34 female, were included in the study. Standardized anteroposterior and lateral radiographs were performed intraoperatively in 18 patients (standard group = control group). In 22 patients, intraoperative axial fluoroscopic views (dorsal horizon view) were added to anteroposterior and lateral images (horizon group). Numbers of intraoperative screw changes due to the two different radiological examinations were analyzed as well as exact postoperative CT guided measurement of screw length. RESULTS: The total numbers of intraoperative screw changes were significantly higher in the horizon group. Forty-two screws were changed in 15 patients in the horizon group while only 8 screws were changed in 3 patients in the standard group. Postoperative computed tomography scans showed significantly lower total numbers of perforating screws in the horizon group with 11 screws in 22 patients compared to 20 screws in 18 patients in the standard group (p = 0.02). CONCLUSIONS: Based on the results of this study, the dorsal horizon view improves the assessment of the correct screw length and should routinely be used in palmar plate osteosynthesis of distal radius fractures. Since screw protrusion cannot be absolutely ruled out using the dorsal horizon view, monocortical drilling or screw downsizing is still mandatory. TRIAL REGISTRATION: This clinical trial was not registered because it was a clinical examination without any experimental techniques.


Asunto(s)
Placa Palmar , Fracturas del Radio , Fracturas de la Muñeca , Adulto , Humanos , Masculino , Femenino , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Placa Palmar/cirugía , Estudios Prospectivos , Placas Óseas , Fijación Interna de Fracturas/métodos , Tornillos Óseos
2.
Arch Orthop Trauma Surg ; 143(8): 5445-5454, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36973374

RESUMEN

INTRODUCTION: Palmar plate fixation of the distal radius fracture involves dissecting the pronator quadratus (PQ). This is regardless of whether the approach is radial or ulnar to the flexor carpi radialis (FCR) tendon. It is not yet clear whether and to what extent this dissection leads to a functional loss of pronation or pronation strength. The aim of this study was to investigate the functional recovery of pronation and pronation strength after dissection of the PQ without suturing. MATERIALS AND METHODS: From October 2010 to November 2011, patients aged over 65 with fracture were prospectively enrolled in this study. Fracture stabilisation was performed via the FCR approach without suturing the PQ. Follow-up examinations took place 8 weeks and 12 months postoperatively, and pronation and supination strength were analysed by means of an especially developed measuring device. RESULTS: 212 patients were initially screened and 107 were enrolled. The range of motion compared to the healthy opposite side was Ext/Flex 75/66% 8 weeks postoperatively. Pronation was 97% with a pronation strength of 59%. After 1 year, the scores improved to Ext/Flex 83/80%. Pronation recovered to 99% and pronation strength to 78%. CONCLUSION: The present study can show a recovery of pronation as well as pronation strength in a large patient population. At the same time, the pronation strength is still significantly lower 1 year after the operation than on the opposing healthy side. As the pronation strength recovers as the grip strength and is at all times on a par with the supination strength, we believe that we can continue to refrain from re-fixating the pronator quadratus.


Asunto(s)
Placa Palmar , Fracturas del Radio , Fracturas de la Muñeca , Anciano , Humanos , Placa Palmar/cirugía , Pronación , Fracturas del Radio/cirugía , Fijación Interna de Fracturas , Placas Óseas , Rango del Movimiento Articular
3.
J Hand Surg Am ; 47(11): 1095-1100, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36075822

RESUMEN

PURPOSE: The 3-category rating of volar plate prominence in relation to the most volar edge of the distal radius (the watershed line) on lateral radiographs was reliable among a small group of surgeons and associated with the probability of flexor tendon irritation and potential rupture. Classifications are often less reliable when tested among a large group of practicing surgeons in different environments. METHODS: In this survey-based experiment, an international group of 115 fracture and upper extremity surgeons viewed 1 of 4 sets of 24 lateral radiographs (96 unique lateral radiographs) of patients with distal radius fractures who underwent volar plating in the practice of a single surgeon using 2 types of plates. Surgeons were asked to rate the following metrics: (1) the grade of plate prominence according to Soong, (2) whether the plate was more prominent than the watershed line, (3) whether the plate was separate from the bone distally, and (4) whether there is more than 5° of dorsal angulation of the distal radius articular surface. RESULTS: The interobserver agreement of the classification was "fair" (κ = 0.32; 95% confidence interval [CI] = 0.27-0.36), and grading was more reliable among surgeons who do not supervise trainees. Volar prominence was less reliable (κ = 0.034; 95% CI = 0.013-0.055) than plate separation from bone (κ = 0.50; 95% CI = 0.42-0.59) and more than 5° of dorsal angulation (κ = 0.42; 95% CI = 0.35-0.48). CONCLUSIONS: Among a large number of international practicing surgeons, the classification of volar plate prominence in 3 categories was fair. CLINICAL RELEVANCE: The diagnosis of plate prominence might develop toward criteria with moderate reliability, such as separation of the plate from the bone and residual angulation of the distal radius.


Asunto(s)
Placa Palmar , Fracturas del Radio , Radio (Anatomía) , Traumatismos de los Tendones , Humanos , Placas Óseas , Fijación Interna de Fracturas/métodos , Variaciones Dependientes del Observador , Placa Palmar/diagnóstico por imagen , Placa Palmar/cirugía , Radio (Anatomía)/diagnóstico por imagen , Radio (Anatomía)/cirugía , Fracturas del Radio/clasificación , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Reproducibilidad de los Resultados , Traumatismos de los Tendones/diagnóstico por imagen , Traumatismos de los Tendones/cirugía , Extremidad Superior , Encuestas de Atención de la Salud
4.
Anaesthesia ; 75(11): 1448-1460, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32472958

RESUMEN

Rebound pain after brachial plexus block resolution and development of long-lasting pain are problems associated with volar plate fixation for distal radius fractures. The aim of this double-blind study was to evaluate the effect of a single prophylactic intravenous dose of dexamethasone in this setting. The primary endpoint was highest pain score during the first 24 hours after surgery. We included 51 adults of ASA physical status 1-2 due to undergo planned acute fixation of the radius. All received premedication with oral paracetamol and etoricoxib, and a pre-operative brachial plexus block with ropivacaine. Patients were randomly allocated into two groups: a dexamethasone group receiving 16 mg dexamethasone intravenously at start of surgery and a control group receiving 4 ml saline. After surgery, all patients received fixed doses of paracetamol, etoricoxib and oxycodone, with further oxycodone added as needed in the first 48 hours. Pain, analgesic consumption and daily function were registered at predefined times up to 1 year after surgery. Median (IQR [range]) worst pain score in the first 24 hours, as assessed by verbal numeric rating scale (0-10), was 4 (2-6 [0-7]) in the dexamethasone group compared with 8 (5-8 [2-10]) in the placebo group (p < 0.001). Average pain score, 2 (1-4 [0-5]) vs. 5 (3-6 [0-8]), p = 0.001 and rescue oxycodone consumption, 5 (0-10 [0-35]) mg vs. 10 (5-15 [0-50]) mg, p = 0.037), respectively, were both significantly lower in the dexamethasone group compared with control from 8 to 24 hours. Brachial plexus block duration was 69% longer in the dexamethasone group, 21.5 (19.1-23.4 [12.9-24.1]) hours vs. 12.7 (11.9-15.3 [7.4-26.6]) hours, p < 0.001. Two patients (9%) in the dexamethasone group compared with 12 (50%) in the placebo group experienced worst pain scores of 8-10 during the first 36 hours (p = 0.002). At 3 and 7 days postoperatively, there were no significant differences between groups for pain scores or opioid consumption. At 6 months, 27 patients (57%) reported pain at the site of surgery, with significantly higher average pain score (p = 0.024) in the placebo group. At 1 year, two patients in the dexamethasone group reported pain compared with 10 in the placebo group (p = 0.015), and worst pain score was significantly higher in the placebo group (p = 0.018). We conclude that intravenous dexamethasone improves early postoperative analgesia and may also improve clinical outcomes after 6 and 12 months.


Asunto(s)
Analgesia/métodos , Bloqueo del Plexo Braquial/métodos , Dexametasona/farmacología , Glucocorticoides/farmacología , Placa Palmar/cirugía , Fracturas del Radio/cirugía , Administración Intravenosa , Adulto , Dexametasona/administración & dosificación , Método Doble Ciego , Femenino , Glucocorticoides/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
5.
Ann Plast Surg ; 82(5): 520-522, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30882419

RESUMEN

PURPOSE: Volar plate injuries of the proximal interphalangeal joint (PIPJ) of a finger are common, often occurring in sporting or workplace incidents. Treatment of a stable dorsal dislocation entails a conservative approach, directed at preventing hyperextension and allowing the ligament to heal in position that does not negatively impact on healing. Current treatment regimens include dorsal block splinting (DBS) in 30° of flexion, which maintains the PIPJ in flexion in order to prevent any strain on the healing tissue while attempting to restore anatomical position. Recognized complications of DBS are flexion deformities of the joint and hyperextensibility. We propose that DBS in neutral position, rather than 30° flexion, reduces hyperextensibility as well as preventing flexion deformities of the PIPJ, allowing sooner return of function and participation in daily activities. METHODS: A retrospective review of patients sustaining volar plate injuries was undertaken. Inclusion criteria involved patients splinted at either 30° or neutral position, both those having undergone surgical or conservative regimens and the joint assessed as stable. Data were collected focusing on the number of hand therapy sessions, the time from injury to discharge, active angles of flexion and extension of the PIPJ, and pain. RESULTS: Over 2 years, 125 patients were treated for volar plate injuries: 20 with DBS at neutral position and 105 DBS at 30°. There were no significant differences in patient demographics. There were fewer hand therapy appointments required for those splinted in neutral position and weeks of hand therapy predischarge. There were no flexion deformities for patients undergoing DBS at neutral position, but no difference in PIPJ extension. There were no differences in hyperextensibility or pain. CONCLUSIONS: Dorsal block splinting at neutral position results in fewer flexion deformities following volar plate injuries of the PIPJ, without resultant hyperextensibility. There are fewer demands on hand therapy. Dorsal block splinting at neutral position may result in better function for patients suffering this injury, with decreased complications and quicker return to daily activities.


Asunto(s)
Luxaciones Articulares/terapia , Placa Palmar/lesiones , Placa Palmar/cirugía , Férulas (Fijadores) , Adulto , Femenino , Humanos , Masculino , Estudios Retrospectivos
6.
J Orthop Sci ; 24(2): 263-268, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30245089

RESUMEN

BACKGROUND: Although some radiographic evaluations of the risk of flexor tendon injury following fixation of a distal radius fracture are useful, these radiographic measurements are limited because of their inability to obtain three-dimensional measurements. We hypothesized that CT-based measurements would be more sensitive indicators for risk estimation than radiography. METHODS: We retrospectively evaluated the relationship between plate positioning and the incidence of flexor tendon symptoms based on postoperative radiographic and CT-based measurements in 99 hands that were followed up for more than 12 months. We also compared the reproducibility, diagnostic accuracy, and ability to detect the plate-bone gap between radiographic and CT-based measurements. We also assessed the correlation between the volar prominence and plate-bone gap using CT. Multivariable analysis using stepwise logistic regression was performed to identify factors independently associated with tendon rupture or irritation. RESULTS: In single variable analysis, we found that the volar tilt was significantly smaller and the radiographic plate-to-critical line distance (PCL), CT-PCL, and CT-gap were significantly greater in the group with tendon irritation or rupture. Multivariable logistic regression analysis indicated that the CT-based measurement of the volar prominence is a significantly positive independent predictor of tendon rupture or irritation. CONCLUSION: CT-based measurement of the volar prominence may be one of the best radiographic predictors of the risk of flexor tendon injury following fixation of a distal radius fracture regardless of the plate type and distal prominence and the extent of rotation. This measurement may assist surgeons when deciding on the need for removal of hardware to decrease the long-term risk of flexor tendon rupture.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/efectos adversos , Imagenología Tridimensional , Fracturas del Radio/cirugía , Traumatismos de los Tendones/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Fijación Interna de Fracturas/métodos , Humanos , Japón , Modelos Logísticos , Masculino , Análisis Multivariante , Placa Palmar/cirugía , Cuidados Posoperatorios/métodos , Fracturas del Radio/diagnóstico por imagen , Estudios Retrospectivos , Medición de Riesgo , Traumatismos de los Tendones/etiología , Resultado del Tratamiento , Traumatismos de la Muñeca/diagnóstico por imagen , Traumatismos de la Muñeca/cirugía
7.
Arch Orthop Trauma Surg ; 139(3): 435-438, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30631915

RESUMEN

INTRODUCTION: Few case reports describe the development of a hematoma under oral anticoagulation as the cause of an atraumatic carpal tunnel syndrome. CASE REPORT: A 76 years old woman presented an acute atraumatic carpal tunnel syndrome of her left hand under oral anticoagulation with rivaroxaban due to atrial fibrillation. 12 years ago, palmar plate osteosynthesis of a distal radius fracture had been performed on the affected wrist. Open decompression of the carpal canal was performed due to persistent severe pain under intense pain therapy and progressive neurological symptoms. The cause of the pain was a hematoma due to a rupture of the flexor pollicis longus and the second flexor digitorum profundus tendon with concomitant synovitis at the plate's distal rim. After decompression, pain relieved and neurological deficits improved rapidly. DISCUSSION: Ruptures of the flexor tendons occur in palmar plate osteosynthesis in up to 1.5% in the long term postoperative course. Very distal plate positions, like in this case, increase that risk. Under anticoagulation, the rupture induced a hematoma increasing local pressure resulting in an acute carpal tunnel syndrome. Acute nerve compression syndromes should be treated surgically without delay. CONCLUSION: Therapy with anticoagulants may increase hematoma after tendon rupture, thus supporting the development of an atraumatic acute carpal tunnel syndrome and complicating the surgical therapy. Hardware removal after fracture healing should be advised in patients with Soong grade 2 plate positions especially those taking anticoagulants.


Asunto(s)
Síndrome del Túnel Carpiano , Hematoma , Placa Palmar/cirugía , Rivaroxabán/efectos adversos , Traumatismos de los Tendones/complicaciones , Anciano , Síndrome del Túnel Carpiano/diagnóstico , Síndrome del Túnel Carpiano/etiología , Síndrome del Túnel Carpiano/cirugía , Descompresión Quirúrgica , Inhibidores del Factor Xa/efectos adversos , Femenino , Fijación Interna de Fracturas , Hematoma/inducido químicamente , Hematoma/complicaciones , Humanos , Fracturas del Radio/cirugía , Rotura
8.
Acta Orthop ; 90(2): 123-128, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30669897

RESUMEN

Background and purpose - There is no consensus regarding optimal treatment of displaced distal radius fractures (DRFs). We compared the results of 2 treatment protocols: early palmar plating vs. primary nonoperative treatment of displaced DRFs. Patients and methods - We performed a prospective randomized controlled study including 80 patients aged ≥ 50 years with dorsally displaced DRFs, excluding AO type C3 fractures. Patients were randomized to undergo either immediate surgery with palmar plating (n = 38), or initial nonoperative treatment (n = 42) after successful closed reduction in both groups. Delayed surgery was performed in nonoperatively treated patients showing early loss of alignment (n = 16). The primary outcome measure was Disabilities of the Arm, Shoulder, and Hand (DASH) score. Results - Mean DASH scores at 24 months in the early surgery group were 7.9 vs. 14 in the initial nonoperative group (difference between means 6, 95% CI 0.1-11, p = 0.05). Delayed operation was performed on 16/42 of patients due to secondary displacement in the initial nonoperative group. In "as treated" analysis, DASH scores were 7 in the early surgery group, 13 in the nonoperative group, and 17 after delayed surgery (p = 0.02). The difference in DASH scores between early and delayed surgery was 9 points (CI 0.3-19, p = 0.02) Interpretation - Treatment of DRFs with early palmar plating resulted in better 2-year functional outcomes for ≥50-year-old patients compared with a primary nonoperative treatment protocol. Delayed surgery in case of secondary displacement was not beneficial in terms of function.


Asunto(s)
Fijación Interna de Fracturas , Complicaciones Posoperatorias , Fracturas del Radio/cirugía , Rango del Movimiento Articular , Tiempo de Tratamiento , Anciano , Placas Óseas , Femenino , Finlandia , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Humanos , Masculino , Persona de Mediana Edad , Placa Palmar/cirugía , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/fisiopatología , Fracturas del Radio/diagnóstico , Recuperación de la Función , Tiempo de Tratamiento/normas , Tiempo de Tratamiento/estadística & datos numéricos , Resultado del Tratamiento
9.
J Orthop Traumatol ; 20(1): 29, 2019 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-31432281

RESUMEN

BACKGROUND: Plate protrusion is a risk factor for flexor pollicis longus (FPL) rupture following volar locking plate (VLP) surgery. However, plate prominence on follow-up radiographs is common. We hypothesised that a VLP that does not touch the FPL tendon can appear as a plate prominence projected over the volar ridge on lateral radiographs. MATERIALS AND METHODS: We studied six current designs of widely used plates in formalin-fixed cadavers. Each plate was placed in six cadavers. We analysed 36 different plate-cadaver combinations. The main aim of plate fixation was to position the plate in the most distal position without FPL tendon contact. Radiographs were obtained using fluoroscopy. We evaluated plate prominence from the volar ridge according to the Soong grading system. RESULTS: Soong grades 0 (plate did not extend beyond volar ridge), 1 (plate protruded beyond volar ridge) and 2 (plate directly on or located beyond the volar ridge) were observed in 23 (63.9%), 9 (25.0%) and 4 (11.1%) cadavers, respectively. VariAx, DVR and VALCP showed grade 1 prominence, whereas Acu-Loc2, HYBRIX and MODE showed grade 2 prominence. CONCLUSIONS: Implant protrusion was observed in 36% of plate-cadaver combinations, even if the plate did not touch the FPL. Estimating the risk of FPL rupture using lateral radiographs alone is likely insufficient. Our findings can be applied to accurately identify the presence of implant prominence following VLP surgery.


Asunto(s)
Placas Óseas/efectos adversos , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/instrumentación , Placa Palmar/cirugía , Fracturas del Radio/cirugía , Traumatismos de los Tendones/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Cadáver , Femenino , Humanos , Masculino , Radiografía , Factores de Riesgo , Traumatismos de los Tendones/etiología
10.
Arch Orthop Trauma Surg ; 138(12): 1773-1782, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30341694

RESUMEN

INTRODUCTION: Distal radius fractures (DRF) are the most common fractures of the upper extremities. The incidence is expected to continue rising in the next years due to the increased life expectancy. Palmar locking plate stabilizing has since become the standard treatment for dorsally displaced DRF with a complication rate of 8-39% reported in the literature. Main aim of this study was to investigate the incidence of complications after DRF stabilization using palmar angular stable locking plate. METHODS: A retrospective medical records review conducted from January 2013 to December 2016 included a total of 392 patients with DRF, that were stabilized using palmar angular stable locking plate and showed a minimum follow-up of 3 months. The group comprised 259 female and 133 male patients with a mean follow-up interval of 11 months (range 3-52 months). All recorded complications were documented. Range of motion (ROM) in extension, flexion, supination, pronation, radial- and ulnar deviation of the last follow-up was noted. Age was divided into younger than 65 years (< 65 years) and older than 65 years (≥ 65 years). The primary, immediate postoperative and final checkup radiographs were scrutinized for alignment and intra-articular step-off. RESULTS: A total of 51 (13%) early and 17 late (4%) complications were recorded in 392 patients. The most common complications included carpal tunnel syndrome (3%), complex regional pain syndrome (3%) and loss of reduction (2%). Of the 68 complications, only 25 (6%) were directly related to the plate. 73% of all complications occurred in AO type C fractures. Patients without complications showed a significantly better ROM in extension, flexion, pronation and supination than patients with complications. No significant differences in incidence of complications, ROM or loss of reduction could be found between patients over and under 65 years of age. Gender and type of immobilization showed no significant influence on the complication rate. CONCLUSIONS: Stabilization of DRF by palmar angular stable locking plate is a safe form of treatment. In the majority of the cases a good clinical and radiological outcome with no complications was documented. Gender and type of immobilization had no impact on the complication rate and an age over 65 years is not associated with an increased risk for complications or restricted ROM.


Asunto(s)
Placas Óseas/efectos adversos , Fijación Interna de Fracturas/efectos adversos , Placa Palmar/cirugía , Complicaciones Posoperatorias/epidemiología , Fracturas del Radio/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fijación Interna de Fracturas/métodos , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Rango del Movimiento Articular , Estudios Retrospectivos , Resultado del Tratamiento
11.
BMC Musculoskelet Disord ; 18(1): 401, 2017 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-28923035

RESUMEN

BACKGROUND: Distal radius fractures (DRFs) are the second most common fractures, after hip fractures, seen in clinical practice. The high incidence of low-energy trauma DRFs in elderly patients raises questions about the best treatment method in terms of function, pain, and quality of life. Although the majority of these fractures are treated non-operatively with cast immobilization, valid scientific evidence of the optimal cast immobilization is lacking. In addition, several publications, including Cochrane review have outlined the need for more evidence to determine the most appropriate method of cast immobilization. METHODS: This study is a pragmatic, prospective, randomized, multi-centre trial. The trial is designed to compare two widely used cast positions (volar flexion-ulnar deviation position and functional position) for the non-operative treatment of DRF in patients over 64 years of age. The main hypothesis of the trial is that function position yields corresponding functional outcome, pain relief and quality of life when compared to the volar flexion-ulnar deviation position. The primary outcome measure is Patient Rated Wrist Evaluation (PRWE) score and the secondary outcome measures will be the Disabilities of the Arm, Shoulder and Hand (DASH) score, Visual Analogue Scale (VAS), 15-dimensional (15D) value and rate of surgical interventions. The results of the trial will be analysed after 1 and 2-years. DISCUSSION: This publication presents a prospective, pragmatic, randomized, national multi-centre trial study protocol. It provides details of patient flow, randomization, follow-up and methods of analysis of the material as well as publication plan. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT02894983 22 August 2016.


Asunto(s)
Moldes Quirúrgicos/tendencias , Placa Palmar/cirugía , Fracturas del Radio/cirugía , Cúbito/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Curación de Fractura/fisiología , Humanos , Masculino , Placa Palmar/patología , Estudios Prospectivos , Fracturas del Radio/diagnóstico , Rango del Movimiento Articular/fisiología , Resultado del Tratamiento , Cúbito/patología
12.
J Hand Surg Am ; 42(9): 700-704.e2, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28843290

RESUMEN

PURPOSE: A major concern for patients following distal radius fracture fixation is when they can resume driving. This decision has medical, legal, and safety considerations, but there are no evidence-based guidelines to assist the surgeon. The goal of this study was to observe when patients are capable of safely resuming driving following surgical fixation of the distal radius. METHODS: Patients undergoing volar plating of a distal radius fracture were prospectively enrolled. At approximately 2 and 4 weeks after surgery, patients were administered a driving examination on a closed course and given a subjective questionnaire including visual analog scale scores. All basic functions of vehicle operation were evaluated. Successful completion indicated they would pass a driving evaluation. RESULTS: Twenty-three patients were enrolled. Sixteen (69.5%) passed their first attempt (average of 18.4 days from surgery), another 4 (17.4%) passed their second attempt (31.3 days from surgery), and 3 did not complete the second examination. Patients who failed relied too much on their nonsurgical hand, were not able to control the steering wheel with 2 hands, and reported pain and insecurity when using the operative hand. Of those who passed the second attempt, the first failure was universally attributed to pain. Fifteen patients reported a return to independent driving prior to the first examination (average, 11.3 days). Of the 7 who failed, 6 reported they could control the car in an emergency, and 2 reported they would not feel safe with daily driving. Maximum pain while driving on the visual analog scale was 2.4 of 10 among those who failed compared with 1.3 among those who passed. CONCLUSIONS: Most patients could safely return to driving within 3 weeks of surgery. Pain was the primary limiting factor affecting driving ability. Safe return to driving may be warranted within 3 weeks of distal radius volar plate fixation in some patients. Persistent pain is likely the most important obstacle to a safe return to driving. TYPE OF STUDY/LEVEL OF EVIDENCE: Prognostic IV.


Asunto(s)
Conducción de Automóvil , Fracturas del Radio/cirugía , Recuperación de la Función , Anciano , Anciano de 80 o más Años , Examen de Aptitud para la Conducción de Vehículos , Placas Óseas , Fijación Interna de Fracturas , Humanos , Persona de Mediana Edad , Placa Palmar/cirugía
13.
J Hand Surg Am ; 42(12): 1034.e1-1034.e6, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28917548

RESUMEN

PURPOSE: Loss of full wrist range of motion is common after treatment of distal radius fractures. Loss of wrist extension limiting functional activities, although uncommon, can occur after volar plating of distal radius fractures. Unlike other joints in which capsular release is a common form of treatment for stiffness, this has been approached with caution in the wrist owing to concerns for carpal instability. We tested the null hypothesis that hardware removal and open volar capsular release would not lead to improved upper extremity-specific patient-reported outcome (Disabilities of the Arm, Shoulder, and Hand [DASH] questionnaire). METHODS: We conducted a retrospective chart review of patients who underwent a tenolysis of the flexor carpi radialis tendon, removal of hardware, and subperiosteal release of the volar capsule (extrinsic ligaments). The primary outcome measure was patient-reported outcome on the DASH. Secondary outcomes included wrist flexion, extension, pronation, and supination, visual analog scale for pain, and radiographs/fluoroscopy for ulnocarpal translocation. RESULTS: Eleven patients were treated with a mean follow-up of 4.5 years. Mean DASH scores improved after surgery. Mean wrist flexion, wrist extension, pronation, and supination improved after surgery. Mean visual analog scale scores did not change. The radiocarpal relationship on radiographs/fluoroscopy was normal. CONCLUSIONS: Open volar capsular release to regain wrist extension after treatment of distal radius fractures with volar locking plates is safe and effective. Patients regain wrist extension in addition to improved DASH scores. There were no radiographic/fluoroscopic or clinical signs of ulnocarpal translocation after release of the volar extrinsic ligaments. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Asunto(s)
Placas Óseas , Remoción de Dispositivos , Liberación de la Cápsula Articular , Placa Palmar/cirugía , Fracturas del Radio/cirugía , Articulación de la Muñeca/fisiopatología , Adulto , Fijación Interna de Fracturas/instrumentación , Fuerza de la Mano , Humanos , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Fracturas del Radio/complicaciones , Fracturas del Radio/fisiopatología , Rango del Movimiento Articular/fisiología , Reoperación , Estudios Retrospectivos , Tendones/cirugía , Adulto Joven
14.
J Hand Surg Am ; 42(12): 996-1001, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28927879

RESUMEN

PURPOSE: Volar plates positioned at, or distal to, the watershed line have been shown to have a higher incidence of attritional rupture of the flexor pollicis longus (FPL). In this study, we aimed to evaluate the effect of wrist extension and volar tilt on the contact between the plate and the FPL tendon in a cadaver model. We hypothesized that, following volar plate application, loss of native volar tilt increases the contact between the FPL and the plate at lower degrees of wrist extension. METHODS: A volar locking plate was applied on 6 fresh-frozen cadavers. To determine the contact between the plate and the FPL tendon, both structures were wrapped with copper wire and circuit conductivity was monitored throughout wrist motion. A lateral wrist radiograph was obtained at each circuit closure, indicating tendon-plate contact. Baseline measurements were obtained with plate positioned at Soong grades 0, 1, and 2. An extra-articular osteotomy was made and contact was recorded at various volar tilt angles (+5°, 0°, -5°, -10°, -15°, and -20°) in 3 different plate positions. A blinded observer measured the degree of wrist extension on all lateral radiographs. Data were analyzed using linear mixed-effects regression model. RESULTS: Plates placed distal to the watershed line had the most contact throughout wrist range of motion. Significantly, less wrist extension was required for contact in wrists with neutral or dorsal tilt and in distally placed volar plates. Volar tilt, wrist extension, and plate position were 3 independent risk factors determining contact between plate and tendon. CONCLUSIONS: Loss of volar tilt, increased wrist extension, and higher Soong grade plate position result in greater contact between wire-wrapped FPL tendon and plate. CLINICAL RELEVANCE: The FPL/plate contact chart generated in this study may be used to assess the risk of rupture in the clinical setting.


Asunto(s)
Placas Óseas/efectos adversos , Fijación Interna de Fracturas/efectos adversos , Placa Palmar/cirugía , Rango del Movimiento Articular/fisiología , Traumatismos de los Tendones/etiología , Articulación de la Muñeca/fisiopatología , Anciano , Cadáver , Femenino , Fijación Interna de Fracturas/instrumentación , Humanos , Masculino , Placa Palmar/patología , Placa Palmar/fisiopatología , Fracturas del Radio/cirugía , Factores de Riesgo , Rotura/etiología , Articulación de la Muñeca/patología , Articulación de la Muñeca/cirugía
15.
J Hand Surg Am ; 42(11): 935.e1-935.e5, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29101976

RESUMEN

Flexor tendon injury is a rare, but serious, complication after volar plate fixation for distal radius fractures. The plate position and prominence at the watershed line are contributing factors that cause flexor tendon injury. With the standard volar approach, the pronator quadratus (PQ) is typically elevated off the radial attachment. The distal part of the plate is often visible after repair of the PQ. We describe a "PQ-splitting" technique for covering the distal edge of the plate if primary PQ repair cannot completely cover the distal part of the plate. We also report the outcome of our series. This method can potentially prevent direct gliding of flexor tendons on the distal part of the plate and prevent flexor tendon attrition on the plate prominence.


Asunto(s)
Placas Óseas/efectos adversos , Fijación Interna de Fracturas/efectos adversos , Procedimientos de Cirugía Plástica/métodos , Fracturas del Radio/cirugía , Traumatismos de los Tendones/etiología , Traumatismos de los Tendones/cirugía , Femenino , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Humanos , Puntaje de Gravedad del Traumatismo , Masculino , Músculo Esquelético/cirugía , Placa Palmar/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/cirugía , Pronóstico , Fracturas del Radio/diagnóstico por imagen , Traumatismos de los Tendones/diagnóstico por imagen , Transferencia Tendinosa/métodos , Resultado del Tratamiento
16.
J Orthop Sci ; 22(6): 1049-1053, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28838705

RESUMEN

BACKGROUND: The purpose of this study was to determine whether a partially healed (surgical delay of 2-6 weeks) metaphyseally malaligned distal radius fracture (DRF) treated using the extended palmar approach with palmar locking plate fixation has poorer clinical or radiological outcomes than those of acute (surgical delay of ≤2 weeks) metaphyseally unstable DRF treated by palmar locking plate fixation. METHODS: We identified 24 patients (Group A) who were treated with palmar locking plate for a partially healed (surgical delay of 2-6 weeks) metaphyseally malaligned DRF. We selected 48 patients (Group B) who were treated with palmar locking plate among the acute (surgical delay of ≤2 weeks) metaphyseally unstable DRF to be individually matched in a 1:2 ratio for sex, age, and fracture type. The two study groups were compared with respect to clinical and radiological parameters. The clinical parameters examined were; wrist range of motion (flexion, extension, supination, and pronation), grip strength, and Disabilities of Arm, Shoulder and Hand (DASH) scores. Radiological measurements included radial inclination, palmar angulation, and ulnar variance. RESULTS: The wrist flexion and grip strength were significantly greater in group B than group A at 3 months postoperatively. However, wrist ranges of motion, grip strengths, and DASH scores were not significantly different at 1 year postoperatively. Radiographic evaluation demonstrated no intergroup difference in terms of radial inclination, palmar angulation, or ulnar variance at 1 year postoperatively. CONCLUSIONS: Partially healed metaphyseally malaligned healed DRFs had inferior clinical outcomes to acute metaphyseally unstable DRFs in an early postoperative period, however, achieved similar clinical outcomes at 1 year postoperatively when treated using palmar locking plate fixation.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/métodos , Fracturas Mal Unidas/diagnóstico por imagen , Fracturas del Radio/cirugía , Rango del Movimiento Articular/fisiología , Traumatismos de la Muñeca/cirugía , Adulto , Anciano , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Fijación Interna de Fracturas/efectos adversos , Curación de Fractura/fisiología , Fracturas Mal Unidas/epidemiología , Humanos , Puntaje de Gravedad del Traumatismo , Inestabilidad de la Articulación/prevención & control , Masculino , Persona de Mediana Edad , Placa Palmar/cirugía , Fracturas del Radio/diagnóstico por imagen , Estudios Retrospectivos , Medición de Riesgo , Estadísticas no Paramétricas , Factores de Tiempo , Resultado del Tratamiento , Traumatismos de la Muñeca/diagnóstico por imagen
17.
J Orthop Sci ; 22(3): 447-452, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28325701

RESUMEN

PURPOSE: Early diagnosis of attritional wear of the flexor pollicis longus (FPL) tendon is essential in preventing subsequent tendon rupture. There are currently few objective methods of assessing FPL attrition. We hypothesized that color Doppler imaging could visibly detect FPL tendon attrition, and analyzed our results. METHODS: We evaluated ultrasound imaging of the contact between the FPL tendon and a volar locking plate using the real-time B-mode and Doppler waveforms of the FPL tendon using the continuous Doppler wave mode in 40 patients who underwent fixation of the distal volar locking plate for distal radius fracture. Twenty out of 40 patients underwent plate removal surgery after ultrasound evaluation. We also assessed the relationship between the Doppler waveforms and attrition of the FPL tendon in these 20 patients. RESULTS: Based on the ultrasound findings (n = 40), we divided Doppler waveforms of the FPL tendon into three categories: type 1, spindle wave; type 2, spindle wave with spike; and type 3, spike wave. There were 23, 11, and six patients with type 1, 2, and 3 waveforms in the affected hand, respectively. There were 37 patients with type 1, three with type 2, and no patient with type 3 waveforms in the contralateral wrist. Of the 20 patients who underwent plate removal, five had type 3 waveforms. We found tendon fraying or partial tears in three of these five patients. In addition, all five patients showed changes to type 1 or 2 waveforms after plate removal. None of the other 15 patients with type 1 or 2 waveforms had any tendon injuries during plate removal. CONCLUSIONS: Spike Doppler waveform can indicate abnormal findings, and may be a useful method to predict tendon attrition, because of its visibility. DIAGNOSTIC STUDY: Level III evidence.


Asunto(s)
Diagnóstico Precoz , Fijación Interna de Fracturas/métodos , Placa Palmar/cirugía , Fracturas del Radio/diagnóstico , Traumatismos de los Tendones/cirugía , Tendones/diagnóstico por imagen , Ultrasonografía Doppler/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Placas Óseas , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Placa Palmar/diagnóstico por imagen , Periodo Posoperatorio , Fracturas del Radio/complicaciones , Fracturas del Radio/cirugía , Rotura , Traumatismos de los Tendones/diagnóstico , Traumatismos de los Tendones/etiología , Tendones/fisiopatología , Tendones/cirugía , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
18.
J Hand Surg Am ; 41(2): 287-90, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26684715

RESUMEN

The usual treatment for flexor digitorum profundus (FDP) avulsions as well as FDP lacerations in the distal part of zone I is tendon reinsertion into bone. Although there are several different techniques of FDP tendon reinsertion into bone, they are generally complex and have a weak tensile strength. A technique for treating these injuries is to use the volar plate of the distal interphalangeal joint as a distally based flap for tendon repair. The current communication discusses the technique and its potential complications. Initial clinical experience is encouraging and the volar plate flap technique may take its place in flexor tendon surgery.


Asunto(s)
Articulaciones de los Dedos/cirugía , Placa Palmar/cirugía , Colgajos Quirúrgicos , Técnicas de Sutura , Traumatismos de los Tendones/cirugía , Humanos
19.
J Hand Surg Am ; 41(8): 841-4, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27311863

RESUMEN

PURPOSE: Volar plating of distal radius fractures using an approach through the flexor carpi radialis (FCR) sheath is commonplace. The palmar cutaneous branch of the median nerve (PCB) is considered to run in a position adjacent to, but outside, the ulnar FCR sheath. Anatomic studies have not identified anatomic abnormalities relevant to volar plating. The purpose of this study was to determine the frequency of anomalous PCB branches entering the FCR sheath during volar plating. METHODS: This observational study involved 10 attending hand surgeons during a 7-month period (July 2015-January 2016). Surgeons assessed, documented, and reported any PCB anomalies that were encountered during volar plating through a trans-FCR approach. RESULTS: There were 182 volar plates applied that made up the study group. There were 10 cases (5.5%) of anomalous PCBs entering the FCR sheath. In 4 cases, the PCB pierced the radial FCR sheath proximally, crossed beneath the tendon, and traveled distally on the ulnar side. In 4 other cases, the PCB entered the FCR sheath proximally on the ulnar or central aspect of the sheath and remained within the sheath, staying along the ulnar or dorsal side of the tendon. In 1 case, the PCB pierced the ulnar distal aspect of the sheath and split into 2 branches. In 1 case, the PCB ran within the sheath along the radial aspect of the FCR. CONCLUSIONS: Anomalies in the course of the PCB are more common than often considered. These variants are at risk during volar surgical approaches to the wrist that proceed through the FCR sheath. CLINICAL RELEVANCE: Although dissecting along the radial side of the FCR sheath may protect the PCB in most cases, care must be taken to identify anomalous branches (if present) and protect them during surgery.


Asunto(s)
Fijación Interna de Fracturas/métodos , Nervio Mediano/anomalías , Placa Palmar/cirugía , Fracturas del Radio/cirugía , Rango del Movimiento Articular/fisiología , Traumatismos de la Muñeca/cirugía , Adulto , Anciano , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Fijación Interna de Fracturas/efectos adversos , Humanos , Puntaje de Gravedad del Traumatismo , Complicaciones Intraoperatorias/prevención & control , Masculino , Nervio Mediano/cirugía , Persona de Mediana Edad , Placa Palmar/inervación , Traumatismos de los Nervios Periféricos/prevención & control , Fracturas del Radio/diagnóstico por imagen , Recuperación de la Función , Medición de Riesgo , Resultado del Tratamiento , Traumatismos de la Muñeca/diagnóstico por imagen
20.
J Surg Res ; 193(1): 324-33, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25255722

RESUMEN

BACKGROUND: The choice between volar locking plates (VLP) and external fixation (EF) for unstable distal radius fractures have not reached a consensus. The meta-analysis of randomized controlled trials was performed to compare VLP with EF to determine the dominant strategy. MATERIALS AND METHODS: Meta-analysis was performed with a systematic search of studies conducted by using the PubMed, Embase, and Cochrane Central Register of Controlled Trials databases. The randomized controlled trials that compared VLP with EF was identified. Characteristics, functional outcomes, radiological results, and complications were manually extracted from all the selected studies. RESULTS: Six studies encompassing 445 patients met the inclusion criteria. There was significant difference between two procedures in disabilities of the arm shoulder and hand scores at 3,6, and 12 mo, visual analogue scale at 6 mo, grip strength at 3 mo, supination at 3 and 6 mo, extension at 3 mo, ulnar variance at 12 mo, and reoperation rate at 12 mo, postoperatively. However, there was no significant difference between flexion, pronation, radial deviation, and ulnar deviation at all follow-up points postoperatively and overall complications at 12 mo, postoperatively. CONCLUSIONS: EF had less reoperative rate due to complications, however, VLP had advantages in functional recovery in the early period after surgery, but two methods had similar functional recovery at 12 mo, postoperatively. Clinician should make the treatment decision with great caution for the patients who sustained unstable distal radial fractures.


Asunto(s)
Placas Óseas , Fijadores Externos , Placa Palmar/cirugía , Fracturas del Radio/cirugía , Evaluación de la Discapacidad , Humanos , Placa Palmar/diagnóstico por imagen , Radiografía , Fracturas del Radio/diagnóstico por imagen , Ensayos Clínicos Controlados Aleatorios como Asunto , Recuperación de la Función
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA