Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.718
Filtrar
Más filtros

Intervalo de año de publicación
1.
Strahlenther Onkol ; 200(1): 60-70, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37971534

RESUMEN

PURPOSE: The objective of this work is to estimate the patient positioning accuracy of a surface-guided radiation therapy (SGRT) system using an optical surface scanner compared to an X­ray-based imaging system (IGRT) with respect to their impact on intracranial stereotactic radiotherapy (SRT) and intracranial stereotactic radiosurgery (SRS). METHODS: Patient positioning data, both acquired with SGRT and IGRT systems at the same linacs, serve as a basis for determination of positioning accuracy. A total of 35 patients with two different open face masks (578 datasets) were positioned using X­ray stereoscopic imaging and the patient position inside the open face mask was recorded using SGRT. The measurement accuracy of the SGRT system (in a "standard" and an SRS mode with higher resolution) was evaluated using both IGRT and SGRT patient positioning datasets taking into account the measurement errors of the X­ray system. Based on these clinically measured datasets, the positioning accuracy was estimated using Monte Carlo (MC) simulations. The relevant evaluation criterion, as standard of practice in cranial SRT, was the 95th percentile. RESULTS: The interfractional measurement displacement vector of the SGRT system, σSGRT, in high resolution mode was estimated at 2.5 mm (68th percentile) and 5 mm (95th percentile). If the standard resolution was used, σSGRT increased by about 20%. The standard deviation of the axis-related σSGRT of the SGRT system ranged between 1.5 and 1.8 mm interfractionally and 0.5 and 1.0 mm intrafractionally. The magnitude of σSGRT is mainly due to the principle of patient surface scanning and not due to technical limitations or vendor-specific issues in software or hardware. Based on the resulting σSGRT, MC simulations served as a measure for the positioning accuracy for non-coplanar couch rotations. If an SGRT system is used as the only patient positioning device in non-coplanar fields, interfractional positioning errors of up to 6 mm and intrafractional errors of up to 5 mm cannot be ruled out. In contrast, MC simulations resulted in a positioning error of 1.6 mm (95th percentile) using the IGRT system. The cause of positioning errors in the SGRT system is mainly a change in the facial surface relative to a defined point in the brain. CONCLUSION: In order to achieve the necessary geometric accuracy in cranial stereotactic radiotherapy, use of an X­ray-based IGRT system, especially when treating with non-coplanar couch angles, is highly recommended.


Asunto(s)
Radiocirugia , Radioterapia Guiada por Imagen , Humanos , Posicionamiento del Paciente/métodos , Rayos X , Radiografía , Radioterapia Guiada por Imagen/métodos , Imagenología Tridimensional/métodos , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Errores de Configuración en Radioterapia/prevención & control
2.
World J Urol ; 42(1): 308, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38722376

RESUMEN

PURPOSE: Residual fragments not removed with urinary stone surgery may become symptomatic. In this context, this study was carried out to investigate the effect of performing retrograde intrarenal surgery, which is conventionally performed in the lithotomy position, in the modified lithotomy position (Trend-side) on stone-free rates following the surgery. METHODS: This prospective study consisted of 100 patients with a single kidney stone smaller than 2 cm between 2021 and 2023. These patients were randomized into two groups of 50 patients each to be operated on in the conventional lithotomy and Trend-side positions. Variables were compared using independent t test for continuous variables and chi-square test for categorical variables. RESULTS: There was no significant difference between the lithotomy and Trend-side position groups in terms of preoperative size, density, location of the stone, and hydronephrosis degree. Stone-free rate was 72% (n = 36) in the lithotomy group and 92% (n = 46) in the Trend-side group. Hence, there was a significant difference between the groups in the stone-free rate in favor of the Trend-side group (p = 0.009). Fragmentation time was statistically significantly shorter in the Trend-side group than in the lithotomy group (34 ± 17 min vs. 43 ± 14 min; p = 0.006). There was no significant difference between the groups in postoperative complication rates. CONCLUSION: Performing retrograde intrarenal surgery in the Trend-side position shortened the duration of fragmentation compared to the lithotomy position and was associated with higher stone-free rates. In conclusion, the Trend-side position can be safely preferred in patients undergoing retrograde intrarenal surgery due to kidney stones.


Asunto(s)
Cálculos Renales , Posicionamiento del Paciente , Humanos , Cálculos Renales/cirugía , Estudios Prospectivos , Masculino , Femenino , Persona de Mediana Edad , Posicionamiento del Paciente/métodos , Adulto , Procedimientos Quirúrgicos Urológicos/métodos , Anciano , Resultado del Tratamiento
3.
Neuroradiology ; 66(6): 963-971, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38613702

RESUMEN

PURPOSE: Few studies have investigated the influence of posture on the external jugular and diploic venous systems in the head and cranial region. In this study, we aimed to investigate the effects of posture on these systems using upright computed tomography (CT) scanning. METHODS: This study retrospectively analysed an upright CT dataset from a previous prospective study. In each patient, the diameters of the vessels in three external jugular tributaries and four diploic veins were measured using CT digital subtraction venography in both supine and sitting positions. RESULTS: Amongst the 20 cases in the original dataset, we eventually investigated 19 cases due to motion artifacts in 1 case. Compared with the supine position, most of the external jugular tributaries collapsed, and the average size significantly decreased in the sitting position (decreased by 22-49% on average). In contrast, most of the diploic veins, except the occipital diploic veins, tended to increase or remain unchanged (increased by 12-101% on average) in size in the sitting position compared with the supine position. However, the changes in the veins associated with this positional shift were not uniform; in approximately 5-30% of the cases, depending on each vein, an opposite trend was observed. CONCLUSION: Compared to the supine position, the contribution of external jugular tributaries to head venous drainage decreased in the sitting position, whilst most diploic veins maintained their contribution. These results could enhance our understanding of the physiology and pathophysiology of the head region in upright and sitting positions.


Asunto(s)
Angiografía de Substracción Digital , Venas Yugulares , Humanos , Femenino , Masculino , Venas Yugulares/diagnóstico por imagen , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Angiografía de Substracción Digital/métodos , Adulto , Posicionamiento del Paciente/métodos , Sedestación , Posición Supina , Venas Cerebrales/diagnóstico por imagen , Postura/fisiología , Anciano de 80 o más Años , Tomografía Computarizada por Rayos X/métodos , Angiografía por Tomografía Computarizada/métodos
4.
J Intensive Care Med ; 39(6): 567-576, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38105604

RESUMEN

Background & Aims: This study aims to assess the application value of the real-time camera image-guided nasoenteric tube placement in critically ill COVID-19 patients undergoing endotracheal intubation and prone position ventilation therapy. Methods: We enrolled 116 COVID-19 patients receiving endotracheal intubation and prone position ventilation therapy in the intensive care unit (ICU). Patients were randomly divided into the real-time camera image-guided nasoenteric tube placement (n = 58) and bedside blind insertion (n = 58) groups. The success rate, placement time, complications, cost, heart rate, respiratory rate, Glasgow Coma Scale (GCS), and Acute Physiology and Chronic Health Evaluation II (APACHE-II) scores were compared between the 2 groups. Results: For ICU patients with COVID-19 undergoing prone position ventilation therapy, the success rate and cost were significantly higher in the real-time camera image-guided group compared to the bedside blind group (P < .05). The placement time and complication incidence were significantly lower in the real-time camera image-guided group (P < .05). The differences in heart rate, respiratory rate, GCS scores, and APACHE-II scores were insignificant (P > .05). Conclusions: The real-time camera image-guided nasoenteric tube placement system had advantages for ICU COVID-19 patients undergoing prone position ventilation therapy, including a high success rate, short placement time, and no impact on patient position during tube placement. Real-time camera image-guided nasoenteric tube placement can be performed in any position, and demonstrates high efficiency, safety, and accuracy.


Asunto(s)
COVID-19 , Unidades de Cuidados Intensivos , Intubación Intratraqueal , Humanos , COVID-19/terapia , Masculino , Femenino , Persona de Mediana Edad , Posición Prona , Anciano , Intubación Intratraqueal/métodos , SARS-CoV-2 , Respiración Artificial/métodos , Intubación Gastrointestinal/métodos , Adulto , Posicionamiento del Paciente/métodos , Enfermedad Crítica/terapia , APACHE , Cuidados Críticos/métodos
5.
Ear Hear ; 45(4): 1033-1044, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38439150

RESUMEN

OBJECTIVES: Canalith repositioning procedures to treat benign paroxysmal positional vertigo are often applied following standardized criteria, without considering the possible anatomical singularities of the membranous labyrinth for each individual. As a result, certain patients may become refractory to the treatment due to significant deviations from the ideal membranous labyrinth, that was considered when the maneuvers were designed. This study aims to understand the dynamics of the endolymphatic fluid and otoconia, within the membranous labyrinth geometry, which may contribute to the ineffectiveness of the Epley maneuver. Simultaneously, the study seeks to explore methods to avoid or reduce treatment failure. DESIGN: We conducted a study on the Epley maneuver using numerical simulations based on a three-dimensional medical image reconstruction of the human left membranous labyrinth. A high-quality micro-computed tomography of a human temporal bone specimen was utilized for the image reconstruction, and a mathematical model for the endolymphatic fluid was developed and coupled with a spherical particle model representing otoconia inside the fluid. This allowed us to measure the position and time of each particle throughout all the steps of the maneuver, using equations that describe the physics behind benign paroxysmal positional vertigo. RESULTS: Numerical simulations of the standard Epley maneuver applied to this membranous labyrinth model yielded unsatisfactory results, as otoconia do not reach the frontside of the utricle, which in this study is used as the measure of success. The resting times between subsequent steps indicated that longer intervals are required for smaller otoconia. Using different angles of rotation can prevent otoconia from entering the superior semicircular canal or the posterior ampulla. Steps 3, 4, and 5 exhibited a heightened susceptibility to failure, as otoconia could be accidentally displaced into these regions. CONCLUSIONS: We demonstrate that modifying the Epley maneuver based on the numerical results obtained in the membranous labyrinth of the human specimen under study can have a significant effect on the success or failure of the treatment. The use of numerical simulations appears to be a useful tool for future canalith repositioning procedures that aim to personalize the treatment by modifying the rotation planes currently defined as the standard criteria.


Asunto(s)
Vértigo Posicional Paroxístico Benigno , Humanos , Vértigo Posicional Paroxístico Benigno/fisiopatología , Vértigo Posicional Paroxístico Benigno/diagnóstico por imagen , Microtomografía por Rayos X , Simulación por Computador , Hueso Temporal/diagnóstico por imagen , Membrana Otolítica/fisiología , Imagenología Tridimensional , Endolinfa/fisiología , Oído Interno/diagnóstico por imagen , Canales Semicirculares/diagnóstico por imagen , Canales Semicirculares/fisiología , Posicionamiento del Paciente/métodos
6.
J Comput Assist Tomogr ; 48(1): 110-115, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37558645

RESUMEN

ABSTRACT: This study aimed to propose a patient positioning assistive technique using computed tomography (CT) scout images. A total of 210 patients who underwent CT scans in a single center, including on the upper abdomen, were divided into a study set of 127 patients for regression and 83 patients for verification. Linear regression analysis was performed to determine the R2 coefficient and the linear equation related to the mean pixel value of the scout image and ideal table height (TH ideal ). The average pixel values of the scout image were substituted into the regression equation to estimate the TH ideal . To verify the accuracy of this method, the distance between the estimated table height (TH est ) and TH ideal was measured. The medians of age (in years), gender (male/female), height (in centimeters), and body weight (in kilograms) for the regression and verification groups were 68 versus 70, 85/42 versus 55/28, 163.8 versus 163.0, and 59.9 versus 61.9, respectively. Linear regression analysis indicated a high coefficient of determination ( R2 = 0.91) between the mean pixel value of the scout image and TH ideal . The correlation coefficient between TH ideal and TH est was 0.95 (95% confidence interval, 0.92-0.97; P < 0.0001), systematic bias was 0.2 mm, and the limits of agreement were -5.4 to 5.9 ( P = 0.78). The offset of the table height with TH est was 2.8 ± 2.1 mm. The proposed estimation method using scout images could improve the automatic optimization of table height in CT, and it can be used as a general-purpose automatic positioning technique.


Asunto(s)
Dispositivos de Autoayuda , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Abdomen , Posicionamiento del Paciente/métodos
7.
Cardiovasc Ultrasound ; 22(1): 7, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38858752

RESUMEN

AIMS: To evaluate the feasibility of a transthoracic echocardiogram using an apical-subcostal protocol in invasive mechanical ventilation (IMV) and prone position. METHODS: Prospective study of adults who required a prone position during IMV. A pillow was placed only under the left hemithorax in the prone position to elevate and ease the apical and subcostal windows. A critical care cardiologist (prone group) acquired and evaluated the images using the apical-subcostal protocol. Besides, we used ambulatory echocardiograms performed as a comparative group (supine group). RESULTS: 86 patients were included, 43 in the prone and 43 in the supine. In the prone group, the indication to perform an echocardiogram was hemodynamic monitoring. All patients were ventilated with protective parameters, and the mean end-expiratory pressure was 10.6 cmH2O. The protocol was performed entirely in 42 of 43 patients in the prone group because one patient did not have any acoustic window. In the 43 patients in the prone group analyzed and compared to the supine group, global biventricular function was assessed in 97.7% (p = 1.0), severe heart valve disease in 88.4% (p = 0.055), ruled out of the presence of pulmonary hypertension in 76.7% (p = 0.80), pericardial effusion in 93% (p = 0.12), and volume status by inferior vena cava in 93% (p = 0.48). Comparing prone versus supine position, a statistical difference was found when evaluating the left ventricle apical 2-chamber view (65.1 versus 100%, p < 0.01) and its segmental function (53.4 versus 100%, p < 0.01). CONCLUSION: The echocardiogram using an apical-subcostal protocol is feasible in patients in the IMV and prone position.


Asunto(s)
Ecocardiografía , Estudios de Factibilidad , Unidades de Cuidados Intensivos , Respiración Artificial , Humanos , Masculino , Posición Prona , Femenino , Estudios Prospectivos , Respiración Artificial/métodos , Ecocardiografía/métodos , Persona de Mediana Edad , Posicionamiento del Paciente/métodos , Anciano
8.
Retina ; 44(7): 1150-1156, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38470916

RESUMEN

PURPOSE: To compare Supine versus Prone positioning in fresh rhegmatogenous retinal detachments treated with vitrectomy and gas tamponade. METHODS: This was a prospective randomized controlled trial of 72 eyes with fresh rhegmatogenous retinal detachment that underwent 25-gauge vitrectomy: 37 eyes were allotted supine position and 35 were allotted prone position. Cases were evaluated for single-surgery reattachment rates, best-corrected visual acuity, intraocular pressure, cataract formation, and any complications. The patients were followed up for a period of 3 months. RESULTS: Both groups had similar demographics, and no significant difference was found between the two groups in terms of extent of retinal detachment, position, and number of breaks. The anatomical success after single surgery was 97.3% in the Supine group and 94.3% in the Prone group ( P = 0.609). The best-corrected visual acuity at the end of 3 months was 0.44 ± 0.27 in the Supine group and 0.35 ± 0.27 in the Prone group ( P = 0.119) with a significant increase in best-corrected visual acuity preoperatively from 0.11 ± 0.22 and 0.13 ± 0.22 in Supine and Prone groups, respectively ( P = <0.001). The intraocular pressure in the two groups was comparable at each follow-up. The rates of cataract formation were also similar in the two groups-60% and 53.8% in Supine and Prone groups, respectively ( P = 1.00). Complications such as spikes in intraocular pressure, epiretinal membrane formation, and cystoid macular edema were similar in both groups. CONCLUSION: Rates of retinal reattachment were comparable in both groups showing that supine position is equally safe and effective for adequate tamponade.


Asunto(s)
Endotaponamiento , Desprendimiento de Retina , Agudeza Visual , Vitrectomía , Humanos , Vitrectomía/métodos , Desprendimiento de Retina/cirugía , Desprendimiento de Retina/fisiopatología , Desprendimiento de Retina/diagnóstico , Posición Prona , Masculino , Femenino , Agudeza Visual/fisiología , Posición Supina , Estudios Prospectivos , Endotaponamiento/métodos , Persona de Mediana Edad , Adulto , Presión Intraocular/fisiología , Anciano , Estudios de Seguimiento , Posicionamiento del Paciente/métodos , Fluorocarburos/administración & dosificación , Resultado del Tratamiento
9.
BMC Anesthesiol ; 24(1): 179, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769487

RESUMEN

BACKGROUND: Video double-lumen tube (VDLT) intubation in lateral position is a potential alternative to intubation in supine position in patients undergoing thoracic surgery. This non-inferiority trial assessed the efficacy and safety of VDLT intubation in lateral position. METHODS: Patients (18-70 yr) undergoing right thoracoscopic lung surgery were randomized to either the left lateral position group (group L) or the supine position group (group S). The VDLT was placed under video larygoscopy. The primary endpoint was the intubation time. Secondary endpoints included VDLT displacement rate, intubation failure rate, the satisfaction of surgeon and nurse, and intubation-related adverse events. RESULTS: The analysis covered 80 patients. The total intubation time was 52.0 [20.4]s in group L and 34.3 [13.2]s in group S, with a mean difference of 17.6 s [95% confidence interval (CI): 9.9 s to 25.3 s; P = 0.050], failing to demonstrate non-inferiority with a non-inferiority margin of 10 s. Group L, compared with group S, had significantly lower VDLT displacement rate (P = 0.017) and higher nurse satisfaction (P = 0.026). No intubation failure occurred in any group. Intubation complications (P = 0.802) and surgeon satisfaction (P = 0.415) were comparable between two groups. CONCLUSIONS: The lateral VDLT intubation took longer time than in the supine position, and non-inferiority was not achieved. The incidence of displacement as the secondary endpoint was lower in the L group, possibly due to changing body positions beforehand. The indication of lateral VDLT intubation should be based on a balance between the safety of airway management and the lower incidence of displacement. TRIAL REGISTRATION: The study was registered at Chictr.org.cn with the number ChiCTR2200064831 on 19/10/2022.


Asunto(s)
Intubación Intratraqueal , Posicionamiento del Paciente , Humanos , Intubación Intratraqueal/métodos , Persona de Mediana Edad , Femenino , Masculino , Adulto , Anciano , Posicionamiento del Paciente/métodos , Adulto Joven , Procedimientos Quirúrgicos Torácicos/métodos , Adolescente , Cirugía Torácica Asistida por Video/métodos
10.
Neurosurg Rev ; 47(1): 221, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38753263

RESUMEN

Neurosurgical approach to lesions located in the occipital lobes or in the posterior fossa require very specific and time-consuming patient installations, such as the park bench position, the prone position, or the sitting position. Nevertheless, each of these position present major drawbacks regarding specific installation-related adverse events and potentially serious neurosurgical complications such as venous air embolism, iatrogenic intracranial hypertension, and supratentorial remote hematoma just to cite a few. In order to provide neurosurgeons with a simpler, physiologically-respective, easily tolerated, less time-consuming, and less provider or specific adverse events patient installation, Ochiai (1979) introduced the supine modified park-bench / lateral decubitus position. Given that this patient position has not gained wide visibility among the neurosurgical community despite its obvious numerous advantages over its classic counterparts, we provide our experience using this installation for neurosurgical approach to lesions located in the occipital lobes and in the posterior fossa.


Asunto(s)
Fosa Craneal Posterior , Procedimientos Neuroquirúrgicos , Lóbulo Occipital , Posicionamiento del Paciente , Humanos , Lóbulo Occipital/cirugía , Procedimientos Neuroquirúrgicos/métodos , Posicionamiento del Paciente/métodos , Fosa Craneal Posterior/cirugía , Posición Supina , Masculino , Postura
11.
J Ultrasound Med ; 43(7): 1353-1357, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38581172

RESUMEN

Most subscapularis and serratus anterior muscles lie between the scapula and the thoracic cage. Evaluation of this area in patients with scapulothoracic dyskinesis, snapping scapular syndrome, or interscapular pain can provide valuable information to clinicians. However, ultrasound scanning of pathologies in this area is hindered by anatomical limitations. In this study, we described a simple patient setup position and scanning method for ultrasound evaluation and guided intervention of the subscapularis and serratus anterior muscles between the scapula and thoracic cage.


Asunto(s)
Escápula , Ultrasonografía Intervencional , Humanos , Escápula/diagnóstico por imagen , Ultrasonografía Intervencional/métodos , Inyecciones Intramusculares/métodos , Músculo Esquelético/diagnóstico por imagen , Posicionamiento del Paciente/métodos
12.
J Ultrasound Med ; 43(6): 1037-1044, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38380860

RESUMEN

OBJECTIVES: No consensus regarding the optimal position and location for the measurement of the inter-rectus distance (IRD) via ultrasound (US) has been reached. By investigating the intra- and interimage reliability of IRD measurements taken in different positions and at different locations within and between testers, this study provides a theoretical basis for the current situation. METHODS: The IRD was measured via US in 46 women at 42-60 days after delivery at the superior margin of the umbilicus and 3 cm above, 5 cm above and 3 cm below the umbilicus while the women were in the supine, crunch and standing positions. In the interimage test, every participant was tested 2 times by Physician X and 1 time by Physician Y; in the intraimage test, the images collected by Physician X during the first test were saved in the machines, and two measurements were performed by Physician X and one measurement was performed by Physician Y. Paired t tests and intraclass correlation coefficients (ICCs) were calculated. RESULTS: Only the first IRD measurements by tester X and tester Y at 3 cm below the umbilicus in the crunch position were significantly different (9.56 ± 6.00 versus 11.00 ± 5.55) (P < .05). All the ICCs were greater than .75, and the intratester ICCs were greater than or equal to the corresponding intertester ICCs. The ICCs at 3 cm below the umbilicus were the smallest in the supine and crunch positions and the largest in the standing position due to the increased frequency of IRD values of 0. The ICCs for the crunch position were greatest according to the intraimage test but smallest according to the interimage test. The interimage ICCs between the two testers in the supine position at the superior margin, 3 cm above, 5 cm above, and 3 cm below the umbilicus were .972, .974, .975, and .956, respectively. CONCLUSIONS: Ultrasound imaging (USI) is a reliable method for measuring the IRD in women in the early postpartum period. The dynamic measurement of the IRD at or above the umbilicus in the supine position by different testers in real time showed the highest reliability.


Asunto(s)
Periodo Posparto , Ultrasonografía , Humanos , Femenino , Reproducibilidad de los Resultados , Ultrasonografía/métodos , Adulto , Músculos Abdominales/diagnóstico por imagen , Variaciones Dependientes del Observador , Adulto Joven , Posicionamiento del Paciente/métodos
13.
Paediatr Anaesth ; 34(6): 507-518, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38546348

RESUMEN

Patient positioning interacts with a number of body systems and can impact clinically important perioperative outcomes. In this educational review, we present the available evidence on the impact that patient positioning can have in the pediatric perioperative setting. A literature search was conducted using search terms that focused on pediatric perioperative outcomes prioritized by contemporary research in this area. Several key themes were identified: the effects of positioning on respiratory outcomes, cardiovascular outcomes, enteral function, patient and carer-centered outcomes, and soft issue injuries. We encountered considerable heterogeneity in research in this area. There may be a role for lateral positioning to reduce respiratory adverse outcomes, head elevation for intubation and improved oxygenation, and upright positioning to reduce peri-procedural anxiety.


Asunto(s)
Posicionamiento del Paciente , Atención Perioperativa , Humanos , Niño , Posicionamiento del Paciente/métodos , Atención Perioperativa/métodos
14.
Skeletal Radiol ; 53(8): 1517-1528, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38378861

RESUMEN

OBJECTIVE: Distances and angles measured from long-leg radiographs (LLR) are important for surgical decision-making. However, projectional radiography suffers from distortion, potentially generating differences between measurement and true anatomical dimension. These phenomena are not uniform between conventional radiography (CR) digital radiography (DR) and fan-beam technology (EOS). We aimed to identify differences between these modalities in an experimental setup. MATERIALS AND METHODS: A hemiskeleton was stabilized using an external fixator in neutral, valgus and varus knee alignment. Ten images were acquired for each alignment and each modality: one CR setup, two different DR systems, and an EOS. A total of 1680 measurements were acquired and analyzed. RESULTS: We observed great differences for dimensions and angles between the 4 modalities. Femoral head diameter measurements varied in the range of > 5 mm depending on the modality, with EOS being the closest to the true anatomical dimension. With functional leg length, a difference of 8.7% was observed between CR and EOS and with the EOS system being precise in the vertical dimension on physical-technical grounds, this demonstrates significant projectional magnification with CR-LLR. The horizontal distance between the medial malleoli varied by 20 mm between CR and DR, equating to 21% of the mean. CONCLUSIONS: Projectional distortion resulting in variations approaching 21% of the mean indicate, that our confidence on measurements from standing LLR may not be justified. It appears likely that among the tested equipment, EOS-generated images are closest to the true anatomical situation most of the time.


Asunto(s)
Intensificación de Imagen Radiográfica , Humanos , Intensificación de Imagen Radiográfica/métodos , Posición de Pie , Pierna/diagnóstico por imagen , Posicionamiento del Paciente/métodos
15.
Acta Med Okayama ; 78(3): 215-225, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38902209

RESUMEN

We propose a sitting position that achieves both high image quality and a reduced radiation dose in elbow joint imaging by area detector computed tomography (ADCT), and we compared it with the 'superman' and supine positions. The volumetric CT dose index (CTDIvol) for the sitting, superman, and supine positions were 2.7, 8.0, and 20.0 mGy and the dose length products (DLPs) were 43.4, 204.7, and 584.8 mGy • cm, respectively. In the task-based transfer function (TTF), the highest value was obtained for the sitting position in both bone and soft tissue images. The noise power spectrum (NPS) of bone images showed that the superman position had the lowest value up to approx. 1.1 cycles/mm or lower, whereas the sitting position had the lowest value when the NPS was greater than approx. 1.1 cycles/mm. The overall image quality in an observer study resulted in the following median Likert scores for Readers 1 and 2: 5.0 and 5.0 for the sitting position, 4.0 and 3.5 for the superman position, and 4.0 and 2.0 for the supine position. These results indicate that our proposed sitting position with ADCT of the elbow joint can provide superior image quality and allow lower radiation doses compared to the superman and supine positions.


Asunto(s)
Articulación del Codo , Posicionamiento del Paciente , Tomografía Computarizada por Rayos X , Humanos , Articulación del Codo/diagnóstico por imagen , Masculino , Femenino , Tomografía Computarizada por Rayos X/métodos , Posicionamiento del Paciente/métodos , Persona de Mediana Edad , Adulto , Dosis de Radiación , Anciano , Posición Supina
16.
Am J Otolaryngol ; 45(4): 104241, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38574512

RESUMEN

BACKGROUND: About 12.5 % of patients diagnosed with benign paroxysmal positional vertigo (BPPV), experience persistent BPPV where it is unknown why some BPPV cases are very refractory (vrBPPV) to treatment. OBJECTIVES: The primary objective was to investigate if patients with vrBPPV could be successfully treated with a mechanical rotation chair (MRC) adjusted to the exact vertical semicircular canal (SCC) angles of the individual patient. Secondary endpoint was to determine if inner ear anomalies were predominant in these patients. METHODS: This prospective clinical trial included 20 patients (main group) who underwent computed tomography (CT) with measurements of the bony island and the width between the SCC walls of the posterior leg of the lateral SCCs. The inter-SCC angles, the angles between the sagittal plane and the vertical SCCs were compared to the presumed mean standard angles of the SCCs. Of these, 14 patients (subgroup) underwent individualized treatment with the Rotundum® repositioning chair according to their measured SCC angles. RESULTS: All measured SCC angles differed significantly (p < 0.05) from the presumed mean standard SCC angles, except the angle between the sagittal plane and the left posterior SCC (p-SCC). Three out of 14 patients experienced subjective and objective remission after treatment with this MRC. Six out of 14 patients experienced either subjective remission or objective remission. CONCLUSIONS: Patients with vrBPPV have vertical SCC angles that differ significantly from the presumed mean standard SCC angles. Individualized treatment with this MRC successfully treated 21.4 % of the patients with vrBPPV and provided subjective relief for 42.9 %.


Asunto(s)
Vértigo Posicional Paroxístico Benigno , Posicionamiento del Paciente , Canales Semicirculares , Tomografía Computarizada por Rayos X , Humanos , Vértigo Posicional Paroxístico Benigno/terapia , Masculino , Femenino , Estudios Prospectivos , Persona de Mediana Edad , Anciano , Posicionamiento del Paciente/métodos , Resultado del Tratamiento , Canales Semicirculares/fisiopatología , Canales Semicirculares/diagnóstico por imagen , Rotación , Adulto
17.
Am J Otolaryngol ; 45(4): 104309, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38657533

RESUMEN

BACKGROUND: The Dix-Hallpike (DH) test is a gold standard for diagnosing benign paroxysmal positional vertigo (BPPV). However, lateral semicircular canal BPPV is not rare. We have been performing the new roll test that begins from the sitting position and contains a head-hanging position, in order not to overlook lateral canal BPPV. We noticed that transient vertical/torsional nystagmus sometimes occurs during the new roll test. OBJECTIVE: To clarify the value of the new roll test in diagnosing posterior canal BPPV and elucidate the position that elicits nystagmus. MATERIALS AND METHODS: The subjects were 100 consecutive patients (79 were female, 21 were male) with posterior canal BPPV. We classified the patients into four types based on a position that induced nystagmus. RESULTS: The patient's position that elicited nystagmus varied. The supine type accounted for 24 %, the lateral type accounted for 62 %, the head-hanging type accounted for 9 %, and the DH type accounted for 5 %. CONCLUSION: The new roll test is valuable for diagnosing posterior canalolithiasis cases. Most patients reveal vertical/torsional nystagmus in the supine or lateral position. Therefore, performing the new roll test first is efficient at the initial visit.


Asunto(s)
Vértigo Posicional Paroxístico Benigno , Canales Semicirculares , Humanos , Vértigo Posicional Paroxístico Benigno/diagnóstico , Vértigo Posicional Paroxístico Benigno/fisiopatología , Masculino , Femenino , Canales Semicirculares/fisiopatología , Persona de Mediana Edad , Anciano , Adulto , Anciano de 80 o más Años , Nistagmo Patológico/diagnóstico , Nistagmo Patológico/fisiopatología , Posicionamiento del Paciente/métodos , Pruebas de Función Vestibular/métodos , Postura/fisiología
18.
J Appl Clin Med Phys ; 25(4): e14326, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38497554

RESUMEN

PURPOSE: In radiation therapy, surface guidance can be used for patient setup and intra-fraction motion monitoring. The surface guided radiation therapy (SGRT) system from Varian Medical systems, IDENTIFYTM, consists of three pods, including cameras and a random pattern projector, mounted on the ceiling. The information captured by the cameras is used to make a reconstruction of the surface. The aim of the study was to assess the technical performance of this SGRT system on a closed-bore linac. METHODS: Phantom measurements were performed to assess the accuracy, precision, reproducibility and temporal stability of the system, both in align and in load position. Translations of the phantoms in lateral, longitudinal, and vertical direction, and rotations around three axes (pitch, roll and yaw) were performed with an accurate, in-house built, positioning stage. Different phantom geometries and different surface colors were used, and various ambient light intensities were tested. RESULTS: The accuracy of the IDENTIFYTM system at the closed-bore linac was 0.07 mm and 0.07 degrees at load position, and 0.06 mm and 0.01 degrees at align position for the white head phantom. The precision was 0.02 mm and 0.02 degrees in load position, and 0.01 mm and 0.02 degrees in align position. The accuracy for the Penta-Guide phantom was comparable to the white head phantom, with 0.06 mm and 0.01 degrees in align position. The system was slightly less accurate for translations of the CIRS lung phantom in align position (0.20 mm, 0.05 degrees). Reproducibility measurements showed a variation of 0.02 mm in load position. Regarding the temporal stability, the maximum drift over 30 min was 0.33 mm and 0.02 degrees in load position. No effect of ambient light level on the accuracy of the IDENTIFYTM system was observed. Regarding different surface colors, the accuracy of the system for a black phantom was slightly worse compared to a white surface, but not clinical relevant. CONCLUSION: The IDENTIFYTM system can adequately be used for motion monitoring on a closed-bore linac with submillimeter accuracy. The results of the performed measurements meet the clinical requirements described in the guidelines of the AAPM and the ESTRO.


Asunto(s)
Radioterapia Guiada por Imagen , Humanos , Reproducibilidad de los Resultados , Radioterapia Guiada por Imagen/métodos , Fantasmas de Imagen , Posicionamiento del Paciente/métodos , Planificación de la Radioterapia Asistida por Computador/métodos
19.
J Clin Monit Comput ; 38(3): 671-677, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38530502

RESUMEN

PURPOSE: The Prone positioning in addition to non invasive respiratory support is commonly used in patients with acute respiratory failure. The aim of this study was to assess the accuracy of an impedance-based non-invasive respiratory volume monitor (RVM) in supine and in prone position. METHODS: In sedated, paralyzed and mechanically ventilated patients in volume-controlled mode with acute respiratory distress syndrome scheduled for prone positioning it was measured and compared non-invasively tidal volume and respiratory rate provided by the RVM in supine and, subsequently, in prone position, by maintaining unchanged the ventilatory setting. RESULTS: Forty patients were enrolled. No significant difference was found between measurements in supine and in prone position either for tidal volume (p = 0.795; p = 0.302) nor for respiratory rate (p = 0.181; p = 0.604). Comparing supine vs. prone position, the bias and limits of agreements for respiratory rate were 0.12 bpm (-1.4 to 1.6) and 20 mL (-80 to 120) for tidal volume. CONCLUSIONS: The RVM is accurate in assessing tidal volume and respiratory rate in prone compared to supine position. Therefore, the RVM could be applied in non-intubated patients with acute respiratory failure receiving prone positioning to monitor respiratory function.


Asunto(s)
Respiración Artificial , Síndrome de Dificultad Respiratoria , Frecuencia Respiratoria , Volumen de Ventilación Pulmonar , Humanos , Posición Prona , Síndrome de Dificultad Respiratoria/fisiopatología , Síndrome de Dificultad Respiratoria/terapia , Posición Supina , Masculino , Femenino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación , Anciano , Respiración Artificial/métodos , Adulto , Posicionamiento del Paciente/métodos , Reproducibilidad de los Resultados , Impedancia Eléctrica
20.
Arch Orthop Trauma Surg ; 144(2): 575-581, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37889318

RESUMEN

INTRODUCTION: Postoperative cognitive dysfunction (POCD) occurs in up to 26% of patients older than 60 years 1 week after non-cardiac surgery. Intraoperative beach chair positioning (BCP) is advantageous for some types of shoulder surgery. However, this kind of positioning leads to a downward bound redistribution of blood volume, with possible hypoperfusion of the brain. We hypothesized that patients > 60 years undergoing orthopaedic shoulder surgery in a BCP might experience more POCD than patients operated in the supine position (SP). MATERIAL AND METHODS: A single-centre, prospective observational trial of 114 orthopaedic patients was performed. Study groups were established according to the type of intraoperative positioning. Anaesthesiological management was carried out similarly in both groups, including types of anaesthetics and blood pressure levels. POCD was evaluated using the Trail Making Test, the Letter-Number Span and the Regensburger Word Fluency Test. The frequency of POCD 1 week after surgery was considered primary outcome. RESULTS: Baseline characteristics, including duration of surgery, were comparable in both groups. POCD after 1 week occurred in 10.5% of SP patients and in 21.1% of BCP patients (p = 0.123; hazard ratio 2.0 (CI 95% 0.794-5.038)). After 4 weeks, the incidence of POCD decreased (SP: 8.8% vs. BCP: 5.3%; p = 0.463). 12/18 patients with POCD showed changes in their Word Fluency Tests. Near-infrared spectroscopy (NIRS) values were not lower in patients with POCD compared to those without POCD (54% (50/61) vs. 57% (51/61); p = 0.671). CONCLUSION: POCD at 1 week after surgery tended to occur more often in patients operated in beach chair position compared to patients in supine position without being statistically significant.


Asunto(s)
Procedimientos Ortopédicos , Ortopedia , Complicaciones Cognitivas Postoperatorias , Anciano , Humanos , Oxígeno , Posicionamiento del Paciente/métodos , Posición Supina , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA