Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 295
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Colorectal Dis ; 26(4): 754-759, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38443753

RESUMEN

AIM: Creation of an overlapped anastomosis using handsewn sutures for common enterotomy is very popular in robotic right colectomy (RRC) with intracorpareal anastomosis (IA). The aim of this study is to present a simple method for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in RRC with IA. METHOD: The distal ileum and proximal colon were put in overlapping positions. Enterotomies were created 2 cm proximal to the ileal stump and 8 cm distal to the colonic stump on the antimesenteric side. Subsequently, a 60 mm linear stapler with a reinforced bioabsorbable material was inserted into each lumen and fired. Finally, the bowel was elevated while holding the bioabsorbable material, and the common enterotomy was grasped with the robotic instrument in the middle and closed using a linear stapler with a reinforced bioabsorbable material. RESULTS: This technique was applied to 10 patients with tumours of the caecum, ascending colon, or transverse colon. The median operating time, anastomosis construction time, blood loss, and postoperative stay were 281 min (range 228-459 min), 12 min (range 11-17 min), 10 mL (range 0-110 mL), and 10 days (range 8-15 days), respectively. No adverse intraoperative events were observed. Postoperatively, one patient developed chylous ascites, but there were no other complications. CONCLUSION: The simple technique for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis appears to be safe and feasible.


Asunto(s)
Implantes Absorbibles , Anastomosis Quirúrgica , Colectomía , Neoplasias del Colon , Íleon , Procedimientos Quirúrgicos Robotizados , Engrapadoras Quirúrgicas , Colectomía/métodos , Colectomía/instrumentación , Humanos , Anastomosis Quirúrgica/métodos , Anastomosis Quirúrgica/instrumentación , Procedimientos Quirúrgicos Robotizados/métodos , Procedimientos Quirúrgicos Robotizados/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Anciano , Neoplasias del Colon/cirugía , Íleon/cirugía , Procedimientos Quirúrgicos sin Sutura/métodos , Procedimientos Quirúrgicos sin Sutura/instrumentación , Tempo Operativo , Colon/cirugía , Resultado del Tratamiento , Grapado Quirúrgico/métodos , Grapado Quirúrgico/instrumentación , Adulto , Tiempo de Internación
2.
Int J Med Sci ; 21(8): 1541-1551, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38903929

RESUMEN

Purpose: To compare the clinical outcomes, feasibility, and safety between groups with sutured and sutureless wound closure in congenital ectopia lentis (CEL) patients. Methods: Patients with CEL who received phacoemulsification combined with intrascleral fixation of capsular hook (CH) and implantation of capsular tension ring (CTR) and in-the-bag intraocular lens (IOL) were included in this study. Results: A total of 68 eyes of 34 patients aged 18 years or younger were enrolled in this study. Incisions of 21 patients (34 eyes) did not require sutures while sutures were applied in 21 patients (34 eyes). Postoperative uncorrected distance visual acuity, best corrected distance visual acuity and intraocular pressure measurements were comparable on follow-up visits (P > 0.05). The magnitude of surgically induced astigmatism was significantly greater (P = 0.001) in the suture group (Median: 0.47; IQ: 1.63, 2.97) than in the sutureless group (Median: 0.88; IQ: 0.63, 1.35). No cases of endophthalmitis and retinal detachment were found postoperatively in either group, while suture-related complications were observed in the sutured group, including loose suture with discomfort in 5 (14.71%) eyes, loose suture with mucus infiltration in 3 (8.82%) eyes. In total, 22 sutures (64.71%) of 34 eyes required removal. Conclusions: Sutureless clear corneal incision in CEL patients can achieve satisfactory clinical results comparable to sutured wound closure in terms of the efficacy and safety. Advantages of this approach are the reduced risk of suture-related complications, no need for additional surgery under general anesthesia for suture removal, and less cost.


Asunto(s)
Córnea , Desplazamiento del Cristalino , Implantación de Lentes Intraoculares , Procedimientos Quirúrgicos sin Sutura , Agudeza Visual , Humanos , Femenino , Masculino , Desplazamiento del Cristalino/cirugía , Adolescente , Niño , Implantación de Lentes Intraoculares/métodos , Implantación de Lentes Intraoculares/efectos adversos , Procedimientos Quirúrgicos sin Sutura/métodos , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Córnea/cirugía , Córnea/patología , Facoemulsificación/métodos , Facoemulsificación/efectos adversos , Técnicas de Sutura/efectos adversos , Resultado del Tratamiento , Estudios de Factibilidad , Suturas
3.
Int Ophthalmol ; 44(1): 269, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38914871

RESUMEN

PURPOSE: Evaluation of anterior segment parameters using the Scheimpflug corneal topography 1 year after surgery in patients who underwent sutureless scleral fixation intraocular lens (SFIOL) implantation using the modified Yamane technique and retropupillary iris-claw intraocular lens (RPIOL) implantation. METHODS: A total of 60 eyes from 57 patients who underwent sutureless SFIOL implantation and 57 eyes from 52 patients who underwent RPIOL implantation were included. Anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), anterior-posterior corneal astigmatism, and keratometric values were assessed using the Scheimpflug corneal topography (Pentacam HR, Germany). RESULTS: There was no statistically significant difference in postoperative UCVA and BCVA between the sutureless SFIOL and the RPIOL group (p = 0.236, p = 0.293, respectively). While there was no statistically significant difference in postoperative IOP between the two groups (p = 0.223), a statistically significant decrease in IOP was observed in both groups (p < 0.001). While there was no statistical difference between the sutureless SFIOL group and the RPIOL group in terms of spherical value (p = 0.441) and spherical equivalence (p = 0.237), there was a statistically significant difference in cylindrical value (p < 0.001). While there was a statistical difference in anterior astigmatism (p < 0.001), there was no statistical difference in posterior astigmatism (p = 0.405). There was no statistical difference in terms of ACV, ACD, and ACA between the sutureless SFIOL and the RPIOL group (p = 0.812, p = 0.770, p = 0.401, respectively). CONCLUSION: In this study, although there was a statistical difference in cylindrical value and anterior corneal astigmatism between the sutureless SFIOL and RPIOL groups, vision was not affected. According to this study, sutureless SFIOL and RPIOL are two successful methods in terms of visual acuity, anterior segment, and keratometry outcomes in aphakic patients after phacoemulsification.


Asunto(s)
Topografía de la Córnea , Iris , Implantación de Lentes Intraoculares , Esclerótica , Procedimientos Quirúrgicos sin Sutura , Agudeza Visual , Humanos , Masculino , Femenino , Esclerótica/cirugía , Implantación de Lentes Intraoculares/métodos , Persona de Mediana Edad , Anciano , Iris/cirugía , Procedimientos Quirúrgicos sin Sutura/métodos , Lentes Intraoculares , Estudios Retrospectivos , Segmento Anterior del Ojo/diagnóstico por imagen , Segmento Anterior del Ojo/cirugía , Adulto , Resultado del Tratamiento , Diseño de Prótesis , Afaquia Poscatarata/cirugía , Afaquia Poscatarata/fisiopatología , Estudios de Seguimiento , Afaquia/cirugía , Afaquia/fisiopatología , Afaquia/diagnóstico
4.
Zhonghua Yan Ke Za Zhi ; 60(6): 503-510, 2024 Jun 11.
Artículo en Zh | MEDLINE | ID: mdl-38825949

RESUMEN

Objective: To evaluate the efficacy of sutureless intrascleral intraocular lens (IOL) fixation with the modified Yamane technique. Methods: It was a retrospective case series study. Patients undergoing sutureless intrascleral IOL fixation with the modified Yamane technique were included at Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University from January 2022 to September 2023. Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), recorded as the logarithm of the minimum angle of resolution (logMAR), were measured before surgery and at 1 day, 3 days, 1 week, 1 month, and 3 months postoperatively. Refractive error and intraocular pressure were also checked. Anterior segment examination with a slit lamp microscope, fundus examination, anterior segment and posterior segment optical coherence tomography were performed. Intraoperative and postoperative ocular complications were documented. Results: A total of 53 patients (53 eyes) were included in this study, comprising 40 males and 13 females, with a median age of 60 (49, 68) years. Among them, the proportion of a history of trauma was 22.6% (12/53). There was 1 eye with intraoperative vitreous hemorrhage (1.9%). All eyes had no obvious hypotony, no obvious inflammation in the anterior chamber, and no pupillary abnormalities at 1 week after surgery. The mean follow-up time was (8.0±3.3) months (range, 3 to 16 months). There was no iris capture, re-dislocation, or haptic exposure of the IOL during the follow-up. The corneal endothelial cell density was (2 236±704) cells/mm2 preoperatively and (1 964±628) cells/mm2 at 1 month, with significant difference (P<0.001). The UCVA (logMAR) was 1.53±0.75 preoperatively, 0.18±0.17 at 1 month, 0.15±0.14 at 3 months, and 0.14±0.13 at the final visit (P<0.001). The UCVA (logMAR) at 1 month was significantly different from that at 3 months and the final visit (both P<0.05). At 1 month, 50.9% (27/53) of the eyes had an UCVA (logMAR)≤0.1, and the rate was 56.6% (30/53) at 3 months. The BCVA (logMAR) was 0.25±0.21, 0.03±0.06, 0.02±0.06, and 0.02±0.06 before surgery, at postoperative1 month, 3 months, and the final visit, respectively (P<0.001). The BCVA (logMAR) at 1 month was not significantly different from that at 3 months and the final visit (both P>0.05). The rate of the eyes with a BCVA (logMAR)≤0 was 81.1% (43/53) at 1 month and 83.0% (44/53) at 3 months. The IOL tilt was (5.18±2.60)° at postoperative 1 month and (5.08±2.48)° at postoperative 3 months, without statistically significant difference (P>0.05). The IOL decentration was (0.35±0.24) mm at postoperative 1 month and (0.32±0.24) mm at postoperative 3 months, without statistically significant difference (P>0.05). Conclusion: Sutureless intrascleral IOL fixation with the modified Yamane technique is simpler and more minimally invasive to achieve a stable and centered IOL implantation with fewer complications and good visual prognosis.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Humanos , Persona de Mediana Edad , Masculino , Femenino , Estudios Retrospectivos , Anciano , Implantación de Lentes Intraoculares/métodos , Esclerótica/cirugía , Agudeza Visual , Procedimientos Quirúrgicos sin Sutura/métodos
5.
Heart Vessels ; 38(7): 949-956, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36773041

RESUMEN

Sutureless offers an alternative to standard valves in surgical aortic valve replacement (SAVR). We sought to confirm the efficacy and safety of the Perceval sutureless valve in Japanese patients. Prospective observational study of 204 patients who underwent SAVR with Perceval at 19 sites in Japan between March and December 2019. The primary outcomes were 30-day mortality and postoperative complications; the secondary outcome was all-cause mortality at 1 year. Efficacy outcomes were changed in New York Heart Association (NYHA) class, pressure gradients, effective orifice area (EOA), EOA indexed to body surface area (EOAi) and severity of aortic regurgitation. Mean age was 77.7 years, 62.7% were female. Procedural success rate was 99.0%. The median cross-clamp and cardiopulmonary bypass times were 68.0 and 108 min. Perceval size S and M were implanted in 95 (46.6%) and in 76 (37.3%) of patients, respectively. The 30-day and late mortality rate were 0.5% and 4.4%, while the new permanent pacemaker implantation rate was 4.4%. Mean pressure gradient was 13.0 mmHg at discharge, reaching 11.0 mmHg at 1 year; while the mean EOA was 1.5 cm2 at discharge remaining stable up to 1 year. No moderate or severe leakages were present at discharge or at 1 year. NYHA class improved by ≥ 1 level in 55.1% of the patients at discharge and in 69.4% of the patients at 1 year. 1-year outcomes of SAVR with the Perceval sutureless valve in Japanese patients were favorable. This valve offers a promising alternative to conventional biological AVR in this Japanese population.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Procedimientos Quirúrgicos sin Sutura , Humanos , Femenino , Anciano , Masculino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Pueblos del Este de Asia , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Vigilancia de Productos Comercializados , Resultado del Tratamiento
6.
Thorac Cardiovasc Surg ; 71(7): 557-565, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36257545

RESUMEN

OBJECTIVES: The aim of this study was to investigate the need for postoperative permanent pacemaker implantation (PPI) following sutureless and rapid-deployment aortic valve replacement (SuRD-AVR) in the context of a progress report from a large multicenter international registry (SURD-IR). METHODS: We retrospectively analyzed 4,166 patients who underwent SuRD-AVR between 2008 and 2019. The primary outcome was the need for PPI before discharge. The study population was analyzed separately according to the implanted prostheses (Su cohort and RD cohort). Each cohort was divided into two groups based on the operation date: an early group ("EG" = 2008-2016) and a late group ("LG" = 2017-2019). RESULTS: The rate of PPI decreased significantly in the Su cohort over time (EG = 10.8% vs LG = 6.3%, p < 0.001). In the Su cohort, a decrease in age, risk profile, and incidence of bicuspid aortic valve, increased use of anterior right thoracotomy, reduction of cardiopulmonary bypass time and of associated procedures, and more frequent use of smaller prostheses were observed over time. In the RD cohort, the rate of PPI was stable over time (EG = 8.8% vs LG = 9.3%, p = 0.8). In this cohort, a younger age, lower risk profile, and higher incidence of concomitant septal myectomy were observed over time. CONCLUSION: Our analysis showed a significant decrease in the PPI rate in patients who underwent Su-AVR over time. Patient selection as well as surgical improvements and a more accurate sizing could be correlated with this phenomenon. The RD cohort revealed no significant differences either in patient's characteristics or in PPI rate between the two time periods.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Procedimientos Quirúrgicos sin Sutura , Humanos , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Informe de Investigación , Resultado del Tratamiento , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Procedimientos Quirúrgicos sin Sutura/efectos adversos
7.
Kyobu Geka ; 76(3): 206-209, 2023 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-36861277

RESUMEN

We herein report a case of a left ventricular pseudoaneurysm following sutureless repair for left ventricular free wall rupture. A 78-year-old woman underwent emergency sutureless repair for left ventricular free wall rupture following acute myocardial infarction. Three months later, echocardiography revealed an aneurysm in the postero-lateral wall of the left ventricle. The ventricular aneurysm was incised during reoperation, and defect in the left ventricular wall was closed with a bovine pericardial patch. Histopathologically, the aneurysm wall did not contain any myocardium, confirming the diagnosis of pseudoaneurysm. Although sutureless repair is a simple and highly effective method for oozing-type left ventricular free wall rupture, post-procedural pseudoaneurysm can develop both in acute and chronic phases. Consequently, long-term follow-up is mandatory.


Asunto(s)
Aneurisma Falso , Rotura Cardíaca , Procedimientos Quirúrgicos sin Sutura , Femenino , Animales , Bovinos , Humanos , Anciano , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Ecocardiografía
8.
Retina ; 42(1): 64-72, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34369438

RESUMEN

PURPOSE: To introduce cases of intraocular lens (IOL) malposition after sutureless intrascleral fixation. METHODS: We retrospectively analyzed the medical records of patients who underwent sutureless intrascleral fixation. Cases with postoperative IOL requiring reoperation were analyzed further. RESULTS: Of the 48 eyes that underwent sutureless intrascleral fixation of their IOL, seven eyes had postoperative IOL malposition and underwent reoperation (14.6%). There was no difference in the clinical results between the intravitreal (33 eyes) and intracameral (15 eyes) techniques, but IOL malposition requiring reoperation was more frequent in the latter (2 cases [6.1%] vs. 5 cases [33.3%], P = 0.024). In the 7 eyes that required reoperation, the visual acuity before reoperation was 0.9 ± 0.6 logMAR (20/159), whereas astigmatism was -4.8 ± 3.2 diopters. The visual acuity and cylindrical error improved to 0.1 ± 0.2 logMAR (20/25) and -2.4 ± 2.3 diopters, respectively, at 6 months after the secondary operation. CONCLUSION: In 14.6% of the patients who underwent sutureless intrascleral fixation of the IOL, IOL malposition developed and reoperation was performed. With the intravitreal technique, which uses a wider space than the intracameral technique, the frequency of postoperative IOL malposition could be reduced.


Asunto(s)
Migración de Cuerpo Extraño/etiología , Implantación de Lentes Intraoculares/efectos adversos , Lentes Intraoculares/efectos adversos , Complicaciones Posoperatorias , Refracción Ocular/fisiología , Esclerótica/cirugía , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Femenino , Estudios de Seguimiento , Migración de Cuerpo Extraño/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Agudeza Visual
9.
J Card Surg ; 37(11): 3769-3775, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35979734

RESUMEN

The sutureless technique was initially used for the treatment of postoperative pulmonary vein obstruction (PVO) in patients with total anomalous pulmonary venous connection (TAPVC). However, as the effectiveness of the sutureless technique has been confirmed and widely developed, the sutureless technique has been used for the primary treatment of high-risk children with TAPVC who are at high risk of PVO. Compared with traditional surgery, the sutureless technique significantly reduces the incidence of postoperative PVO, re-intervention rate due to PVO, and postoperative mortality, but there are potential complications such as pericardial and confluent venous anastomosis, phrenic nerve damage, air embolism. In addition, the sutureless technique is not effective in dealing with the progressive stenosis of the pulmonary veins after sutureless surgery and diffuse stenosis of extrapulmonary proximal veins and intrapulmonary veins. These make the efficacy and safety of this procedure controversial. This paper reviews the research status of the sutureless technique in TAPVC repair at home and abroad over the years.


Asunto(s)
Síndrome de Cimitarra , Procedimientos Quirúrgicos sin Sutura , Procedimientos Quirúrgicos Vasculares , Niño , Humanos , Síndrome de Cimitarra/cirugía , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Procedimientos Quirúrgicos sin Sutura/métodos , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares/efectos adversos , Procedimientos Quirúrgicos Vasculares/métodos
10.
J Card Surg ; 37(1): 242-244, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34662465

RESUMEN

BACKGROUND AND AIMS: Perceval valves are sutureless surgical bioprostheses designed for the aortic position. We report on the use of a Perceval sutureless valve for redo aortic valve replacement inside a heavily calcified homograft root in a patient with Klippel-Trenaunay-Weber syndrome. MATERIALS AND METHODS: Anonymized patient case data was extracted from hospital electronic records. RESULTS: A now 62-year-old woman with Klippel-Trenaunay-Weber syndrome underwent homograft aortic root replacement for congenital aortic valve dysplasia when she was 39 years old. She re-presented in 2012 with severe symptomatic aortic regurgitation through the homograft root. Computed tomography scanning revealed a heavily calcified homograft root. In order to avoid a high-risk redo root replacement or a challenging sutured aortic valve replacement, she underwent Perceval sutureless aortic valve implantation. As of 9.5 years following Perceval implantation, the bioprosthetic valve function remains excellent, with no transvalvular regurgitation seen. DISCUSSION AND CONCLUSION: This case reveals the value of Perceval valve implantation in redo surgery inside a hostile calcified homograft aortic root. Furthermore, we highlight the long-term durability of the Perceval sutureless bioprosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Síndrome de Klippel-Trenaunay-Weber , Procedimientos Quirúrgicos sin Sutura , Adulto , Aloinjertos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Persona de Mediana Edad , Diseño de Prótesis , Resultado del Tratamiento
11.
Med Sci Monit ; 27: e928868, 2021 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-33692329

RESUMEN

BACKGROUND In intraocular lens (IOL) sutureless intrascleral fixation using the Yamane technique, untrimmed haptics may be overlong in some cases due to varied haptic lengths and individual differences. However, whether trimming the haptic affects IOL stability remains unknown. MATERIAL AND METHODS Thirty-nine eyes of 39 patients who underwent Yamane sutureless intrascleral fixation surgery between October 2017 and February 2018 were analyzed retrospectively. Nineteen patients underwent surgery with untrimmed haptics and 20 patients with trimmed haptics. The slit-lamp examination, best-corrected visual acuity (BCVA), corneal endothelial cell density (ECD), IOL position, and complications were assessed. RESULTS The mean follow-up periods in the untrimmed and trimmed groups were 27.84±2.89 months and 27.85±2.41 months, respectively. The BCVA improved and ECD decreased in both groups postoperatively (all P<0.01). No significant differences were seen between the 2 groups in postoperative BCVA, postoperative ECD, IOL tilt at 3 months and 24 months, and IOL decentration at 3 months (all P>0.05). There were significant differences between the 2 groups in IOL decentration at 24 months (P<0.05). Compared with postoperative 3 months, both the postoperative IOL tilt and decentration at 24 months increased in the 2 groups (all P<0.01). Postoperative complications included IOL elevation (11% in the untrimmed group and 10% in the trimmed group), as well as haptic extrusion (16% in the untrimmed group). CONCLUSIONS The position of the IOL may change with time, but trimming the haptic to an optimum length tends to provide greater IOL stability.


Asunto(s)
Implantación de Lentes Intraoculares/métodos , Procedimientos Quirúrgicos sin Sutura/métodos , Anciano , China , Femenino , Humanos , Lentes Intraoculares , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos , Técnicas de Sutura , Agudeza Visual/fisiología
12.
Retina ; 41(4): 822-826, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32833409

RESUMEN

PURPOSE: To evaluate the refractive outcomes of sutureless intrascleral fixation of intraocular lens with pars plana vitrectomy. METHOD: A retrospective, consecutive cohort from multiple surgeons of a single center. Primary outcomes included spherical equivalent (SEQ) and change in SEQ (ΔSEQ) from preoperative intraocular lens power calculations. Secondary outcomes included refractive outcomes of fixation at 1.5 mm, 2 mm, and 2.5 mm posterior to the limbus. RESULTS: In total, 84 eyes of 80 patients were included. Preoperative logarithm of the minimum angle of resolution visual acuity was 1.21 ± 0.68 (20/320). The mean follow-up time was 2.33 ± 1.36 years. At 3 months, SEQ was -0.50 ± 1.59 D and ΔSEQ was 0.58 ± 1.49 D. At 1 year, SEQ was -0.55 ± 1.32 D and ΔSEQ was 0.39 ± 1.42 D. At the last follow-up, logarithm of the minimum angle of resolution visual acuity was 0.34 ± 0.34 (20/40), SEQ was -0.51 ± 1.44 D, and ΔSEQ was 0.57 ± 1.27 D. There was no difference between SEQ or ΔSEQ throughout follow-up (P = 0.97 and P = 0.96, respectively). At fixation distances more posterior to the limbus, mean ΔSEQ was more hyperopic at 3 months, 1-year, and the last follow-up (P = 0.02, P = 0.01, and P = 0.006, respectively). CONCLUSION: Refractive outcomes for sutureless intrascleral fixation of intraocular lens with pars plana vitrectomy were favorable and showed stability postoperatively. These results may aid surgeons achieve better desired refractive outcomes for this technique.


Asunto(s)
Implantación de Lentes Intraoculares/métodos , Refracción Ocular/fisiología , Esclerótica/cirugía , Procedimientos Quirúrgicos sin Sutura/métodos , Vitrectomía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Lentes Intraoculares , Masculino , Persona de Mediana Edad , Seudofaquia/fisiopatología , Estudios Retrospectivos , Agudeza Visual/fisiología
13.
Retina ; 41(4): 761-767, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32826788

RESUMEN

PURPOSE: To compare the clinical outcomes of sutured scleral and sutureless intrascleral fixations of the intraocular lens. METHODS: Medical records of patients who underwent sutureless intrascleral fixation (sutureless group) and the conventional sutured scleral fixation (sutured group) were retrospectively reviewed. Patient demographics and the clinical outcomes of the two techniques were compared before and 1, 3, and 6 months after surgery. RESULTS: Seventy patients were followed up for 6 months after the surgery: 25 patients in the sutureless group (25 eyes) and 45 in the sutured group (45 eyes). Surgery time was shorter in the sutureless group than that in the sutured group (73.00 ± 15.68 vs. 107.39 ± 25.30 minutes, P < 0.001). The visual acuity gradually improved throughout the postoperative period in both groups, and a faster visual acuity recovery was observed in the sutureless group. The cylindrical error at 6 months after the surgery was significantly lower in the sutureless group than that in the sutured group (-1.33 ± 0.55 vs. -2.29 ± 1.19 diopter, P < 0.001). CONCLUSION: Sutureless intrascleral fixation is an effective and reliable surgical technique that provides more favorable visual and refractive outcomes than the conventional sutured scleral fixation method.


Asunto(s)
Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares , Esclerótica/cirugía , Técnicas de Sutura , Procedimientos Quirúrgicos sin Sutura , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Seudofaquia/fisiopatología , Refracción Ocular/fisiología , Estudios Retrospectivos , Agudeza Visual/fisiología
14.
Retina ; 41(12): 2485-2490, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34190728

RESUMEN

PURPOSE: To describe the clinical outcomes and surgical technique in transconjunctival sutureless intrascleral fixation of intraocular lenses, including the effectiveness of haptic flanging and peripheral iridotomy. METHOD: Retrospective series of patients who underwent sutureless intrascleral fixation of three-piece intraocular lenses by a single surgeon. RESULTS: A total of 488 eyes were included in this study. Mean follow-up was 444 days. Mean preoperative best-corrected visual acuity was 20/355, and mean postoperative best-corrected visual acuity was 20/39 (P < 0.001). Intraocular lens dislocation occurred during the postoperative period in 67 (13.7%), with the majority (65.7%) occurring within 3 months after surgery. Dislocation occurred in 13 of 196 (6.6%) flanged haptics versus 54 of 292 (18.5%) unflanged haptics (P < 0.001). Reverse pupillary block occurred in 7 of 231 eyes (3.0%) without intraoperative peripheral iridotomy but only in 1 of 257 eyes (0.4%) with iridotomy (P = 0.0297). Other complications included haptic exposure (1.2%), retinal detachment (1.0%), and endophthalmitis (0.4%). CONCLUSION: This is the largest reported series of sutureless intrascleral fixation of intraocular lenses using trocar cannulas. This technique is an effective surgical option with low complication rates. The authors recommend that haptic flanging and peripheral iridotomy be performed in all cases.


Asunto(s)
Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares , Esclerótica/cirugía , Procedimientos Quirúrgicos sin Sutura/métodos , Migracion de Implante de Lente Artificial/cirugía , Humanos , Complicaciones Posoperatorias , Seudofaquia/fisiopatología , Estudios Retrospectivos , Instrumentos Quirúrgicos , Resultado del Tratamiento , Agudeza Visual/fisiología , Vitrectomía
15.
Retina ; 41(5): 940-946, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33009221

RESUMEN

PURPOSE: To compare the visual outcomes and complication rates of sutureless cannula-based intraocular lens scleral (SCILS) fixation performed with 25-gauge (25 G) versus 27-gauge (27 G) instrumentation. METHODS: A retrospective chart review of consecutive cases of eyes without capsular support that underwent SCILS fixation of a three-piece intraocular lens. Sutureless cannula-based intraocular lens scleral fixation was performed by transconjunctival use of either 25-G or 27-G trocar cannulas. During postoperative follow-up evaluations, visual acuity and intraocular pressure were measured, and slit-lamp and indirect ophthalmoscopy examinations were performed to assess for development of known complications. RESULTS: A total of 69 eyes underwent 25 G (27 eyes) or 27 G (42 eyes) SCILS fixation. The mean preoperative logarithm of the minimum angle of resolution visual acuity trended toward improvement from 0.95 ± 0.68 (20/178 Snellen equivalent) to 0.67 ± 0.64 (20/94 Snellen equivalent) for 25 G group at 1 year. Similar trend toward visual acuity improvement was seen in 27 G group with a mean preoperative logarithm of the minimum angle of resolution visual acuity of 1.43 ± 0.94 (20/538 Snellen equivalent) improving to 0.86 ± 1.00 (20/145 Snellen equivalent) at 1 year. Statistically significant improvement was seen as early as postoperative week one for 27 G group (P < 0.01), whereas statistically significant worsening was noted at the same time in 25 G group (P = 0.01). There was a statistically significant reduction in intraocular lens displacement (P = 0.01) and need for reoperation (P = 0.01) in 27 G group. CONCLUSION: Compared with 25 G SCILS fixation, eyes managed with 27 G SCILS fixation experienced more rapid visual acuity improvement. In addition, there was a lower rate of complications including intraocular lens displacement and need for reoperation.


Asunto(s)
Afaquia Poscatarata/cirugía , Implantación de Lentes Intraoculares/métodos , Complicaciones Posoperatorias/epidemiología , Esclerótica/cirugía , Procedimientos Quirúrgicos sin Sutura/instrumentación , Agudeza Visual/fisiología , Anciano , Afaquia Poscatarata/diagnóstico , Afaquia Poscatarata/fisiopatología , Cánula , Extracción de Catarata/métodos , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Oftalmoscopía , Estudios Retrospectivos
16.
Thorac Cardiovasc Surg ; 69(1): 34-42, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-30873579

RESUMEN

INTRODUCTION: Mitochondrial DNA (mtDNA) is gaining increasing interest as a marker of cellular damage and could also act as an inflammatory mediator in cardiopulmonary bypass induced postoperative inflammatory response. Although minimally invasive heart valve surgery reportedly reduces inflammation, the mtDNA and cytokine profile in this context remains unclear. MATERIALS AND METHODS: Here, we report a prospective series of 40 elderly patients with aortic stenosis who underwent bioprosthetic aortic valve replacement (AVR) through upper ministernotomy with either a sutureless (n = 20) or a conventional (n = 20) valve. Primary end points included serial plasma levels of mtDNA (T1: at baseline; T2: 4 hours after surgery; and T3: 24s hour after surgery), cytokines (interleukin-6 [IL-6], tumor necrosis factor-α [TNF-α]), and myocardial necrosis biomarkers (MNBs), whereas secondary end points included clinical and echocardiographic data. RESULTS: Significant increases in the postoperative plasma levels (T2) of mtDNA, cytokines, and MNBs were observed in all patients. The postoperative plasma levels of mtDNA, TNF-α, and MNBs showed no significant differences between the treatment groups, although there was a trend toward lower levels in the sutureless group. The decreases in aortic cross-clamp and cardiopulmonary bypass times seen in the sutureless group were associated with significant lower postoperative levels (T2 and T3) of IL-6. CONCLUSION: AVR through upper ministernotomy was associated with a significant increase in postoperative plasma levels of mtDNA and cytokines. There was no difference in the mtDNA levels between the sutureless and conventional valve groups, suggesting a similar level of inflammation in both groups. However, the shorter operation time observed in the sutureless valve group was associated with significantly lower postoperative levels of IL-6, indicating potential clinical benefits.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Ácidos Nucleicos Libres de Células/sangre , Citocinas/sangre , ADN Mitocondrial/sangre , Implantación de Prótesis de Válvulas Cardíacas , Mediadores de Inflamación/sangre , Factores de Edad , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/diagnóstico , Biomarcadores/sangre , Bioprótesis , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Tempo Operativo , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Esternotomía , Procedimientos Quirúrgicos sin Sutura , Factores de Tiempo , Resultado del Tratamiento
17.
J Artif Organs ; 24(2): 293-295, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32959119

RESUMEN

Hypo-attenuated leaflet thickening (HALT) is gaining attention as a relatively common issue after surgical or transcatheter aortic valve replacement (AVR). However, only a few reports have described HALT in sutureless bioprosthesis, which has emerged as a promising tool with excellent hemodynamics and enhanced implantability. We herein report a 75-year-old woman who underwent quintuple coronary artery bypass grafting and sutureless AVR with a Perceval S bioprosthesis (LivaNova PLC, London, UK). Despite an uneventful perioperative course, her recovery was slow with persistent pleural effusion. Echocardiography revealed an increased transvalvular pressure gradient, and HALT was confirmed by computed tomography. The patient received aggressive anticoagulation therapy with resolution of the HALT and made an uneventful recovery. Current guidelines provide no specific recommendations for peri-procedural antithrombotic therapy for sutureless AVR. However, HALT is not rare after sutureless AVR and can lead to significant clinical consequences. In this case, aggressive anticoagulation therapy with systemic heparinization was effective as HALT treatment following early post-sutureless AVR. Further investigation is required to determine the optimal antithrombotic strategy for sutureless AVR.


Asunto(s)
Estenosis de la Válvula Aórtica/etiología , Válvula Aórtica/fisiopatología , Bioprótesis/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica/fisiología , Humanos , Movimiento (Física) , Derrame Pleural/diagnóstico , Derrame Pleural/etiología , Derrame Pleural/fisiopatología , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Procedimientos Quirúrgicos sin Sutura/instrumentación , Procedimientos Quirúrgicos sin Sutura/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
18.
Acta Neurochir (Wien) ; 163(2): 573-581, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32880068

RESUMEN

BACKGROUND: High flow bypass surgery can be a last resort procedure for patients suffering from complex neurovascular pathology. Temporary occlusion of a recipient artery in these patients could result in debilitating neurological deficits. We developed a sutureless, mechanical anastomotic connection device, the SELANA clip (Sutureless Excimer Laser-Assisted Non-occlusive Anastomosis clip: SEcl). In the present study, we aim to determine the long-term non-inferiority of the SEcl technique compared with historical data of the conventional ELANA anastomosis technique. METHODS: A total of 18 SEcl bypasses were created on the carotid artery in a porcine model in 6 different survival groups. Mean application times, flap retrieval rates, hemostasis, patency, flow, endothelialization, and remodeling were assessed. RESULTS: The mean application time of the SEcl anastomoses was 15.2 ± 9.6 min, which was faster compared with the conventional ELANA anastomoses. The flap retrieval rate of the SEcl anastomoses was 86% (32/37). Direct hemostasis was achieved in 89% (33/37) SEcl anastomoses. Patency in all surviving animals was 94% (17/18). Bypass flow after six months was 156.5 ± 24.7 mL/min. Full endothelialization of the SEcl pins was observed after 3 weeks. CONCLUSION: The SEcl technique is not inferior to the ELANA technique regarding patency, flap retrieval rate, flow, and endothelialization. On the basis of a significantly shorter application time and superior hemostasis, the SEcl technique could be preferable over the ELANA technique. A pilot study in patients is a logical next step based on our current results.


Asunto(s)
Anastomosis Quirúrgica/instrumentación , Arteria Carótida Común/cirugía , Revascularización Cerebral/instrumentación , Láseres de Excímeros , Procedimientos Quirúrgicos sin Sutura/instrumentación , Animales , Estudios de Factibilidad , Femenino , Colgajos Quirúrgicos , Instrumentos Quirúrgicos , Porcinos
19.
J Korean Med Sci ; 36(9): e57, 2021 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-33686809

RESUMEN

BACKGROUND: We compared early and 2-year clinical outcomes of sutureless aortic valve replacement (SAVR) with conventional aortic valve replacement (CAVR) in a nationwide study based on claims data. METHODS: From December 2016 to November 2018, 3,173 patients underwent bioprosthetic aortic valve replacements. SAVR and CAVR were performed in 641 and 2,532 patients, respectively. Propensity score-matched analysis was performed in 640 patient pairs. RESULTS: Operative mortality rate was 2.8% without significant differences between the SAVR (3.4%) and CAVR (2.3%) groups (P = 0.324). There were no significant differences in postoperative morbidities between the groups except for permanent pacemaker (PPM) implantation. PPM implantation rate was significantly higher in the SAVR (3.8%) than in the CAVR group (0.9%) (P < 0.001). One- and two-year overall survival was 89.1% and 87.5%, respectively, without significant differences between the groups (SAVR group vs. CAVR grouP = 89.9% and 90.5% vs. 87.2% and 88.7%, respectively; P = 0.475). There were no significant differences in the cumulative incidence of cardiac death, stroke, aortic valve reoperation and infective endocarditis between the groups. Cumulative PPM implantation incidence at 6 months in the CAVR was 1.1%, and no patient required PPM implantation after 6 months. In the SAVR, the cumulative PPM implantation incidence at 0.5, one, and two years was 3.9%, 5.0% and 5.6%, respectively. The cumulative PPM implantation rate was higher in the SAVR group than in the CAVR group (P < 0.001). CONCLUSION: Early and 2-year clinical outcomes between SAVR and CAVR were not different except for a high rate of permanent pacemaker implantation in the SAVR group.


Asunto(s)
Enfermedad de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/estadística & datos numéricos , Procedimientos Quirúrgicos sin Sutura/métodos , Anciano , Anciano de 80 o más Años , Enfermedad de la Válvula Aórtica/mortalidad , Bioprótesis/estadística & datos numéricos , Bases de Datos Factuales , Femenino , Estudios de Seguimiento , Humanos , Masculino , Marcapaso Artificial/estadística & datos numéricos , Complicaciones Posoperatorias , Puntaje de Propensión , República de Corea , Tasa de Supervivencia , Resultado del Tratamiento
20.
Pediatr Cardiol ; 42(5): 1002-1009, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33759021

RESUMEN

The efficacy of primary sutureless repair for supracardiac total anomalous pulmonary venous connection (TAPVC) needs to be confirmed. This study aimed to compare the long-term outcomes between the conventional surgery and the sutureless technique with a modified approach in superior TAPVC. Between January 2008 and December 2018, 173 patients with supracardiac TAPVC underwent surgery either with the conventional procedure (n = 130) or the sutureless repair (n = 43). Multivariate analysis and competing-risk analysis were used to identify risk factors for early death and postoperative pulmonary venous obstruction (PVO), respectively. Among 173 patients who underwent repair of supracardiac TAPVC, 46 (28%) had preoperative PVO, and 22 (12.7%) had postoperative PVO. The sutureless group had a lower postoperative PVO rate compared with the conventional group (p = 0.027). The risk factors for death were age ≤ 28 days [odds ratio (OR), 11.56; 95% confidence interval (CI) 1.33-100.47, p = 0.015], weight ≤ 3 kg (OR 9.57; 95% CI 1.58-58.09, p = 0.009), emergency operation (OR 19.24; 95% CI 3.18-116.35, p = 0.002), cardiopulmonary bypass time (OR 2.16; 95% CI 1.36-3.43, p = 0.003), cross-clamp time (OR 1.73; 95% CI 1.20-2.50, p = 0.022), and duration of ventilation (OR 1.11; 95% CI 1.02-1.21, p = 0.027). Age ≤ 28 days [Hazard Ratio (HR) 1.92; 95% CI 1.92-11.02, p < 0.001] and preoperative PVO (HR 41.70; 95% CI 8.15-213.5, p < 0.001) were associated with postoperative PVO. The sutureless repair is a reliable technique for supracardiac TAPVC. Age ≤ 28 days is associated with 30-day mortality and postoperative PVO.


Asunto(s)
Complicaciones Posoperatorias/cirugía , Enfermedad Veno-Oclusiva Pulmonar/cirugía , Síndrome de Cimitarra/cirugía , Procedimientos Quirúrgicos sin Sutura/métodos , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Modelos de Riesgos Proporcionales , Enfermedad Veno-Oclusiva Pulmonar/etiología , Enfermedad Veno-Oclusiva Pulmonar/mortalidad , Reoperación/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Procedimientos Quirúrgicos sin Sutura/mortalidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA