Biodegradable injectable polyurethanes: synthesis and evaluation for orthopaedic applications.
Adhikari, Raju; Gunatillake, Pathiraja A; Griffiths, Ian; Tatai, Lisa; Wickramaratna, Malsha; Houshyar, Shadi; Moore, Tim; Mayadunne, Roshan T M; Field, John; McGee, Margaret; Carbone, Tania.
Affiliation
  • Adhikari R; PolyNovo Biomaterials Limited, Bayview Avenue, Clayton South 3169, Victoria, Australia. raju.a@polynovo.com
Biomaterials ; 29(28): 3762-70, 2008 Oct.
Article in En | MEDLINE | ID: mdl-18632149
ABSTRACT
Biodegradable polyurethanes offer advantages in the design of injectable or preformed scaffolds for tissue engineering and other medical implant applications. We have developed two-part injectable prepolymer systems (prepolymer A and B) consisting of lactic acid and glycolic acid based polyester star polyols, pentaerythritol (PE) and ethyl lysine diisocyanate (ELDI). This study reports on the formulation and properties of a series of cross linked polyurethanes specifically developed for orthopaedic applications. Prepolymer A was based on PE and ELDI. Polyester polyols (prepolymer B) were based on PE and dl-lactic acid (PEDLLA) or PE and glycolic acid (PEGA) with molecular weights 456 and 453, respectively. Several cross linked porous and non-porous polyurethanes were prepared by mixing and curing prepolymers A and B and their mechanical and thermal properties, in vitro (PBS/37 degrees C/pH 7.4) and in vivo (sheep bi-lateral) degradation evaluated. The effect of incorporating beta-tricalcium phosphate (beta-TCP, 5 microns, 10 wt.%) was also investigated. The cured polymers exhibited high compressive strength (100-190 MPa) and modulus (1600-2300 MPa). beta-TCP improved mechanical properties in PEDLLA based polyurethanes and retarded the onset of in vitro and in vivo degradation. Sheep study results demonstrated that the polymers in both injectable and precured forms did not cause any surgical difficulties or any adverse tissue response. Evidence of new bone growth and the gradual degradation of the polymers were observed with increased implant time up to 6 months.
Subject(s)

Full text: 1 Database: MEDLINE Main subject: Polyurethanes / Biocompatible Materials / Tissue Engineering Type of study: Evaluation_studies Limits: Animals Language: En Year: 2008 Type: Article

Full text: 1 Database: MEDLINE Main subject: Polyurethanes / Biocompatible Materials / Tissue Engineering Type of study: Evaluation_studies Limits: Animals Language: En Year: 2008 Type: Article