ABSTRACT

OBJECTIVE:

The purposes of this study were to construct a model for estimation of splenic volume from standardized one-dimensional diameters of the spleen and to compare that model with the ellipsoid model for estimation of splenic volume. MATERIALS AND

METHODS:

In this retrospective study, segmentation software was used for semiautomated quantification of splenic volume by counting CT voxels in 193 consecutively registered patients. For standardization of one-dimensional measurements, the software was used to measure transaxial diameter in the slice with the largest splenic cross-sectional area. By incorporation of splenic volume and the product of width, thickness, and length into the linear regression equation, a model for estimation of splenic volume was constructed, and its performance was externally assessed. Splenic volume also was calculated with the formula for a prolate ellipsoid. The ellipsoid volume and best-fit volumes were compared with segmented splenic volume by use of Bland-Altman plot and Lin concordance correlation. A value of p < 0.05 denoted statistical significance.

RESULTS:

Splenic width was the best one-dimensional predictor of splenic volume (r = 0.84, p < 0.05). The linear regression fitted model for estimation of splenic volume (V(R)) in the initial 100 patients was V(R) = (0.36 × W × T × L) + 28, where W is width, T is thickness, and L is length (R(2) = 0.91, p < 0.05) and was externally validated by estimation of splenic volume in the other 93 patients. Compared with that observed with use of the ellipsoid formula, mean bias decreased from 22.57% to 0.93%, and the Lin coefficient increased from 0.81 to 0.96 with application of the best-fit model for calculation of splenic volume.

CONCLUSION:

The best-fit model V(R) = (0.36 × W × T × L) + 28 is more optimized than the ellipsoid formula and is associated with less bias for estimation of splenic volume.
Subject(s)

Full text: 1 Database: MEDLINE Main subject: Spleen / Tomography, X-Ray Computed / Models, Biological Type of study: Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Year: 2011 Type: Article

Full text: 1 Database: MEDLINE Main subject: Spleen / Tomography, X-Ray Computed / Models, Biological Type of study: Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Year: 2011 Type: Article