Your browser doesn't support javascript.
loading
XAS and XMCD studies of magnetic properties modifications of Pt/Co/Au and Pt/Co/Pt trilayers induced by Ga⁺ ions irradiation.
Mazalski, Piotr; Sveklo, Iosif; Kurant, Zbigniew; Ollefs, Katharina; Rogalev, Andrei; Wilhelm, Fabrice; Fassbender, Juergen; Baczewski, Lech Tomasz; Wawro, Andrzej; Maziewski, Andrzej.
Affiliation
  • Mazalski P; Faculty of Physics, University of Bialystok, Ciolkowskiego 1L, Bialystok 15-245, Poland.
  • Sveklo I; Faculty of Physics, University of Bialystok, Ciolkowskiego 1L, Bialystok 15-245, Poland.
  • Kurant Z; Faculty of Physics, University of Bialystok, Ciolkowskiego 1L, Bialystok 15-245, Poland.
  • Ollefs K; European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble, France.
  • Rogalev A; European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble, France.
  • Wilhelm F; European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble, France.
  • Fassbender J; Institute of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden-Rossendorf, PO Box 510119, Dresden 01314, Germany.
  • Baczewski LT; Institute of Physics, Polish Academy of Sciences, Al. Lotników 32/46, Warszawa 02-668, Poland.
  • Wawro A; Institute of Physics, Polish Academy of Sciences, Al. Lotników 32/46, Warszawa 02-668, Poland.
  • Maziewski A; Faculty of Physics, University of Bialystok, Ciolkowskiego 1L, Bialystok 15-245, Poland.
J Synchrotron Radiat ; 22(3): 753-9, 2015 May.
Article in En | MEDLINE | ID: mdl-25931093
ABSTRACT
Magnetic and magneto-optical properties of Pt/Co/Au and Pt/Co/Pt trilayers subjected to 30 keV Ga(+) ion irradiation are compared. In two-dimensional maps of these properties as a function of cobalt thickness and ion fluence, two branches with perpendicular magnetic anisotropy (PMA) for Pt/Co/Pt trilayers are well distinguished. The replacement of the Pt capping layer with Au results in the two branches still being visible but the in-plane anisotropy for the low-fluence branch is suppressed whereas the high-fluence branch displays PMA. The X-ray absorption spectra and X-ray magnetic circular dichroism (XMCD) spectra are discussed and compared with non-irradiated reference samples. The changes of their shapes and peak amplitude, particularly for the high-fluence branch, are related to the modifications of the local environment of Co(Pt) atoms and the etching effects induced by ion irradiation. Additionally, in irradiated trilayers the XMCD measurements at the Pt L2,3-edge reveal an increase of the magnetic moment induced in Pt atoms.
Key words

Full text: 1 Database: MEDLINE Language: En Year: 2015 Type: Article

Full text: 1 Database: MEDLINE Language: En Year: 2015 Type: Article