Your browser doesn't support javascript.
loading
Development of a quick serum IL-6 measuring system in rheumatoid arthritis.
Koyama, Kensuke; Ohba, Tetsuro; Ishii, Kentaro; Jung, Giman; Haro, Hirotaka; Matsuda, Kenichi.
Affiliation
  • Koyama K; Department of Orthopaedic Surgery, Faculty of Medicine, University of Yamanashi, Chuo, Yamanashi 409-3898, Japan. Electronic address: kkoyama@yamanashi.ac.jp.
  • Ohba T; Department of Orthopaedic Surgery, Faculty of Medicine, University of Yamanashi, Chuo, Yamanashi 409-3898, Japan.
  • Ishii K; New Frontiers Research Labs, Toray Industries, Inc., Kamakura, Kanagawa, Japan.
  • Jung G; New Frontiers Research Labs, Toray Industries, Inc., Kamakura, Kanagawa, Japan.
  • Haro H; Department of Orthopaedic Surgery, Faculty of Medicine, University of Yamanashi, Chuo, Yamanashi 409-3898, Japan.
  • Matsuda K; Department of Emergency and Critical Care Medicine, Faculty of Medicine, University of Yamanashi, Chuo, Yamanashi 409-3898, Japan.
Cytokine ; 95: 22-26, 2017 07.
Article in En | MEDLINE | ID: mdl-28214674
ABSTRACT

OBJECTIVE:

Interleukin-6 (IL-6) plays a crucial role in the pathogenesis of rheumatoid arthritis (RA). Both fulfillment of remission criteria and assessment of other methods of evaluation of RA are important for preventing joint damage progression. Measurement of serum IL-6 concentrations has been reported to be useful for monitoring RA disease activity. However, it takes at least 4-5h to measure serum IL-6 concentrations using traditional methods, which limits its utility during routine assessment in daily clinical practice settings. We established a novel method that enables measurement of serum IL-6 within 24min and requires a very small blood volume. We investigated the accuracy and efficacy of this system in RA patients.

METHODS:

One hundred fifty blood samples collected from 76 patients were measured using the two systems. We first developed the prototype of the Human IL-6 RAYFAST. Then, we examined the correlation between the prototype RAYFAST and chemiluminescent enzyme immunoassay (CLEIA) methods. Finally, we compared IL-6 concentrations and clinical parameters using both systems.

RESULTS:

The correlation between RAYFAST (x) and CLEIA (y) for IL-6 was y=0.895x-5.94, r=0.941 (p<0.0001). Serum IL-6 concentrations in RAYFAST correlated with DAS28-CRP (r=0.372, p<0.05) and DAS28-ESR (r=0.397, p<0.01). Serum IL-6 concentrations in CLEIA correlated with DAS28-CRP (r=0.313, p<0.001) and DAS28-ESR (r=0.353, p<0.001).

CONCLUSION:

This new cytokine quick measure system is as accurate as CLEIA methods. Serum IL-6 concentrations can be measured in 24min using the prototype RAYFAST. It might be usable in the daily clinical practice setting, thereby contributing to improved RA management.