ABSTRACT

Objective:

To prepare the quality control material for detection of platelet membrane glycoproteins by flowcytometry and evaluate the appearance traits, homogeneity and stability of it.

Methods:

Fresh platelets from the blood group O donors were fixed by the certain concentration of aldehyde solution and then washed by the imidazole buffer. After that, adding certain concentration of lyophilized protection solution into the preparations. The preparations were dispensed to be lyophilized and then were kept refrigerated in 2-8 ℃.According to the protocol of control of lyophilized biological products, the quality indicator for monitoring the prepared process, containing the appearance traits, the residual water, the platelet recovery and the rehydration quality were evaluated. The homogeneity and stability of these preparations were evaluated according to the CNAS-GL03 Guidance on evaluating the homogeneity and stability of samples used for proficiency testing and the ISO Guide 35 Reference material-general and statistical principles for certification.

Results:

The appearance traits and the rehydration quality of the quality control materials meeted the requirements, with the residual water distributed between 3.96% to 4.04% and the platelet recovery rate ranged from 68% to 72%.The homogeneity evaluation showed that there was no significant difference among the groups(P>0.05). The stability test indicated that the positive rate of platelet membrane glycoproteins CD42b, CD41 and CD62P of the quality control material was -0.14%, -0.14% and 0.74%, respectively, at 16 weeks after storage. There was no linear trend between the percentage of positive platelets with membrane glycoproteins and time(P>0.05).

Conclusions:

The quality control material for detection of platelet membrane glycoproteins by flow cytometry prepared by us meets the needs of the appearance traits, the residual water, the rehydration quality, the homogeneity and the longtime stability.It is hopeful to be used as internal quality control of the assay in clinic laboratory, the external quality assessment and proficiency evaluation.