Your browser doesn't support javascript.
loading
Patient Selection Process for the Harmony Transcatheter Pulmonary Valve Early Feasibility Study.
Gillespie, Matthew J; Benson, Lee N; Bergersen, Lisa; Bacha, Emile A; Cheatham, Sharon L; Crean, Andrew M; Eicken, Andreas; Ewert, Peter; Geva, Tal; Hellenbrand, William E; Hor, Kan N; Horlick, Eric M; Jones, Thomas K; Mayer, John; McHenry, Brian T; Osten, Mark D; Powell, Andrew J; Zahn, Evan M; Cheatham, John P.
Affiliation
  • Gillespie MJ; Division of Cardiology, The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania. Electronic address: Gillespie@email.chop.edu.
  • Benson LN; The Division of Cardiology, The Labatt Family Heart Center, The Hospital for Sick Children, Toronto, Canada.
  • Bergersen L; Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts.
  • Bacha EA; Department of Surgery, Columbia University, New York, New York.
  • Cheatham SL; Department of Cardiology, Nationwide Children's Hospital, Columbus, Ohio.
  • Crean AM; Peter Munk Cardiac Centre, University Health Network, Toronto General Hospital, Toronto, Canada; Joint Department of Medical Imaging, Toronto General Hospital, Toronto, Canada.
  • Eicken A; Department of Pediatric Cardiology and Congenital Heart Defects, German Heart Center Munich, Technical University Munich, Munich, Germany.
  • Ewert P; Department of Pediatric Cardiology and Congenital Heart Defects, German Heart Center Munich, Technical University Munich, Munich, Germany.
  • Geva T; Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts.
  • Hellenbrand WE; Division of Pediatric Cardiology, Yale University School of Medicine, New Haven, Connecticut.
  • Hor KN; Department of Cardiology, Nationwide Children's Hospital, Columbus, Ohio.
  • Horlick EM; Peter Munk Cardiac Centre, University Health Network, Toronto General Hospital, Toronto, Canada.
  • Jones TK; Department of Cardiology, Seattle Children's Hospital, Seattle, Washington.
  • Mayer J; Department of Cardiac Surgery, Boston Children's Hospital, Boston, Massachusetts.
  • McHenry BT; Medtronic, Mounds View, Minnesota.
  • Osten MD; Peter Munk Cardiac Centre, University Health Network, Toronto General Hospital, Toronto, Canada.
  • Powell AJ; Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts.
  • Zahn EM; The Guerin Family Congenital Heart Program, Cedars-Sinai Heart Institute, Los Angeles, California.
  • Cheatham JP; Department of Cardiology, Nationwide Children's Hospital, Columbus, Ohio.
Am J Cardiol ; 120(8): 1387-1392, 2017 Oct 15.
Article in En | MEDLINE | ID: mdl-28823485
ABSTRACT
This early feasibility study was designed to obtain in vivo data to confirm assumptions on device loading conditions of the Medtronic Harmony transcatheter pulmonary valve (TPV). Secondary objectives included procedural feasibility, safety, and valve performance. The Harmony TPV was developed for nonsurgical pulmonary valve replacement in non-right ventricle-pulmonary artery conduit patients. The Native Outflow Tract TPV Research Clinical Study was the first study approved under the Food and Drug Administration Early Feasibility Study guidance. Enrollment required that patient anatomy be precisely matched to the single-size Harmony TPV implant, necessitating a rigorous selection process. The study was nonrandomized, prospective, and performed at 3 sites. All patients met standard indications for surgical pulmonary valve replacement. The goal of the screening committee was to match the candidate anatomy to predetermined engineering criteria thought to be predictive of secure Harmony TPV implantation for the single-size device under study. A majority of the screening committee was required to recommend a patient as eligible for implant. A total of 270 patients underwent prescreening cardiac magnetic resonance imaging, 66 were enrolled and received a computed tomography scan (24%), 21 met criteria for implant and were catheterized (8%), and 20 underwent implant. Nineteen of 20 met criteria for implant success. In conclusion, the Medtronic Harmony TPV represents an emerging therapeutic option for patients with complex postoperative right ventricular outflow tract failure. The initial clinical evaluation of this technology was unique, and the highly variable anatomy of this population required careful screening to ensure acceptable device fit.
Subject(s)

Full text: 1 Database: MEDLINE Main subject: Pulmonary Valve / Pulmonary Valve Insufficiency / Cardiac Catheterization / Patient Selection / Heart Valve Prosthesis Implantation / Heart Ventricles Type of study: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Female / Humans / Male Language: En Year: 2017 Type: Article

Full text: 1 Database: MEDLINE Main subject: Pulmonary Valve / Pulmonary Valve Insufficiency / Cardiac Catheterization / Patient Selection / Heart Valve Prosthesis Implantation / Heart Ventricles Type of study: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Female / Humans / Male Language: En Year: 2017 Type: Article