Your browser doesn't support javascript.
loading
An undetectable serum prealbumin measurement led to a diagnosis of monoclonal gammopathy: two cases of spurious results in the setting of paraproteinaemia.
Choy, Kay Weng; Wijeratne, Nilika; Doery, James; Lam, Matthew.
Affiliation
  • Choy KW; Monash Pathology, Monash Health, Clayton, Vic, Australia. Electronic address: kayweng.choy@gmail.com.
  • Wijeratne N; Monash Pathology, Monash Health, Clayton, Vic, Australia; Dorevitch Pathology, Heidelberg, Vic, Australia; Department of Medicine, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, Vic, Australia.
  • Doery J; Monash Pathology, Monash Health, Clayton, Vic, Australia.
  • Lam M; Monash Pathology, Monash Health, Clayton, Vic, Australia.
Pathology ; 50(7): 767-769, 2018 12.
Article in En | MEDLINE | ID: mdl-30249449

Full text: 1 Database: MEDLINE Main subject: Paraproteinemias / Prealbumin Type of study: Diagnostic_studies Limits: Aged / Aged80 / Female / Humans / Male Language: En Year: 2018 Type: Article

Full text: 1 Database: MEDLINE Main subject: Paraproteinemias / Prealbumin Type of study: Diagnostic_studies Limits: Aged / Aged80 / Female / Humans / Male Language: En Year: 2018 Type: Article