Your browser doesn't support javascript.
loading
Reliability of low-flow vasoreactivity in the brachial artery of adolescents.
Kranen, Sascha H; Bond, Bert; Williams, Craig A; Barker, Alan R.
Affiliation
  • Kranen SH; Children's Health and Exercise Research Centre, Sport and Health Sciences, College of Life and Environmental Sciences, University of Exeter, Exeter, United Kingdom.
  • Bond B; Children's Health and Exercise Research Centre, Sport and Health Sciences, College of Life and Environmental Sciences, University of Exeter, Exeter, United Kingdom.
  • Williams CA; Children's Health and Exercise Research Centre, Sport and Health Sciences, College of Life and Environmental Sciences, University of Exeter, Exeter, United Kingdom.
  • Barker AR; Children's Health and Exercise Research Centre, Sport and Health Sciences, College of Life and Environmental Sciences, University of Exeter, Exeter, United Kingdom.
J Clin Ultrasound ; 47(3): 133-138, 2019 Mar.
Article in En | MEDLINE | ID: mdl-30474121
ABSTRACT

PURPOSE:

Macrovascular endothelial function is commonly assessed using flow-mediated dilation (FMD) and is nitric oxide (NO) dependent. However, the vasoreactivity to low flow during the FMD protocol may complement FMD interpretation. This study aimed to investigate in adolescents (1) the day-to-day reliability of low-flow-mediated constriction (L-FMC) and composite vessel reactivity (CVR); and (2) the relationship between L-FMC and FMD.

METHODS:

A retrospective analysis of data on 27 adolescents (14.3 ± 0.6 year, 12 males) was performed. Participants had two repeat measures, on separate days, of macrovascular function using high-resolution ultrasound for assessment of L-FMC, FMD, and CVR.

RESULTS:

On average, the L-FMC response was vasoconstriction on both days (-0.59 ± 2.22% and -0.16 ± 1.50%, respectively). In contrast, an inconsistent response to low flow (vasoconstriction, dilation, or no change) was observed on an individual level. Cohen's Kappa revealed poor agreement for classifying the L-FMC measurement between visits (k = 0.04, P > .05). Assessment of the actual vessel diameter was robust with a coefficient of variation of 1.7% (baseline and peak) and 2.7% (low-flow). The between-day correlation coefficient between measures was r = .18, r = .96 and r = .52 for L-FMC, FMD, and CVR, respectively. No significant correlation between FMD and L-FMC was observed for either visit (r = -.06 and r = -.07, respectively; P > .05).

CONCLUSION:

In adolescents, the low-flow vasoreactivity is inconsistent between days. Whereas the actual vessel diameter is reproducible, the measurement of L-FMC and CVR has poor between-day reliability compared to FMD. Finally, L-FMC, and FMD are not significantly correlated.