Your browser doesn't support javascript.
loading
Fluorescent N/Al Co-Doped Carbon Dots from Cellulose Biomass for Sensitive Detection of Manganese (VII).
Jayaweera, Supuli; Yin, Ke; Hu, Xiao; Ng, Wun Jern.
Affiliation
  • Jayaweera S; Nanyang Environment & Water Research Institute, Interdisciplinary Graduate School, Nanyang Technological University, Singapore, Singapore.
  • Yin K; Residues & Resource Reclamation Centre, Nanyang Environment & Water Research Institute, Nanyang Technological University, Singapore, Singapore.
  • Hu X; Department of Environmental Engineering, School of Biology and the Environment, Nanjing Forestry University, Nanjing, China.
  • Ng WJ; School of Materials Science and Engineering, Nanyang Technological University, Singapore, Singapore.
J Fluoresc ; 29(6): 1291-1300, 2019 Nov.
Article in En | MEDLINE | ID: mdl-31707509
ABSTRACT
Development of metallic and nonmetallic heteroatom doped carbon dots have gained attention due to their enhanced physicochemical and photoluminescence properties. In this study, a facile one pot hydrothermal carbonisation approach was taken to synthesise nitrogen, aluminum co-doped carbon dots (N/Al-CDs) with a photoluminescence quantum yield of 28.7%. Durian shell, a cellulose biomass waste, was used as the primary carbon source and compared to previously reported cellulose based carbon dots, this study presents one of the highest quantum yields. The structural and fluorescent properties of the synthesised N/Al-CDs were characterized through X-ray photoelectron spectroscopy (XPS), fluorescence spectra, and Fourier transform infrared spectroscopy (FTIR). The maximum emission was at 415 nm upon excitation at 345 nm. The synthesised N/Al-CDs were resistant to photobleaching and highly photostable within the pH, ionic strength and temperature variations investigated. The transmission electron microscopy (TEM) images showed particles were quasi-spherical and well dispersed with an average diameter of 10.0 nm. Further, the N/Al-CDs was developed as a fluorescence sensor for highly selective and sensitive detection of Mn (VII) ions. A linear relationship was developed over a concentration range of 0-100 µM while the limit of detection was 46.8 nM. Application of the sensor for detection of Manganese (VII) to two real water samples showed relative standard deviation was less than 3.9% and 1.3%, respectively.
Subject(s)
Key words

Full text: 1 Database: MEDLINE Main subject: Cellulose / Quantum Dots / Fluorescence / Fluorescent Dyes / Manganese Type of study: Diagnostic_studies Language: En Year: 2019 Type: Article

Full text: 1 Database: MEDLINE Main subject: Cellulose / Quantum Dots / Fluorescence / Fluorescent Dyes / Manganese Type of study: Diagnostic_studies Language: En Year: 2019 Type: Article