Your browser doesn't support javascript.
loading
A Novel Robotic Endoscopic Device Used for Operative Hysteroscopy.
Harvey, Lara; Hendrick, Richard; Dillon, Neal; Blum, Evan; Branscombe, Lauren; Webster, Scott; Webster, Robert J; Anderson, Ted.
Affiliation
  • Harvey L; Division of Minimally Invasive Gynecology, Department of Obstetrics and Gynecology, Vanderbilt University Medical Center (Drs. Harvey, R. J. Webster, and Anderson). Electronic address: lara.harvey@vumc.org.
  • Hendrick R; Virtuoso Surgical, Inc. (Drs. Hendrick, Dillon, S. Webster, R.J. Webster, Ms. Branscombe, and Mr. Blum), Nashville, Tennessee.
  • Dillon N; Virtuoso Surgical, Inc. (Drs. Hendrick, Dillon, S. Webster, R.J. Webster, Ms. Branscombe, and Mr. Blum), Nashville, Tennessee.
  • Blum E; Virtuoso Surgical, Inc. (Drs. Hendrick, Dillon, S. Webster, R.J. Webster, Ms. Branscombe, and Mr. Blum), Nashville, Tennessee.
  • Branscombe L; Virtuoso Surgical, Inc. (Drs. Hendrick, Dillon, S. Webster, R.J. Webster, Ms. Branscombe, and Mr. Blum), Nashville, Tennessee.
  • Webster S; Virtuoso Surgical, Inc. (Drs. Hendrick, Dillon, S. Webster, R.J. Webster, Ms. Branscombe, and Mr. Blum), Nashville, Tennessee.
  • Webster RJ; Division of Minimally Invasive Gynecology, Department of Obstetrics and Gynecology, Vanderbilt University Medical Center (Drs. Harvey, R. J. Webster, and Anderson); Virtuoso Surgical, Inc. (Drs. Hendrick, Dillon, S. Webster, R.J. Webster, Ms. Branscombe, and Mr. Blum), Nashville, Tennessee.
  • Anderson T; Division of Minimally Invasive Gynecology, Department of Obstetrics and Gynecology, Vanderbilt University Medical Center (Drs. Harvey, R. J. Webster, and Anderson).
J Minim Invasive Gynecol ; 27(7): 1631-1635, 2020.
Article in En | MEDLINE | ID: mdl-32540499
ABSTRACT
To trial the use of a novel endoscopic robot that functions using concentric tube robots, enabling 2-handed surgery in small spaces, in a bioengineering laboratory. This was a feasibility study of the endoscopic robot for hysteroscopic applications, including removal of a simulated endometrial polyp. The endoscopic robot was successfully used to resect a simulated endometrial polyp from a porcine uterine tissue model in a fluid environment. The potential advantages of this platform to the surgeon may include improved exposure, finer dissection capability, and use of a 2-handed surgical technique. Further study regarding the safe, efficient, and cost-effective use of the endoscopic robot in gynecology is needed.
Subject(s)
Key words

Full text: 1 Database: MEDLINE Main subject: Robotics / Hysteroscopy / Endoscopy / Inventions / Robotic Surgical Procedures Limits: Animals / Female / Humans Language: En Year: 2020 Type: Article

Full text: 1 Database: MEDLINE Main subject: Robotics / Hysteroscopy / Endoscopy / Inventions / Robotic Surgical Procedures Limits: Animals / Female / Humans Language: En Year: 2020 Type: Article