Your browser doesn't support javascript.
loading
Lower urinary tract electrical sensory assessment: a systematic review and meta-analysis.
van der Lely, Stéphanie; Schmidhalter, Melanie R; Knüpfer, Stephanie C; Sartori, Andrea M; Schneider, Marc P; Stalder, Stephanie A; Kessler, Thomas M; Liechti, Martina D; Mehnert, Ulrich.
Affiliation
  • van der Lely S; Department of Neuro-Urology, Balgrist University Hospital, University of Zürich, Zürich, Switzerland.
  • Schmidhalter MR; Department of Neuro-Urology, Balgrist University Hospital, University of Zürich, Zürich, Switzerland.
  • Knüpfer SC; Department of Neuro-Urology, Balgrist University Hospital, University of Zürich, Zürich, Switzerland.
  • Sartori AM; Department of Urology, University Hospital of Bonn, Bonn, Germany.
  • Schneider MP; Department of Neuro-Urology, Balgrist University Hospital, University of Zürich, Zürich, Switzerland.
  • Stalder SA; Department of Medicine, Harvard Medical School, Beth Israel Deaconess Medical Center, Boston, MA, USA.
  • Kessler TM; Department of Neuro-Urology, Balgrist University Hospital, University of Zürich, Zürich, Switzerland.
  • Liechti MD; Department of Neuro-Urology, Balgrist University Hospital, University of Zürich, Zürich, Switzerland.
  • Mehnert U; Department of Neuro-Urology, Balgrist University Hospital, University of Zürich, Zürich, Switzerland.
BJU Int ; 130(2): 166-180, 2022 08.
Article in En | MEDLINE | ID: mdl-34390120
ABSTRACT

OBJECTIVES:

To summarize the current literature on lower urinary tract electrical sensory assessment (LUTESA), with regard to current perception thresholds (CPTs) and sensory evoked potentials (SEPs), and to discuss the applied methods in terms of technical aspects, confounding factors, and potential for lower urinary tract (LUT) diagnostics.

METHODS:

The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Medline (PubMed), Embase and Scopus were searched on 13 October 2020. Meta-analyses were performed and methodological qualities of the included studies were defined by assessing risk of bias (RoB) as well as confounding.

RESULTS:

After screening 9925 articles, 80 studies (five randomized controlled trials [RCTs] and 75 non-RCTs) were included, comprising a total of 3732 patients and 692 healthy subjects (HS). Of these studies, 61 investigated CPTs exclusively and 19 reported on SEPs, with or without corresponding CPTs. The recording of LUTCPTs and SEPs was shown to represent a safe and reliable assessment of LUT afferent nerve function in HS and patients. LUTESA demonstrated significant differences in LUT sensitivity between HS and neurological patients, as well as after interventions such as pelvic surgery or drug treatments. Pooled analyses showed that several stimulation variables (e.g. stimulation frequency, location) as well as patient characteristics might affect the main outcome measures of LUTESA (CPTs, SEP latencies, peak-to-peak amplitudes, responder rate). RoB and confounding was high in most studies.

CONCLUSIONS:

Preliminary data show that CPT and SEP recordings are valuable tools to more objectively assess LUT afferent nerve function. LUTESA complements already established diagnostics such as urodynamics, allowing a more comprehensive patient evaluation. The high RoB and confounding rate was related to inconsistency and inaccuracy in reporting rather than the technique itself. LUTESA standardization and well-designed RCTs are crucial to implement LUTESA as a clinical assessment tool.