Your browser doesn't support javascript.
loading
Femoral Head Length Impact on Outcomes Following Total Hip Arthroplasty in 36 Millimeter Cobalt Chrome-on-Highly Crosslinked Polyethylene Articulations.
Salmons, Harold I; Karczewski, Daniel; Ledford, Cameron K; Bedard, Nicholas A; Wyles, Cody C; Abdel, Matthew P.
Affiliation
  • Salmons HI; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Karczewski D; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Ledford CK; Department of Orthopedic Surgery, Mayo Clinic, Jacksonville, Florida.
  • Bedard NA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Wyles CC; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Abdel MP; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
J Arthroplasty ; 38(9): 1787-1792, 2023 09.
Article in En | MEDLINE | ID: mdl-36805114
ABSTRACT

BACKGROUND:

Despite concerns for corrosion, dislocation, and periprosthetic femur fractures, minimal literature has investigated the effect of adjusting femoral head length on outcomes after primary total hip arthroplasty (THA). Therefore, we aimed to investigate the effect of femoral head length on the risk of any revision and reoperation following cobalt chromium (CoCr)-on-highly crosslinked polyethylene (HXLPE) THAs.

METHODS:

Between 2004 and 2018, we identified 1,187 primary THAs with CoCr-on-HXLPE articulations using our institutional total joint registry. The mean age at THA was 71 years (range, 19-97), 40% were women, and mean body mass index was 30 (range, 10-68). All THAs using 36 mm diameter femoral heads were included. Neutral (0 mm), positive, or negative femoral head lengths were used in 42, 31, and 27% of the THAs, respectively. Kaplan-Meier survivorship was assessed. The mean follow-up was 7 years (range, 2-16).

RESULTS:

The 10-year survivorships free of any revision or reoperation were 94 and 92%, respectively. A total of 47 revisions were performed, including periprosthetic femur fracture (17), periprosthetic joint infection (8), dislocation (7), aseptic loosening of either component (6), corrosion (4), and other (5). Nonrevision reoperations included wound revision (11), open reduction and internal fixation of periprosthetic femur fracture (4), and abductor repair (2). Multivariable analyses found no significant associations between femoral head length and revision or reoperation.

CONCLUSION:

Altering femoral head lengths in 36 mm CoCr-on-HXLPE THAs did not affect outcomes. Surgeons should select femoral head lengths that optimize hip stability and center of rotation. LEVEL OF EVIDENCE III.
Subject(s)