Your browser doesn't support javascript.
loading
[Diagnostic Efficacy of 68Ga-Labeled Prostate-Specific Membrane Antigen and 18F-Labeled Sodium Fluoride PET/CT in Prostate Cancer With Bone Metastasis].
Wang, An-Bo; Feng, Li-Jia; Ni, Ping-Ping; He, Li-Meng; Li, Hong-Mei; Zhang, Wei.
Affiliation
  • Wang AB; Department of Nuclear Medicine,The First People's Hospital of Neijiang,Neijiang,Sichuan 641000,China.
  • Feng LJ; Department of Nuclear Medicine,The First People's Hospital of Neijiang,Neijiang,Sichuan 641000,China.
  • Ni PP; Department of Nuclear Medicine,The First People's Hospital of Neijiang,Neijiang,Sichuan 641000,China.
  • He LM; Department of Nuclear Medicine,Sichuan Provincial People's Hospital,Sichuan Academy of Medical Sciences,Chengdu 610072,China.
  • Li HM; Department of Nuclear Medicine,Affiliated Hospital of Southwest Medical University,Luzhou,Sichuan 646000,China.
  • Zhang W; Department of Nuclear Medicine,Sichuan Provincial People's Hospital,Sichuan Academy of Medical Sciences,Chengdu 610072,China.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 45(4): 634-639, 2023 Aug.
Article in Zh | MEDLINE | ID: mdl-37654144
ABSTRACT
Objective To compare the efficiency of 68Ga-labeled prostate-specific membrane antigen (68Ga-PSMA-11) and 18F-labeled sodium fluoride (18F-NaF) PET/CT in the diagnosis of bone metastasis in the patients with prostate cancer.Methods The prostate cancer patients suspected of bone metastasis who underwent 68Ga-PSMA-11 PET/CT and 18F-NaF PET/CT from January 2018 to January 2021 were included in this study.The number of lesions,maximum standardized uptake value (SUVmax),and tumor-to-background (T/B) ratio were compared between the two methods.Results 18F-NaF PET/CT detected more metastases than 68Ga-PSMA-11 PET/CT (310 vs.264,P<0.001).The median SUVmax[23.2 (16.4,33.4) vs.4.1 (2.5,5.6)] and median T/B ratio[7.0 (4.9,9.9) vs.6.7 (3.7,9.6)] of 18F-NaF PET/CT were higher than those of 68Ga-PSMA-11 PET/CT (all P<0.001).With the number of lesions as the indicator,the sensitivity,specificity,accuracy,positive predictive value,and negative predictive value of 18F-NaF PET/CT were 100.0%,92.0%,92.0%,98.7%,and 100.0% respectively,and those of 68Ga-PSMA-11 PET/CT were 85.2%,94.0%,79.2%,98.9%,and 50.5%,respectively.Conclusion 18F-NaF PET/CT is superior to 68Ga-PSMA-11 PET/CT in the detection of bone metastases of prostate cancer.
Key words

Full text: 1 Database: MEDLINE Type of study: Diagnostic_studies Language: Zh Year: 2023 Type: Article

Full text: 1 Database: MEDLINE Type of study: Diagnostic_studies Language: Zh Year: 2023 Type: Article