Dynamic performance of a membrane-based variable focus lens with a large aperture.
Appl Opt ; 62(17): 4609-4617, 2023 Jun 10.
Article in En | MEDLINE | ID: mdl-37707158
ABSTRACT
Dynamic performance is one of the most important characteristics of a variable focus lens. However, there are few studies investigating the dynamic response of a membrane-based variable focus lens. In this paper, we present a mathematical model to describe spring-damping phenomena in theory. The first order natural frequencies with different scales were confirmed via finite element analysis. We also built a dynamic response experiment platform with changeable optical apertures, which was driven by a high-speed piezo stack actuator. A photodiode module was placed behind the lens to measure the variation of light luminance as the lens changed, and a laser displacement sensor was used to measure the deformation of the membrane. A series of data was collected with different optical apertures (20 mm, 30 mm, 50 mm) and different pre-stretching ratios (200%, 300%) under different driving frequencies (from 5 Hz to 25 Hz in every 5 Hz step). The experimental results were consistent with the mathematical model, which showed that the first order natural frequency increased as the aperture decreased or the membrane stiffness increased. This frequency-dependent characteristic of the variable focus lens provides a basis for further research on its dynamic performance.

Full text: 1 Database: MEDLINE Type of study: Prognostic_studies Language: En Year: 2023 Type: Article

Full text: 1 Database: MEDLINE Type of study: Prognostic_studies Language: En Year: 2023 Type: Article