Your browser doesn't support javascript.
loading
Ratiometric fluorescence detection of dopamine based on copper nanoclusters and carbon dots.
Meng, Zhihan; Sun, Shupei; Pu, Ximing; Wang, Juang; Liao, Xiaoming; Huang, Zhongbing; Deng, Yi; Yin, Guangfu.
Affiliation
  • Meng Z; College of Biomedical Engineering, Sichuan University, Chengdu 610065, Sichuan, People's Republic of China.
  • Sun S; College of Optoelectronics Engineering, Chengdu University of Information Technology, Chengdu 610225, Sichuan, People's Republic of China.
  • Pu X; College of Biomedical Engineering, Sichuan University, Chengdu 610065, Sichuan, People's Republic of China.
  • Wang J; College of Biomedical Engineering, Sichuan University, Chengdu 610065, Sichuan, People's Republic of China.
  • Liao X; College of Biomedical Engineering, Sichuan University, Chengdu 610065, Sichuan, People's Republic of China.
  • Huang Z; College of Biomedical Engineering, Sichuan University, Chengdu 610065, Sichuan, People's Republic of China.
  • Deng Y; College of Chemical Engineering, Sichuan University, Chengdu 610041, Sichuan, People's Republic of China.
  • Yin G; College of Biomedical Engineering, Sichuan University, Chengdu 610065, Sichuan, People's Republic of China.
Nanotechnology ; 35(23)2024 Mar 18.
Article in En | MEDLINE | ID: mdl-38417161
ABSTRACT
Nanoclusters for fluorescence detection are generally comprised of rare and expensive noble metals, and the nanoclusters based on more affordable transition metal have attracted increasing attention. This study designed a ratiometric fluorescent probe to detect dopamine (DA), an important neurotransmitter. With carbon dots encapsulated within silica (CDs@SiO2) as the reference, the emitted reference signal was almost unchanged due to the protection of inert silicon shell. Meanwhile, copper nanoclusters modified with 3-aminophenyl boronic acid (APBA-GSH-CuNCs) provided the sensing signal, in which the phenylboric acid could specifically recognize the cis-diol structure of DA, and caused the fluorescence quenching by photoinduced electron transfer. This dual emission ratiometric fluorescent probe exhibited high sensitivity and anti-interference, and was able to selectively responded to DA with a linear range of 0-1.4 mM, the detection limit of 5.6 nM, and the sensitivity of 815 mM-1. Furthermore, the probe successfully detected DA in human serum samples, yielding recoveries ranging from 92.5% to 102.7%. Overall, this study highlights the promising potential of this ratiometric probe for detecting DA.
Subject(s)
Key words

Full text: 1 Database: MEDLINE Main subject: Quantum Dots Limits: Humans Language: En Year: 2024 Type: Article

Full text: 1 Database: MEDLINE Main subject: Quantum Dots Limits: Humans Language: En Year: 2024 Type: Article