Your browser doesn't support javascript.
loading
Prediction of Lymph Node Metastasis in T1 Colorectal Cancer Using Artificial Intelligence with Hematoxylin and Eosin-Stained Whole-Slide-Images of Endoscopic and Surgical Resection Specimens.
Song, Joo Hye; Kim, Eun Ran; Hong, Yiyu; Sohn, Insuk; Ahn, Soomin; Kim, Seok-Hyung; Jang, Kee-Taek.
Affiliation
  • Song JH; Department of Internal Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul 05030, Republic of Korea.
  • Kim ER; Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea.
  • Hong Y; Department of R&D Center, Arontier Co., Ltd., Seoul 06735, Republic of Korea.
  • Sohn I; Department of R&D Center, Arontier Co., Ltd., Seoul 06735, Republic of Korea.
  • Ahn S; Department of Pathology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea.
  • Kim SH; Department of Pathology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea.
  • Jang KT; Department of Pathology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea.
Cancers (Basel) ; 16(10)2024 May 16.
Article in En | MEDLINE | ID: mdl-38791978
ABSTRACT
According to the current guidelines, additional surgery is performed for endoscopically resected specimens of early colorectal cancer (CRC) with a high risk of lymph node metastasis (LNM). However, the rate of LNM is 2.1-25.0% in cases treated endoscopically followed by surgery, indicating a high rate of unnecessary surgeries. Therefore, this study aimed to develop an artificial intelligence (AI) model using H&E-stained whole slide images (WSIs) without handcrafted features employing surgically and endoscopically resected specimens to predict LNM in T1 CRC. To validate with an independent cohort, we developed a model with four versions comprising various combinations of training and test sets using H&E-stained WSIs from endoscopically (400 patients) and surgically resected specimens (881 patients) Version 1, Train and Test surgical specimens; Version 2, Train and Test endoscopic and surgically resected specimens; Version 3, Train endoscopic and surgical specimens and Test surgical specimens; Version 4, Train endoscopic and surgical specimens and Test endoscopic specimens. The area under the curve (AUC) of the receiver operating characteristic curve was used to determine the accuracy of the AI model for predicting LNM with a 5-fold cross-validation in the training set. Our AI model with H&E-stained WSIs and without annotations showed good performance power with the validation of an independent cohort in a single center. The AUC of our model was 0.758-0.830 in the training set and 0.781-0.824 in the test set, higher than that of previous AI studies with only WSI. Moreover, the AI model with Version 4, which showed the highest sensitivity (92.9%), reduced unnecessary additional surgery by 14.2% more than using the current guidelines (68.3% vs. 82.5%). This revealed the feasibility of using an AI model with only H&E-stained WSIs to predict LNM in T1 CRC.
Key words